Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Evaluation of LINE-1 mobility in neuroblastoma cells by in vitro retrotransposition reporter assay: FACS analysis can detect only the tip of the iceberg of the inserted L1 elements

Long Interspersed Nuclear Elements (L1) are retroelements generally repressed in most differentiated somatic cells. Their activity has been observed in some undifferentiated and tumour cells and could be involved in tumour onset and progression. Growing evidences show that the L1 activation can occur in neuronal precursor cells during differentiation process. Neuroblastoma is a tumour originating from neuronal precursor cells, and, although the molecular basis of its progression is still poorly understood, the implication of L1 activation has not yet been investigated. In this study L1 mobility in neuroblastoma BE(2)C cells was assessed using the in vitro retrotransposition assay consisting in an episomal EGFP-tagged L1{sub RP} element, whose mobility can be evaluated by cytofluorimetric analysis (FACS) of EGFP expression. FACS results have shown a low retrotransposition activity. To detect L1{sub RP} integrated in transcriptionally repressed genomic sites, both a cell treatment with a stimulator of reporter gene promoter, and a quantitative Real-Time PCR analysis were performed. A retrotransposition activity ten and one thousand times that of FACS was found, respectively. These results point out that the real rate of L1 retrotransposition events in tumour cells might be considerably higher than that reported so far by evaluating only the reporter gene expression.

60 APPLIED LIFE SCIENCES↗

Standards and Protocols for Data Acquisition and Reporting for Studies of the Electrochemical Reduction of Carbon Dioxide

Objective evaluation of the performance of electrocatalysts for CO 2 reduction has been complicated by a lack of standardized methods for measuring and reporting activity data. In this perspective, we advocate that standardizing these practices can aid in advancing research efforts toward the development of efficient and selective CO 2 reduction electrocatalysts. Using information taken from experimental studies, we identify variables that influence the measured activity of CO 2 reduction electrocatalysts and propose procedures to account for these variables in order to improve the accuracy and reproducibility of reported data. We recommend that catalysts be measured under conditions which do not introduce artifacts from impurities, from either the electrolyte or counter electrode, and advocate the acquisition of data measured in the absence of mass transport effects. Furthermore, measured rates of electrochemical reactions should be normalized to both the geometric electrode area as well as the electrochemically active surface area to facilitate the comparison of reported catalysts with those previously known. We demonstrate that, when these factors are accounted for, the CO 2 reduction activities of Ag and Cu measured in different laboratories exhibit little difference. Furthermore, adoption of the recommendations presented in this perspective would greatly facilitate the identification of superior catalysts for CO 2 reduction arising solely from changes in their composition and pretreatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consensus statement for stability assessment and reporting for perovskite photovoltaics based on ISOS procedures

Improving the long-term stability of perovskite solar cells is critical to the deployment of this technology. Despite the great emphasis laid on stability-related investigations, publications lack consistency in experimental procedures and parameters reported. It is therefore challenging to reproduce and compare results and thereby develop a deep understanding of degradation mechanisms. Here, we report a consensus between researchers in the field on procedures for testing perovskite solar cell stability, which are based on the International Summit on Organic Photovoltaic Stability (ISOS) protocols. We propose additional procedures to account for properties specific to PSCs such as ion redistribution under electric fields, reversible degradation and to distinguish ambient-induced degradation from other stress factors. These protocols are not intended as a replacement of the existing qualification standards, but rather they aim to unify the stability assessment and to understand failure modes. Finally, we identify key procedural information which we suggest reporting in publications to improve reproducibility and enable large data set analysis.

