Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Detection of spin-resolved electronic structures from a buried ferromagnetic layer utilizing forward Mott scattering

We report ultrahigh-resolution spin-resolved hard X-ray photoemission (HAXPES) for a buried FeNi alloy film. By utilizing the forward Mott scattering in a Au layer on FeNi, our spin-resolved HAXPES method does not require a standard spin detector and allows us to use the multi-channel electron detection system for the high-efficient electron detection as used in conventional photoemission spectroscopy. A combination of the forward Mott scattering and multi-channel detection leads us to measure a clear spin polarization as well as spin-resolved majority and minority states in the Fe 2p core-level spectra without using the standard spin detector. This method enables us to measure spin-resolved core-level spectra for buried ferromagnetic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous determination of the elastic modulus and density/thickness of ultrathin films utilizing micro-/nanoresonators under applied axial force

Thin films are widely used in microelectronics, optics, filters, and various sensing devices. We propose a method to simultaneously determine the elastic modulus and density or thickness of ultrathin films deposited on various substrate materials. This methodology utilizes measurement of the resonant frequencies of the micro-/nanoresonator under intentionally applied axial tension and, consequently, the beam to string transition. Elastic modulus and density/thickness of thin film are obtained from the ratio between the resonant frequencies of the nanoresonator with and without applied axial force.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preliminary study on weapon grade uranium utilization in molten salt reactor miniFUJI

Preliminary study on weapon grade uranium utilization in 25MWth and 50MWth of miniFUJI MSR (molten salt reactor) has been carried out. In this study, a very high enriched uranium that we called weapon grade uranium has been employed in UF{sub 4} composition. The {sup 235}U enrichment is 90 - 95 %. The results show that the 25MWth miniFUJI MSR can get its criticality condition for 1.56 %, 1.76%, and 1.96% of UF{sub 4} with {sup 235}U enrichment of at least 93%, 90%, and 90%, respectively. In contrast, the 50 MWth miniFUJI reactor can be critical for 1.96% of UF{sub 4} with {sup 235}U enrichment of at smallest amount 95%. The neutron spectra are almost similar for each power output.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Co thickness dependence of structural and magnetic properties in spin quantum cross devices utilizing stray magnetic fields

We investigate the Co thickness dependence of the structural and magnetic properties of Co thin-film electrodes sandwiched between borate glasses in spin quantum cross (SQC) devices that utilize stray magnetic fields. We also calculate the Co thickness dependence of the stray field between the two edges of Co thin-film electrodes in SQC devices using micromagnetic simulation. The surface roughness of Co thin films with a thickness of less than 20 nm on borate glasses is shown to be as small as 0.18 nm, at the same scanning scale as the Co film thickness, and the squareness of the hysteresis loop is shown to be as large as 0.96–1.0. As a result of the establishment of polishing techniques for Co thin-film electrodes sandwiched between borate glasses, we successfully demonstrate the formation of smooth Co edges and the generation of stray magnetic fields from Co edges. Theoretical calculation reveals that a strong stray field beyond 6 kOe is generated when the Co thickness is greater than 10 nm at a junction gap distance of 5 nm. From these experimental and calculation results, it can be concluded that SQC devices with a Co thickness of 10–20 nm can be expected to function as spin-filter devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lorentz factor determination for local electric fields in semiconductor devices utilizing hyper-thin dielectrics

The local electric field (the field that distorts, polarizes, and weakens polar molecular bonds in dielectrics) has been investigated for hyper-thin dielectrics. Hyper-thin dielectrics are currently required for advanced semiconductor devices. In the work presented, it is shown that the common practice of using a Lorentz factor of L = 1/3, to describe the local electric field in a dielectric layer, remains valid for hyper-thin dielectrics. However, at the very edge of device structures, a rise in the macroscopic/Maxwell electric field E{sub diel} occurs and this causes a sharp rise in the effective Lorentz factor L{sub eff}. At capacitor and transistor edges, L{sub eff} is found to increase to a value 2/3 < L{sub eff} < 1. The increase in L{sub eff} results in a local electric field, at device edge, that is 50%–100% greater than in the bulk of the dielectric. This increase in local electric field serves to weaken polar bonds thus making them more susceptible to breakage by standard Boltzmann and/or current-driven processes. This has important time-dependent dielectric breakdown (TDDB) implications for all electronic devices utilizing polar materials, including GaN devices that suffer from device-edge TDDB.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Energy utilization in fluctuating biological energy converters

We have argued previously that energy utilization and evolution are emergent properties based on a small number of established laws of physics and chemistry. The relevant laws constitute a framework for biology on a level intermediate between quantum chemistry and cell biology. There are legitimate questions whether these concepts are valid at the mesoscopic level. Such systems fluctuate appreciably, so it is not clear what their efficiency is. Advances in fluctuation theorems allow the description of such systems on a molecular level. We attempt to clarify this topic and bridge the biochemical and physical descriptions of mesoscopic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tunable hard X-ray spectrometer utilizing asymmetric planes of a quartz transmission crystal

