Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Revisions of ORNL 188 W Process Based on Nonradiological Experiments

Tungsten-188 is in widespread use in the 188 W(t 1/2 = 69 d)/ 188 Re(t 1/2 =16.9 h) biomedical generator. Oak Ridge National Laboratory (ORNL) has been providing this product to the world since 1999. At ORNL, 188 W is produced via irradiation in ORNL’s High Flux Isotope Reactor (HFIR). Enriched 186 W targets in the form of sintered metallic pellets or rings achieve a compact loading in the irradiation vessel, providing a high yield per unit target. The enrichment of the target is >90% 186 W and this isotope undergoes double neutron capture to produce the desired 188W product. While 188 W is produced by neutron bombardment, 191 Os(t 1/2 = 15.4 d) is simultaneously produced as a byproduct requiring separation from 188 W by post irradiation treatment. In the current processing pathway, the irradiated W metal pellets or rings are first converted into an oxide form of WO 3 by heating the irradiated W metal target at 750°C in a quartz reaction vessel inside a vertical furnace under a constant flow of air. During heating, W metal reacts with oxygen in the air to produce WO 3 , which is soluble in 6 M NaOH for later purification process. This oxidation process also converts 188 Os (the decay daughter of 188 W) and 191 Os (the irradiation produced byproduct) into OsO 4 , a highly volatile and toxic gas. The gaseous effluents driven from the quartz reaction vessel are passed through a scrubbing array to remove OsO 4 before the air is discharged from the process. This heterogeneous oxidation method simultaneously achieves two goals: 1). converting metal target to a soluble oxide form and 2). separating volatile OsO 4 away from the solid WO 3 product, although harmful 191 OsO 4 is unfavorable but being taken care of by the down road scrubbing array. In the past twenty years the existing OsO 4 scrubbing array served well in preventing OsO 4 from being released into the environment, until July of 2020 when a minor amount of 191 Os was found to have been released into the environment which resulted in a standby of building 4501 from July 2020 to February 2021.Since October 20 of 2020 a team of researchers from groups of RSTD and NEFD were organized to work for the following tasks: (1) Fully understand the root causes of the July incident of 191 Os release and create a redesigned 191 Os scrubbing array to eliminate the possibility of 191 Os release in future 188 W processes; (2) In Phase-1 tests, select a correct air (O 2 ) flow rate in 188 W process, that provides sufficient oxygen for the oxidation of tungsten metal, while still allowing sufficient resonance time for 191 Os removal by the scrubbers; (3) In Phase-2 tests, confirm the efficiency of the redesigned scrubbing array to absorb excessive amount of non-rad OsO 4 (generated from Os metal powder) at the selected air flow; (4) In Phase-3 tests, simulate the hot cell 188 W process by heating pressed non-rad W-Os pellets in a quartz vessel of new design and the new array under operation parameters selected in Phase-1 and -2; (5) Complete a new operation procedure for 188 W process in hot cell and a TM report as a summary of the Os Mitigation Project. This TM report summarizes the investigation on root causes from technical aspects in July 191 Os release and the correspondent improvement towards the redesigned 191 Os scrubbing system. The report presents the efforts made on selection of optimal operational parameter with the new scrubbing array and the quartz vessel of new design, based on experiment data obtained in Phase-1, -2 and -3 tests. Further renovations for 188 W process and additional improvement of W target treatment will also be discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Uranium Oxide Elutriation at Higher Flow Rates and Longer Times

