Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Communications and navigation

The use of a computer simulation to quantitatively measure the distortion on a standard video test signal which experiences frequency modulation, filtering, and frequency demodulation is discussed. The process is applied to frequency modulated television systems for use with the ATS-F spacecraft. A block diagram of the system is presented. The characteristics of a millimeter wave space communication system are analyzed. The application of the Omega position location equipment (OPLE) for a global rescue net is reported. The development of a high speed photodetector for the neodynium yag laser system is discussed and the characteristics of the system are explained. The effects of gas pressure on waveguide laser tunability are examined.

Source record↗

Permanent and separable aerospace tubing/ fitting evaluation program, volume 1

The tube fitting evaluation program was conducted to develop a standard overall test program including methods, procedures, and equipment as well as recommended test sequences for qualifying fitting/tubing assemblies. The program consisted of testing the MS flareless (separable) fitting and utilizing the results as baseline data from which all other fittings will be evaluated. Five separable designs and five permanent designs were tested in three sizes with two types of tubing materials. The basic design requirements were 4,000 psi operating pressure within the temperature range of minus 65 F to plus 450 F while also being compatible with 21-6-9 and titanium 3Al-2.5V tubing alloys.

Ursell, C. R.↗

Photoelectron counting with an image intensifier tube and a self-scanned photodiode array

A self-scanned photodiode array was fiber-optically coupled to an ITT proximity-focused image intensifier tube. It was determined that a single photoelectron event produces 34,000 charge carriers in a photodiode. This charge is only a factor of 2.8 above the rms noise level of the preamplifier used in the tests, but standard charge-sensitive techniques are at least a factor of 12 better. The image tube and photodiode array combination can be packaged in a disk 5.1 cm in diameter and 2.6 cm thick.

Sandel, B. R.↗

Interagency comparison of iodometric methods for ozone determination

The California Air Resources Board appointed an Oxidant Calibration Committee for the purpose of evaluating the accuracy of the different agency calibration procedures. The committee chose UV absorption photometry as the reference method for ozone measurement. Interagency comparisons of the various iodometric methods were conducted relative to the ultraviolet standard. The tests included versions of the iodometric methods as employed by the Air Resources Board, the Los Angeles Air Pollution Control District, and the EPA. An alternative candidate reference method for ozone measurement, gas phase titration, was also included in the test series.

Demore, W. B.↗

Varying G

The problem of the variation of the gravitational constant with cosmological time is critically analyzed. Since Einstein's equation does not allow G to vary on any time scale, no observational data can be analyzed within the context of the standard theory. The recently proposed scale covariant theory, which allows (but does not demand) G to vary, and which has been shown to have passed several standard cosmological tests, is employed to discuss some recent nonnull observational results which indicate a time variation of G.

Canuto, V.↗

Tension-mode loading for bend specimens in cryogens

Special fixture permits use of tension-loading apparatus in fracture-toughness tests on standard bend specimens. Specimen is held in place by spacer blocks and wire clips. Central, load-application roller bends specimen between lateral, reaction-load rollers.

Pierce, W. S.↗

A simple apparatus for the experimental study of non-steady flow thrust-augmenter ejector configurations

A flexible, and easily modified, test rig is described which allows a one dimensional nonsteady flow stream to be generated, economically from a steady flow source of compressed air. This nonsteady flow is used as the primary stream in a nonsteady flow ejector constituting part of the test equipment. Standard piezo-electric pressure transducers etc. allow local pressures to be studied, as functions of time, in both the primary and secondary (mixed) flow portions of the apparatus. Provision is also made for measuring the primary and secondary mass flows and the thrust generated. Sample results obtained with the equipment are presented.

Khare, J. M.↗

The Analysis of Turbulent Flow by Hot Wire Signals

When measuring velocities in turbulent gas flow, approximation signal analysis with hot wire anemometers having one and two wire probes are used. A numeric test of standard analyses shows the resulting systemmatic error increases quickly with increasing turbulent intensity. Since it also depends on the turbulence structure, it cannot be corrected. The use of such probes is thus restricted to low turbulence. By means of three wire probes (in two dimensional flows with X wire probes) in principle, instantaneous values of velocity can be determined, and an asymmetric arrangement of wires has a theoretical advantage.

Bartenwerfer, M.↗

Effect of some nitrogen compounds thermal stability of jet A

The effect of known concentrations of some nitrogen containing compounds on the thermal stability of a conventional fuel, namely, Jet A was investigated. The concentration range from 0.01 to 0.1 wt% nitrogen was examined. Solutions were made containing, individually, pyrrole, indole, quinoline, pyridine, and 4 ethylpyridine at 0.01, 0.03, 0.06, and 0.1 wt% nitrogen concentrations in Jet A. The measurements were all made by using a standard ASTM test for evaluating fuel thermal oxidation behavior, namely, ASTM D3241, 'thermal oxidation stability of turbine fuels (JFTOT procedure).' Measurements were made at two temperature settings, and 'breakpoint temperatures' were determined. The results show that the pyrrole and indole solutions have breakpoint temperatures substantially lower than those of the Jet A used.

