Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Off-policy deep reinforcement learning with automatic entropy adjustment for adaptive online grid emergency control

Electric overloading conditions and contingencies put modern power systems at risk of voltage collapse and blackouts. Load shedding is crucial to maintain voltage stability for grid emergency control. However, the rule- or model-based schemes rely on accurate dynamic system models and face considerable challenges in adapting to various operating conditions and uncertain event occurrences. Here, to address these issues, this paper proposes a novel deep reinforcement learning (DRL)-based voltage stability control algorithm with automatic entropy adjustment (AEA) for grid emergency control. Various dynamic network components for complex system operations are modeled to construct the DRL environment. An off-policy soft actor-critic architecture is developed to maximize the expected reward and policy entropy simultaneously. The AEA mechanism is proposed to facilitate the policy maximum entropy procedure, and the proposed method can automatically provide effective discrete and continuous actions against various fault scenarios. Our approach accomplishes high sampling efficiency, scalability, and auto-adaptivity of the control policies under high uncertainties. Comparative studies with the existing DRL-based control methods in IEEE benchmarks indicate salient performance improvement of the proposed method for dynamic system emergency control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decarbonizing via disparities: Problematizing the relationship between social identity and solar energy transitions in the United States

As solar adoption across the United States continues to grow, so do the gaps between rural and urban communities in how they choose to embrace these technologies, leading to serious questions of social justice and equity by researchers and policymakers alike. While recent studies have examined the racial and social justice elements of solar adoption alongside institutions' role in shaping pro-solar policies, codes, and code enforcement, an opportunity exists to discuss how the place and composition of the body politic in terms of race/ethnicity and rurality exists. This paper establishes a methodology for examining location and body politic composition concerning adopting all types of solar (residential, non-residential, utility-scale), utilizing the State of Georgia as a case study. Results indicate that the approach yields useful and informative findings; namely, there is a significant difference in adopting non-residential and utility-scale solar between rural and urban counties. We conclude by discussing further opportunities to expand on this analysis and the impact of assessing solar adoption in terms of value alignment between a body politic and the policies that shape the adoption of sustainable energy technologies. Finally, combining solar adoption information for the State of Georgia with Census data, this study compares solar adoption trends across counties--grouped by urban/rural classification and racial and ethnic majority.

14 SOLAR ENERGY↗

Forced convective flow and heat transfer of upward cocurrent air-water slug flow in vertical plain and swirl tubes

This experimental study comparatively examined the two-phase flow structures, pressured drops and heat transfer performances for the cocurrent air-water slug flows in the vertical tubes with and without the spiky twisted tape insert. The two-phase flow structures in the plain and swirl tubes were imaged using the computerized high frame-rate videography with the Taylor bubble velocity measured. Superficial liquid Reynolds number (Re{sub L}) and air-to-water mass flow ratio (AW), which were respectively in the ranges of 4000-10000 and 0.003-0.02 were selected as the controlling parameters to specify the flow condition and derive the heat transfer correlations. Tube-wise averaged void fraction and Taylor bubble velocity were well correlated by the modified drift flux models for both plain and swirl tubes at the slug flow condition. A set of selected data obtained from the plain and swirl tubes was comparatively examined to highlight the impacts of the spiky twisted tape on the air-water interfacial structure and the pressure drop and heat transfer performances. Empirical heat transfer correlations that permitted the evaluation of individual and interdependent Re{sub L} and AW impacts on heat transfer in the developed flow regions of the plain and swirl tubes at the slug flow condition were derived. (author)

02 PETROLEUM↗

Adaptive Interface-PINNs (AdaI-PINNs) for transient diffusion: Applications to forward and inverse problems in heterogeneous media

We model transient diffusion in heterogeneous materials using a novel physics-informed neural networks framework (PINNs) termed Adaptive interface physics-informed neural networks or AdaI-PINNs (Roy et al. arXiv preprint arXiv:2406.04626, 2024). AdaI-PINNs utilize different activation functions with trainable slopes tailored to each material region within the computational domain, allowing for a fully automated and adaptive PINNs approach to model interface problems with strongly and weakly discontinuous solutions. To enhance its performance in highly heterogeneous transient diffusion systems, we prescribe a suite of robust practices, including appropriate non-dimensionalization of equations, a biased sampling method, Glorot initialization, and the hard enforcement of boundary and initial conditions. Here we evaluate the efficacy of the proposed method on several benchmark forward and inverse problems. Comparative studies on one-dimensional and two-dimensional benchmark problems reveal that the modified AdaI-PINNs outperform its unmodified counterpart, achieving root-mean-square errors that are at least two orders of magnitude better in forward problems. For inverse problems, the maximum errors in the approximated diffusion coefficients by modified AdaI-PINNs are four orders of magnitude better than those of the unmodified version. Additionally, modified AdaI-PINNs demonstrate improved stability in problems with large material mismatches.