This work supports the recovery of high-assay low-enriched uranium (i.e., U enriched in 235 U to >5% and <20%) from used nuclear fuel. One step includes elutriating triuranium octoxide (U 3 O 8 ) from a fluidized bed of alumina (Al 2 O 3 ) that fills the main reaction chamber. The experiments outlined in this report assessed the effects of the time and flow rate on the elutriation of U 3 O 8 powder from the reaction vessel. Testing at Oak Ridge National Laboratory (ORNL) was performed in a one-fourth scale experimental apparatus based on a pilot-scale system, which is the Material Recovery Pilot Plant (MRPP) at Idaho National Laboratory (INL). The experimental system comprises a supply of pressurized nitrogen (N 2 ), a gas heater, the reaction vessel, a knock-out pot, and a water trap where elutriated particles are collected for sampling. An Al 2 O 3 fluidized bed is contained within the reaction vessel. A bed of Al 2 O 3 with a nominal size of 180 µm and U 3 O 8 with a nominal size of 7 µm was fluidized at 2 different flow rates so the U 3 O 8 physically separated from the bed. The apparatus was simple and had no valves or sharp bends downstream from the reactor. The flow exited the reactor through a side port at the top. The flow passed through a knock-out vessel before the flow was passed through a bubbler to capture the U 3 O 8 . Seven tests were completed with U 3 O 8 using an elutriating gas of N 2 heated to 200°C. Tests were performed with bed loadings that comprise 25.0 g of U 3 O 8 , or 3.6 wt% of the bed mass. Except for one test performed at 12 SLPM, the gas flow rate through the bed for the other experiments was set at 10 SLPM as measured by the mass flow meter. Linear velocities through the bed were calculated as 28 and 34 cm/s, or 0.9 and 1.1 ft·s -1 . The duration of the tests ranged from 20 to 180 min, and one test had a flow cycled between 0 and 5 SLPM every 5 min for 40 min. The testing successfully demonstrated elutriation of U 3 O 8 from the fluidized bed as up to a 100% of the U 3 O 8 was transferred out of the bed. The removal of U 3 O 8 had a logarithmic dependence on flow rate. The design changes made the apparatus easier to clean, and the mass balances were better than those used in previous studies. Some elutriated Al 2 O 3 collected in the tubing that connected the reactor to the knock-out pot, but the amount of Al 2 O 3 was minimal for 10 SLPM. The flow at 12 SLPM showed considerable transport of Al 2 O 3 bed material into the reaction-vessel headspace and the transfer line to the knock-out pot.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Annual report for DOE VTO

Carbon fiber (CF)/polymer composites are a transformative class of high-performance, lightweight material, where high aspect-ratio CFs reinforce a polymer matrix and exceed the strength of steel alloys at a fraction of the density. Despite the advantages of such a class of material, the broader implementation of CF composites in a range of automotive, aerospace, and energy applications is hindered by limitations of current manufacturing methods. These current techniques (e.g., hand lay-up, wet filament winding) are costly and impose severe limitations on fiber placement, orientation, and angle, and thus a composite’s ultimate properties. Today’s CF composites are expensive to manufacture, limited in form factor, and utilize costly and sub-optimal continuous filament CF. Advanced additive manufacturing (AM) processes, combined with computational design optimization and new approaches to resin development, offer alternative design and manufacturing paradigms that have the realistic potential to lift these constraints. Such integrated AM approaches could thus help to realize the full potential of CF composite materials. One relevant application of CF composite materials where manufacturing constraints limit the cost-benefit ratio is in the manufacture of high-performance composite pressure vessels for onboard compressed natural gas (CNG) storage. Current CNG storage vessels (Types 3–5) are made from load-bearing filament-wound carbon-fiber composite and are ~3.5 times as expensive as an all-metallic Type-1 vessel. This cost is invariably tied to the complex and labor-intensive nature of conventional filament winding processes and the large volumes of expensive high tensile-strength CF tow feedstock required in manufacture. Our proposed approach to CNG storage vessel manufacture is based on a combination of AM technologies for CF composite printing and design optimization tools that were pioneered at Lawrence Livermore National Laboratory (LLNL), with advances in resin/composite formulation enabled by chemical and nano-material modification. Through the successful development of this technology, LLNL seeks to demonstrate the capability for advanced CNG storage vessel manufacture at reduced cost with no reduction in performance versus the most advanced, extant Type-5 designs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Maritime Interdiction Operations Small Craft Detection

The Naval Postgraduate School has been conducting Tactical Network Topology (TNT) Maritime Interdiction Operations (MIO) experiments with Lawrence Livermore National Laboratory (LLNL) since early in 2005. In this work, we are investigating cutting edge technology to evaluate use of networks, advanced sensors and collaborative technology for globally-supported maritime interdiction operations. Some examples of our research include communications in harsh environments, between moving ships at sea; small boat drive-by radiation detection; network-centric collaboration with global partners; situational awareness; prototype sensors & biometric instruments. Since 2006, we have studied the concept of using a small vessel with fixed radiation sensors to do initial searches for illicit radioactive materials. In our work, we continue to evaluate concepts of operation for small boat monitoring. For example, in San Francisco Bay we established a simulated choke point using two RHIBs. Each RHIB had a large sodium iodide radiation sensor on board, mounted on the side nearest to the passing potential target boats. Once detections were made, notification over the network prompted a chase RHIB also equipped with a radiation sensor to further investigate the potential target. We have also used an unmanned surface vessel (USV) carrying a radiation sensor to perform the initial discovery. The USV was controlled remotely and to drive by boats in different configurations. The potential target vessels were arranged in a line, as a choke point and randomly spaced in the water. Search plans were problematic when weather, waves and drift complicated the ability to stay in one place. A further challenge is to both detect and identify the radioactive materials during the drive-by. Our radiation detection system, ARAM, Adaptable Radiation Area Monitor, is able to detect, alarm and quickly identify plausible radionuclides in real time. We have performed a number of experiments to better understand parameters of vessel speed, time, shielding, and distance in this complex three-dimensional space. At the NMIOTC in September 2009, we employed a dual detector portal followed by a chase. In this event, the challenge was to maintain communications after a lapse. When the chase went past the line-of sight reach of the Tactical Operational Center's (TOC) antenna, with interference from a fortress island in Suda Bay, Wave Relay extended the network for continued observation. Sodium iodide radiation detectors were mounted on two Hellenic Navy SEAL fast boats. After making the detection one of the portal boats maintained line-of sight while the other pursued the target vessel. Network access via Wave Relay antennas was maintained until the conclusion of the chase scenario. Progress has been made in the detection of radioactive materials in the maritime environment. The progression of the TNT MIO experiments has demonstrated the potential of the hardware to solve the problems encountered in this physically challenging environment. There continue to be interesting opportunities for research and development. These experiments provide a variety of platforms and motivated participants to perform real-world testing as solutions are made available.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Modular Tissue Phantom for Evaluating Vascular Access Devices

