Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Design Evolution of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) and Lessons Learned

The design of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) continues to evolve as each design cycle is analyzed. In 2012, two Hubble sized (2.4 m diameter) telescopes were donated to NASA from elsewhere in the Federal Government. NASA began investigating potential uses for these telescopes and identified WFIRST as a mission to benefit from these assets. With an updated, deeper, and sharper field of view than previous design iterations with a smaller telescope, the optical designs of the WFIRST instruments were updated and the mechanical and thermal designs evolved around the new optical layout. Beginning with Design Cycle 3, significant analysis efforts yielded a design and model that could be evaluated for Structural-Thermal-Optical-Performance (STOP) purposes for the Wide Field Imager (WFI) and provided the basis for evaluating the high level observatory requirements. Development of the Cycle 3 thermal model provided some valuable analysis lessons learned and established best practices for future design cycles. However, the Cycle 3 design did include some major liens and evolving requirements which were addressed in the Cycle 4 Design. Some of the design changes are driven by requirements changes, while others are optimizations or solutions to liens from previous cycles. Again in Cycle 4, STOP analysis was performed and further insights into the overall design were gained leading to the Cycle 5 design effort currently underway. This paper seeks to capture the thermal design evolution, with focus on major design drivers, key decisions and their rationale, and lessons learned as the design evolved.

Thermal Design↗

Design Evolution of the Wide Field Infrared Survey Telescope Using Astrophysics Focused Telescope Assets (WFIRST-AFTA) and Lessons Learned

The design of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) continues to evolve as each design cycle is analyzed. In 2012, two Hubble sized (2.4 m diameter) telescopes were donated to NASA from elsewhere in the Federal Government. NASA began investigating potential uses for these telescopes and identified WFIRST as a mission to benefit from these assets. With an updated, deeper, and sharper field of view than previous design iterations with a smaller telescope, the optical designs of the WFIRST instruments were updated and the mechanical and thermal designs evolved around the new optical layout. Beginning with Design Cycle 3, significant analysis efforts yielded a design and model that could be evaluated for Structural-Thermal-Optical-Performance (STOP) purposes for the Wide Field Imager (WFI) and provided the basis for evaluating the high level observatory requirements. