Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Adaptive Solar Energy and Power Storage Platform for Multimetered Properties

Veritel Energy LLC has successfully demonstrated the feasibility of its innovative adaptive solar energy and power storage platform designed for multimetered properties in Phase I of its DOE SBIR grant. The project centered around the development and initial deployment of proprietary hardware and software system that manages and distributes site-generated renewable energy to multiple tenants efficiently. This system integrates seamlessly with existing building infrastructure and utility systems, making it a viable solution for aging multifamily properties often located in at-risk communities. The pilot system was installed in a multifamily building with a single master-meter, and functioned as a pilot to demonstrate a scalable model for renewable energy system adoption across similar properties. This installation not only showed potential for significant reductions in greenhouse gas emissions but also improved the economic viability of renewable installations by allowing property owners to recoup investments through increased energy savings and tenant billing. The Phase I project set the groundwork for further enhancements and testing in Phase II which will aim to apply the technology to projects with dozens of sub-meters, further contributing to the decarbonization of the built environment.

14 SOLAR ENERGY↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Updating Nuclear Energy Cost Estimates for Net Zero World Initiative

Energy modeling of decarbonized scenarios in integrated energy systems requires nuclear energy parameters that are critical for forecasting, modeling and cost structure analysis. Using updated real-world data has always been a challenge to estimate current nuclear reactors costs and deployment scenarios. Given this, an updated set of parameters for overnight capital costs and operation and maintenance costs are estimated for the Net Zero World initiative using recent reports that provided a vast set of open sources data inputs. This paper follows the methodology developed in the Net Zero World report and applies the new ranges estimated in the Gateway for Accelerated Innovation in Nuclear report that address many of the current challenges in obtaining accurate cost data for advanced nuclear concepts. The final goal is to provide new estimates of the overnight capital costs and operational costs for different countries. The present paper improves the earlier capital cost estimations, building on recent literature that aims to obtain accurate data for modeling and simulation to enhance energy system evaluations and support decision-making in areas like de-carbonization and capacity expansion. Finally, the paper compares the new cost estimates with the old cost results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Angular selective window systems: Assessment of technical potential for energy savings

Static angular selective shading systems block direct sunlight and admit daylight within a specific range of incident solar angles. The objective of this study is to quantify their potential to reduce energy use and peak demand in commercial buildings using state-of-the art whole-building computer simulation software that allows accurate modeling of the behavior of optically-complex fenestration systems such as angular selective systems. Three commercial systems were evaluated: a micro-perforated screen, a tubular shading structure, and an expanded metal mesh. This evaluation was performed through computer simulation for multiple climates (Chicago, Illinois and Houston, Texas), window-to-wall ratios (0.15-0.60), building codes (ASHRAE 90.1-2004 and 2010) and lighting control configurations (with and without). The modeling of the optical complexity of the systems took advantage of the development of state-of-the-art versions of the EnergyPlus, Radiance and Window simulation tools. Results show significant reductions in perimeter zone energy use; the best system reached 28% and 47% savings, respectively without and with daylighting controls (ASHRAE 90.1-2004, south facade, Chicago,WWR=0.45). As a result, angular selectivity and thermal conductance of the angle-selective layer, as well as spectral selectivity of low-emissivity coatings, were identified as factors with significant impact on performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrifying High-Efficiency Future Communities: Impact on Energy, Emissions, and Grid

To combat climate change and meet decarbonization goals, the building sector is improving energy efficiency and electrifying end uses to reduce carbon emissions from fossil fuels. All-electric buildings are becoming a trend among new constructions, introducing opportunities for decarbonization but also technical challenges and research gaps. For instance, further investigation is needed to understand how the adoption of energy efficiency measures (EEMs) and distributed energy resources (DERs) in all-electric communities would affect energy consumption, carbon emissions, and grid planning. This paper presents a case study of a mixed-use, all-electric community located in Denver, Colorado. We use URBANopt TM , a physics-based urban energy modeling platform to model the community and then evaluate the impact of EEMs and DERs (i.e., photovoltaics [PV], electric vehicles [EVs], and batteries) on the community's energy usage, carbon emissions, and peak demand. The results show that adding EEMs and PV led to both energy consumption and carbon emissions reductions across all building types. However, we saw fairly limited impact of EEMs and PV on buildings' peak demand in our case. Additionally, due to overnight EV charging activities and higher grid carbon intensity at night, the carbon emissions in multifamily buildings have a noticeable increase compared to scenarios without vehicles. Finally, the addition of batteries helped reduce peak demand by 11%-29%. The modeling workflow and evaluation methods can be applied to similar communities to evaluate their performance and the effect of integrating EEMs and DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RM3 Wave Tank Validation Model

