Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Counties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Stakeholder-guided holistic, Adaptive Framework for enhancing community Energy Resilience (SAFER) (Final Technical Report)

The Stakeholder-guided holistic, Adaptive Framework for enhancing community Energy Resilience (SAFER) project advances resilience science and engineering by addressing challenges in rural Kansas communities where aging infrastructure, extreme weather, and socioeconomic disparities heighten vulnerability to energy disruptions. Traditional approaches often focus on technical performance while overlooking community concerns and priorities. SAFER responds by integrating community perspectives with advanced analytical frameworks to create a holistic model for measuring and improving resilience. Project objectives included developing novel resilience metrics, advancing modeling frameworks that capture interdependencies across infrastructures, and embedding community-centric indicators directly into planning processes for distributed energy resources. The key technical innovations included the creation of self-organizing map (SOM)-based indices for objective resilience quantification, hetero-functional graph theory (HFGT) models linking power, water, transportation, and community assets, and graph neural network (GNN) tools for identifying critical nodes in complex systems. Community-centric energy planning was demonstrated through optimal siting and sizing of (photovoltaic) PV and battery storage, ensuring resilience enhancements also addressed energy burden and energy insecurity. SAFER engaged community partners in Dodge City and Ford County through surveys, focus groups, and workshops, generating more than 600 responses that established baseline measures of energy burden, financial insecurity, and willingness-to-pay to avoid outages. This data, organized in terms of a community capitals framework, informed the development of weighted reliability indices that better reflect community costs than traditional utility metrics. SAFER’s GNN-based critical node identification framework identified expert-labelled critical nodes with over 99% accuracy, while also uncovering additional functionalities essential for proactive resilience planning. The project’s models demonstrated that optimal PV and storage deployment could improve resilience indices by over 11 percent, with dispatch strategies further enhancing outcomes, confirming both the technical effectiveness and economic feasibility of these approaches. Through its combined emphasis on rigorous modeling, community-focused planning, and community engagement, SAFER advances the state of resilience research while delivering direct benefits to rural communities. The project provides tools, guidelines, and resilience heatmaps that help utilities, local governments, and residents better anticipate disruptions, prioritize investments, and strengthen the capacity to withstand and recover from energy-related hazards. Furthermore, the developed HFG and GNN frameworks are designed for transferability, allowing them to be adapted for resilience planning in other communities with minimal retraining. This inductive learning capability provides a scalable pathway to extend the SAFER project’s impact. Thus, creating a foundation for a nationally applicable model of infrastructure resilience. Additionally, the HFG can also be extended to include other FEMA community lifelines.

14 SOLAR ENERGY↗

Techno Economic Analysis for Production of Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues (CRADA Final Report)

West Biofuels - in collaboration with the University of California San Diego, the University of California Davis, the National Laboratory of the Rockies (NLR), the Colorado School of Mines’ Center for Hydrate Research, Placer County Air Pollution Control District, the Sierra Business Council, and the Southern California Gas Company (SoCalGas)-will demonstrate an innovative pathway to convert forest biomass to renewable gas (RG). The project, Production of Pipeline Grade Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues, will utilize an existing pilot-scale gasification system and data and lessons learned from a lab-scale catalytic reactor design, develop, and demonstrate an integrated pilot-scale RG process with a scaled-up catalytic reactor and hydrate-based gas separation process. This robust and simple process uses a commercial proven gasifier, a commercially available catalyst that can tolerate gas contaminants, and a gas separation process that simplifies the downstream processing. Current testing has shown that the process can yield a large amount of methane rich renewable gas in addition to a mixture of propanol, ethanol and other higher alcohols and the relative amounts can be controlled by shifting the process conditions. This process is novel and groundbreaking because the product mixture of RG and valuable alcohols byproducts makes RG production economically feasible at $\$$12 per million British thermal units (MMBtu) or less using forest biomass from high hazard zones.

09 BIOMASS FUELS↗

A Forward-Looking Dataset of EV Managed Charging Resource and Costs

This presentation summarizes a high-resolution, forward-looking dataset of EV adoption, EV charging, and managed charging resource. Vehicle-level data are grounded in current adoption and charging patterns, and ~200,000 real-world vehicle-weeks of travel data covering all on-road segments (i.e., light-duty, transit and school buses, local, regional and long-haul medium- and heavy-duty). The data, which include multiple charging profiles per vehicle to bound flexibility, are then processed and aggregated to describe baseline charging and charge management resource by county, hour, year, scenario, and vehicle type. Coupled with one of four scenarios of how EV managed charging costs might evolve over time, the dataset enables a power sector capacity expansion model to select cost-optimal quantities of EV managed charging and supply-side resources to reliably satisfy demand. Five integration strategies: Baseline, Daytime and Flat (passive), Flex (active), and Stress (anti-strategy), illustrate how baseline charging and flexibility potential changes with EVSE build-out and charging preferences.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Fleet Operations With Telematics [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Prince William County, VA with information about fleet charging and telematics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantifying the Effect of Economic Development Zones on Electrical Load Growth in Kentucky [Slides]

The Kentucky Energy and Environment Cabinet has recently undertaken a comprehensive effort to map and catalog potential economic development sites across the state. The purpose of this technical assistance is to quantify the potential impact of developing designated sites on Kentucky's electricity load growth, providing insights at both state and county level considering the next 10 years. This analysis should explicitly incorporate and address key project uncertainties by developing various load growth scenarios that account for development scale, site specificity, and sector variability. The need for a site-specific analysis comes from the understanding that conventional econometric (top-down) load forecasting models cannot sufficiently isolate or predict the discrete load increases resulting from the development of these unique and targeted economic sites.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Florida Regional DAC Hub

This project supported the U.S. Department of Energy's (DOE) mission to reduce the environmental and climate impacts of fossil fuels and industrial processes, contributing to the goal of achieving net-zero emissions across the U.S. economy. The primary objective is to conduct a feasibility study for a Regional Direct Air Capture (DAC) Hub in Bay County, Florida. This hub takes advantage of the region’s deep, permeable saline aquifers (Tuscaloosa Group, 1,500–2,150 meters deep), which have been the focus of numerous geological storage studies.