42 ENGINEERING↗

Applying NIR and MIR spectroscopy for C and soil property prediction in northern cold-region ecosystems. Which approach works better?

Here, developing reliable predictions of soil attributes is necessary to understand northern cold-region climate-soil feedback. Calibration models using near-infrared (NIR) and mid-infrared (MIR) spectroscopy were developed to predict eight commonly measured soil properties for 119 soil samples representing a range of vegetation types, parent materials, and soil types spanning >23° of latitude from southeast Alaska to the Canadian high Arctic. In order to obtain a more accurate prediction, this study compared the performance of linear and non-linear calibration techniques, including lasso regression (Lasso), support vector machine (SVM), random forest (RF) and classic partial least squares (PLS) to predict different soil properties of these soils. Comparing the four models, we noticed that their performance was quite similar for MIR overall, while NIR achieved better results with a PLS model for our dataset. PLS coupled with MIR showed a better performance for soil parameters, such as total organic carbon (TOC), total nitrogen (TN), cation exchange capacity (CEC) and clay (R-squared of 0.9, 0.81, 0.80, and 0.84) when compared with NIR (R-squared of 0.85, 0.72, 0.81 and 0.68). However, using either MIR or NIR spectroscopy, PLS predictions for bulk density (BD) and sand content were not accurate. The variable importance analysis based on the PLS model successfully estimated the relative contribution of wavelengths influencing soil property predictions most. Overall, TOC, TN, CEC and clay mineral predictions are closely related to the occurrence of specific spectral bands in the MIR region. For example, wavelengths at 2978 and 1761 cm -1 for TOC and TN, as well as at 3064 cm -1 for CEC, were selected as the most influential predictor variables. We demonstrated that MIR spectroscopy is a powerful tool for more extensive monitoring in soils of the northern cold climate region; however, NIR could be utilized for rapid estimates when the highest accuracy is not essential.

54 ENVIRONMENTAL SCIENCES↗

Efficient marine environmental characterisation to support monitoring of geological CO 2 storage

Carbon capture and storage is key for mitigating greenhouse gas emissions, and offshore geological formations provide vast CO 2 storage potential. Monitoring of sub-seabed CO 2 storage sites requires that anomalies signifying a loss of containment be detected, and if attributed to storage, quantified and their impact assessed. However, monitoring at or above the seabed is only useful if one can reliably differentiate abnormal signals from natural variability. Baseline acquisition is the default option for describing the natural state, however we argue that a comprehensive baseline assessment is likely expensive and time-bound, given the multi-decadal nature of CCS operations and the dynamic heterogeneity of the marine environment. We present an outline of the elements comprising an efficient marine environmental baseline to support offshore monitoring. We demonstrate that many of these elements can be derived from pre-existing and ongoing sources, not necessarily related to CCS project development. We argue that a sufficient baseline can be achieved by identifying key emergent properties of the system rather than assembling an extensive description of the physical, chemical and biological states. Further, that contemporary comparisons between impacted and non-impacted sites are likely to be as valuable as before and after comparisons. Furthermore, as these emergent properties may be nuanced between sites and seasons and comparative studies need to be validated by the careful choice of reference site, a site-specific understanding of the scales of heterogeneity will be an invaluable component of a baseline.

