Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “space electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Imaging Electrons in Two Dimensional Materials (Final report)

Two-dimensional (2D) materials have extraordinary characteristics that offer promising new approaches for science and technology. Electrons in graphene can move ballistically through a sheet, even though it is only a single atom thick. And transition metal dichalcogenide materials can be cleaved into 2D flakes of all types – metals, semiconductors, insulators, magnetic materials, and superconductors. To benefit from these discoveries, the science needs to be understood to transform 2D materials into useful new devices and systems. The evolution in time of atomic scale graphene structures has been studied in time with a transmission electron microscope (TEM), and ballistic transport of electrons in graphene was been imaged using a cooled scanning probe microscope (SPM), as well as electron motion in MoS 2 . Graphene is only one atom thick but is extremely strong, creating the opportunity to fabricate atomic scale structures in the lateral direction. Using an atomic resolution TEM, a suspended sheet of graphene can be shaped by a Si impurity atom on its surface that acts like a chisel to open up apertures, one atom at a time. The electrons in the TEM provide both the chiseling energy and the ability to image the results. Electrons and holes in graphene form a new type of electronic system with conical conduction and valence bands that meet at the Dirac point, with no energy gap. For moderate densities, the carriers form a Fermi liquid with ballistic transport over micron-scale distances. Using a cooled SPM the cyclotron orbit of electrons in graphene has been imaged. In the magnetic focusing regime, electrons leaving a point contact circle around and leave from a second point contact when the cyclotron diameter is equal to the contact spacing. The paths of electrons are focused - they enter at different angles but converge again at the exiting contact. When the SPM tip knocks an electron out of its orbit, an imaging signal is created. The ballistic motion of carriers in graphene opens the way for ballistic devices that manipulate beams of electrons and holes. Our collaborator Gil-Ho Lee, in Philip Kim's group, created a collimating contact by placing zig-zag absorbers on either side of entering electrons. Our cooled SPM was used to image the electron beam and determine its 9-degree halfwidth. By changing the gate voltage, a collimated beam of holes was also created, opening the way for colliding beam experiments. Coherent beams of carriers are desirable for quantum information processing. Via Andreev reflection, superconducting contacts can covert Cooper pairs in a superconductor to an ingoing and outgoing electrons and holes. Using our cooled SPM, Andreev reflection was imaged from a superconducting contact on a graphene device. Magnetic focusing was used to create an incoming beam of electrons and an outgoing beam of holes, detected by a third point contact. The images show a clear transition from normal reflection above the superconducting transition temperature to Andreev reflection as the device is cooled. Transition metal dichalcogenides offer a wide array of materials that can be exfoliated into ultrathin 2D sheets. A cooled SPM can be used to detect quantum dots as well as to image electron flow. The tip charge capacitively couples to electrons on the dot, acting as a gate to tune the dot conductance. Coulomb blockade peaks appear as a bullseye pattern in an SPM image as the tip is raster scanned above the dot. This approach was used to detect quantum dots in a MoS 2 channel as the carrier density was reduced and electrons pooled in low energy points. Through our DOE supported research, cooled SPM imaging has proven to be a very useful tool to uncover the motion of electrons and holes in the new quantum materials graphene and MoS 2 .

36 MATERIALS SCIENCE↗

Additive Manufacturing Circuitry on Rigid and Flexible Substrates for Space Applications

Additive manufacturing techniques for electronics, including Aerosol Jet Printing (AJP), Syringe Printing, and Ink Jet Printing, will enable new detector assemblies that were not previously possible with traditional assembly processes. This technology has the potential to reduce mass and volume for fabrication and assembly of detector, instrument and electronics concepts by reducing trace widths down to 10 microns, printing on complex geometries, and allowing new concept production. This presentation summarizes efforts developing printing techniques to manufacture detectors and circuitry for space applications.

Detectors↗

Acceleration of nonmonoenergetic electron bunches injected into a wake wave

The trapping and acceleration of nonmonoenergetic electron bunches in a wake field wave excited by a laser pulse in a plasma channel is studied. Electrons are injected into the region of the wake wave potential maximum at a velocity lower than the phase velocity of the wave. The paper analyzes the grouping of bunch electrons in the energy space emerging in the course of acceleration under certain conditions of their injection into the wake wave and minimizing the energy spread for such electrons. The factors determining the minimal energy spread between bunch electrons are analyzed. The possibility of monoenergetic acceleration of electron bunches generated by modern injectors in a wake wave is analyzed.

43 PARTICLE ACCELERATORS↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable, and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable, and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam, and the beam plasma discharge is ignited.