42 ENGINEERING↗

TASTI-GRID: a holistic view of Florida's grid resilience opportunities

In December of 2025, the American Society of Civil Engineers updated Florida’s infrastructure grade to a ”C+” – reflecting overall investments in recent years. With the recommendation to further strengthen the electric grid and establish consistent building standards, extreme weather, aging infrastructure, and population in-migration are still compounding Florida’s grid vulnerabilities. Key challenges related to hurricane and other tropical & marine weather events are not unique to Florida. However, the state’s topography, location, demographics, and variation among rural and urban centers for tourism and industry, demonstrate the need for unique approaches to advancing critical infrastructure resilience, particularly for large concentrations of elderly residents or in areas of historic underinvestment. Florida’s grid asset advancements are credited with a reduction in average power outage durations. Yet, improvements since 2021 have set the stage for future resilience activities – as modernization efforts have greatly improved data collection – enabling better understanding of vulnerabilities and trends across counties and localities (particularly in Central Florida).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility of Enhanced Geothermal Systems (EGS) Development at Bradys Hot Springs, Nevada

The Bradys EGS project focused on utilizing EGS technology to improve permeability in an existing non-productive well (15-12 ST1, located on BLM land) at Ormat’s Bradys geothermal facility in Churchill County, Nevada. The Bradys geothermal field is located within the Hot Springs Mountains, approximately 50 miles northeast of Reno, NV, along the western boundary of a very large intermontane basin known as the Carson Sink. It is one of several producing geothermal areas in the region; the Desert Peak, Stillwater, Soda Lake, and Salt Wells geothermal projects also lie within the Carson Sink, which is a region of high heat flow characterized by prominent NNE-striking faults that have formed in response to regional extension within the Basin and Range geologic province.

15 GEOTHERMAL ENERGY↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NM 502 Road Safety Audit Report

The Texas A&M Transportation Institute (TTI) and the Los Alamos National Laboratory - Parking and Transportation Services (LANL) have been working in close collaboration to seek solutions for parking, traffic operations, traffic safety, and transit issues facing LANL. NM 502 is a main route for employee traffic entering the lab as well as traffic in and out of the Los Alamos Townsite. The section of roadway in the vicinity of Camino Entrada is of particular interest as it was the site of two very serious crashes involving the extended LANL family, and it is also the entry point onto NM 502 for Los Alamos County Operations to include the school district and transit vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Preliminary Seismic Yield Estimates of the July 1, 2025 Explosions near Esparto California

A series of large damaging explosions involving fireworks storage occurred near Esparto, Yolo County California on July 1, 2025. Three explosions were located and reported by the University of California Berkeley Seismology Laboratory (UCB/BSL) and the United States Geological Survey (USGS). Analysis of local distance (< 30 km) seismic recordings of the first blast indicates that there were actually three explosions with later blasts delayed by about 3 and 30 seconds. We measured the first arriving P-wave amplitudes on four of these events with good signal-to-noise ratios.

58 GEOSCIENCES↗

Building 100 Groundwater Bioremediation at the Former DOE Pinellas Plant, Florida: Review of Progress and Opportunities

Weapons research, development, and production operations at the former Pinellas Plant, which includes the Building 100 area, released chlorinated organic solvents into the subsurface, contaminating the underlying soil and groundwater. The site was sold to Pinellas County and is now home to a thriving industrial park known as the Young - Rainey Science, Technology, and Research (STAR) Center. The US Department of Energy (DOE) has applied bioremediation at the Building 100 Area as a key technology to clean up the chlorinated volatile organic compound (cVOC) contamination in soil and groundwater. The monitoring data indicate significant progress toward remedial objectives over the past two decades. Starting conditions in the 1980s-1990s included areas containing residual undissolved dense nonaqueous phase liquids (DNAPLs) and the associated presence of an extensive high concentration plume in the groundwater. The original parent cVOCs were primarily tetrachloroethene (PCE) and trichloroethene (TCE). After several informative pilot studies, bioremediation was implemented at the Building 100 Area of the site and relies on reductive biological pathways and the sequential removal of chlorine from the parent cVOCs forming dichloroethane (DCE) and chloroethene (vinyl chloride, VC). As bioremediation sites evolve toward cleanup, the trends in VC concentrations often serve as a critical indicator for progress and remediation timeframe because VC typically has a lower concentration target remedial objective (nominally 1 to 2 μg/L) compared to PCE and TCE (nominally 3 to 5 μg/L).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding Fleet Charging Needs [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, National Laboratory of the Rockies, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Prince William County, VA with information about fleet charging and telematics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

EV Stock and Load Forecasting for HECO [Slides]

This presentation covers the work completed for the HECO Forecasting Department for the Electric Vehicle Stock and Load Forecast for Integrated Grid Planning project. This project uses a suite of detailed analytical tools developed by the National Laboratory of the Rockies, including TEMPO and EVI-Pro, to develop future scenarios to 2050 of county-level electric vehicle adoption and associated annual hourly charging load profiles for the state of Hawaii.

33 ADVANCED PROPULSION SYSTEMS↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