Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “planning optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Coupling multi-fidelity xRAGE with machine learning for graded inner shell design optimization in double shell capsules

Bayesian optimization has shown promise for the design optimization of inertial confinement fusion targets. Specifically, in Vazirani et al. [Phys. Plasmas 28 , 122709 (2021)], optimal designs for double shell capsules with graded inner shells were identified using one-dimensional xRAGE simulation yield calculations. While the machine learning models were able to accurately learn and predict one-dimensional simulation target performance, using simulations with higher fidelity would improve design optimization and better match with the expected experimental performance. However, higher fidelity physics modeling, i.e., two-dimensional xRAGE simulations, requires significantly larger computational time/cost, usually at least an order of magnitude, in comparison with one-dimensional simulations. This study presents a multi-fidelity Bayesian optimization, in which the machine learning model leverages low-fidelity (one-dimensional xRAGE) and high-fidelity (two-dimensional xRAGE) simulations to more accurately predict “pre-shot” target performance with respect to the expected experimental performance. By building a multi-fidelity Bayesian optimization framework coupled with xRAGE, the low-fidelity and high-fidelity simulations are able to inform one another, such that we have: (1) improved physics modeling in comparison with using low-fidelity simulations alone, (2) reduced computational time/cost in comparison with using high-fidelity simulations alone, and (3) more confidence in the expected performance of optimized targets during real-world experiments. In the future, we plan to use this robust multi-fidelity Bayesian optimization methodology to expedite the design of graded inner shells further and eventually full capsules as a part of the current double shell campaign at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-G-JeP2-01: A New Approach for MR-Only Treatment Planning: Tissue Segmentation-Based Pseudo-CT Generation Using T1-Weighted MRI

Purpose: To evaluate MR-only treatment planning for brain Stereotactic Ablative Radiotherapy (SABR) based on pseudo-CT (pCT) generation using one set of T1-weighted MRI. Methods: T1-weighted MR and CT images from 12 patients who were eligible for brain SABR were retrospectively acquired for this study. MR-based pCT was generated by using a newly in-house developed algorithm based on MR tissue segmentation and voxel-based electron density (ED) assignment (pCTv). pCTs using bulk density assignment (pCTb where bone and soft tissue were assigned 800HU and 0HU,respectively), and water density assignment (pCTw where all tissues were assigned 0HU) were generated for comparison of ED assignment techniques. The pCTs were registered with CTs and contours of radiation targets and Organs-at-Risk (OARs) from clinical CT-based plans were copied to co-registered pCTs. Volumetric-Modulated-Arc-Therapy(VMAT) plans were independently created for pCTv and CT using the same optimization settings and a prescription (50Gy/10 fractions) to planning-target-volume (PTV) mean dose. pCTv-based plans and CT-based plans were compared with dosimetry parameters and monitor units (MUs). Beam fluence maps of CT-based plans were transferred to co-registered pCTs, and dose was recalculated on pCTs. Dose distribution agreement between pCTs and CT plans were quantified using Gamma analysis (2%/2mm, 1%/1mm with a 10% cut-off threshold) in axial, coronal and sagittal planes across PTV. Results: The average differences of PTV mean and maximum doses, and monitor units between independently created pCTv-based and CT-based plans were 0.5%, 1.5% and 1.1%, respectively. Gamma analysis of dose distributions of the pCTs and the CT calculated using the same fluence map resulted in average agreements of 92.6%/79.1%/52.6% with 1%/1mm criterion, and 98.7%/97.4%/71.5% with 2%/2mm criterion, for pCTv/CT, pCTb/CT and pCTw/CT, respectively. Conclusion: Plans produced on Voxel-based pCT is dosimetrically more similar to CT plans than bulk assignment-based pCTs. MR-only treatment planning using voxel-based pCT generated from T1-wieghted MRI may be feasible.

60 APPLIED LIFE SCIENCES↗

Optical systems integrated modeling

An integrated modeling capability that provides the tools by which entire optical systems and instruments can be simulated and optimized is a key technology development, applicable to all mission classes, especially astrophysics. Many of the future missions require optical systems that are physically much larger than anything flown before and yet must retain the characteristic sub-micron diffraction limited wavefront accuracy of their smaller precursors. It is no longer feasible to follow the path of 'cut and test' development; the sheer scale of these systems precludes many of the older techniques that rely upon ground evaluation of full size engineering units. The ability to accurately model (by computer) and optimize the entire flight system's integrated structural, thermal, and dynamic characteristics is essential. Two distinct integrated modeling capabilities are required. These are an initial design capability and a detailed design and optimization system. The content of an initial design package is shown. It would be a modular, workstation based code which allows preliminary integrated system analysis and trade studies to be carried out quickly by a single engineer or a small design team. A simple concept for a detailed design and optimization system is shown. This is a linkage of interface architecture that allows efficient interchange of information between existing large specialized optical, control, thermal, and structural design codes. The computing environment would be a network of large mainframe machines and its users would be project level design teams. More advanced concepts for detailed design systems would support interaction between modules and automated optimization of the entire system. Technology assessment and development plans for integrated package for initial design, interface development for detailed optimization, validation, and modeling research are presented.

Shannon, Robert R.↗

Joint Chance-Constrained Dynamic Programming

This paper presents a novel dynamic programming algorithm with a joint chance constraint, which explicitly bounds the risk of failure in order to maintain the state within a specified feasible region. A joint chance constraint cannot be handled by existing constrained dynamic programming approaches since their application is limited to constraints in the same form as the cost function, that is, an expectation over a sum of one-stage costs. We overcome this challenge by reformulating the joint chance constraint into a constraint on an expectation over a sum of indicator functions, which can be incorporated into the cost function by dualizing the optimization problem. As a result, the primal variables can be optimized by a standard dynamic programming, while the dual variable is optimized by a root-finding algorithm that converges exponentially. Error bounds on the primal and dual objective values are rigorously derived. We demonstrate the algorithm on a path planning problem, as well as an optimal control problem for Mars entry, descent and landing. The simulations are conducted using a real terrain data of Mars, with four million discrete states at each time step.

Ono, Masahiro↗

Applying Constrained Bayesian Optimization to the Design of Critical Experiments

Often when planning a criticality experiment, many design configurations are iteratively investigated with a Monte Carlo transport code. The goal is that the experiment will be optimal with respect to some variable, like the fraction of fissions occurring at a certain energy range, while simultaneously being critical. Unfortunately, the Monte Carlo transport simulations are expensive, which can ultimately limit the number of configurations that can be explored. In this work, we present how Gaussian processes (GPs) can be used as a reduced-order model in a constrained Bayesian optimization (CBO) algorithm to design a criticality experiment. The GPs replace the Monte Carlo transport simulations that explore the design space. The CBO algorithm efficiently identifies new points in the design space to run the Monte Carlo transport code while respecting the criticality constraint. It does so in a manner that both improves the accuracy of the GP and finds the approximate global optimum. We demonstrate the performance of CBO with the design of a Thermal Epithermal eXperiment (TEX) for the criticality safety validation of nuclear waste models of the Hanford Tank Farm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Quantum computing based hybrid solution strategies for large-scale discrete-continuous optimization problems

Quantum computing (QC) has gained popularity due to its unique capabilities that are quite different from that of classical computers in terms of speed and methods of operations. This paper proposes hybrid models and methods that effectively leverage the complementary strengths of deterministic algorithms and QC techniques to overcome combinatorial complexity for solving large-scale mixed-integer programming problems. Four applications, namely the molecular conformation problem, job-shop scheduling problem, manufacturing cell formation problem, and the vehicle routing problem, are specifically addressed. Large-scale instances of these application problems across multiple scales ranging from molecular design to logistics optimization are computationally challenging for deterministic optimization algorithms on classical computers. To address the computational challenges, hybrid QC-based algorithms are proposed and extensive computational experimental results are presented to demonstrate their applicability and efficiency. The proposed QC-based solution strategies enjoy high computational efficiency in terms of solution quality and computation time, by utilizing the unique features of both classical and quantum computers.

97 MATHEMATICS AND COMPUTING↗

Predicting multiphase flow and tracer transport for an underground chemical explosive test

Detecting radionuclide gas seepage from clandestine underground nuclear tests is central to nonproliferation explosion monitoring research. Yet, early-time (<6 day) gas transport driven by the explosive pressure wave remains poorly constrained due to scarcity of field data. We simulate multi-phase gas transport in the vadose zone using pre-shot data from a recent chemical explosion in P-Tunnel at the Nevada National Security Site, USA. Despite using a simplified 2D-radial model, predictions of tracer arrival matched observations within one order-of-magnitude. Our results show how transient blast forcing rapidly mobilizes gases from the cavity into surrounding rock – critical for optimizing sensor placement and test planning. This unique integration of field data and modeling represents a significant improvement in our ability to predict gas migration from underground explosions. More broadly, it offers insights into the coupled dynamics of pressure waves and contaminant transport in the vadose zone, with implications for monitoring and hazard assessment.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Clean Energy Generation Targets on the Portfolio of Electric Grid Generation Technologies

A least-cost generation and transmission expansion planning model is used to optimize the U.S. generation portfolio in 2030 under a range of Clean Energy Generation Target (CEGT) policy goals. As reference cases for comparison, the model is used to optimize the generation portfolio for the future electric grid with and without the Investment and Production Tax Credits (ITC and PTC). Next, the model is used to optimize the generation portfolio with a CEGT ranging from 10% to 70%. The results show that due to the ITC and PTC extensions by the 2022 Inflation Reduction Act, there is little additional investment in renewable energy generation assets at low CEGT levels. Significant additional installations of both renewable energy generation and energy storage systems – both batteries and pumped storage hydro – become important at CEGT levels above approximately 30%.

Aldeman, Matthew↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement of Deformation Heterogeneity During Shale Swelling Using Digital Image Correlation

Abstract Rock-fluid interactions in shale formations are one of the main sources of wellbore instability issues and inadequate stimulation performance. For better planning of fracturing operations and optimizing production from these reservoirs, it is important to understand the mechanisms behind these interactions. These issues are especially prevalent in clay-rich shales, such as Tuscaloosa Marine Shale, which is the subject of this study. Conventional techniques to quantify these shale-fluid interactions comprise of measuring swelling in powdered rock grains or measurement of deformation in the whole pieces of the core using a linear variable differential transformer and strain gages. However, the contribution from individual laminae to overall deformation cannot be evaluated using these methods. In this study, we developed an experimental setup to evaluate the spatial deformation in shale during interaction with water using digital image correlation (DIC). Deformation of two shale samples, with 34 wt% to 51 wt% clay content, was studied. White paint was used to generate a random speckle pattern on the specimen and then immersed in deionized water. The deformation process was captured using a digital camera and images were analyzed using DIC to quantify the deformation. The implementation of the DIC technique enables the visualization and quantification of spatial deformation in the specimen during interacting with water. The results show the localization of large strains in select laminations. The results provide a better understanding of shale deformation when interacting with water in comparison to traditional measurements that can provide only an average strain value.

Energy & Fuels↗

Current Trends in Gamma Radiation Detection for Radiological Emergency Response

Passive and active detection of gamma rays from shielded radioactive materials, including special nuclear materials, is an important task for any radiological emergency response organization. This article reports on the current trends and status of gamma radiation detection objectives and measurement techniques as applied to nonproliferation and radiological emergencies. In recent years, since the establishment of the Domestic Nuclear Detection Office by the Department of Homeland Security, a tremendous amount of progress has been made in detection materials (scintillators, semiconductors), imaging techniques (Compton imaging, use of active masking and hybrid imaging), data acquisition systems with digital signal processing, field programmable gate arrays and embedded isotopic analysis software (viz. gamma detector response and analysis software [GADRAS]1), fast template matching, and data fusion (merging radiological data with geo-referenced maps, digital imagery to provide better situational awareness). In this stride to progress, a significant amount of interdisciplinary research and development has taken place–techniques and spin-offs from medical science (such as x-ray radiography and tomography), materials engineering (systematic planned studies on scintillators to optimize several qualities of a good scintillator, nanoparticle applications, quantum dots, and photonic crystals, just to name a few). No trend analysis of radiation detection systems would be complete without mentioning the unprecedented strategic position taken by the National Nuclear Security Administration (NNSA) to deter, detect, and interdict illicit trafficking in nuclear and other radioactive materials across international borders and through the global maritime transportation–the so-called second line of defense.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-522: A Multi-Isocenter VMAT Technique for Cranio-Spinal Irradiation

Purpose: Develop a matching VMAT field technique and investigate planning feasibility for treating the entire central nervous system (CNS) using Cranio-Spinal Irradiation (CSI) . Methods: Two patients diagnosed with acute myeloid leukemia (AML) presented with CNS involvement, received CSI, and were included in this study. The patients were treated with the traditional CSI technique: prone position, opposing lateral brain fields, two posterior fields (upper and lower spine), and 5mm junction shifts to improve dose uniformity. The patients were retrospectively re-planned using volumetric arc therapy (VMAT). The spine and brain were contoured to create the clinical target volume (CTV) as well as normal tissues including kidneys, lung and heart for optimization. Three isocenters were used for planning: brain, upper and lower spine. The beams were allowed to overlap by approximately 10cm. Entire 360 degree rotations were used for the brain fields and posterior 120 degree arcs were used for the spine fields. The dosimetric coverage of the target between the VMAT and traditional plans was compared, as well as the dose to normal tissues. Results: Both VMAT plans achieved improved dose uniformity in the CTV (standard deviation < 2%), and reduced hot spots (<110%). Dose to the heart was reduced, with the V10 being 12.7% and 28.2%, compared to 44.6% and 50.2%, respectively, for the traditional plan. Dose to the total lung V5 increased for the VMAT plans for both patients (21.6% and 27.8% compared to 12% and 13% respectively). The results for the kidneys were mixed with the mean dose increasing for one patient and decreasing for the other . Conclusion: The efficacy of planning CSI treatments using a matching VMAT technique was demonstrated. The developed technique has the potential to improve dose uniformity to the target while at the same time reduce the risk of under or over dosing the spine.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-04: Feature Selection and Clustering Optimization for Pseudo-CT Generation in MR-Based Attenuation Correction and Radiation Therapy Planning