Antoine, A. C.↗

Implicit unsteady transonic airfoil calculations at supersonic freestreams

The computer code LTRAN2 has been extended to compute unsteady transonic flows about oscillating airfoils with supersonic freestreams. The LTRAN2 code uses an alternating direction implicit (ADI) algorithm to solve the two-dimensional, nonlinear, low-frequency, transonic small-disturbance (LF-TSD) equation. The modified code, LTRAN2-SS, includes a 'high-frequency' option. Steady solutions are checked against those computed by the steady TSD code, TSFOIL; unsteady computations of the linear LF-TSD equation are compared with known linear theory solutions; and new unsteady nonlinear solutions are presented. These cases include standard AGARD test cases for the NLR 7301, MBB-A3, and DO Al supercritical airfoils, as well as several NACA airfoils. The modified code enables aerodynamicists to quickly and efficiently compute transonic flows for both subsonic and supersonic freestreams, and thus resolve flutter boundaries through the full extent of the transonic dip phenomenon.

Chow, L. J.↗

Antimotion-sickness efficacy of scopolamine 12 and 72 hours after transdermal administration

The antimotion sickness remedy, transdermal therapeutic system-scopolamine, administered in this experiment was scheduled to deliver 1.0 mg of scopolamine over a period of 3 d, and this paper compares its efficacy 12 and 72 h after administration. In a double-blind study, six male college students were individually exposed to a standardized provocative test in a slow rotation room after six apparently identical treatments comprising four placebos and two medications. Efficacy was categorized as beneficial, inconsequential, or detrimental. None of the responses was detrimental. Following the first administration of the therapeutic system, there were four beneficial responses after 12 h but none was beneficial after 72 h. Following the second treatment regimen, there were four beneficial responses after 12 h and three beneficial responses after 72 h. Great individual differences were demonstrated, two subjects accounting for six beneficial responses and two accounting for only one beneficial response. The difference in efficacy after 12 and 72 h has practical and theoretical significance.

Graybiel, A.↗

Solar rotation measurements at Mount Wilson. III - Meridional flow and limbshift

It is shown that the use of a two-parameter limbshift and a meridional flow velocity fits solar velocity data better than the standard analysis defined by Howard et al. (1980). The data used are the coarse residual velocity arrays, with 34 equal intervals in both sine latitude and sine longitude. There are a total of 2899 full-disk observations between January 1, 1967, and December 12, 1980. The original velocity fields are reconstructed by adding into the residual arrays the large-scale patterns that were measured and removed on a daily basis by a standard reduction. Tests of this reconstituded data set show that no significant errors are introduced in the analysis of large-scale velocity fields. The results of the analysis presented here imply that the study of solar velocity pattern at the level of a few m/s requires that magnetic regions be treated separately from nonmagnetic regions.

Labonte, B. J.↗

Development of a qualification standard for adhesives used in hybrid microcircuits

Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.

Licari, J. J.↗

18-percent efficient terrestrial silicon solar cells

Silicon solar cells are described which operate at energy conversion efficiencies in excess of 18 percent under standard terrestrial test conditions (AM1.5, 100 mW/sq cm, 28 C). These are believed to be the most efficient silicon cells reported to date. The high efficiency is a result of the combination of high open-circuit voltage due to the careful attention paid to passivation of the top surface of the cell; high fill factors due to the high open-circuit voltage and low parasitic resistance losses; and high short-circuit current due to the use of shallow diffusions, a low grid coverage, and an optimized double-layer antireflection coating.

Blakers, A. W.↗

Towards a 20 percent efficient silicon solar cell

A project is underway at the University of New South Wales aimed at producing a 20 percent efficient silicon solar cell. A prerequisite for obtaining such a significant increase in cell efficiency is the improvement of the open circuit voltage of these cells. Two techniques are described which have produced experimental devices with open circuit voltages of 690 mV or higher. These high voltage techniques have been combined with other high efficiency design features to produce silicon cells with independently measured energy conversion efficiencies in excess of 19 percent under standard terrestrial test conditions (direct beam AM1.5 spectrum, 100 mW/sq cm, 28 C).

Green, M. A.↗

High-efficiency silicon solar cells

Silicon solar cells are described which operate at energy conversion efficiencies independently measured at 18.7 percent under standard terrestrial test conditions (AM1.5, 100 mW/sq cm, 28 C). These are apparently the most efficient silicon cells fabricated to date. The high-efficiency results from a combination of high open-circuit voltage due to the careful attention paid to the passivation of the top surface of the cell, high fill factor due to the high open-circuit voltage and low parasitic resistance losses, and high short-circuit current density due to the use of shallow diffusions, a low grid coverage, and an optimized double layer antireflection coating.

Green, M. A.↗

Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, K.↗