54 ENVIRONMENTAL SCIENCES↗

Benchmarking CO₂ storage simulations: Results from the 11 th Society of Petroleum Engineers Comparative Solution Project

The 11 th Society of Petroleum Engineers Comparative Solution Project (shortened SPE11 herein) benchmarked simulation tools for geological carbon dioxide (CO 2 ) storage. A total of 45 groups from leading research institutions and industry across the globe signed up to participate, with 18 ultimately contributing valid results that were included in the comparative study reported here. This paper summarizes the SPE11 results. A comprehensive introduction and qualitative discussion of the submitted data are provided, together with an overview of online resources for accessing the full depth of data. A global metric for analyzing the relative distance between submissions is proposed and used to conduct a quantitative analysis of the submissions. This analysis attempts to statistically resolve the key aspects influencing the variability between submissions. The study shows that the major qualitative variation between the submitted results is related to thermal effects, dissolution-driven convective mixing, and resolution of facies discontinuities. Moreover, a strong dependence on grid resolution is observed across all three versions of the SPE11. However, our quantitative analysis suggests that the observed variations are predominantly influenced by factors not documented in the technical responses provided by the participants. We therefore identify that unreported variations due to human choices within the process of setting up, conducting, and reporting on the simulations underlying each SPE11 submission are at least as impactful as the computational choices reported.

Nordbotten, Jan M. [Univ. of Bergen (Norway); Norw↗

Prognostic Value of Survivin in Locally Advanced Prostate Cancer: Study Based on RTOG 8610

Purpose: To examine the prognostic value of nuclear and cytoplasmic survivin expression in men with locally advanced prostate cancer who were enrolled in Radiation Therapy Oncology Group (RTOG) protocol 8610. Methods and Materials: RTOG 8610 was a Phase III randomized study comparing the effect of radiotherapy plus short-term androgen deprivation with radiotherapy alone. Of the 456 eligible patients, 68 patients had suitably stained tumor material for nuclear survivin analysis and 65 patients for cytoplasmic survivin. Results: Compared with patients with nuclear survivin intensity scores of {<=}191.2, those with intensity scores >191.2 had significantly improved prostate cancer survival (hazard ratio [HR], 0.45; 95% confidence interval [CI], 0.20-1.00, p = 0.0452). On multivariate analysis, nuclear survivin intensity scores >191.2 were significantly associated with improved overall survival (HR, 0.46; 95% CI, 0.25-0.86; p = 0.0156) and prostate cancer survival (HR, 0.36; 95% CI, 0.16-0.84; p = 0.0173). On univariate analysis, compared with patients with cytoplasmic survivin integrated optical density {<=}82.7, those with an integrated optical density >82.7 showed a significantly increased risk of local progression (HR, 2.49; 95% CI, 1.03-6.01; p = 0.0421). Conclusion: Nuclear overexpression of survivin was associated with improved overall and prostate cancer survival on multivariate analysis, and cytoplasmic overexpression of survivin was associated with increased rate of local progression on univariate analysis in patients with locally advanced prostate cancer treated on RTOG 8610. Our results might reflect the different functions of survivin and its splice variants, which are known to exist in distinct subcellular compartments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer

Purpose: We conducted a comparative study of clinical target volume (CTV) definition of pelvic lymph nodes by multiple genitourinary (GU) radiation oncologists looking at the levels of discrepancies amongst this group. Methods and Materials: Pelvic computed tomography (CT) scans from 2 men were distributed to 14 Radiation Therapy Oncology Group GU radiation oncologists with instructions to define CTVs for the iliac and presacral lymph nodes. The CT data with contours were then returned for analysis. In addition, a questionnaire was completed that described the physicians' method for target volume definition. Results: Significant variation in the definition of the iliac and presacral CTVs was seen among the physicians. The minimum, maximum, mean (SD) iliac volumes (mL) were 81.8, 876.6, 337.6 {+-} 203 for case 1 and 60.3, 627.7, 251.8 {+-} 159.3 for case 2. The volume of 100% agreement was 30.6 and 17.4 for case 1 and 2 and the volume of the union of all contours was 1,012.0 and 807.4 for case 1 and 2, respectively. The overall agreement was judged to be moderate in both cases (kappa = 0.53 (p < 0.0001) and kappa = 0.48 (p < 0.0001). There was no volume of 100% agreement for either of the two presacral volumes. These variations were confirmed in the responses to the associated questionnaire. Conclusions: Significant disagreement exists in the definition of the CTV for pelvic nodal radiation therapy among GU radiation oncology specialists. A consensus needs to be developed so as to accurately assess the merit and safety of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Technologic Advances on Outcomes in Patients With Unresectable, Locally Advanced Non-Small-Cell Lung Cancer Receiving Concomitant Chemoradiotherapy