14 SOLAR ENERGY↗

Flowback verses first-flush: new information on the geochemistry of produced water from mandatory reporting

Unconventional oil and gas development uses the subsurface injection of large amounts of a variety of industrial chemicals, and there are concerns about the return of these chemical to the surface with water produced with oil and gas from stimulated wells. Produced water, including any flowback of injected fluids, must be managed so as to protect human health and the environment, and understanding the chemistry of produced water from stimulated wells is necessary to ensure the safe management of produced water. In 2014, California instituted mandatory reporting for all well stimulations, including sampling produced water two times and comprehensive chemical characterization of fluids injected and fluids recovered from stimulated wells. In this study, we analyzed data from mandatory reporting with the objective of closing previously identified data gaps concerning oil-field chemical practices and the nature of flowback and produced water from stimulated wells. It was found that the plug-flow conceptual model of flowback developed in shale formations, where salinity increases over time as produced water is extracted, was not appropriate for characterizing produced water from unconventional wells in these oil reservoirs, which are predominately diatomite and sandstones. In these formations stimulation caused a "first-flush" phenomena, where salts and metals were initially high and then decreased in concentration over time, as more produced water was extracted. Although widely applied to meet regulatory requirements, total carbohydrate measurement was not found to be a good chemical indicator of hydraulic fracturing flowback. In conclusion, mandatory reporting closed data-gaps concerning chemical use, provided new information on acid treatments, and allowed more detailed analysis of hydraulic fracturing practices, including comparison of water use by geological formation.

54 ENVIRONMENTAL SCIENCES↗

Using ultra-fast spectroscopy to probe the excited state dynamics of a reported highly efficient thermally activated delayed fluorescence chromophore

Multiple ultrafast spectroscopic techniques and quantum chemical simulations (QCS) were used to investigate the excited state dynamics of BCC-TPTA. This organic chromophore is believed to possess excited state dynamics governed by a thermally activated delayed fluorescence (TADF) mechanism with a reported internal quantum efficiency (η IQE ) of 84%. In addition, a significant enhancement in its quantum yield (Φ) in solution after purging oxygen has been reported. This Φ enhancement has been widely accepted as due to a delayed fluorescence process occurring on the μs time-scale. The spectroscopic measurements were carried out both in solution and blended films, and from fs to μs time-scales. The excited state dynamics of Rhodamine B and Ir(BT) 2 (acac) were also probed for comparison. Investigations in the absence of oxygen were also carried out. Our time-correlated single photon counting (TCSPC) measurements revealed a lack of a long-lived emissive lifetime for BCC-TPTA in any of the media tested. Our ns transient absorption spectroscopy (ns TAS) experiments revealed that BCC-TPTA does not possess triplet transient states that could be linked to a delayed fluorescence process. Instead, the evidence obtained from our spectroscopic tools suggests that BCC-TPTA has the excited state dynamics of a typical fluorescence chromophore and that just comparing the Φ difference before and after purging oxygen from the solution is not an accurate method to claim excited state dynamics governed by a delayed fluorescence mechanism. Consequently, we believe that previous studies, in which the photo-physics of organic chromophores with TADF characteristics are reported, may have overlooked the influence of the host materials on the obtained optical properties in blended films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research on optimization of cooling structure of LED element (The 2nd report)

This report shows a design guideline on the parts dimension of LED light bulb for heat transfer. LED light bulb is popular owing to the high efficiency and long life. However, LED element is a point heat source. Therefore, LED light bulb has some problems about heat transfer when it is used for lighting. It sometimes causes deterioration by the raise of local temperature, resulting in lowering of efficiency and shorter life. Thus the thermal analysis focused on the number of element, all parts thickness, length, and radiant heat was studied, as systematic report on the points has not been found. In this report, heat radiation was taken into account in the thermal analysis in addition to natural heat convection. Furthermore the temperature of a heat sink model for LED light bulb was measured with thermocouples and thermo-viewer to verify the calculation. The emissivity of aluminum used for the calculation was 0.4. As the result of analysis, it was found that the maximum temperature was mainly influenced by ring length, ring diameter and disk thickness as a design guideline. Concretely, longer length, larger diameter and thicker disk gave lower temperature of LED element. The temperatures of the best and worst model were around 70 °C and 120 °C respectively in the above condition. The temperatures calculated were consistent with those in experiment.

