At least 1,513 records · Page 84

Vibroacoustic Process Monitoring of 5-Stage Centrifugal Contactors

Vibroacoustic monitoring was investigated to aid in informing process operators with parameters regarding aqueous separation techniques. These techniques have a wide range of applications including nuclear fuel reprocessing. A small-scale solvent extraction system was set up with five magnetic drive contactors and two piston pumps to collect realistic operation. Vibration sensors were placed on three of the contactors and both pumps, and a microphone was placed near the system. Contactor rotational speed and pump flow rate were varied with known values to compare against measured vibroacoustic signatures. Spectral analysis allowed for the determination of contactor rotational speed and the ratio of organic to aqueous flow rate, an important parameter for ensuring optimal extraction. Vibration metrics such as kurtosis and crest factor provided additional details regarding individual rotational speeds and have potential in examination of faults for predictive maintenance. Overall, results indicate the capability of vibroacoustic monitoring to improve operator awareness and process outcomes.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Programa de Diseno, Fabricacion y Pruebas del Sistema de Desalinizacion por Olas del NREL: Preprint (Spanish Translation)

To de-risk the U.S. Department of Energy's Waves to Water Prize, the National Renewable Energy Laboratory (NREL) developed a modular, wave powered desalination system. The prize was open to wave energy converter (WEC) designs that generate electricity or WECs that desalinate water mechanically. This added installation risks due to the variance in competitor devices, and the aggressive installation timeline. To reduce these risks NREL developed a wave energy converter (WEC) that the installation team could use to practice installation techniques prior to the competitors arriving to ensure all steps had been considered prior to the event. This was achieved by developing a WEC with a modular power-take-off (PTO). The modular PTO can be configured in one configuration to drive an electric generator that sends electricity to a pier. The electricity that is generated is converted, and stored, so that it can be used to power an electric pump that feeds water to a Reverse Osmosis (RO) desalination unit. In the other configuration the generator is replaced with a pump and seawater is pumped to the RO system on the pier without any electrons being generated. This WEC is formally known as the Hydraulic and Electric Reverse Osmosis (HERO) WEC. For the English version of this report, see NREL/CP-5700-86623 (https://www.nrel.gov/docs/fy24osti/86623.pdf).

laboratory testing↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Modelling Nuclear Thermal Propulsion Reactor Expander Cycle Startup Transients

As the interest in nuclear thermal propulsion grows, the need for high fidelity and comprehensive models of the system increases. An expander cycle model was developed using RELAP-7 for the thermal-hydraulic performance and Griffin to provide the power level using a point kinetics approximation, for a reference NTP system. The tank and pump are approximated using boundary conditions. Flow is split between the moderator cooling channels flow path and the regenerative cooling/reflector cooling channels flow path. The flow recombines before entering the turbine and the fuel cooling channels. The turbine pressure ratio is maintained at 1.44 using a PID controller. A startup transient was simulated and shows the capability of the model to run from low temperature and pressures to nominal conditions.

33 ADVANCED PROPULSION SYSTEMS↗

Gas Retention, Gas Release, and Fluidization of Spherical Resorcinol-Formaldehyde (sRF) Ion Exchange Resin

