Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Fast discharge in a plasma gun with hemispherical insulator

A method of creation of hot dense plasma is proposed. It is based on cumulation of a shockwave, which originates on a hemispherical surface of insulator of plasma gun. The results of first experiments are presented. The shock wave is driven by fast electrical discharge (dI/dt>10{sup 12} A/s). The inductive storage with semiconductor opening switch is used as a current driver. Time resolved pin-hole images and vacuum ultraviolet (vuv) spectra are studied. Shockwaves from hemispherical insulator with 4 mm radius create plasma with a form of column about 1 mm diameter and 3-4 mm length. vuv spectra contain the lines of Ar ions that corresponds to the electron temperature about 20 eV. Possible practical application is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sizing and burn time measurements of micron-sized metal powders

Detailed ignition and combustion mechanisms are needed to develop optimized propellant and energetic formulations using micron-sized metal powders, such as aluminum. Combustion researchers have traditionally used relatively coarse metal particles to characterize the burn time dependence on particle size. However, measurements of burn times for particles below 10 {mu}m in diameter are still needed for aluminum powders and other metal fuels. The apparatus described here sizes the particles just before the ignition event, providing a direct correlation between individual particle size and its burn time. Two lasers were utilized: a 785 nm laser diode for sizing the particles and a 125 W CO{sub 2} laser for particle ignition. The particles crossed the 785 nm laser beam just before crossing the CO{sub 2} laser beam. The particle size was determined from the amplitude of the scattered 785 nm light pulse. The burn time was determined from the duration of the visible light emission produced from the ignited particle. The in situ measured particle size distributions compared well with the size distributions measured for the same powders by a commercial instrument using low angle laser light scattering. Our measurements with two nominally spherical aluminum powders, suggest that the burn times increase from 0.5 to {approx}2.5 ms as the particle diameters increase from 3 to 8 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital ratemeter with fast response

Digital ratemeter that operates according to a self-adjusting algorithm, which at low rates automatically switches from a preset count to the preset time method, is proposed. It combines the good properties of both methods concerning the accuracy of the measured average counting rate and the response time to sudden changes of rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative displacement measurement of a nanotube cantilever with nanometer accuracy using epifluorescence microscopy

A method to measure the deflection of a nanotube cantilever with nanometer accuracy in an air or liquid environment is presented. We attached fluorescent dyes at the end of a nanotube to detect its deflection. The nanotube cantilever was fabricated with a multiwalled carbon nanotube that is attached to the end of an electrochemically etched tungsten tip, and it was imaged in an epifluorescence microscope system. The fluorescence intensity distribution of the fluorescent particles at the end of the nanotube was approximated with a Gaussian and fitted by least-squares method. Finally, we were able to measure the displacement of the nanotube cantilever during electrostatic actuation with positional accuracy of a few nanometers. This technique can be applied to a manipulator or a force transducer on related a few piconewton forces.

42 ENGINEERING↗

Time-of-flight observation of electron swarm in methane

This paper reports on the evolution of an isolated electron swarm, which is experimentally observed as spatial distributions at every moment. This observation is assumed to directly correspond to the conventional time-of-flight theory. We have measured the spatial distribution of electrons using a double-shutter technique in the drift tube, where a shutter electrode to collect electrons can be slid along the field (E/N) direction in order to capture a relative electron number at a certain range of location. As a typical parameter defined by this spatial distribution, the center-of-mass drift velocity (W{sub r}) is determined for methane gas. The result is compared with the mean-arrival-time drift velocity (W{sub m}) defined from the arriving electron number at fixed positions. We have also performed a theoretical analysis in which a Fourier transformed Boltzmann equation is solved to deduce both of the drift velocities from a dispersion relationship. The difference between W{sub r} and W{sub m} at high E/Ns (above 200 Td) is clearly ascertained in the experimental and theoretical investigations, which is attributable to the occurrence of ionization events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lindblad equations for strongly coupled populations and coherences in photosynthetic complexes

Recent experimental observations of time-resolved multidimensional signals in the light-harvesting antennae Fenna-Mathews-Olson [G. S. Engel et al., Nature (London) 446, 782 (2007)] show large oscillations of exciton populations coupled to the long-lived coherences. These effects may not be reproduced by the standard Redfield theory which assumes weak coupling to a bath. A more general relaxation superoperator which holds for all system-bath coupling parameter regimes is constructed by taking into account the statistics (covariances) of Lindblad equation parameters. Simulations for a model dimer reproduce all observed strong coupling effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cancellation of environmental effects in resonant mass sensors based on resonance mode and effective mass