Purpose: In 2004, our institution began using four-dimensional computed tomography (4DCT) simulation and then intensity-modulated radiotherapy (IMRT) (4DCT/IMRT) instead of three-dimensional conformal radiotherapy (3DCRT) for the standard treatment of non-small-cell lung cancer (NSCLC). This retrospective study compares disease outcomes and toxicity in patients treated with concomitant chemotherapy and either 4DCT/IMRT or 3DCRT. Methods and Materials: A total of 496 NSCLC patients have been treated at M. D. Anderson Cancer Center between 1999 and 2006 with concomitant chemoradiotherapy. Among these, 318 were treated with CT/3DCRT and 91 with 4DCT/IMRT. Both groups received a median dose of 63 Gy. Disease end points were locoregional progression (LRP), distant metastasis (DM), and overall survival (OS). Disease covariates were gross tumor volume (GTV), nodal status, and histology. The toxicity end point was Grade >=3 radiation pneumonitis; toxicity covariates were GTV, smoking status, and dosimetric factors. Data were analyzed using Cox proportional hazards models. Results: Mean follow-up times in the 4DCT/IMRT and CT/3DCRT groups were 1.3 (range, 0.1-3.2) and 2.1 (range, 0.1-7.9) years, respectively. The hazard ratios for 4DCT/IMRT were <1 for all disease end points; the difference was significant only for OS. The toxicity rate was significantly lower in the IMRT/4DCT group than in the CT/3DCRT group. V20 was significantly higher in the 3DCRT group and was a significant factor in determining toxicity. Freedom from DM was nearly identical in both groups. Conclusions: Treatment with 4DCT/IMRT was at least as good as that with 3DCRT in terms of the rates of freedom from LRP and DM. There was a significant reduction in toxicity and a significant improvement in OS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Volumetric Modulated Arc Therapy and Conventional Intensity-Modulated Radiotherapy for Frontal and Temporal High-Grade Gliomas

Purpose: Volumetric modulated arc therapy (VMAT), the predecessor to Varian's RapidArc, is a novel extension of intensity-modulated radiotherapy (IMRT) wherein the dose is delivered in a single gantry rotation while the multileaf collimator leaves are in motion. Leaf positions and the weights of field samples along the arc are directly optimized, and a variable dose rate is used. This planning study compared seven-field coplanar IMRT (cIMRT) with VMAT for high-grade gliomas that had planning target volumes (PTVs) overlapping organs at risk (OARs). Methods and Materials: 10 previously treated patients were replanned to 60 Gy in 30 fractions with cIMRT and VMAT using the following planning objectives: 98% of PTV covered by 95% isodose without violating OAR and hotspot dose constraints. Mean OAR doses were maximally decreased without reducing PTV coverage or violating hotspot constraints. We compared dose-volume histogram data, monitor units, and treatment times. Results: There was equivalent PTV coverage, homogeneity, and conformality. VMAT significantly reduced maximum and mean retinal, lens, and contralateral optic nerve doses compared with IMRT (p < 0.05). Brainstem, chiasm, and ipsilateral optic nerve doses were similar. For 2-Gy fractions, mean monitor units were as follows: cIMRT = 789 +- 112 and VMAT = 363 +- 45 (relative reduction 54%, p = 0.002), and mean treatment times (min) were as follows: cIMRT = 5.1 +- 0.4 and VMAT = 1.8 +- 0.1 (relative reduction 65%, p = 0.002). Conclusions: Compared with cIMRT, VMAT achieved equal or better PTV coverage and OAR sparing while using fewer monitor units and less time to treat high-grade gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Comparison of Whole Brain Radiotherapy, 20 Gy in Four Daily Fractions Versus 40 Gy in 20 Twice-Daily Fractions, for Brain Metastases

