The large-area hybrid-optics RICH detector for the CLAS12 spectrometer

A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab to study the 3D nucleon structure in the yet poorly explored valence region by deep-inelastic scattering, and to perform precision measurements in hadronization and hadron spectroscopy. The adopted solution foresees a novel hybrid optics design based on an aerogel radiator, composite mirrors and densely packed and highly segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). Finally, the preliminary results of individual detector component tests and of the prototype performance at test-beams are reported here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

A large catalog of accurate distances to molecular clouds from PS1 photometry

Distance measurements to molecular clouds are important but are often made separately for each cloud of interest, employing very different data and techniques. We present a large, homogeneous catalog of distances to molecular clouds, most of which are of unprecedented accuracy. We determine distances using optical photometry of stars along lines of sight toward these clouds, obtained from PanSTARRS-1. We simultaneously infer the reddenings and distances to these stars, tracking the full probability distribution function using a technique presented in Green et al. We fit these star-by-star measurements using a simple dust screen model to find the distance to each cloud. We thus estimate the distances to almost all of the clouds in the Magnani et al. catalog, as well as many other well-studied clouds, including Orion, Perseus, Taurus, Cepheus, Polaris, California, and Monoceros R2, avoiding only the inner Galaxy. Typical statistical uncertainties in the distances are 5%, though the systematic uncertainty stemming from the quality of our stellar models is about 10%. The resulting catalog is the largest catalog of accurate, directly measured distances to molecular clouds. Our distance estimates are generally consistent with available distance estimates from the literature, though in some cases the literature estimates are off by a factor of more than two.

79 ASTRONOMY AND ASTROPHYSICS↗

Revealing a distortive polar order buried in the Fermi sea

Polar metals are challenging to identify spectroscopically because the fingerprints of electric polarization are often obscured by the presence of screening charges. Here, we unravel unambiguous signatures of a distortive polar order buried in the Fermi sea by probing the nonlinear optical response of materials driven by tailored terahertz fields. We apply this strategy to investigate the topological crystalline insulator Pb 1–x Sn x Te, tracking its soft phonon mode in the time domain and observing the occurrence of inversion symmetry breaking as a function of temperature. By combining measurements across the material’s phase diagram with ab initio calculations, we demonstrate the generality of our approach. These results highlight the potential of terahertz driving fields to reveal polar orders coexisting with itinerant electrons, thus opening additional avenues for material discovery.

74 ATOMIC AND MOLECULAR PHYSICS↗

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

Gravitational Harmonics from Shallow Resonant Orbits

Five gravitational constraints were derived for the GEOS 2 orbit (order 13, to 30th degree) whose principal resonant period is 6 days. The constraints explain the sinusoidal variation with argument of perigee of a lumped harmonic found from 41 6-day arcs of optical and laser data. The condition equations, derived from elementary perturbation theory are shown to account for almost all of the resonant information in the tracking data.

Wagner, C. A.↗

Correlation tracking for a Planetary Pointing and Tracking System

The Planetary Pointing and Tracking System (PPTS) is being developed to provide precision pointing for science platforms on future autonomous planetary spacecraft. The PPTS design approach using a CCD optical sensor for closed-loop control with respect to the target body, a gyro for inertial stabilization, and brushless dc torque motors for smooth and continuous platform articulation is essential for high resolution planetary imaging and automated science execution. An integral part of PPTS is the correlation tracker which has the potential to revolutionize autonomous guidance.

Assefi, T.↗

Using the radiative temperature difference at 3.7 and 11 microns to track dust outbreaks

The radiative temperature difference between 3.7 and 11 microns (Delta T) is investigated as a possible method for tracking dust outbreaks. Theoretical calculations indicate that the technique would be most sensitive to dust loading during the day when the Delta Ts are enhanced by reflection of 3.7-micron solar radiation. The feasibility of tracking dust outbreaks is demonstrated by comparing satellite observations with surface estimates of visibility. Theoretical calculations also demonstrate the potential of inferring the dust layer optical depth from these spectral measurements.

Ackerman, Steven A.↗

Simulating A Massive, Mobile Structure

Simulator replicates, kinematically and dynamically, mating of large, massive mobile structure with similarly large and massive fixed structure. Developed for testing berthing-and-latching mechanism. Fixed section holds active berthing-and-latching mechanism and its motor control system with optical encoder to maintain synchronization among four latches in mechanism. Tripodal load-cell network gathers data on load history of berthing operation, and infrared tracking system including light-emitting diodes produces data for position history.