The Low-Activity Waste Pretreatment System (LAWPS) is being developed to provide treated supernatant liquid from the Hanford tank farms directly to the Low-Activity Waste (LAW) Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant. The design and development of the LAWPS is being conducted by Washington River Protection Solutions, LLC. A key process in LAWPS is the removal of radioactive Cs from LAW liquids using ion exchange (IX) columns filled with spherical resorcinol-formaldehyde (sRF) resin. When loaded with radioactive Cs, radiolysis of water in the LAW liquid will generate hydrogen gas. In normal operations, the generated hydrogen is expected to remain dissolved in the liquid and be continuously removed by liquid flow. One accident scenario being evaluated is the loss of liquid flow through the sRF resin bed after it has been loaded with radioactive Cs and hydrogen gas is being generated by radiolysis. For an accident scenario with a loss of flow, hydrogen gas can be retained within the IX column both in the sRF resin bed and below the bottom screen that supports the resin within the column, which creates a hydrogen flammability hazard. Because there is a potential for a large fraction of the retained hydrogen to be released over a short duration as a gas release event, there is a need to quantify the size and rate of potential gas release events. Due to the potential for a large, rapid gas release event, an evaluation of mitigation methods to eliminate the hydrogen hazard is also needed. One method being considered for mitigating the hydrogen hazard during a loss of flow accident is to have a secondary flow system, with two redundant pumps operating in series, that re-circulates liquid upwards through the bed and into a vented break tank where hydrogen gas is released from the liquid and removed by venting the headspace of the break tank. The mechanism for inducing release of gas from the sRF bed is to fluidize the bed, which should allow retained bubbles to rise and be carried to the break tank. Currently, neither the ability of fluidizing a settled sRF bed to release gas nor the quantity of hydrogen gas that can be retained and the corresponding potential for large, rapid gas release events has been tested and evaluated. Accordingly, the purpose of this study was to conduct experiments and develop models that evaluate the ability of a re-circulating flow system to fluidize an sRF resin bed as a method to release retained hydrogen gas and maintain hydrogen gas retention at low levels, thereby avoiding conditions where hydrogen gas poses a flammability hazard. The purpose of the study was also to determine if effective hydrogen gas release would occur using a single constant fluidization velocity, because this is the most simple safety system to implement, for the range of fluid and sRF resin conditions anticipated in the column (because a velocity that is effective for one fluid/resin pair can be ineffective for different resin/fluid pairs). Finally, the study also included quantifying the volume of gas that can be retained in an sRF bed and the behavior of spontaneous, rather than fluidization-induced, gas release events.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the importance of electron impact processes in excimer-pumped alkali laser-induced plasmas

We present that the excimer-pumped alkali laser (XPAL) system has recently been demonstrated in several different mixtures of alkali vapor and rare gas. Without special preventive measures, plasma formation during operation of XPAL is unavoidable. Some recent advancements in the availability of reliable data for electron impact collisions with atoms and molecules have enabled development of a complete reaction mechanism to investigate XPAL-induced plasmas. Here, we report on pathways leading to plasma formation in an Ar/C 2 H 6 /CsAr/C2H6/Cs XPAL sustained at different cell temperatures. We find that depending on the operating conditions, the contribution of electron impact processes can be as little as bringing the excitation of Cs(P 2 ) states to higher level Cs** states, and can be as high as bringing Cs(P 2 ) excited states to a full ionization. Increasing the input pumping power or cell temperature, or decreasing the C 2 H 6 mole fraction leads to electron impact processes dominating in plasma formation over the energy pooling mechanisms previously reported in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of the small-scale prototype of the dew point water recovery system

The article presents experimental investigation of the Dew Point Water Recovery (DPWR) system designed for clean water recovery using the dew point cooling phenomenon. The technology is a novel distillation process which allows for highly efficient water recovery. It is a first distillation technology which allows for water distillation through direct contact with atmospheric air. The authors designed, built, and tested an original prototype of a laboratory-scale DPWR system to verify its basic operating principles and perform performance analysis. It was shown that on average 10 × 10 −6 m 3 of clean water could be recovered from each cubic meter of the supply air with an average GOR of 1.9. Although the operation of the DPWR system requires electricity to drive fans, pumps and other associated equipment, the actual driving force of the system is thermal energy. The average thermal energy demand of the DPWR system was 370 kWh/m 3 , and more than half of this energy was based on the thermodynamic potential of the supply air. Based on experimental data, the mathematical model of the DPWR system was verified and it was found that the average relative discrepancy in predicting air temperature did not exceed 8%, and in predicting air humidity: 5%. In conclusion, the conducted experiments confirmed that the proposed DPWR system is feasible and has the potential to fill the technological gap in terms of a low-energy and easily accessible water recovery method.

42 ENGINEERING↗

Multiterawatt femtosecond laser system with kilohertz pulse repetition rate

The basic principles, layout and components are presented for a multiterawatt femtosecond laser system with a kilohertz pulse repetition rate f, based on their parametric amplification and laser amplification of picosecond radiation that pumps the stages of the parametric amplifier. The results of calculations for a step-by-step increase in the output power from the LBO crystal parametric amplifier channel up to the multiterawatt level are presented. By using the developed components in the pump channel of the laser system, the parameters of the regenerative amplifier with the output energy ∼1 mJ at the wavelength 1030 nm and with f = 1 kHz are experimentally studied. The optical scheme of the diode-pumped multipass cryogenic Yb:Y{sub 2}O{sub 3} laser ceramic amplifier is developed and its characteristics are determined that provide the output energy within the range 0.25 – 0.35 J. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced High-Temperature Reactor Dynamic System Model Development: April 2012 Status