Purpose: The present study compared the intracranial control rate and quality of life for two radiation fractionation schemes for cerebral metastases. Methods and Materials: A total of 113 patients with a Eastern Cooperative Oncology Group performance status <3; and stable (>2 months), absent, or concurrent presentation of extracranial disease were randomized to 40 Gy in 20 twice-daily fractions (Arm A) or 20 Gy in four daily fractions (Arm B), stratified by resection status. The European Organization for Research and Treatment of Cancer Quality of Life 30-item questionnaire was administered monthly during Year 1, bimonthly during Year 2, and then every 6 months to Year 5. Results: The patient age range was 28-83 years (mean 62). Of the 113 patients, 41 had undergone surgical resection, and 74 patients had extracranial disease (31 concurrent and 43 stable). The median survival time was 6.1 months in Arm A and 6.6 months in Arm B, and the overall 5-year survival rate was 3.5%. Intracranial progression occurred in 44% of Arm A and 64% of Arm B patients (p = .03). Salvage surgery or radiotherapy was used in 4% of Arm A patients and 21% of Arm B patients (p = .004). Death was attributed to central nervous system progression in 32% of patients in Arm A and 52% of patients in Arm B (p = .03). The toxicity was minimal, with a minor increase in short-term cutaneous reactions in Arm A. The patients' quality of life was not impaired by the more intense treatment in Arm A. Conclusion: Intracranial disease control was improved and the quality of life was maintained with 40 Gy in 20 twice-daily fractions. This schema should be considered for better prognosis subgroups of patients with cerebral metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Whole-Brain Radiotherapy for Multiple Brain Metastases From Transitional Cell Carcinoma of the Bladder

Purpose: Brain metastases in bladder cancer patients are extremely rare. Most patients with multiple lesions receive longer-course whole-brain radiotherapy (WBRT) with 10 x 3 Gy/2 weeks or 20 x 2 Gy/4 weeks. Because its radiosensitivity is relatively low, metastases from bladder cancer may be treated better with hypofractionated radiotherapy. This study compared short-course hypofractionated WBRT (5 x 4 Gy/1 week) to longer-course WBRT. Methods and Materials: Data for 33 patients receiving WBRT alone for multiple brain metastases from transitional cell bladder carcinoma were retrospectively analyzed. Short-course WBRT with 5 x 4 Gy (n = 12 patients) was compared to longer-course WBRT with 10 x 3 Gy/20 x 2 Gy (n = 21 patients) for overall survival (OS) and local (intracerebral) control (LC). Five additional potential prognostic factors were investigated: age, gender, Karnofsky performance score (KPS), number of brain metastases, and extracranial metastases. The Bonferroni correction for multiple tests was used to adjust the p values derived from the multivariate analysis. p values of <0.025 were considered significant. Results: At 6 months, OS was 42% after 5 x 4 Gy and 24% after 10 x 3/20 x 2 Gy (p = 0.31). On univariate analysis, improved OS was associated with less than four brain metastases (p = 0.021) and almost associated with a lack of extracranial metastases (p = 0.057). On multivariate analysis, both factors were not significant. At 6 months, LC was 83% after 5 x 4 Gy and 27% after 10 x 3/20 x 2 Gy (p = 0.035). Improved LC was almost associated with a KPS of {>=}70 (p = 0.051). On multivariate analysis, WBRT regimen was almost significant (p = 0.036). KPS showed a trend (p = 0.07). Conclusions: Short-course WBRT with 5 x 4 Gy should be seriously considered for most patients with multiple brain metastases from bladder cancer, as it resulted in improved LC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy Reduces Gastrointestinal Toxicity in Patients Treated With Androgen Deprivation Therapy for Prostate Cancer

Purpose: Androgen deprivation therapy (AD) has been shown to increase late Grade 2 or greater rectal toxicity when used concurrently with three-dimensional conformal radiotherapy (3D-CRT). Intensity-modulated radiotherapy (IMRT) has the potential to reduce toxicity by limiting the radiation dose received by the bowel and bladder. The present study compared the genitourinary and gastrointestinal (GI) toxicity in men treated with 3D-CRT+AD vs. IMRT+AD. Methods and Materials: Between July 1992 and July 2004, 293 men underwent 3D-CRT (n = 170) or IMRT (n = 123) with concurrent AD (<6 months, n = 123; {>=}6 months, n = 170). The median radiation dose was 76 Gy for 3D-CRT (International Commission on Radiation Units and Measurements) and 76 Gy for IMRT (95% to the planning target volume). Toxicity was assessed by a patient symptom questionnaire that was completed at each visit and recorded using a Fox Chase Modified Late Effects Normal Tissue Task radiation morbidity scale. Results: The mean follow-up was 86 months (standard deviation, 29.3) for the 3D-CRT group and 40 months (standard deviation, 9.7) for the IMRT group. Acute GI toxicity (odds ratio, 4; 95% confidence interval, 1.6-11.7; p = .005) was significantly greater with 3D-CRT than with IMRT and was independent of the AD duration (i.e., <6 vs. {>=}6 months). The interval to the development of late GI toxicity was significantly longer in the IMRT group. The 5-year Kaplan-Meier estimate for Grade 2 or greater GI toxicity was 20% for 3D-CRT and 8% for IMRT (p = .01). On multivariate analysis, Grade 2 or greater late GI toxicity (hazard ratio, 2.1; 95% confidence interval, 1.1-4.3; p = .04) was more prevalent in the 3D-CRT patients. Conclusion: Compared with 3D-CRT, IMRT significantly decreased the acute and late GI toxicity in patients treated with AD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

