Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Fiber Optic Control System integration for advanced aircraft. Electro-optic and sensor fabrication, integration, and environmental testing for flight control systems

This report describes the design, development, and testing of passive fiber optic sensors and a multiplexing electro-optic architecture (EOA) for installation and flight test on a NASA-owned F-18 aircraft. This hardware was developed under the Fiber Optic Control Systems for Advanced Aircraft program, part of a multiyear NASA initiative to design, develop, and demonstrate through flight test 'fly-by-light' systems for application to advanced aircraft flight and propulsion control. This development included the design and production of 10 passive optical sensors and associated multiplexed EOA hardware based on wavelength division multiplexed (WDM) technology. A variety of sensor types (rotary position, linear position, temperature, and pressure) incorporating a broad range of sensor technologies (WDM analog, WDM digital, analog microbend, and fluorescent time rate of decay) were obtained from different manufacturers and functionally integrated with an independently designed EOA. The sensors were built for installation in a variety of aircraft locations, placing the sensors in a variety of harsh environments. The sensors and EOA were designed and built to have the resulting devices be as close as practical to a production system. The integrated system was delivered to NASA for flight testing on a NASA-owned F-18 aircraft. Development and integration testing of the system provided valuable information as to which sensor types were simplest to design and build for a military aircraft environment and which types were simplest to operate with a multiplexed EOA. Not all sensor types met the full range of performance and environmental requirements. EOA development problems provided information on directions to pursue in future fly-by-light flight control development programs. Lessons learned in the development of the EOA and sensor hardware are summarized.

Seal, Daniel W.↗

An X-Ray and Infrared Study of Grains in the Puppis a Supernova Remnant

The second achievement meets the second objective for the second year. We choose adjustable prism couplers for connecting the sensor to optical fiber lines in our design of a breadboard prototype of the sensor. These couplers have good coupling efficiency at relatively low cost comparing to any other alternatives such as grating couplers. The third accomplishment meets the third objective for the second year. We performed testing the breadboard prototype of the sensor using heating as a technique of changing its refractive index. The only difference is that we ruled out the channel waveguides as irrelevant to the final goals of the project. The feasibility of the sensor can be shown for the slab waveguide configuration without usage of relatively expensive technologies of channel waveguide delineation.

Vancura, O.↗

Optical Sensors based on single arm thin film Waveguide Interferometer

The second achievement meets the second objective for the second year. We choose adjustable prism couplers for connecting the sensor to optical fiber lines in our design of a breadboard prototype of the sensor. These couplers have good coupling efficiency at relatively low cost comparing to any other alternatives such as grating couplers. The third accomplishment meets the third objective for the second year. We performed testing the breadboard prototype of the sensor using heating as a technique of changing its refractive index. The only difference is that we ruled out the channel waveguides as irrelevant to the final goals of the project. The feasibility of the sensor can be shown for the slab waveguide configuration without usage of relatively expensive technologies of channel waveguide delineation.

Sarkisov, Sergey S.↗

Influence of the Anionic Zinc-Adeninate Metal–Organic Framework Structure on the Luminescent Detection of Rare Earth Ions in Aqueous Streams

Rare earth elements (REEs) are critical to numerous technologies; however, a combination of increasing demand, environmental concerns, and monopolistic marketplace conditions has spurred interest in boosting the domestic REE production from sources such as coal utilization byproducts. The economic viability of this approach requires rapid, inexpensive, and sensitive analytical techniques capable of characterizing the REE content during resource exploration and downstream REE processing (e.g., analyzing REE separation, concentration, and purification production steps). Luminescence-based sensors are attractive because many REEs may be sensitized to produce element-specific emission. Hence, a single material may simultaneously detect and distinguish multiple REEs. Metal–organic frameworks (MOFs) can sensitize multiple REEs, but their viability has been hindered by sensitivity and selectivity challenges. Understanding how the MOF structure impacts the REE sensing efficacy is critical to the rational design of new sensors. Here, we evaluate the sensing performance of seven different anionic zinc-adeninate MOFs with different organic linkers and/or structures for the visible-emitting REEs Tb, Dy, Sm, and Eu. The choice of a linker determines which REEs are sensitized and significantly influences their sensitivity and selectivity against competing species (here, Fe(II) and HCl). For a given linker, structural changes to the MOF can further fine-tune the performance. The MOFs produce some of the lowest detection limits (sub-10 ppb for Tb) reported for the aqueous sensitization-based REE detection. Importantly, the most selective MOFs demonstrated the ability to sensitize the REE signal at sub-ppm levels in a REE-spiked acid mine drainage matrix, highlighting their potential for use in real-world sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrical, structural and thermomechanical properties of doped-LaCrO3 ceramics for high temperature electronics and sensing applications.