Central vascular access (CVA) may be critical for trauma care and stabilizing the casualty. However, it requires skilled personnel, often unavailable during remote medical situations and combat casualty care scenarios. Automated CVA medical devices have the potential to make life-saving therapeutics available in these resource-limited scenarios, but they must be properly designed. Unfortunately, currently available tissue phantoms are inadequate for this use, resulting in delayed product development. Here, we present a tissue phantom that is modular in design, allowing for adjustable flow rate, circulating fluid pressure, vessel diameter, and vessel positions. The phantom consists of a gelatin cast using a 3D-printed mold with inserts representing vessels and bone locations. These removable inserts allow for tubing insertion which can mimic normal and hypovolemic flow, as well as pressure and vessel diameters. Trauma to the vessel wall is assessed using quantification of leak rates from the tubing after removal from the model. Lastly, the phantom can be adjusted to swine or human anatomy, including modeling the entire neurovascular bundle. Overall, this model can better recreate severe hypovolemic trauma cases and subject variability than commercial CVA trainers and may potentially accelerate automated CVA device development.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetocaloric pump

A vessel having inlet and outlet valves is disposed in a container with a fluid to be pumped which may be evolved from a liquid in the container below the vessel. A magnetocaloric substance is disposed in the vessel and causes fluid vapor in the vessel to expand and be expelled through the outlet valve. Vapor is drawn in through the inlet valve as the substance cools. The inlet valves may be one-way check valves or may be solenoid valves energized at appropriate times by timing circutis. A timer controlled heating element may also be disposed in the vessel to operate in conjunction with the magnetic field.

Brown, G. V.↗

Hollow fiber clinostat for simulating microgravity in cell culture

A clinostat for simulating microgravity on cell systems carried in a fiber fixedly mounted in a rotatable culture vessel is disclosed. The clinostat is rotated horizontally along its longitudinal axis to simulate microgravity or vertically as a control response. Cells are injected into the fiber and the ends of the fiber are sealed and secured to spaced end pieces of a fiber holder assembly which consists of the end pieces, a hollow fiber, a culture vessel, and a tension spring with three alignment pins. The tension spring is positioned around the culture vessel with its ends abutting the end pieces for alignment of the spring. After the fiber is secured, the spring is decompressed to maintain tension on the fiber while it is being rotated. This assures that the fiber remains aligned along the axis of rotation. The fiber assembly is placed in the culture vessel and culture medium is added. The culture vessel is then inserted into the rotatable portion of the clinostat and subjected to rotate at selected rpms. The internal diameter of the hollow fiber determines the distance the cells are from the axis of rotation.

Rhodes, Percy H.↗

Hybrid Tank Technology

Researchers have accomplished great advances in pressure vessel technology by applying high-performance composite materials as an over-wrap to metal-lined pressure vessels. These composite over-wrapped pressure vessels (COPVs) are used in many areas, from air tanks for firefighters and compressed natural gas tanks for automobiles, to pressurant tanks for aerospace launch vehicles and propellant tanks for satellites and deep-space exploration vehicles. NASA and commercial industry are continually striving to find new ways to make high-performance pressure vessels safer and more reliable. While COPVs are much lighter than all-metal pressure vessels, the composite material, typically graphite fibers with an epoxy matrix resin, is vulnerable to impact damage. Carbon fiber is most frequently used for the high-performance COPV applications because of its high strength-to-weight characteristics. Other fibers have been used, but with limitations. For example, fiberglass is inexpensive but much heavier than carbon. Aramid fibers are impact resistant but have less strength than carbon and their performance tends to deteriorate.