42 ENGINEERING↗

Dosimetry and uncertainty approaches for the million person study of low-dose radiation health effects: overview of the recommendations in NCRP Report No. 178

Purpose: Scientific Committee 6–9 was established by the National Council on Radiation Protection and Measurements (NCRP), charged to provide guidance in the derivation of organ doses and their uncertainty, and produced a report, NCRP Report No. 178, Deriving Organ Doses and their Uncertainty for Epidemiologic Studies with a focus on the Million Person Study of Low-Dose Radiation Health Effects (MPS). This review summarizes the conclusions and recommendations of NCRP Report No. 178, with a concentration on and overview of the dosimetry and uncertainty approaches for the cohorts in the MPS, along with guidelines regarding the essential approaches used to estimate organ doses and their uncertainties (from external and internal sources) within the framework of an epidemiologic study. Conclusions: The success of the MPS is tied to the validity of the dose reconstruction approaches to provide realistic estimates of organ-specific radiation absorbed doses that are as accurate and precise as possible and to properly evaluate their accompanying uncertainties. Further, the dosimetry aspects for the MPS are challenging in that they address diverse exposure scenarios for diverse occupational groups being studied over a period of up to 70 y. Specific dosimetric reconstruction issues differ among the varied exposed populations that are considered: atomic veterans, U.S. Department of Energy workers exposed to both penetrating radiation and intakes of radionuclides, nuclear power plant workers, medical radiation workers, and industrial radiographers. While a major source of radiation exposure to the study population comes from external gamma- or x-ray sources, for some of the study groups, there is also a meaningful component of radionuclide intakes that requires internal radiation dosimetry assessments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report on progress in physics: observation of the Breit–Wheeler process and vacuum birefringence in heavy-ion collisions

This report reviews the effort over several decades to observe the linear Breit–Wheeler process ($\gamma\gamma \rightarrow e^+e^-$) and vacuum birefringence (VB) in high-energy particle and heavy-ion collider experiment. This report, motivated by the STAR collaboration's recent observations, attempts to summarize the key issues related to the interpretation of polarized $\gamma\gamma \rightarrow l^+l^-$ measurements in high-energy experiments. To that end, we start by reviewing the historical context and essential theoretical developments, before focusing on the decades of progress made in high-energy collider experiments. Special attention is given to the evolution in experimental approaches in response to various challenges, to the demanding detector capabilities required to unambiguously identify the linear Breit–Wheeler process, and to the connections with VB. Finally, we close the report with a discussion, followed by a look at near-future opportunities for utilizing these discoveries and for testing quantum electrodynamics in previously unexplored regimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NON-DETECTION OF PREVIOUSLY REPORTED TRANSITS OF HD 97658b WITH MOST PHOTOMETRY

The radial velocity-discovered exoplanet HD 97658b was recently announced to transit, with a derived planetary radius of 2.93 {+-} 0.28 R{sub Circled-Plus }. As a transiting super-Earth orbiting a bright star, this planet would make an attractive candidate for additional observations, including studies of its atmospheric properties. We present and analyze follow-up photometric observations of the HD 97658 system acquired with the Microvariability and Oscillations of STars space telescope. Our results show no transit with the depth and ephemeris reported in the announcement paper. For the same ephemeris, we rule out transits for a planet with radius larger than 2.09 R{sub Circled-Plus }, corresponding to the reported 3{sigma} lower limit. We also report new radial velocity measurements which continue to support the existence of an exoplanet with a period of 9.5 days, and obtain improved orbital parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Using ensembles and distillation to optimize the deployment of deep learning models for the classification of electronic cancer pathology reports

One of the goals of the Surveillance, Epidemiology, and End Results (SEER) program is to estimate incidence, prevalence, and mortality of all cancers. To that end, cancer registries across the country maintain a massive database of cancer pathology reports which contain rich information to understand cancer trends. However, these reports are stored in the form of unstructured text, and human annotators are required to read and extract relevant information. In this article, we show that existing deep learning models for automating information extraction from cancer pathology reports can be significantly improved by using ensemble model distillation. We found that by training multiple predictive models and transferring their knowledge to a single, low-resource model, we can reduce the number of highly confident wrong predictions. Our results show that our implemented methods could save 1000s of manual annotation hours.

60 APPLIED LIFE SCIENCES↗

Live-cell Imaging of Pol II Promoter Activity to Monitor Gene expression with RNA IMAGEtag reporters

We describe a ribonucleic acid (RNA) reporter system for live-cell imaging of gene expression to detect changes in polymerase II activity on individual promoters in individual cells. The reporters use strings of RNA aptamers that constitute IMAGEtags (Intracellular MultiAptamer GEnetic tags) that can be expressed from a promoter of choice. For imaging, the cells are incubated with their ligands that are separately conjugated with one of the FRET pair, Cy3 and Cy5. The IMAGEtags were expressed in yeast from the GAL1, ADH1 or ACT1 promoters. Transcription from all three promoters was imaged in live cells and transcriptional increases from the GAL1 promoter were observed with time after adding galactose. Expression of the IMAGEtags did not affect cell proliferation or endogenous gene expression. Advantages of this method are that no foreign proteins are produced in the cells that could be toxic or otherwise influence the cellular response as they accumulate, the IMAGEtags are short lived and oxygen is not required to generate their signals. The IMAGEtag RNA reporter system provides a means of tracking changes in transcriptional activity in live cells and in real time.

36 MATERIALS SCIENCE↗

Coarse-to-Fine Multi-Task Training of Convolutional Neural Networks for Automated Information Extraction from Cancer Pathology Reports

Information extraction and coding of free-text pathology reports is an important activity for cancer registries to support national cancer surveillance. Cancer registrars must process high volumes of pathology reports on an annual basis. In this study, we investigated an automated approach using a coarse-to-fine training of convolutional neural networks (CNNs) for extracting the primary site, histological grade and laterality from unstructured cancer pathology text reports. Our proposed training scheme consists of two stages. In the first stage, the multi-task learning (MTL) with hard parameter sharing approach is used to train a multi-task MT-CNN model for all the tasks. Then, the TM-CNN parameters are used to initialize a CNN model for each task to be fine trained individually using its corresponding dataset. The performance of our proposed model was compared against a state-of-the-art CNN and the commonly used SVM classifier. We observed that the proposed model consistently outperformed the base line models, especially for the less prevalent classes. Specifically, the proposed training approach achieved a micro-F score of 0.7749 over 12 ICD- O-3 topography codes which is a significant improvement as compared with state-of-the-art CNN (0.7101) and the SVM (0.6019) classifiers. Also, the results demonstrate the potential of the proposed method for handling class imbalance within each task. It significantly improves macro-F score by 24% and 12% of the primary site and histology grade tasks, respectively.

Alawad, Mohammed↗

Global Explainability of A Deep Abstaining Classifier for Cancer Pathology Reports

We present a global explainability method to characterize sources of errors in a real-world multitask deep abstaining classifier (DAC), in the context of cancer histology prediction. Our multitask classifier, currently deployed for automated annotation of cancer pathology reports from NCI-SEER registries, was trained and evaluated on 1.04 million hand-annotated samples and makes simultaneous predictions of cancer site, subsite, histology, laterality, and behavior for each report. The DAC framework enables the model to abstain on ambiguous reports and confusing classes to achieve the target accuracy on the retained (non-abstained) samples, but at the cost of decreased coverage. Requiring 97% accuracy on the histology task caused our model to retain only 22% of all samples, mostly the less ambiguous and common classes. Local explainability with the GradInp technique provided a computationally efficient way of obtaining contextual reasoning for hundreds of thousands of individual predictions. Our method, involving dimensionality reduction of approximately 13000 aggregated local explanations (ALE), offers a tractable path to true global explainability. It enabled identification of sources of errors in histology classification, globally, as hierarchical complexity among classes, label noise, insufficient information, and conflicting evidence. This suggests several strategies for iterative improvement of our DAC, including well-designed exclusion criteria, focused annotation, and reduced penalties for errors involving hierarchically related classes.