A Cauchois type hard x-ray spectrometer was developed that utilizes the (301) diffraction planes at an asymmetric angle of 23.51° to the normal to the surface of a cylindrically curved quartz transmission crystal. The energy coverage is tunable by rotating the crystal and the detector arm, and spectra were recorded in the 8 keV to 20 keV range with greater than 2000 resolving power. The high resolution results from low aberrations enabled by the nearly perpendicular angle of the diffracted rays with the back surface of the crystal. By using other asymmetric planes of the same crystal and rotating to selected angles, the spectrometer can operate with high resolution up to 50 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A rapid excitation-emission matrix fluorometer utilizing supercontinuum white light and acousto-optic tunable filters

Scanning speed and coupling efficiency of excitation light to optic fibres are two major technical challenges that limit the potential of fluorescence excitation-emission matrix (EEM) spectrometer for on-line applications and in vivo studies. In this paper, a novel EEM system, utilizing a supercontinuum white light source and acousto-optic tunable filters (AOTFs), was introduced and evaluated. The supercontinuum white light, generated by pumping a nonlinear photonic crystal fiber with an 800 nm femtosecond laser, was efficiently coupled into a bifurcated optic fiber bundle. High speed EEM spectral scanning was achieved using AOTFs both for selecting excitation wavelength and scanning emission spectra. Using calibration lamps (neon and mercury argon), wavelength deviations were determined to vary from 0.18 nm to −0.70 nm within the spectral range of 500–850 nm. Spectral bandwidth for filtered excitation light broadened by twofold compared to that measured with monochromatic light between 650 nm and 750 nm. The EEM spectra for methanol solutions of laser dyes were successfully acquired with this rapid fluorometer using an integration time of 5 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

About the parametrizations utilized to perform magnetic moments measurements using the transient field technique

The experimental study of nuclear magnetic moments, using the Transient Field technique, makes use of spin-orbit hyperfine interactions to generate strong magnetic fields, above the kilo-Tesla regime, capable to create a precession of the nuclear spin. A theoretical description of such magnetic fields is still under theoretical research, and the use of parametrizations is still a common way to address the lack of theoretical information. In this contribution, a review of the main parametrizations utilized in the measurements of Nuclear Magnetic Moments will be presented, the challenges to create a theoretical description from first principles will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A curved edge diffraction-utilized displacement sensor for spindle metrology

This paper presents a new dimensional metrological sensing principle for a curved surface based on curved edge diffraction. Spindle error measurement technology utilizes a cylindrical or spherical target artifact attached to the spindle with non-contact sensors, typically a capacitive sensor (CS) or an eddy current sensor, pointed at the artifact. However, these sensors are designed for flat surface measurement. Therefore, measuring a target with a curved surface causes error. This is due to electric fields behaving differently between a flat and curved surface than between two flat surfaces. In this study, a laser is positioned incident to the cylindrical surface of the spindle, and a photodetector collects the total field produced by the diffraction around the target surface. The proposed sensor was compared with a CS within a range of 500 μm. The discrepancy between the proposed sensor and CS was 0.017% of the full range. Its sensing performance showed a resolution of 14 nm and a drift of less than 10 nm for 7 min of operation. This sensor was also used to measure dynamic characteristics of the spindle system (natural frequency 181.8 Hz, damping ratio 0.042) and spindle runout (22.0 μm at 2000 rpm). The combined standard uncertainty was estimated as 85.9 nm under current experiment conditions. It is anticipated that this measurement technique allows for in situ health monitoring of a precision spindle system in an accurate, convenient, and low cost manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

Purpose: to study the potential utility of 1-thio-D-glucose labeled with {sup 99m}Tc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of {sup 99m}Tc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with {sup 99m}Tc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of {sup 99m}Tc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with {sup 99m}Tc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of {sup 99m}Tc-1-thio-D-glucose at the tumor site. The accumulation of {sup 99m}Tc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that {sup 99m}Tc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of {sup 99m}Tc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental results from an X-ray imaging crystal spectrometer utilizing multi-wire proportional counter for KSTAR

The inconsistency of the first experimental results from the X-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research device utilizing a multi-wire proportional counter (MWPC) is clarified after improving the photon-count rate of the data acquisition system for the MWPC and ground loop isolator for the whole spectrometer system. The improved MWPC is successfully applied to pure Ohmic plasmas as well as plasmas with high confinement modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlled modulation of hard and soft X-ray induced tunneling currents utilizing coaxial metal-insulator-metal probe tips

Here, the effect of a local external electric field on the barrier potential of a tunneling gap is studied utilizing an emerging technique, synchrotron x-ray scanning tunneling microscopy. Here, we demonstrate that the shape of the potential barrier in the tunneling gap can be altered by a localized external electric field, generated by voltages placed on the metallic outer shield of a nanofabricated coaxial metal-insulator-metal tip, resulting in a controlled linear modulation of the tunneling current. Experiments at hard and soft x-ray synchrotron beamlines reveal that both the chemical contrast and magnetic contrast signals measured by the tip can be drastically enhanced, resulting in improved local detection of chemistry and magnetization at the surface.

36 MATERIALS SCIENCE↗

Advances in utilizing event based data structures for neutron scattering experiments

This article strives to expand on existing work to demonstrate advancements in data processing made available using event mode measurements. Most spallation neutron sources in the world have data acquisition systems that provide event recording. The new science that is enabled by utilizing event mode has only begun to be explored. In the past, these studies were difficult to perform because histograms forced dealing with either large chunks of time or a large number of files. With event based data collection, data can be explored and rebinned long after the measurement has completed. This article will review some of the principles of event data and how the method opens up new possibilities for in situ measurements, highlighting techniques that can be used to explore changes in the data. We also demonstrate the statistical basis for determining data quality and address the challenge of determining how long to measure mid-measurement. Lastly, we demonstrate a model independent method of grouping data via hierarchical clustering methods that can be used to improve calibration, reduction, and data exploration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Qualification of a multi-diagnostic detonator-output characterization procedure utilizing PMMA witness blocks

In this study, experiments were conducted to qualify a multi-diagnostic characterization procedure for the performance output of a detonator when fired into a poly(methyl methacrylate) (PMMA) witness block. A suite of optical diagnostics were utilized in combination to both bound the shock wave interaction state at the detonator/PMMA interface and characterize the nature of the shock wave decay in PMMA. The diagnostics included the Shock Wave Image Framing Technique (SWIFT), a photocathode tube streak camera, and photonic Doppler velocimetry (PDV). High-precision, optically clear witness blocks permitted dynamic flow visualization of the shock wave in PMMA via focused shadowgraphy. SWIFT-and streak-imaging diagnostics captured the spatiotemporally evolving shock wave, providing a two-dimensional temporally discrete image set and a one-dimensional temporally continuous image, respectively. PDV provided the temporal velocity history of the detonator output along the detonator axis. Lastly, through combination of the results obtained, a bound was able to be placed on the interface condition and a more-physical profile representing the shock wave decay in PMMA for an exploding-bridgewire detonator was achieved.

47 OTHER INSTRUMENTATION↗

Utilization of O-X-B mode conversion of 28 GHz microwaves to heat core electrons in the upgraded Proto-MPEX

The magnetic geometry of the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) was recently altered to enable more effective utilization of 28 GHz microwave auxiliary power, specifically: (1) to heat plasma electrons in the radial core of the device and (2) to deliver the heated plasma to the target plate of the device. To achieve this goal, the microwave launcher geometry and placement were significantly re-engineered, guided by previous experimental results and computational modeling. The core electron temperature in the launcher region is observed to increase from 3 eV to 11 eV with 30 kW of auxiliary power after the improvements, and an increase from 3 eV to 6 eV is concurrently measured in the target region (~1 m from the launcher) at electron density above O-mode cutoff. Radially resolved measurements in the launcher region exhibit a strong dependence on the magnetic geometry. The conclusions of a magnetic field scan reinforce the effectiveness of the intended O-X-B mode conversion scenario that is currently planned for microwave heating of the Material Plasma Exposure eXperiment (MPEX).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

Quantum utility in simulating the real-time dynamics of the Fermi–Hubbard model using superconducting quantum computers

The Fermi–Hubbard model is a fundamental model in condensed matter physics that describes strongly correlated electrons. On the other hand, quantum computers are emerging as powerful tools for exploring the complex dynamics of these quantum many-body systems. In this work, we demonstrate the quantum simulation of the one-dimensional Fermi–Hubbard model using IBM's superconducting quantum computers, employing over 100 qubits. We introduce a first-order Trotterization scheme and extend it to an optimized second-order Trotterization for the time evolution in the Fermi–Hubbard model, specifically tailored for the limited qubit connectivity of quantum architectures, such as IBM's platforms. Notably, both Trotterization approaches are scalable and maintain a constant circuit depth at each Trotter step, regardless of the qubit count, enabling us to precisely investigate the relaxation dynamics in the Fermi–Hubbard model by measuring the expectation value of the Néel observable (staggered magnetization) for time-evolved quantum states. Lastly, our successful measurement of expectation values in such large-scale quantum many-body systems, especially at longer time scales with larger entanglement, highlights the quantum utility of superconducting quantum platforms over conventional classical approximation methods.

97 MATHEMATICS AND COMPUTING↗