Fantasia, Peter M.↗

Aerosol optical depth retrievals over the Konza Prairie

The aerosol optical depth over the Konza Prairie, near Manhattan, Kansas, was recorded at various locations by five separate teams. These measurements were made in support of the First ISLSCP Field Experiment (FIFE) and used to correct imagery from a variety of satellite and aircraft sensors for the effects of atmospheric scattering and absorption. The results from one instrument are reported here for 26 days in 1987 and for 7 in 1989. Daily averages span a range of 0.05 to 0.28 in the midvisible wavelengths. In addition, diurnal variations are noted in which the afternoon optical depths are greater than those of the morning by as much as 0.07. A comparison between instruments and processing techniques used to determine these aerosol optical depths is provided. The first comparisons are made using summer 1987 data. Differences of as much as 0.05 (midvisible) are observed. Although these data allow reasonable surface reflectance retrievals, they do not agree to within the performance limits typically associated with these types of instruments. With an accuracy goal of 0.02 a preseason calibration/comparison experiment was conducted at a mountain site prior to the final field campaign in 1989. Good calibration data were obtained, and good agreement (0.01, midvisible) was observed in the retrieved optical depth acquired over the Konza. By comparing data from the surface instruments at different locations, spatial inhomogeneities are determined. Then, data from the airborne tracking sunphotometer allow one to determine variations as a function of altitude. Finally, a technique is proposed for using the in situ data to establish an instrument calibration.

Bruegge, Carol J.↗

Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) baseline concept

There will be several state of the art spectrometers in operation on the NASA Polar Orbiting Platform (NPOP-1) as part of the Earth Observing System (EOS). The Moderate Resolution Imaging Spectrometer (MODIS) will consist of two imaging spectroradiometric instruments, one nadir viewing (MODIS-N) and the other tiltable (MODIS-T) for ocean observation and land bidirectional reflectance studies. The Moderate Resolution Imaging Spectrometer-Tilt (MODIS-T) instrument is presently being constructed for flight on the EOS. It is an imaging spectrometer utilizing a grating type, reflecting Schmidt optical design that must provide a 1.1 kilometer spatial resolution at nadir from a spacecraft altitude of 705 kilometers with a 1500 kilometer cross-track swath and a +/- 50 degree forward and aft tilt capability. The instrument is required to cover the wavelength range from 400 to 880 nanometers in approximately 15 nanometer steps with less than 2.3 percent instrument induced polarization. The absolute radiometric accuracy must be at least 5 percent over the full dynamic range of the instrument.

Magner, Thomas J.↗

TLRS-3 system upgrades

This presentation describes the upgrades to the Transportable Laser Ranging Systems serial number three (TLRS-3), and the impact that these upgrades will have on the TLRS-3 performance in the field. The four major areas of system upgrades are the HP-380 computer, the Optical Attenuation Mechanism (OAM), the upgraded spatial, spectral and temporal filtering for improved daylight ranging capability, and the software upgrade to enable the system to track the Etalon satellites. The TLRS-3 was returned to the Goddard Geophysical and Astronomical Observatory (GGAO) in December 1991 for system upgrades in preparation of the TOPEX/POSEIDON campaign scheduled to begin in the summer of 1992. Many system upgrades were incorporated into the system while interleaving planned facility maintenance making TLRS-3 a more versatile and more dependable laser ranging system. The TLRS-3 was initially baselined with the MOBLAS-7 via simultaneous satellite ranging on the LAGEOS, Ajisai, Starlette, and ERS-I satellites. During the upgrades and following completion of the system upgrades intercomparisons with the MOBLAS-7 were made to verify the integrity and accuracy of the system changes. Several other groups of personnel participated in the TLRS-3 upgrade and they are: the Survey Section, the Precision Measurement Equipment Laboratory, the Architectural and Engineering Services Department, the Precision Timing Section, and the station personnel at TLRS-3 and MOBLAS-7.

Eichinger, Richard↗

Validation of Ocean Color Remote Sensing Data using a Moored Databuoy

NASA's Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) aims to measure global ocean color from space to within 5% to provide insights into fundamental ocean processes. SeaWiFS must be backed by comprehensive calibration and validation programs if the mission is to achieve this. In situ measurements of normalized water-leaving radiance (L(sub wn)) made simultaneously with satellite measurements can complement on-orbit methods of tracking changes in the calibration of the satellite radiometer and allow end-to-end vicarious validation of the remotely-sensed data. A moored optical databuoy was developed at Plymouth Marine Laboratory, UK to measure L(sub wn) in the western English Channel. Tests indicate that the buoy is capable of measuring spectral incident irradiance with less than 10% error and water-leaving radiance with less than 20% error; these errors are reduced by averaging and show no bias. There were 24 match-ups with good quality SeaWiFS data at the buoy site during the ten months of deployment within the period May 1997 and September 1998. The differences between the buoy and SeaWiFS measurements of L(sub wn) were found to be variable and often large. The root-mean-square (RMS) differences varied from 102% at 412 nm to 50% at 555 nm. The RMS differences in measurements of L(sub wn) could be reduced to less than 18% by a combination of increasing the calibration coefficients of SeaWiFS by between 0.2 and 4.3% in the visible bands and by tuning the extrapolation of aerosol radiances from the near infrared to the visible wavelengths. These results imply that the monitoring of the absolute calibration of the SeaWiFS bands is imperfect and errors remain in the extrapolation of aerosol radiances for atmospheric correction.