True Recurrence Versus New Primary: An Analysis of Ipsilateral Breast Tumor Recurrences After Breast-Conserving Therapy

Purpose: Ipsilateral breast tumor recurrence (IBTR) can occur in 5-20% of women with early-stage breast cancer treated with breast-conserving therapy. Two entities of IBTR have been described: true recurrence (TR), suggested to be regrowth of disease at the tumor bed, and new primary (NP), distinct from the index lesion in histology and location. This study compared survival outcomes between two patient cohorts classified clinically as having either TR or NP. Methods and Materials: Between 1989 and 1999, 6,020 women were referred to the BC Cancer Agency with newly diagnosed pT1-2, N0-1, M0 invasive breast cancer, treated with breast-conserving surgery. Of these, 289 patients had pathologically confirmed IBTR. Retrospective analysis was performed, and a set of decision rules was applied to classify cases as TR or NP based on change in histology, grade, hormone receptor status, and tumor location. Of 289 patients, 129 (45%) were classified as having TR and 139 (48%) as having NP; 21 (7%) were unclassified. Results: The distributions of age at diagnosis, age at recurrence, and histopathologic factors were similar in the TR and NP cohorts (all p > 0.05). The mean time to recurrence was shorter in TR patients than in NP patients (4.8 years vs. 6.3 years, p = 0.001). Treatment of the IBTR did not differ between the two groups. In the TR and NP cohorts, breast cancer-specific survival was 55.7% vs. 61.3% (p = 0.93), and overall survival was 43.7% vs. 54.8% (p = 0.53). Conclusions: Time to recurrence is significantly shorter in patients with IBTR classified as true recurrence compared to new primary. Non-statistically significant trends for less favorable survival were observed for patients with TR. Further investigation of the hypothesis that TR and NP tumors are distinct entities with different survival prognoses will require standardized pathology review and molecular analyses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Interindividual Comparison of O-(2- [{sup 18}F]Fluoroethyl)-L-Tyrosine (FET)- and L-[Methyl-{sup 11}C]Methionine (MET)-PET in Patients With Brain Gliomas and Metastases

Purpose: L-[methyl-{sup 11}C]methionine (MET)-positron emission tomography (PET) has a high sensitivity and specificity for imaging of gliomas and metastatic brain tumors. The short half-life of {sup 11}C (20 minutes) limits the use of MET-PET to institutions with onsite cyclotron. O-(2- [{sup 18}F]fluoroethyl)-L-tyrosine (FET) is labeled with {sup 18}F (half-life, 120 minutes) and could be used much more broadly. This study compares the uptake of FET and MET in gliomas and metastases, as well as treatment-induced changes. Furthermore, it evaluates the gross tumor volume (GTV) of gliomas defined on PET and magnetic resonance imaging (MRI). Methods and Materials: We examined 42 patients with pretreated gliomas (29 patients) or brain metastases (13 patients) prospectively by FET- and MET-PET on the same day. Uptake of FET and MET was quantified by standardized uptake values. Imaging contrast was assessed by calculating lesion-to-gray matter ratios. Tumor extension was quantified by contouring GTV in 17 patients with brain gliomas. Gross tumor volume on PET was compared with GTV on MRI. Sensitivity and specificity of MET- and FET-PET for differentiation of viable tumor from benign changes were evaluated by comparing the PET result with histology or clinical follow-up. Results: There was a strong linear correlation between standardized uptake values calculated for both tracers in cortex and lesions: r = 0.78 (p = 0.001) and r = 0.84 (p < 0.001), respectively. Image contrast was similar for MET- and FET-PET (lesion-to-gray matter ratios of 2.36 {+-} 1.01 and 2.33 {+-} 0.77, respectively). Mean GTV in 17 glioma patients was not significantly different on MET- and FET-PET. Both MET- and FET-PET delineated tumor tissue outside of MRI changes. Both tracers provided differentiated tumor tissue and treatment-related changes with a sensitivity of 91% at a specificity of 100%. Conclusions: O-(2- [{sup 18}F]fluoroethyl)-L-tyrosine-PET and MET-PET provide comparable diagnostic information on gliomas and brain metastases. Like MET-PET, FET-PET can be used for differentiation of residual or recurrent tumor from treatment-related changes/pseudoprogression, as well as for delineation of gliomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy Boost for Prostate Cancer: Comparison of Two Different Fractionation Schemes