The Advanced High-Temperature Reactor (AHTR) is a large-output fluoride-salt-cooled high-temperature reactor (FHR). An early-phase preconceptual design of a 1500 MW(e) power plant was developed in 2011 [Refs. 1 and 2]. An updated version of this plant is shown as Fig. 1. FHRs feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR is designed to be a “walk away” reactor that requires no action to prevent large off-site releases following even severe reactor accidents. This report describes the development of dynamic system models used to further the AHTR design toward that goal. These models predict system response during warmup, startup, normal operation, and limited off-normal operating conditions. Severe accidents that include a loss-of-fluid inventory are not currently modeled. The scope of the models is limited to the plant power system, including the reactor, the primary and intermediate heat transport systems, the power conversion system, and safety-related or auxiliary heat removal systems. The primary coolant system, the intermediate heat transport system and the reactor building structure surrounding them are shown in Fig. 2. These systems are modeled in the most detail because the passive interaction of the primary system with the surrounding structure and heat removal systems, and ultimately the environment, protects the reactor fuel and the vessel from damage during severe reactor transients. The reactor silo also plays an important role during system warmup. The dynamic system modeling tools predict system performance and response. The goal is to accurately predict temperatures and pressures within the primary, intermediate, and power conversion systems and to study the impacts of design changes on those responses. The models are design tools and are not intended to be used in reactor qualification. The important details to capture in the primary system relate to flows within the reactor vessel during severe events and the resulting temperature profiles (temperature and duration) for major components. Critical components include the fuel, reactor vessel, primary piping, and the primary-to-intermediate heat exchangers (P-IHXs). The major AHTR power system loops are shown in Fig. 3. The intermediate heat transfer system is a group of three pumped salt loops that transports the energy produced in the primary system to the power conversion system. Two dynamic system models are used to analyze the AHTR. A Matlab/Simulink-based model initiated in 2011 has been updated to reflect the evolving design parameters related to the heat flows associated with the reactor vessel. The Matlab model utilizes simplified flow assumptions within the vessel and incorporates an empirical representation of the Direct Reactor Auxiliary Cooling System (DRACS). A Dymola/Modelica model incorporates a more sophisticated representation of primary coolant flow and a physics-based representation of the three-loop DRACS thermal hydraulics. This model is not currently operating in a fully integrated mode. The Matlab model serves as a prototype and provides verification for the Dymola model, and its use will be phased out as the Dymola model nears completion. The heat exchangers in the system are sized using spreadsheet-based, steady-state calculations. The detail features of the heat exchangers are programmed into the dynamic models, and the overall dimensions are used to generate realistic plant designs. For the modeling cases where the emphasis is on understanding responses within the intermediate and primary systems, the power conversion system may be modeled as a simple boundary condition at the intermediate-to-power conversion system heat exchangers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TC-2 post Helios experiment data review

Data are presented from a systems postflight analysis of the Centaur Launch Vehicle and Helios. Also given is a comparison of data from preflight analyses. Topics examined are: (1) propellant behavior; (2) helium usage; (3) propellant tank pressurization; (4) propellant tank thermodynamics; (5) component heating; thermal control; and thermal protection system; (6) main engine system; (7) H2O2 consumption; (8) boost pump post-meco performance; and (9) an overview of other systems.

Source record↗

Blender Pump Fuel Survey: CRC Project E-95-2

With the increasing fuel diversity in the marketplace, the Coordinating Research Council and the U.S. Department of Energy's National Renewable Energy Laboratory conducted a survey of mid-level ethanol blends (MLEBs) in the market. A total of 73 fuel samples were collected from 20 retail stations. To target Class 4 volatility, the fuel samples were collected primarily in the midwestern United States in the month of February. Samples included the gasoline (E0), Flex Fuel, and every MLEB that was offered from each of the 20 stations. Photographs of each station were taken at the time of sample collection, detailing the pump labeling and configuration. The style and labeling of the pump, hose, and dispenser nozzle are all important features to prevent misfueling events. The physical location of the MLEB product relative to the gasoline product can also be important to prevent misfueling. In general, there were many differences in the style and labeling of the blender pumps surveyed in this study. All samples were analyzed for volatility and ethanol content. For the MLEB samples collected, the fuels tended to be lower in ethanol content than their indicated amount; however, the samples were all within 10 vol% of their indicated blend level. One of the 20 Flex Fuel samples was outside of the allowable limits for ethanol content. Four of the 20 Flex Fuel samples had volatility below the minimum requirement for Class 4.