Leung, Philip↗

A laboratory investigation of potential double layers

In a triple plasma device, the injection of electron current from the source chamber to the target chamber causes the formation of a potential double layer. At a low current density, the space charge of the injected current produces a virtual cathode-type potential double layer. This double layer is stable and various wave instabilities are observed to associate with this double layer. As the current density is increased, the double layer becomes unstable and a moving double layer results. As the current density is increased further, the enhanced ionization causes the neutralization of the space charge of the electron beam and the 'beam plasma discharge' is ignited.

Leung, Philip↗

Earth benefits from space life sciences

Contributions of space exploration which are widely recognized are those dealing with the impact of space technology on public health and medical services in both urban and remote rural areas. Telecommunications, image enhancement, 3-dimensional image reconstructions, miniaturization, automation, and data analysis, have transformed the delivery of medical care and have brought about a new impetus to the field of biomedicine. Many areas of medical care and biological research have been affected. These include technological breakthroughs in such areas as: (1) diagnosis, treatment, and prevention of cardiovascular diseases, (2) new approaches to the understanding of osteoporosis, (3) early detection of genetic birth defects, (4) emergency medical care, and (5) treatment of chronic metabolic disorders. These are but a few examples where technology originally developed to support space medicine or space research has been applied to solving medical and health care delivery problems on Earth.

NASA Center HQS↗

Coiling free electron matter waves

Here we demonstrate particle beams that spiral in free space devoid of external fields. The beams consist of electrons in two lobes that twist around each other along the optical axis, such that each electron can be described by a two-lobed probability distribution that rotates as it propagates. Furthermore, we demonstrate that this twisting distribution can undergo programmed periods of angular acceleration. These unusual states are produced by preparing each free electron wavefunction in a superposition of non-diffracting Bessel modes that carry orbital angular momentum using nanofabricated diffraction holograms. The holograms can encode nonlinear azimuthal phase so that the resulting electron probability distribution twists in space in a controllable manner, accelerating and decelerating during propagation, without any radiation. This work provides a new platform to explore the dynamics of electrons in magnetic fields, and opens the possibility of producing other types of particle beams with coiling geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Component-Level Electronic-Assembly Repair (CLEAR) Analysis of the Problem Reporting and Corrective Action (PRACA) Database of the International Space Station On-Orbit Electrical Systems

The NASA Constellation Program is investigating and developing technologies to support human exploration of the Moon and Mars. The Component-Level Electronic-Assembly Repair (CLEAR) task is part of the Supportability Project managed by the Exploration Technology Development Program. CLEAR is aimed at enabling a flight crew to diagnose and repair electronic circuits in space yet minimize logistics spares, equipment, and crew time and training. For insight into actual space repair needs, in early 2008 the project examined the operational experience of the International Space Station (ISS) program. CLEAR examined the ISS on-orbit Problem Reporting and Corrective Action database for electrical and electronic system problems. The ISS has higher than predicted reliability yet, as expected, it has persistent problems. A goal was to identify which on-orbit electrical problems could be resolved by a component-level replacement. A further goal was to identify problems that could benefit from the additional diagnostic and test capability that a component-level repair capability could provide. The study indicated that many problems stem from a small set of root causes that also represent distinct component problems. The study also determined that there are certain recurring problems where the current telemetry instrumentation and built-in tests are unable to completely resolve the problem. As a result, the root cause is listed as unknown. Overall, roughly 42 percent of on-orbit electrical problems on ISS could be addressed with a component-level repair. Furthermore, 63 percent of on-orbit electrical problems on ISS could benefit from additional external diagnostic and test capability. These results indicate that in situ component-level repair in combination with diagnostic and test capability can be expected to increase system availability and reduce logistics. The CLEAR approach can increase the flight crew s ability to act decisively to resolve problems while reducing dependency on Earth-supplied logistics for future Constellation Program missions.

Oeftering, Richard C.↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Experimental 4D Tracking of a Single Electron in IOTA

We present the results of the first experiments on 4-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. During the next few months, full 6D tracking will be implemented. This technology makes it possible to characterize the motion of a single particle, i.e. simultaneously tracking of amplitudes and phases for slow synchrotron oscillations and fast betatron oscillations. Complete tracking of a single particle enables the first direct measurements of dynamical properties, including invariants, amplitude-dependent tunes, and chaotic behavior.