Lavender, Samantha↗

Mobile Aerial Tracking and Imaging System (MATRIS) for Aeronautical Research

A mobile, rapidly deployable ground-based system to track and image targets of aeronautical interest has been developed. Targets include reentering reusable launch vehicles (RLVs) as well as atmospheric and transatmospheric vehicles. The optics were designed to image targets in the visible and infrared wavelengths. To minimize acquisition cost and development time, the system uses commercially available hardware and software where possible. The conception and initial funding of this system originated with a study of ground-based imaging of global aerothermal characteristics of RLV configurations. During that study NASA teamed with the Missile Defense Agency/Innovative Science and Technology Experimentation Facility (MDA/ISTEF) to test techniques and analysis on two Space Shuttle flights.

Banks, Daniel W.↗

NASA Tech Briefs, October 2011

Topics covered include: Laser Truss Sensor for Segmented Telescope Phasing; Qualifications of Bonding Process of Temperature Sensors to Deep-Space Missions; Optical Sensors for Monitoring Gamma and Neutron Radiation; Compliant Tactile Sensors; Cytometer on a Chip; Measuring Input Thresholds on an Existing Board; Scanning and Defocusing Properties of Microstrip Reflectarray Antennas; Cable Tester Box; Programmable Oscillator; Fault-Tolerant, Radiation-Hard DSP; Sub-Shot Noise Power Source for Microelectronics; Asynchronous Message Service Reference Implementation; Zero-Copy Objects System; Delay and Disruption Tolerant Networking MACHETE Model; Contact Graph Routing; Parallel Eclipse Project Checkout; Technique for Configuring an Actively Cooled Thermal Shield in a Flight System; Use of Additives to Improve Performance of Methyl Butyrate-Based Lithium-Ion Electrolytes; Li-Ion Cells Employing Electrolytes with Methyl Propionate and Ethyl Butyrate Co-Solvents; Improved Devices for Collecting Sweat for Chemical Analysis; Tissue Photolithography; Method for Impeding Degradation of Porous Silicon Structures; External Cooling Coupled to Reduced Extremity Pressure Device; A Zero-Gravity Cup for Drinking Beverages in Microgravity; Co-Flow Hollow Cathode Technology; Programmable Aperture with MEMS Microshutter Arrays; Polished Panel Optical Receiver for Simultaneous RF/Optical Telemetry with Large DSN Antennas; Adaptive System Modeling for Spacecraft Simulation; Lidar-Based Navigation Algorithm for Safe Lunar Landing; Tracking Object Existence From an Autonomous Patrol Vehicle; Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications; and Architecture for a 1-GHz Digital RADAR.

Source record↗

The Track Imaging Cerenkov Experiment

We describe a dedicated cosmic-ray telescope that explores a new method for detecting Cerenkov radiation from high-energy primary cosmic rays and the large particle air shower they induce upon entering the atmosphere. Using a camera comprising 16 multi-anode photomultiplier tubes for a total of 256 pixels, the Track Imaging Cerenkov Experiment (TrICE) resolves substructures in particle air showers with 0.086deg resolution. Cerenkov radiation is imaged using a novel two-part optical system in which a Fresnel lens provides a wide-field optical trigger and a mirror system collects delayed light with four times the magnification. TrICE records well-resolved cosmic-ray air showers at rates ranging between 0.01-0.1 Hz.

Wissel, S. A.↗

Normal State Charge Dynamics of Fe1.06Te0.88S0.14 Superconductor Probed with Infrared Spectroscopy

We have used optical spectroscopy to probe the normal state electrodynamic response of Fe{sub 1.06}Te{sub 0.88}S{sub 0.14}, a member of the 11 family of iron-based superconductors with T{sub c} = 8 K. Measurements have been conducted over a wide frequency range (50-50,000 cm{sup -1}) at selected temperatures between 10 and 300 K. At low temperatures the material behaves as an 'incoherent metal: a Drude-type peak is absent from the optical conductivity and all optical functions reveal that quasiparticles are not well defined down to the lowest measured temperature. We introduce 'generalized spectral weight' analysis and use it to track temperature induced redistribution of spectral weight. Our results, combined with previous reports, indicate that the 11 family of iron-based superconductors might be different from other families.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Airborne tracking sunphotometer apparatus and system

An airborne tracking Sun photometer apparatus has a rotatable dome. An azimuth drive motor is connected to rotate the dome. The dome has an equatorial slot. A cylindrical housing is pivotally mounted inside the dome at the equatorial slot. A photometer is mounted in the housing to move in the equatorial slot as the housing pivots. The photometer has an end facing from the slot with an optical flat transparent window. An elevation drive motor is connected to pivot the cylindrical housing. The rotatable dome is mounted in the bulkhead of an aircraft to extend from the interior of the aircraft. A Sun sensor causes the photometer to track the Sun automatically. Alternatively, the photometer may be oriented manually or by computer.

Matsumoto, Yutaka↗