30 DIRECT ENERGY CONVERSION↗

KIPT ADS Target Cooling Analyses by MCNP/Fluent

This report presents multi-physics analyses of the target cooling system of the accelerator driven system (ADS) of the Kharkiv Institute of Physics and Technology (KIPT) using MCNP and Fluent computer programs. MCNP has been used to transport electrons, gammas, and neutrons, and to calculate the energy deposition in the target using a mesh-tally. The mesh-tally data have been imported in Fluent by a C subroutine that has been compiled and linked to Fluent as a user defined function. The KIPT ADS is in operation and Fluent used the CAD model from the manufacturing process of the target. The Fluent results for the reference case match very well the literature results obtained by STAR-CCM+ during the design phase. Other cases that differ from the reference one have been analyzed; in these cases, it is assumed a malfunction of the electron accelerator control or the primary water coolant pump. The target cooling system operates normally for all the analyzed cases except when the inlet water mass flow rate is decreased. If the water coolant mass flow decreases to 25%, the water maximum temperature exceeds the boiling point. However, the transient analysis showed that the target cooling system can operate for 180 seconds when the inlet water mass flow rate is decreased down by 50%.

42 ENGINEERING↗

Heat-pump driven desiccant regeneration

Disclosed herein are systems and processes to thermally regenerate and re-concentrate a liquid desiccant (absorbent) with an electrically driven heat pump. The regeneration and re-concentration may be performed in a cost and energy efficient manner.

Woods, Jason David↗

NASA Tech Briefs, September 2008

Topics covered include: Nanotip Carpets as Antireflection Surfaces; Nano-Engineered Catalysts for Direct Methanol Fuel Cells; Capillography of Mats of Nanofibers; Directed Growth of Carbon Nanotubes Across Gaps; High-Voltage, Asymmetric-Waveform Generator; Magic-T Junction Using Microstrip/Slotline Transitions; On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz; Group-III Nitride Field Emitters; HEMT Amplifiers and Equipment for their On-Wafer Testing; Thermal Spray Formation of Polymer Coatings; Improved Gas Filling and Sealing of an HC-PCF; Making More-Complex Molecules Using Superthermal Atom/Molecule Collisions; Nematic Cells for Digital Light Deflection; Improved Silica Aerogel Composite Materials; Microgravity, Mesh-Crawling Legged Robots; Advanced Active-Magnetic-Bearing Thrust- Measurement System; Thermally Actuated Hydraulic Pumps; A New, Highly Improved Two-Cycle Engine; Flexible Structural-Health-Monitoring Sheets; Alignment Pins for Assembling and Disassembling Structures; Purifying Nucleic Acids from Samples of Extremely Low Biomass; Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery; UV-Resistant Non-Spore-Forming Bacteria From Spacecraft-Assembly Facilities; Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy; Simplified Modeling of Oxidation of Hydrocarbons; Near-Field Spectroscopy with Nanoparticles Deposited by AFM; Light Collimator and Monitor for a Spectroradiometer; Hyperspectral Fluorescence and Reflectance Imaging Instrument; Improving the Optical Quality Factor of the WGM Resonator; Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking; Transmissive Diffractive Optical Element Solar Concentrators; Delaying Trains of Short Light Pulses in WGM Resonators; Toward Better Modeling of Supercritical Turbulent Mixing; JPEG 2000 Encoding with Perceptual Distortion Control; Intelligent Integrated Health Management for a System of Systems; Delay Banking for Managing Air Traffic; and Spline-Based Smoothing of Airfoil Curvatures.

Source record↗

Mass and power estimates for Mars in-situ propellant production systems

An in-situ propellant production (ISPP) concept, a method for producing oxygen from carbon dioxide in the Martian atmosphere, is evaluated. The concept considered here employs zirconia membrane technology to separate O2 from CO2. Several options which can improve the reliability of the CO2/O2 ISPP system and also reduce the mass and power requirements are examined, and it is noted that the use of absorption pumps and advanced zirconia membranes significantly improves system reliability by eliminating the rotating turbomachinery of mechanical pumps. Mass and power requirements of ISPP systems designed to produce O2 only from CO2 (for an unmanned Mars mission) and to produce both CO and O2 from CO2 (for a manned Mars mission) are evaluated.