A novel technique is developed to cancel the effect of environmental parameters, e.g., temperature and humidity, in resonant mass sensing. Utilizing a single resonator, the environmental cancellation is achieved by monitoring a pair of resonant overtones and the effective sensed mass in those overtones. As an eminent advantage, especially compared to dual-mode temperature compensation techniques, the presented technique eliminates any need for previously measured look-up tables or fitting the measurement data. We show that a resonant cantilever beam is an appropriate platform for applying this technique, and derive an analytical expression to relate the actual and effective sensed masses on a cantilever beam. Thereby, it is shown that in applying the presented technique successfully, the effective sensed masses must not be the same in the investigated pair of resonance overtones. To prove the feasibility of the proposed technique, flexural resonance frequencies of a silicon cantilever are measured before and after loading with a strip of photoresist. Applying the presented technique shows significant reductions in influence of environmental parameters, with the temperature and humidity coefficients of frequency being improved from -19.5 to 0.2 ppm deg. C{sup -1} and from 0.7 to -0.03 ppm %RH{sup -1}, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilization of the ionization overheating thermal instability in atmospheric pressure microplasmas

Stable direct current atmospheric pressure plasmas can regularly be generated in air using microplasma systems, and rapid cooling due to the small size is typically suggested as the thermally stabilizing mechanism. However, temperatures of the stable discharges are significantly higher than ambient, and stable operation is not easily achieved in all gases at similar sizes. Revisiting a traditional analysis of the thermal instability, we find that the inclusion of the simple ballasted external circuit in the analysis leads to additional stabilizing mechanisms. This stabilization occurs in microplasmas due to the characteristic times of the external circuit and the instability being comparable, which allows the electric field to change during the time frame of the instability. Experimentally this is implemented by reducing the stray capacitance of the external circuit. This stabilizing mechanism is verified in several gases and its application in a plasma enhanced chemical vapor deposition system leads to a more uniform film deposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the electron energy in the high power impulse magnetron sputtering discharge

The temporal variation of the electron energy distribution function (EEDF) was measured with a Langmuir probe in a high power impulse magnetron sputtering (HiPIMS) discharge at 3 and 20 mTorr pressures. In the HiPIMS discharge a high power pulse is applied to a planar magnetron giving a high electron density and highly ionized sputtered vapor. The measured EEDF is Maxwellian-like during the pulse; it is broader for lower discharge pressure and it becomes narrower as the pulse progresses. This indicates that the plasma cools as the pulse progresses, probably due to high metal content of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous transport induced by sheath instability in Hall effect thrusters

It is well recognized to ascribe the anomalous cross-field conductivity inside Hall-effect thrusters to fluctuation-induced transport due to gradient-driven instabilities (Rayleigh or electron drift) and to electron-wall interaction (near-wall conductivity). In this letter, we have performed numerical experiments showing the possibility of another mechanism inducing azimuthal fluctuations: the lateral sheath instability. It is created by a negative differential resistance of the current-voltage I-V characteristic of the floating wall as a consequence of high secondary electron emission. The contribution from this effect to the anomalous axial current is calculated and it accounts of more than 80% of the experimental value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy

The absolute force sensitivities of colloidal probes comprised of atomic force microscope, or AFM, cantilevers with microspheres attached to their distal ends are measured. The force sensitivities are calibrated through reference to accurate electrostatic forces, the realizations of which are described in detail. Furthermore, the absolute accuracy of a common AFM force calibration scheme, known as the thermal noise method, is evaluated. It is demonstrated that the thermal noise method can be applied with great success to colloidal probe calibration in air and in liquid to yield force measurements with relative standard uncertainties below 5%. Techniques to combine the electrostatics-based determination of the AFM force sensitivity with measurements of the colloidal probe's thermal noise spectrum to compute noncontact estimates of the displacement sensitivity and spring constant are also developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

A single-crystal silicon carbide (SiC) detector was used for measurements of soft x rays, electrons, and ion emission from laser-generated plasma obtained with the use of the Prague Asterix Laser System (PALS) at intensities of the order of 10{sup 16} W/cm{sup 2} and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the nature of the irradiated target. The spectra obtained by using the SiC detector show not only the photopeak due to UV and soft x-ray detection, but also various peaks due to the detection of energetic charged particles. Time-of-flight technique was employed to determine the ion kinetic energy of particles emitted from the plasma and to perform a comparison between SiC and traditional ion collectors. The detector was also employed by inserting absorber films of different thickness in front of the SiC surface in order to determine, as a first approximation, the mean energy of the soft x-ray emission from the plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizations of strip-line microwave micro atmospheric plasma and its application to neutralization