59 BASIC BIOLOGICAL SCIENCES↗

Insufficient reporting of x-ray photoelectron spectroscopy instrumental and peak fitting parameters (metadata) in the scientific literature

This study was motivated by earlier observations. It is a systematic examination of the adequacy of reporting of information (metadata) necessary to understand x-ray photoelectron spectroscopy (XPS) data collection and data analysis in the scientific literature. The information for this study was obtained from papers published in three high-quality journals over a six-month period in 2019 and throughout 2021. Each paper was evaluated to determine whether the authors had reported (percentages of the papers properly providing the information are given in parentheses) the spectrometer (66%), fitting software (15%), x-ray source (40%), pass energy (10%), spot size (5%), synthetic peak shapes in fits (10%), backgrounds in fits (10%), whether the XPS data are shown in the main body of the paper or in the supporting information (or both), and whether fitted or unfitted spectra were shown (80% of published spectra are fit). The Shirley background is the most widely used background in XPS peak fitting. The Al Kα source is the most widely used x-ray source for XPS data collection. CASAXPS is the most widely used fitting program for XPS data analysis. Further, there is good agreement between the results gathered during the two years of our survey. There are some hints the situation may be improving. This study also provides a list of the information/parameters that should be reported when XPS is performed.

47 OTHER INSTRUMENTATION↗

Case report of a near medical event in stereotactic radiotherapy due to improper units of measure from a treatment planning system

Purpose: The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. Methods: Using pretreatment imaging, the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. Results: Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. Conclusions: The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO

Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific {sup 192}Ir, {sup 137}Cs, and {sup 60}Co source models. Methods: This report has been prepared by the High Energy Brachytherapy Source Dosimetry (HEBD) Working Group. This report includes considerations in the application of the TG-43U1 formalism to high-energy photon-emitting sources with particular attention to phantom size effects, interpolation accuracy dependence on dose calculation grid size, and dosimetry parameter dependence on source active length. Results: Consensus datasets for commercially available high-energy photon sources are provided, along with recommended methods for evaluating these datasets. Recommendations on dosimetry characterization methods, mainly using experimental procedures and Monte Carlo, are established and discussed. Also included are methodological recommendations on detector choice, detector energy response characterization and phantom materials, and measurement specification methodology. Uncertainty analyses are discussed and recommendations for high-energy sources without consensus datasets are given. Conclusions: Recommended consensus datasets for high-energy sources have been derived for sources that were commercially available as of January 2010. Data are presented according to the AAPM TG-43U1 formalism, with modified interpolation and extrapolation techniques of the AAPM TG-43U1S1 report for the 2D anisotropy function and radial dose function.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-142: Automatic Linac Log File: Analysis and Reporting

Purpose: End to end QA for IMRT/VMAT is time consuming. Automated linac log file analysis and recalculation of daily recorded fluence, and hence dose, distribution bring this closer. Methods: Matlab (R2014b, Mathworks) software was written to read in and analyse IMRT/VMAT trajectory log files (TrueBeam 1.5, Varian Medical Systems) overnight, and are archived on a backed-up network drive (figure). A summary report (PDF) is sent by email to the duty linac physicist. A structured summary report (PDF) for each patient is automatically updated for embedding into the R&V system (Mosaiq 2.5, Elekta AG). The report contains cross-referenced hyperlinks to ease navigation between treatment fractions. Gamma analysis can be performed on planned (DICOM RTPlan) and treated (trajectory log) fluence distributions. Trajectory log files can be converted into RTPlan files for dose distribution calculation (Eclipse, AAA10.0.28, VMS). Results: All leaf positions are within +/−0.10mm: 57% within +/−0.01mm; 89% within 0.05mm. Mean leaf position deviation is 0.02mm. Gantry angle variations lie in the range −0.1 to 0.3 degrees, mean 0.04 degrees. Fluence verification shows excellent agreement between planned and treated fluence. Agreement between planned and treated dose distribution, the derived from log files, is very good. Conclusion: Automated log file analysis is a valuable tool for the busy physicist, enabling potential treated fluence distribution errors to be quickly identified. In the near future we will correlate trajectory log analysis with routine IMRT/VMAT QA analysis. This has the potential to reduce, but not eliminate, the QA workload.

60 APPLIED LIFE SCIENCES↗