An approximately 1/75th scale point absorber wave energy absorber was built to validate the testing systems of a 16k gallon single paddle wave tank. The model was build based on the RM3 design and incorporated a linear position sensor, a force transducer, and wetness detection sensors. The data set also includes motion tracking data of the device's two bodies acquired from 4x Qualisys cameras. The tank wave spectrum is measured by 4 ultrasonic water height sensors.

16 TIDAL AND WAVE POWER↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

A Physical Model Enhanced Data Driven Method for High-Resolution Residential Load Profile Generation

Residential buildings account for significant energy consumption, creating opportunities to offer grid services. As electric utilities seek to implement effective system operation strategies, understanding residential energy consumption patterns becomes essential; However, the time intervals of load profiles measured by utilities' smart meters are typically from 15 minutes to 60 minutes. The low-resolution data make it hard to extract appliance-level load information, which is critical for providing grid services. This paper presents a load profile generator designed to produce synthetic load profiles for residential buildings that emphasizes the importance of accurate representations of realistic energy consumption patterns. The generator takes realistic low-resolution residential load measurements and weather data as inputs, producing 1-minute interval profiles that match the characteristics of the original profiles. Further, this generator can be used to populate load profiles in areas where actual measurements are limited to improve the ability of utilities to analyze their distribution systems. By providing more high-resolution residential building load profiles, this tool supports electric utilities to enhance their residential building load control strategies and improve overall grid stability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Building Partners Catalyze High Performance Buildings Across the Nation

In 2008 the US Department of Energy (DOE) launched the Commercial Buildings Partnership (CBP) project to accelerate market adoption of commercially available energy saving technologies into the design process for new and upgraded commercial buildings. The CBP represents a unique collaboration between industry leaders and DOE to develop high performance buildings as a model for future construction and renovation. CBP was implemented in two stages. This paper focuses on lessons learned at Pacific Northwest National Laboratory (PNNL) in the first stage and discusses some partner insights from the second stage. In the first stage, PNNL and the National Renewable Energy Laboratory recruited CBP partners that own large portfolios of buildings. The labs provide assistance to the partners' design teams and make a business case for energy investments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Battery Modeling for Control-Oriented Techno-Economic Studies: Preprint

Electrochemical batteries, which serve as electric energy storage devices, are becoming increasingly popular among residential buildings that incorporate solar photovoltaic (PV) systems to help meet their energy needs. Battery economics are affected by performance degradation over time, and managing this degradation can help extend the battery's lifespan. The tradeoff between operational costs/benefits and managing battery degradation is of significant research interest. One of the key factors for assessing battery degradation is the dispatch strategy used to control the charging and discharging of the battery. Conventional dispatch strategies typically use simple rule-based methods, and these overly aggressive charging/discharging cycles can significantly reduce a battery’s life span. Our research seeks to develop optimized dispatch strategies for grid-connected PV homes with a goal of extending battery life while simultaneously taking into consideration utility costs and occupant comfort. To achieve this goal, we adapted lithium-ion battery life- and cyclic-degradation models for use in high-fidelity building simulations, so whole-building and grid-interactive controllers can dispatch the batteries along with other flexible loads. With the help of a co-simulation platform, we performed a simulation study to compute the optimized dispatch strategies for relevant operating conditions brought about by changing geographical locations, weather conditions, and utility pricing. Comparing the optimized strategies with the conventional strategies resulted in a >50% decrease in capacity degradation and >10% average reduction in operational costs during the months of January and July in Fort Collins, Colorado; Phoenix, Arizona; and Portland, Oregon.