43 PARTICLE ACCELERATORS↗

Single-Electron Tracking (SETI)

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, tunes dependence on amplitudes with exceptional precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Synthesis and Structure Determination of Ferromagnetic Semiconductors LaAMnSnO6 (A = Sr Ba)

LaAMnSnO{sub 6} (A = Sr, Ba) have been synthesized by high temperature solid-state reactions under dynamic 1% H{sub 2}/Ar flow. Rietveld refinements on room temperature powder X-ray diffraction data indicate that LaSrMnSnO{sub 6} crystallizes in the GdFeO{sub 3}-structure, with space group Pnma and, combined with transmission electron microscopy, LaBaMnSnO{sub 6} in Imma. Both space groups are common in disordered double-perovskites. The Mn{sup 3+} and Sn{sup 4+} ions whose valence states were confirmed by X-ray absorption spectroscopy, are completely disordered over the B-sites and the BO{sub 6} octahedra are slightly distorted. LaAMnSnO{sub 6} are ferromagnetic semiconductors with a T{sub C} = 83 K for the Sr- and 66 K for the Ba-compound. The title compounds, together with the previously reported LaCaMnSnO{sub 6} provide an interesting example of progression from Pnma to Imma as the tolerance factor increases. An analysis of the relationship between space group and tolerance factor for the series LaAMnMO{sub 6} (A = Ca, Sr, Ba; M = Sn, Ru) provides a better understanding of the symmetry determination for double perovskites.

36 MATERIALS SCIENCE↗

Component Repair Experiment-1: An Experiment Evaluating Electronic Component-Level Repair During Spaceflight

The Component Repair Experiment-1 (CRE-1) examines the capability for astronauts to perform electronics repair tasks in space. The goal is to determine the current capabilities and limits for the crew, and to make recommendations to improve and expand the range of work that astronauts may perform. CRE-1 provided two-layer, functional circuit boards and replacement components, a small tool kit, written and video training materials, and 1 hr of hands on training for the crew slated to perform the experiment approximately 7 months prior to the mission. Astronauts Michael Fincke and Sandra Magnus performed the work aboard the International Space Station (ISS) in February and March 2009. The astronauts were able to remove and replace components successfully, demonstrating the feasibility of performing component-level electronics repairs within a spacecraft. Several unsuccessful tasks demonstrated areas in need of improvement. These include improved and longer training prior to a mission, an improved soldering iron with a higher operating temperature and steady power source, video training and practice boards for refresher work or practice before a repair, and improved and varied hand tools and containment system.

Easton, John W.↗

A Sparse-Grid Probabilistic Scheme for Approximation of the Runaway Probability of Electrons in Fusion Tokamak Simulation

Runaway electrons (RE) generated during magnetic disruptions present a major threat to the safe operation of plasma nuclear fusion reactors. A critical aspect of understanding RE dynamics is to calculate the runaway probability, i.e., the probability that an electron in the phase space will runaway on, or before, a prescribed time. Such probability can be obtained by solving the adjoint equation of the underlying Fokker-Planck equation that controls the electron dynamics. In this effort, we present a sparse-grid probabilistic scheme for computing the runaway probability. The key ingredient of our approach is to represent the solution of the adjoint equation as a conditional expectation, such that discretizing the differential operator reduces to the approximation of a set of integrals. Adaptive sparse grid interpolation is utilized to approximate the map from the phase space to the runaway probability. The main novelties of this effort are the integration of the sparse-grid method into the probabilistic numerical scheme for computing escape probability, and the application of the proposed method in computing RE probabilities. Two numerical examples are given to illustrate that the proposed method can achieve O(Δt) convergence, and that the local anisotropic adaptive refinement strategy (M. Stoyanov, Adaptive sparse grid construction in a context of local anisotropy and multiple hierarchical parents. In: Sparse Grids and Applications-Miami 2016, Springer, Berlin, 2018, pp. 175–199) can effectively handle the sharp transition layer between the runaway and non-runaway regions.

Yang, Minglei↗

Negative space charge effects in photon-enhanced thermionic emission solar converters

In thermionic energy converters, electrons in the gap between electrodes form a negative space charge and inhibit the emission of additional electrons, causing a significant reduction in conversion efficiency. However, in Photon Enhanced Thermionic Emission (PETE) solar energy converters, electrons that are reflected by the electric field in the gap return to the cathode with energy above the conduction band minimum. These electrons first occupy the conduction band from which they can be reemitted. This form of electron recycling makes PETE converters less susceptible to negative space charge loss. While the negative space charge effect was studied extensively in thermionic converters, modeling its effect in PETE converters does not account for important issues such as this form of electron recycling, nor the cathode thermal energy balance. Here, we investigate the space charge effect in PETE solar converters accounting for electron recycling, with full coupling of the cathode and gap models, and addressing conservation of both electric and thermal energy. The analysis shows that the negative space charge loss is lower than previously reported, allowing somewhat larger gaps compared to previous predictions. For a converter with a specific gap, there is an optimal solar flux concentration. The optimal solar flux concentration, the cathode temperature, and the efficiency all increase with smaller gaps. For example, for a gap of 3 μm the maximum efficiency is 38% and the optimal flux concentration is 628, while for a gap of 5 μm the maximum efficiency is 31% and optimal flux concentration is 163.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