Source record↗

Polymethylmethacrylate (PMMA) Material Test Results for the Capillary Flow Experiments (CFE)

In support of the Capillary Flow Experiments (CFE) program, several polymethylmethacrylate (PMMA) flight vessels were constructed. Some vessels used a multipiece design, which was chemically welded together. Due to questions regarding the effects of the experiment fluid (silicone oil) on the weld integrity, a series of tests were conducted to provide evidence of the adequacy of the current vessel design. Tensile tests were conducted on PMMA samples that were both in the as-received condition, and also aged in air or oil for up to 8 weeks. Both welded and unwelded samples were examined. Fracture of the joints was studied using notched tensile specimens and Brazilian disk tests. Results showed that aging had no effect on tensile properties. While the welded samples were weaker than the base parent material, the weld strength was found to be further degraded by bubbles in the weld zone. Finally a fracture analysis using the worst-case fracture conditions of the vessel was performed, and the vessel design was found to have a factor of three safety margin.

Lerch, Bradley A.↗

Bayes Analysis and Reliability Implications of Stress-Rupture Testing a Kevlar/Epoxy COPV Using Temperature and Pressure Acceleration

Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.

Phoenix, S. Leigh↗

Microgravity-Enhanced Stem Cell Selection

Stem cells, both embryonic and adult, promise to revolutionize the practice of medicine in the future. In order to realize this potential, a number of hurdles must be overcome. Most importantly, the signaling mechanisms necessary to control the differentiation of stem cells into tissues of interest remain to be elucidated, and much of the present research on stem cells is focused on this goal. Nevertheless, it will also be essential to achieve large-scale expansion and, in many cases, assemble cells in 3D as transplantable tissues. To this end, microgravity analog bioreactors can play a significant role. Microgravity bioreactors were originally conceived as a tool to study the cellular responses to microgravity. However, the technology can address some of the shortcomings of conventional cell culture systems; namely, the deficiency of mass transport in static culture and high mechanical shear forces in stirred systems. Unexpectedly, the conditions created in the vessel were ideal for 3D cell culture. Recently, investigators have demonstrated the capability of the microgravity bioreactors to expand hematopoietic stem cells compared to static culture, and facilitate the differentiation of umbilical cord stem cells into 3D liver aggregates. Stem cells are capable of differentiating into functional cells. However, there are no reliable methods to induce the stem cells to form specific cells or to gain enough cells for transplantation, which limits their application in clinical therapy. The aim of this study is to select the best experimental setup to reach high proliferation levels by culturing these cells in a microgravity-based bioreactor. In typical cell culture, the cells sediment to the bottom surface of their container and propagate as a one-cell-layer sheet. Prevention of such sedimentation affords the freedom for self-assembly and the propagation of 3D tissue arrays. Suspension of cells is easily achievable using stirred technologies. Unfortunately, in conventional bioreactors, stirring invokes deleterious forces that disrupt cell aggregation and results in cell death. First-generation rotating bioreactors provided rotation on the horizontal axis, which resulted in the suspension of cells without stirring, thus providing a suitable environment to propagate cells without sedimentation to a surface. The rotating wall bioreactors did not provide a way to remove air bubbles that were causing shear and disrupting 3D cultures. Johnson Space Center successfully engineered the hydrofocusing bioreactor (HFB) that resolved the problem of removing the air bubbles from the fluid medium of NASA's rotating-wall space bioreactors. The HFB uses the principle of hydrodynamic focusing that simultaneously produces a low-shear fluid culture environment and a variable hydrofocusing force that can control the movement, location, and removal of suspended cells, tissues, and air bubbles from the bioreactor. The HFB is a rotating, domeshaped cell culture vessel with a centrally located sampling port and an internal viscous spinner. The vessel and spinner can rotate at different speeds either in the same or opposite directions. Rotation of the vessel and viscous interaction at the spinner generate a hydrofocusing force. Adjusting the differential rotation rate between vessel and spinner controls the magnitude of the force.