30 DIRECT ENERGY CONVERSION↗

Model predictive control for active insulation in building envelopes

Active insulation systems (AISs) refer to building envelopes with insulation materials that can change their thermal conductivity and are coupled with thermal mass to reduce building energy consumption and peak power. In this research, a novel optimal control approach is proposed to evaluate the maximum theoretical energy and cost-saving potential of AISs. A time-varying model predictive control (TV-MPC) controller was used to optimally select the AIS mode and simultaneously determine the operation of the heating, ventilation and air conditioning (HVAC) system so that the maximum saving potential of the entire system can be realized. To comprehensively evaluate the power shifting flexibility of AISs, two optimization objectives—minimizing weekly electric energy consumption and minimizing weekly electricity cost—were considered. The summer season simulation results show that under the first objective, more than 50% electric and thermal energy was saved when the upper boundary of the indoor air temperature was set to 25 °C. Furthermore under the second optimization objective, 38% of the cost was saved. It can be expected that the developed approach can be easily applied to multiple types of AISs with different mechanisms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MO-FG-303-02: BEST IN PHYSICS (THERAPY): Cherenkov Emission Dosimetry: Feasibility for Electron Radiotherapy

Purpose: To investigate from first principles, corroborated by Monte Carlo simulations and experimental measurements, the feasibility of developing a relative Cherenkov emission (CE) dosimetry protocol for electron beam radiotherapy. Methods: Monte Carlo (MC) simulations of mono-energetic electrons incident on water were carried out in Geant4. Percent depth Cherenkov emission (PDCE) and dose (PDD) distributions were scored for incidence energies of 4, 6, 9, 12, 15, and 18 MeV. PDCE-to-PDD analytical conversion models were developed from least-squares data fits generated for PDD as a function of PDCE at the same depth and at different depths. Experimental techniques for validation of these models are examined. Results: Same-depth PDD versus PDCE data fits indicate that although the relationship is linear to first order (correlation r > 0.9 for all energies), it is much more accurately approximated by separate linear and quadratic models for the build-up and drop-off regions, respectively (r > 0.999), which is theoretically underpinned. To understand the source of this relationship and its basis for developing robust conversion models, an approximate quadratic first-principles model was derived and found in agreement with MC/measured data (20% deviation at worst). Conversely, data fits of PDD versus different-depth PDCE unveiled a depth-invariant effective point of measurement of 1.5–2.1 mm downstream with 4–18 MeV incidence, respectively (r > 0.999 in the drop-off region). We present an analytical first-principles justification for this shift. This method led to errors of <1% in drop-off region PDD (<2% for PDD<20% with 4 MeV incidence) and <0.2 mm in practical range prediction. Conclusion: We present robust quantitative prediction models, derived from first-principles and supported by simulation and measurement, for relative dose from Cherenkov emission by high-energy electrons. This constitutes a major step towards development of protocols for routine clinical quality assurance as well as real-time in vivo Cherenkov dosimetry in radiotherapy. The authors acknowledge partial support by Fonds de recherche du Quebec - Nature et technologies (FRQNT), CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (NSERC), CREATE Integrated Sensor Systems grant of NSERC, the Canadian Institutes of Health Research (CIHR), and NSERC.

60 APPLIED LIFE SCIENCES↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

A physics-informed data-driven low order model for the wind velocity deficit at the wake of isolated buildings

Detailed simulations of the Atmospheric boundary layer (ABL) provides information on wind velocity, direction and turbulence for optimizing the design of wind turbines and wind farms and their operations. Distributed wind turbines have been considered for use in urban or suburban areas for covering energy needs using a sustainable energy solution. Simulations of high Reynolds number turbulent ABL flows past obstacles can be used for the prediction of the velocity deficit and turbulence characteristics in the leeward side of building-like obstacles, allowing for the estimation of power losses and fatigue loads in wind turbines. However, fully three-dimensional simulations of high Reynolds number ABL flows using Large Eddy Simulation (LES) or Reynolds Average Navier-Stokes Simulations (RANS) continue to require large computational/ execution times. As a result, these 3D simulations may not be ideal tools for the rapid assessment of wind energy potential. In the present study, 3D numerical results from wall resolved RANS simulations were used for the development of a low order model that allows the rapid assessment of wind velocity and turbulence in the leeward side of an isolated building.

17 WIND ENERGY↗

Multifamily Envelope Leakage Model

The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Multifamily Envelope Leakage Model

“The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deter program participants, and dissuade them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.” This statement found in a 2012 report by Heschong Mahone Group for several California interests emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing—the more appropriate test for assessing energy savings opportunities—could easily be six times that, and that’s only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. This research seeks to provide an algorithm for predicting the guarded blower door test result based upon a single, total blower door test.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