Purpose: This is a retrospective study comparing our experience with high-dose-rate (HDR) brachytherapy boost for prostate cancer, using two different fractionation schemes, 600 cGy Multiplication-Sign 3 fractions (patient group 1) and 950 cGy Multiplication-Sign 2 fractions (patient group 2). Methods and Materials: A total of 165 patients were treated for prostate cancer using external beam radiation therapy up to a dose of 45 Gy, followed by an HDR brachytherapy prostate radiation boost. Between July 1997 and Nov 1999, 64 patients were treated with an HDR boost of 600 cGy Multiplication-Sign 3 fractions; and between June 2000 and Nov 2005, 101 patients were treated with an HDR boost of 950 cGy Multiplication-Sign 2 fractions. All but 9 patients had at least one of the following risk features: pretreatment prostate-specific antigen (PSA) level >10, a Gleason score {>=}7, and/or clinical stage T3 disease. Results: Median follow-up was 105 months for group 1 and 43 months for group 2. Patients in group 2 had a greater number of high-risk features than group 1 (p = 0.02). Adjusted for comparable follow-up, there was no difference in biochemical no-evidence-of-disease (bNED) rate between the two fractionation scheme approaches, with 5-year Kaplan-Meier estimates of 93.5% in group 1 and 87.3% in group 2 (p = 0.19). The 5-year estimates of progression-free survival were 86% for group 1 and 83% for group 2 (p = 0.53). Among high-risk patients, there were no differences in bNED or PFS rate due to fractionation. Conclusions: Results were excellent for both groups. Adjusted for comparable follow-up, no differences were found between groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Single-Arc Intensity-Modulated Arc Therapy: A Collaborative Dosimetric Comparison Between Two Institutions

Purpose: Both helical tomotherapy (HT) and single-arc intensity-modulated arc therapy (IMAT) deliver radiation using rotational beams with multileaf collimators. We report a dual-institution study comparing dosimetric aspects of these two modalities. Methods and Materials: Eight patients each were selected from the University of Maryland (UMM) and the University of Wisconsin Cancer Center Riverview (UWR), for a total of 16 cases. Four cancer sites including brain, head and neck (HN), lung, and prostate were selected. Single-arc IMAT plans were generated at UMM using Varian RapidArc (RA), and HT plans were generated at UWR using Hi-Art II TomoTherapy. All 16 cases were planned based on the identical anatomic contours, prescriptions, and planning objectives. All plans were swapped for analysis at the same time after final approval. Dose indices for targets and critical organs were compared based on dose-volume histograms, the beam-on time, monitor units, and estimated leakage dose. After the disclosure of comparison results, replanning was done for both techniques to minimize diversity in optimization focus from different operators. Results: For the 16 cases compared, the average beam-on time was 1.4 minutes for RA and 4.8 minutes for HT plans. HT provided better target dose homogeneity (7.6% for RA and 4.2% for HT) with a lower maximum dose (110% for RA and 105% for HT). Dose conformation numbers were comparable, with RA being superior to HT (0.67 vs. 0.60). The doses to normal tissues using these two techniques were comparable, with HT showing lower doses for more critical structures. After planning comparison results were exchanged, both techniques demonstrated improvements in dose distributions or treatment delivery times. Conclusions: Both techniques created highly conformal plans that met or exceeded the planning goals. The delivery time and total monitor units were lower in RA than in HT plans, whereas HT provided higher target dose uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