Claudio, Pier Paolo↗

Miniature Laboratory for Detecting Sparse Biomolecules

A miniature laboratory system has been proposed for use in the field to detect sparsely distributed biomolecules. By emphasizing concentration and sorting of specimens prior to detection, the underlying system concept would make it possible to attain high detection sensitivities without the need to develop ever more sensitive biosensors. The original purpose of the proposal is to aid the search for signs of life on a remote planet by enabling the detection of specimens as sparse as a few molecules or microbes in a large amount of soil, dust, rocks, water/ice, or other raw sample material. Some version of the system could prove useful on Earth for remote sensing of biological contamination, including agents of biological warfare. Processing in this system would begin with dissolution of the raw sample material in a sample-separation vessel. The solution in the vessel would contain floating microscopic magnetic beads coated with substances that could engage in chemical reactions with various target functional groups that are parts of target molecules. The chemical reactions would cause the targeted molecules to be captured on the surfaces of the beads. By use of a controlled magnetic field, the beads would be concentrated in a specified location in the vessel. Once the beads were thus concentrated, the rest of the solution would be discarded. This procedure would obviate the filtration steps and thereby also eliminate the filter-clogging difficulties of typical prior sample-concentration schemes. For ferrous dust/soil samples, the dissolution would be done first in a separate vessel before the solution is transferred to the microbead-containing vessel.

Lin, Ying↗

Spill-Resistant Alkali-Metal-Vapor Dispenser

A spill-resistant vessel has been developed for dispensing an alkali-metal vapor. Vapors of alkali metals (most commonly, cesium or rubidium, both of which melt at temperatures slightly above room temperature) are needed for atomic frequency standards, experiments in spectroscopy, and experiments in laser cooling. Although the present spill-resistant alkali-metal dispenser was originally intended for use in the low-gravity environment of outer space, it can also be used in normal Earth gravitation: indeed, its utility as a vapor source was confirmed by use of cesium in a ground apparatus. The vessel is made of copper. It consists of an assembly of cylinders and flanges, shown in the figure. The uppermost cylinder is a fill tube. Initially, the vessel is evacuated, the alkali metal charge is distilled into the bottom of the vessel, and then the fill tube is pinched closed to form a vacuum seal. The innermost cylinder serves as the outlet for the vapor, yet prevents spilling by protruding above the surface of the alkali metal, no matter which way or how far the vessel is tilted. In the event (unlikely in normal Earth gravitation) that any drops of molten alkali metal have been shaken loose by vibration and are floating freely, a mesh cap on top of the inner cylinder prevents the drops from drifting out with the vapor. Liquid containment of the equivalent of 1.2 grams of cesium was confirmed for all orientations with rubbing alcohol in one of the prototypes later used with cesium.

Klipstein, William↗

Analysis of Retinal Vascular Branching in Human Subjects Undergoing 70-Day Head-Down Tilt by NASAs VESGEN Software

Significant risks for visual impairment were discovered recently in astronauts following spaceflight, especially after long-duration missions. We hypothesize that microgravity-induced fluid shifts result in pathological changes within the retinal vasculature that precede visual and other ocular impairments. We therefore are analyzing retinal vessels in healthy subjects before and after head-down tilt (HDT), a ground-based microgravity analog with NASA's VESsel GENeration Analysis (VESGEN) software. Methods. Spectralis® infrared (IR) fundus images were collected from both eyes of 6 subjects before and after 70 days of bed rest at 6 degree HDT (NASA Campaign 11). For our retrospective study, branching patterns in arterial and venous trees are mapped by VESGEN into vessel branching generations (Gx) that are quantified by parameters such as densities of vessel length (Lv), area (Av), number (Nv) and fractal dimension (Df) as described previously for diabetic retinopathy (IOVS 51(1):498). Results are further assigned by VESGEN into groups of large (G1-3), medium (G4-6) and small (G≥7) vessels. Results. All subjects remained asymptomatic throughout duration of HDT. To date, we have analyzed one IR image from each of the 12 eyes. Interestingly, two groups of the masked study population identified by VESGEN are distinguished by the presence or absence of small veins (G≥7). For example, L≥7 and Av≥7 are 2.7+/-1.3 E-4 px/px2 and 7.2+/-3.6 E-4 px2/px2 in 6 retinas, but 0 in the other 6 retinas. Nonetheless, the space-filling properties of the entire venous trees were remarkably uniform by all parameters, such as Df = 1.56+/-0.02 for 6 retinas with G≥7 and 1.55+/-0.02 for retinas without G≥7. No small arteries (G≥7) were detected. Conclusions. For our preliminary masked analysis, two groups of venous trees with and without small veins (G≥7) were clearly revealed by VESGEN. Upon completing all images and unmasking the subject status of before and after HDT, we will determine whether differences in the presence or absence of small veins are important correlates, and perhaps reliable predictors, of other ocular and physiological adaptations to prolonged head-down tilt and microgravity. Clinical methods for examining adaptive microvascular remodeling in the retina to microgravity space flight are not currently established.

Fractal↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