Many important electrical and sensor applications require stable conductors under working temperatures up to 1500oC various redox environments. Common high temperature conductors such as nitrides and carbides are not stable under oxidizing atmospheres, for this reason low redox behavior materials would be more attractive. In this work, further dopant studies of the LaCrO3 system were completed in order to control the electronic and ionic conductivity, as well as the relative chemical and microstructural stability. Neodymium and Niobium dopants were initially studied to control the p-type, and potentially n-type conductive mechanisms, respectively, but other dopants strategies were also investigated. The electrical conductivity and Seebeck coefficient were characterized up to 1500oC under varying oxygen partial pressures. The phase and microstructural evolution of each material was also investigated for these compositions by XRD and SEM. The materials showing the best electrical and thermomechanical performance were included within thick films sensors and were tested.

20 FOSSIL-FUELED POWER PLANTS↗

Analytical design of multispectral sensors

An optimal design based on the criterion of minimum mean square representation error using the Karhunen-Loeve expansion was developed to represent the spectral response functions from a stratum based upon a stochastic process scene model. From the overall pattern recognition system perspective, the effect of the representation accuracy on a typical performance criterion (the probability of correct classification) is investigated. The optimum sensor design provides a standard against which practical (suboptimum) operational sensors can be compared. An example design is provided and its performance is illustrated. Although developed primarily for the purpose of sensor design, the procedure has potential for making important contributions to scene understanding. Spectral channels which have narrow bandwidths relative to current sensor systems may be necessary to provide adequate spectral representation and improved classification performance.

Wiersma, D. J.↗

Ultra-fast and sensitive magneto-optical hydrogen sensors using a magnetic nano-cap array

Magnetism in curved nano-geometries has opened a new path to design novel characteristics and phenomena that could greatly impact the future fundamental and applied studies of materials. Here, in this report, a hexagonally-packed array of magnetic nano-caps (or nano-patches, NP) exhibiting unique magnetic anisotropy and optimal nanostructure for fast hydrogen kinetics is explored as a sensing element for the spark-free magnetic-circular-dichroism (MCD) H 2 sensor. The MCD H 2 sensor outperforms the state-of-the-art optical sensors reported to date and satisfies the most challenging performance targets imposed by US Department of Energy. In particular, a Pd 67 Co 33 NP sensor exhibits response time of t 90 < 0.9 s, recovery time of t 10 < 9.0 s over the 1-100 mbar H 2 partial pressure range, and limit of detection (LOD) of ~1 ppm. The LOD improves to <700 ppb, when the signal-to-noise ratio is enhanced by stacking three NP arrays. Using a 30-nm TAF (Teflon AF 2400) polymer coating, the sorption kinetics of the Pd 67 Co 33 /TAF sensor are significantly accelerated, with t 90 < 0.4 s and t 10 < 2.8 s over the same pressure range. When the Pd 67 Co 33 /TAF sensor is further coated with a 100-nm poly(methyl methacrylate) (PMMA) layer, a rapid sorption time of t 90 < 0.5 s, LOD < 1 ppm and excellent sensor accuracy (<2.5% full scale) are maintained, while the sensor obtains strong selectivity against interference gases and moisture and a negligible aging effect. The MCD nano-cap sensor platform may have a great impact on the future deployment of H 2 fuel, H 2 environmental monitoring sensors, and fast proton-based magneto-ionic devices.

Fast and sensitive hydrogen sensors↗

Sensor Selection and Optimization for Health Assessment of Aerospace Systems

Aerospace systems are developed similarly to other large-scale systems through a series of reviews, where designs are modified as system requirements are refined. For space-based systems few are built and placed into service. These research vehicles have limited historical experience to draw from and formidable reliability and safety requirements, due to the remote and severe environment of space. Aeronautical systems have similar reliability and safety requirements, and while these systems may have historical information to access, commercial and military systems require longevity under a range of operational conditions and applied loads. Historically, the design of aerospace systems, particularly the selection of sensors, is based on the requirements for control and performance rather than on health assessment needs. Furthermore, the safety and reliability requirements are met through sensor suite augmentation in an ad hoc, heuristic manner, rather than any systematic approach. A review of the current sensor selection practice within and outside of the aerospace community was conducted and a sensor selection architecture is proposed that will provide a justifiable, dependable sensor suite to address system health assessment requirements.