In this work, we estimate the plasma parameters of strip-line microwave micro atmospheric plasma (SMMAP) such as rotational temperature (T{sub r}) both from OH and N{sub 2} rotational transitions (610-770 and 770-980 K in Ar, respectively), electron density (N{sub e}) from Stark broadening (about 10{sup 13}/cm{sup 3} in mixture of Ar and H{sub 2}), and the distribution of electric field before ignition of SMMAP (5x10{sup 4} V/m at maximum, and applied voltage less than 5 V). Since the lower applied voltage of SMMAP might enable us to conduct efficient processing without electrostatic damage (ESD), we applied jet-type SMMAP to neutralization. The result of neutralization showed that it can reduce surface charge from +-1000 to +-100 V for 0.2 s at 10 W with Ar gas flow within 4 V offset voltage, which provides efficient plasma processing without ESD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of spectra unfolded for a filtered x-ray diode array with improved smoothness

An unfolding algorithm using parabolic B-splines to smoothly reconstruct the soft x-ray spectra from the measurements of a filtered x-ray diode array is proposed. This array has been fabricated for the study of the soft x ray emitted by Z-pinch plasma. Unfolding results show that for the simulated noise-free blackbody spectra with temperature ranging from 20 to 250 eV, both the spectra and the total power are accurately recovered. Typical experimental waveforms along with the unfolded spectra and total power of x rays are presented. Possible defects due to the adoption of parabolic B-splines instead of conventionally used histograms are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamics behavior of homogeneous dielectric barrier discharge at atmospheric pressure

An experimental study on the dynamics behavior of homogeneous dielectric barrier discharge (HDBD) at atmospheric pressure is described in this paper. Two kinds of discharge mode, glow and Townsend discharge modes, can be easily identified according to the differential conductivity of current-voltage relationship in the ascent stage of discharge current for the atmospheric HDBD. A (three-dimensional) 3D phase space made by discharge current, gas gap voltage, and charge density of dielectric-plate surface was utilized in the study. By projecting the discharge evolution trajectory in the 3D space, the 3D trajectory of multiple current peaks discharge in atmospheric helium shows a limited cycle with convolutions and undergoes a series of bifurcation process; however, the 3D trajectory of atmospheric N{sub 2} HDBD is a limited cycle without any convolution and bifurcation process. In addition, the first ionization coefficient of working gas plays a key role to determine the discharge mode of atmospheric HDBD, the transition of discharge mode and the dynamics stability of atmospheric HDBD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise characteristics of the gas ionization cascade used in low vacuum scanning electron microscopy

The noise characteristics of gas cascade amplified electron signals in low vacuum scanning electron microscopy (LVSEM) are described and analyzed. We derive expressions for each component contributing to the total noise culminating in a predictive, quantitative model that can be used for optimization of LVSEM operating parameters. Signal and noise behavior is characterized experimentally and used to validate the model. Under most operating conditions, the noise is dominated by the excess noise generated in the gas amplification cascade. At high gains, the excess noise increases proportionally with gain such that the signal-to-noise ratio is constant. The effects of several instrument operating parameters, including working distance, gas pressure, beam current, and detector bias, are condensed and presented in the form of a master curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism of laser and rf plasma in vibrational nonequilibrium CO-N{sub 2} gas mixture

This paper investigates the mechanism of plasma created by focused CO laser and rf electric field. The plasma is created in a CO/N{sub 2} environment, at a total pressure of 600 torr. Ionization of the gases occurs by an associative ionization mechanism, in collisions of two highly vibrationally excited molecules. These highly vibrationally excited states are populated by resonance absorption of the CO radiation followed by anharmonic vibration-vibration (V-V) pumping. Moreover N{sub 2} also becomes vibrationally excited due to collisions with vibrationally excited CO. The coupled rf reduced electric field E/N is sufficiently low to prevent electron impact ionization that may create plasma individually, so when a subbreakdown rf field is applied to the plasma, collisions between the free electrons heated by the field and the diatomic species create additional vibrational excitation both in the region occupied by the CO laser beam and outside of the laser beam region. The numerical results show plasma created in both regions (in and out of the CO laser beam region) with the associative ionization mechanism. This suggests a method for creating a stable nonequilibrium plasma. The calculation result is verified by comparison the synthetic spectrum to a measured one.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonthermal effects on the symmetric resonant charge transfer in Lorentzian plasmas

The nonthermal and plasma screening effects on the symmetric resonant charge transfer process are investigated in Lorentzian plasmas. It is shown that the nonthermal character of the Lorentzian plasma enhances the symmetric resonant charge transfer probability as well as the charge transfer cross section. The plasma screening effects on the charge transfer cross section are found to be quite significant for small values of the spectral index. In addition, the nonthermal effects on the symmetric resonant charge transfer process are found to be more significant in Lorentzian plasmas with higher densities. It is also shown that the nonthermal character of the Lorentzian plasmas enhances the rate coefficient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