Frisbee, R. H.↗

Note: A novel normalization scheme for laser-based plasma x-ray sources

A kHz repetition rate laser pump-X-ray probe system for ultrafast X-ray diffraction is set up based on a laser-driven plasma X-ray source. A simple and reliable normalization approach has been developed to minimize the impact of large X-ray pulse intensity fluctuation on data quality. It utilizes one single X-ray area detector to record both sample and reference signals simultaneously. Performance of this novel normalization method is demonstrated in reflectivity oscillation measurement of a superlattice sample at sub-ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical Property Measurements of Laboratory Prepared Saltstone Grout

The Saltstone Production Facility (SPF) built two new Saltstone Disposal Units (SDU), SDU 3 and SDU 5, in 2013. The variable frequency drive (VFD) for the grout transfer hose pump tripped due to high current demand by the motor during the initial radioactive saltstone transfer to SDU 5B on 12/5/2013. This was not observed during clean cap processing on July 5, 2013 to SDU 3A, which is a slightly longer distance from the SPF than is SDU 5B. Saltstone Design Authority (SDA) is evaluating the grout pump performance and capabilities to transfer the grout processed in SPF to SDU 3/5. To assist in this evaluation, grout physical properties are required. At this time, there are no rheological data from the actual SPF so the properties of laboratory prepared samples using simulated salt solution or Tank 50 salt solution will be measured. The physical properties of grout prepared in the laboratory with de-ionized water (DI) and salt solutions were obtained at 0.60 and 0.59 water to premix (W/P) ratios, respectively. The yield stress of the DI grout was greater than any salt grout. The plastic viscosity of the DI grout was lower than all of the salt grouts (including salt grout with admixture). When these physical data were used to determine the pressure drop and fluid horsepower for steady state conditions, the salt grouts without admixture addition required a higher pressure drop and higher fluid horsepower to transport. When 0.00076 g Daratard 17/g premix was added, both the pressure drop and fluid horsepower were below that of the DI grout. Higher concentrations of Daratard 17 further reduced the pressure drop and fluid horsepower. The uncertainty in the single point Bingham Plastic parameters is + 4% of the reported values and is the bounding uncertainty. Two different mechanical agitator mixing protocols were followed for the simulant salt grout, one having a total mixing time of three minutes and the other having a time of 10 minutes. The Bingham Plastic parameters were essentially the same for the salt grout without admixture. When Daratard 17 was added, the Bingham Plastic yield stress increased for the 10 minute mix. The simulant salt used in this task had similar physical properties of the Tank 50 3Q13 salt grout and is recommended for future use, if the salt solution in Tank 50 does not change. The design basis physical properties used to size the pumps and mixers at SPF were obtained from DPST-85-312. The grouts characterized in this report are bounded by the design basis density and Bingham Plastic yield stress. The opposite is true for the plastic viscosity. Steady state pressure drop calculations were performed for the design basis values using the flow rate for the clean cap and salt grouts and they bound the pressure drop of the grouts characterized in this report. A comparison of the lab prepared samples to PI ProcessBook data, specifically average pressure drop, indicate that the lab prepared samples are more viscous in nature than what is processed in the facility. This difference could be due to the applied shear rates which could be lower in the lab as compared to the facility and that fact the SPF added flush water, making this comparison more difficult. A perfunctory review of the PI ProcessBook data was discussed. It may be possible that the frequency that the distributed control system alters the grout pump speed to maintain grout hopper volume can negatively affect the efficiency of the grout pump.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Site 300 City Water Master Plan

Lawrence Livermore National Laboratory (LLNL), a scientific research facility, operates an experimental test site known as Site 300. The site is located in a remote area of southeastern Alameda County, California, and consists of about 100 facilities spread across 7,000-acres. The Site 300 water system includes groundwater wells and a system of storage tanks, booster pumps, and underground piping to distribute water to buildings and significant areas throughout the site. Site 300, which is classified as a non-transient non-community (NTNC) water system, serves approximately 110 employees through 109 service connections. The distribution system includes approximately 76,500-feet of water mains varying from 4- to 10-inches in diameter, mostly asbestos cement (AC) pipe, and eleven water storage tanks. The water system is divided into four pressure zones fed by three booster pump stations to tanks in each zone.

42 ENGINEERING↗