Maul, William A.↗

Sensor Selection and Optimization for Health Assessment of Aerospace Systems

Aerospace systems are developed similarly to other large-scale systems through a series of reviews, where designs are modified as system requirements are refined. For space-based systems few are built and placed into service these research vehicles have limited historical experience to draw from and formidable reliability and safety requirements, due to the remote and severe environment of space. Aeronautical systems have similar reliability and safety requirements, and while these systems may have historical information to access, commercial and military systems require longevity under a range of operational conditions and applied loads. Historically, the design of aerospace systems, particularly the selection of sensors, is based on the requirements for control and performance rather than on health assessment needs. Furthermore, the safety and reliability requirements are met through sensor suite augmentation in an ad hoc, heuristic manner, rather than any systematic approach. A review of the current sensor selection practice within and outside of the aerospace community was conducted and a sensor selection architecture is proposed that will provide a justifiable, defendable sensor suite to address system health assessment requirements.

Maul, William A.↗

Mitigating humidity interference in chemiresistive hydrogen sensors through hydrophobic surface functionalization

Chemiresistive gas sensors based on semiconductor metal oxides, such as tin dioxide (SnO₂), are indispensable for detecting and monitoring toxic gases and pollutants, making them critical components in industrial and environmental applications. To enhance their performance, the metal oxides are loaded with noble metals such as palladium (Pd). However, ambient humidity poses a significant challenge to their performance. The presence of adsorbed water molecules on the oxide surface can considerably impair sensor sensitivity and overall performance. To address this issue, in this paper, we report on the application of an ultrathin, hydrophobic layer of hexamethyldisilazane to the surface of a Pd/SnO 2 sensor. This study investigates the influence of hydrophobic surface modifications on the metal oxide interface, focusing on their impact on sensor sensitivity and selectivity. The resulting sensor exhibits superior hydrogen sensing capabilities, operating effectively at low temperatures even in high humidity environments. Furthermore, the hydrophobic modification reduces the sensor’s susceptibility to interfering gases, thus enhancing its selectivity. The combined enhancements in moisture resistance and selectivity achieved through HMDS surface modification, along with the superior sensitivity of Pd/SnO₂ sensors, facilitate the development of gas sensors with enhanced humidity tolerance and broader applications.

Chemiresistive gas sensors↗

On-Orbit Calibration of ADEOS OCTS with an AVIRIS Underflight

The Ocean Color Temperature Scanner (OCTS) onboard the Advanced Earth Observation Satellite (ADEOS) was launched on August 17, 1996. Calibration of OCTS is required for use of the on-orbit measured data for retrieval of physical properties of the ocean. In the solar reflected portion of the electromagnetic spectrum, OCTS measures images with nominally 700-m spatial resolution through eight multispectral bands. The objective of this research was to establish the absolute radiometric calibration of OCTS on orbit through an underflight by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS is a NASA Earth-observing imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory (JPL). AVIRIS acquires data from 20-km altitude on a NASA ER-2 aircraft, above most of the Earth's atmosphere. AVIRIS measures the solar reflected spectrum from 370 nm to 2500 nm through 224 contiguous spectral channels. The full width at half maximum (FWHM) of the spectral channels is nominally 10-nm. AVIRIS spectra are acquired as images of 11 km by up to 800 km extent with 20-m spatial resolution. The high spectral resolution of AVIRIS data allows direct convolution to the spectral response functions of the eight multispectral bands of OCTS. The high spatial resolution of AVIRIS data allows for spatial re-sampling of the data to match the ADEOS sensors spatial resolution. In addition, the AVIRIS high spatial resolution allows assessment of the scaling effects due to environmental factors of thin cirrus clouds, sub-pixel cloud cover, white caps, ocean foam, sun-glint, and bright-target adjacency. The platform navigation information recorded by AVIRIS allows calculation of the position and observation geometry of each spectrum for matching to the OCTS measurement. AVIRIS is rigorously characterized and calibrated in the laboratory prior to and following the flight season. The stability and repeatability of AVIRIS calibration have been validated through an extensive series of inflight calibration experiments. In the OCTS portion of the spectrum, using pre- and post-flight runway calibrations of AVIRIS coupled with the on-board calibrator an absolute calibration accuracy of better than 3% spectral, 2% radiometric, and 5% spatial, has been achieved. An analogous satellite underflight calibration experiment was performed with AVIRIS and the Optical Sensor (OPS) onboard the Japanese Earth Resources Satellite (JERS).