Purpose: Accurate and robust photon attenuation derived from MR is essential for PET/MR and MR-based radiation treatment planning applications. Although the fuzzy C-means (FCM) algorithm has been applied for pseudo-CT generation, the input feature combination and the number of clusters have not been optimized. This study aims to optimize both for clinically practical pseudo-CT generation. Methods: Nine volunteers were recruited. A 190-second, single-acquisition UTE-mDixon with 25% (angular) sampling and 3D radial readout was performed to acquire three primitive MR features at TEs of 0.1, 1.5, and 2.8 ms: the free-induction-decay (FID), the first and the second echo images. Three derived images, Dixon-fat and Dixon-water generated by two-point Dixon water/fat separation, and R2* (1/T2*) map, were also created. To identify informative inputs for generating a pseudo-CT image volume, all 63 combinations, choosing one to six of the feature images, were used as inputs to FCM for pseudo-CT generation. Further, the number of clusters was varied from four to seven to find the optimal approach. Mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R) of different combinations were compared for feature selection. Results: Among the 63 feature combinations, the four that resulted in the best MAPD and R were further compared along with the set containing all six features. The results suggested that R2* and Dixon-water are the most informative features. Further, including FID also improved the performance of pseudo-CT generation. Consequently, the set containing FID, Dixon-water, and R2* resulted in the most accurate, robust pseudo-CT when the number of cluster equals to five (5C). The clusters were interpreted as air, fat, bone, brain, and fluid. The six-cluster Result additionally included bone marrow. Conclusion: The results suggested that FID, Dixon-water, R2* are the most important features. The findings can be used to facilitate pseudo-CT generation for unsupervised clustering. Please note that the project was completed with partial funding from the Ohio Department of Development grant TECH 11-063 and a sponsored research agreement with Philips Healthcare that is managed by Case Western Reserve University. As noted in the affiliations, some of the authors are Philips employees.

60 APPLIED LIFE SCIENCES↗

SU-F-J-214: Dose Reduction by Spatially Optimized Image Quality Via Fluence Modulated Proton CT (FMpCT)

Purpose: Proton CT (pCT) is a promising imaging modality for reducing range uncertainty in image-guided proton therapy. Range uncertainties partially originate from X-ray CT number conversion to stopping power ratio (SPR) and are limiting the exploitation of the full potential of proton therapy. In this study we explore the concept of spatially dependent fluence modulated proton CT (FMpCT), for achieving optimal image quality in a clinical region of interest (ROI), while reducing significantly the imaging dose to the patient. Methods: The study was based on simulated ideal pCT using pencil beam (PB) scanning. A set of 250 MeV protons PBs was used to create 360 projections of a cylindrical water phantom and a head and neck cancer patient. The tomographic images were reconstructed using a filtered backprojection (FBP) as well as an iterative algorithm (ITR). Different fluence modulation levels were investigated and their impact on the image was quantified in terms of SPR accuracy as well as noise within and outside selected ROIs, as a function of imaging dose. The unmodulated image served as reference. Results: Both FBP reconstruction and ITR without total variation (TV) yielded image quality in the ROIs similar to the reference images, for modulation down to 0.1 of the full proton fluence. The average dose was reduced by 75% for the water phantom and by 40% for the patient. FMpCT does not improve the noise for ITR with TV and modulation 0.1. Conclusion: This is the first work proposing and investigating FMpCT for producing optimal image quality for treatment planning and image guidance, while simultaneously reducing imaging dose. Future work will address spatial resolution effects and the impact of FMpCT on the quality of proton treatment plans for a prototype pCT scanner capable of list mode data acquisition. Acknowledgement: DFG-MAP DFG - Munich-Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

SU-F-T-157: Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study

Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the difference in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH/NCI under CA U19 021239. CG was partially supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087).

60 APPLIED LIFE SCIENCES↗

NAMSA

In NAMSA, we introduce two main solutions to address the limitations of MSA-type algorithms for simulation of electron scattering/microscopy data: just-in-time compilation and work partitioning via MPI and GPU-to-GPU communication. First, the just-in-time (JIT) compilation strategy produces optimally tuned CUDA C++ kernels due to the data layout being perfectly known at runtime and compiled via calls from the Python interpreter. NAMSA automatically optimizes the 2-D FFT planning, and CUDA multi-streams scheduling/launching of probe simulations. With NAMSA, we can simulate electron scattering/microscopy on hundreds to thousands of GPUs, while removing the major limitations of memory and bandwidth from MSA.

Laanait, Nouamane↗