Green, Robert O.↗

On-Orbit Calibration of ADEOS OCTS with an AVIRIS Underflight

The Ocean Color Temperature Scanner (OCTS) onboard the Advanced Earth Observation Satellite (ADEOS) was launched on August 17, 1996. Calibration of OCTS is required for use of the on-orbit measured data for retrieval of physical properties of the ocean. In the solar reflected portion of the electromagnetic spectrum, OCTS measures images with nominally 700-m spatial resolution through eight multispectral bands. The objective of this research was to establish the absolute radiometric calibration of OCTS on orbit through an underflight by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). AVIRIS is a NASA earth-observing imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory (JPL). AVIRIS acquires data from 20-km altitude on a NASA ER-2 aircraft, above most of the Earth's atmosphere. AVIRIS measures the solar reflected spectrum from 370 nm to 2500 nm through 224 contiguous spectral channels. The full width at half maximum (FWHM) of the spectral channels is nominally 10-nm. AVIRIS spectra are acquired as images of 11 km by up to 800 km extent with 20-m spatial resolution. The high spectral resolution of AVIRIS data allows direct convolution to the spectral response functions of the eight multispectral bands of OCTS. The high spatial resolution of AVIRIS data allows for spatial re-sampling of the data to match the ADEOS sensors spatial resolution. In addition, the AVIRIS high spatial resolution allows assessment of the scaling effects due to environmental factors of thin cirrus clouds, sub-pixel cloud cover, white caps, ocean foam, sun-glint, and bright-target adjacency. The platform navigation information recorded by AVIRIS allows calculation of the position and observation geometry of each spectrum for matching to the OCTS measurement. AVIRIS is rigorously characterized and calibrated in the laboratory prior to and following the flight season. The stability and repeatability of AVIRIS calibration have been validated through an extensive series of inflight calibration experiments. In the OCTS portion of the spectrum, using pre-and post-flight runway calibrations of AVIRIS coupled with the on-board calibrator an absolute calibration accuracy of better than 3% spectral, 2% radiometric and 5% spatial has been achieved. An analogous satellite underflight calibration experiment was performed with AVIRIS and the Optical Sensor (OPS) onboard the Japanese Earth Resources Satellite (JERS).

Green, Robert O.↗

Common-Path Interferometric Wavefront Sensing for Space Telescopes

This paper presents an optical configuration for a common-path phase-shifting interferometric wavefront sensor.1 2 This sensor has a host of attractive features which make it well suited for space-based adaptive optics. First, it is strictly reflective and therefore operates broadband, second it is common mode and therefore does not suffer from systematic errors (like vibration) that are typical in other interferometers, third it is a phase-shifting interferometer and therefore benefits from both the sensitivity of interferometric sensors as well as the noise rejection afforded by synchronous detection. Unlike the Shack-Hartman wavefront sensor, it has nearly uniform sensitivity to all pupil modes. Optical configuration, theory and simulations for such a system will be discussed along with predicted performance.

wavefront sensors↗

800 °C Demonstrated kHz SiC IC Electronics and Pressure Sensors as Technical Foundation for Realizing MHz DARPA HOTS Goals

The HOTS program will develop a technology for high-bandwidth, high-dynamic-range sensing at high temperature. Performance will be validated through the development and demonstration of a pressure sensor module (i.e., integrated transducer and signal-conditioning microelectronics) achieving the following performance goals: NASA Glenn has unique technology experience in extreme environment pressure sensors & IC electronics, including at 800 °C in air, providing significant risk reduction in meeting DARPA HOTS goals. Appropriate partnership and tech transfer should accelerate realization of DARPA HOTS hard technical challenges.

SiC pressure sensor electronics high temperature↗

The first earth resources technology satellite nearly two years of operation

A brief status report on the performance of the ERTS-1, and an overview of the applications derived from the images are presented. The ERTS-1 spacecraft, sensor and picture processing systems have continued to perform almost flawlessly since August 1972. Registered, multispectral images of all major land masses of the earth, both polar and some oceanic regions are continuously made, covering daily an area of about 5 million square kilometers. The systematic repetition of these observations, which were made over most parts of the world at least once every season, and the high accuracy of thematic mapping that can be obtained from the images, have resulted in many applications that have immense potential benefits for developing countries. Among these applications are the detection and accurate mensuration of surface water; the identification and mensuration of forests, rangeland, crops and soils; the monitoring and mapping of water quality, wildlife habitats and of the effects of land use practices on food and water resources; the assessment of flooding and earthquake hazards; and the facilitation of mineral exploration.

Nordberg, W.↗

Laboratory-Based Thermal Shock Investigation of Heat Flux Sensors for the Mars 2020 Backshell

In 2012 during the entry, descent, and landing of the Mars Science Laboratory (MSL), the MSL Entry, Descent, and Landing Instrumentation (MEDLI) sensor suite was collecting in-flight heatshield pressure and temperature data. The data collected by the MEDLI instruments has since been used for reconstruction of vehicle aerodynamics, atmospheric conditions, aerothermal heating, and Thermal Protection System (TPS) performance as well as material response model validation and refinement. The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 heatshield and backshell is being designed to expand on the measurements and knowledge gained from MEDLI. Similar to MEDLI, MEDLI2 will measure the pressure and temperature of the heatshield. MEDLI2 will additionally measure the temperature, pressure, total heat flux, and radiative heat flux on the backshell.Since the backshell instrumentation is new to MEDLI2, Do No Harm (DNH) testing was conducted on instrumented backshell TPS (SLA-561V) panels. The panels consisted of four pressure port holes, one Mars Entry Atmospheric Data System (MEADS) pressure port plug, one MEDLI2 Integrated Sensor Plug (MISP) thermal plug, and one heat flux sensor. DNH testing was conducted to ensure the performance of the TPS was not degraded due to sensor integration and to characterize any TPS performance changes. The testing consisted of environmental testing— vibration, shock, thermal vacuum (TVAC) cycling— and bounding aerothermal (arc jet) testing. During arc jet testing, the heat flux sensors embedded in the SLA-561V panels exhibited an unexpected temporary reduction in the heat flux sensor temperature and response. After review of the test results, it was determined that this unexpected response was confined to the two heat flux sensors that experienced the greatest thermal shock condition. This condition consisted of a liquid nitrogen (LN2) bath that induced temperatures of approximately -190°C, and then a transition (thermal shock) to an arc jet test at a heat rate of approximately 21 W/cm2. Both heat flux sensors that were exposed to this thermal shock experienced a blister in the thermal coating during the arc jet test.Two heat flux sensor thermal shock test series were performed to investigate the cause of the blistering and subsequent energy release. In these tests, the heat flux sensor was first cold soaked in either a dry ice or LN2 bath to induce temperatures of approximately -78°C or -190°C, respectively. Then the sensors were thermally shocked using two propane torches with a heat rate of either approximately 8 W/cm2 or 21 W/cm2. The key findings indicated that there is a correlation between thermal shock and the blistering observed in the DNH test series, and that the cause appeared to be rooted in the heat flux sensor epoxy that encapsulates the sensor thermopile.Since the heat flux sensors are required to measure heat fluxes up to 15 W/cm2 during the Mars 2020 entry, a third test series was designed to determine if blistering is an issue at this maximum expected flight heat flux. Results from all three thermal shock test series and a discussion about whether or not blistering of the heat flux sensor thermal coating could be an issue for the Mars 2020 mission will be presented.

Miller, R. A.↗

Low Order Wavefront Sensing and Control for WFIRST-AFTA Coronagraph

To maintain the required WFIRST Coronagraph performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C use s the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading of the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST -AFTA Coronagraph. We will describe LOWFS/C's Zernike wavefront sensor concept and WFIRST LOWFS/C control design. We will present an overview of our analysis and modeling results on the Zernike wavefront sensor, the line -of-sight jitter suppression loop performance, as well as the low order wavefront error correction with the coronagraph's deformable mirror. In this paper we will also report the LOWFS/C testbed design and the preliminary in-air test results, which show a very promising performance of the Zernike wavefront sensor and FSM feedback loop.

exoplanets↗

Real-Time Sensor Validation, Signal Reconstruction, and Feature Detection for an RLV Propulsion Testbed

A real-time system for validating sensor health has been developed in support of the reusable launch vehicle program. This system was designed for use in a propulsion testbed as part of an overall effort to improve the safety, diagnostic capability, and cost of operation of the testbed. The sensor validation system was designed and developed at the NASA Lewis Research Center and integrated into a propulsion checkout and control system as part of an industry-NASA partnership, led by Rockwell International for the Marshall Space Flight Center. The system includes modules for sensor validation, signal reconstruction, and feature detection and was designed to maximize portability to other applications. Review of test data from initial integration testing verified real-time operation and showed the system to perform correctly on both hard and soft sensor failure test cases. This paper discusses the design of the sensor validation and supporting modules developed at LeRC and reviews results obtained from initial test cases.

Jankovsky, Amy L.↗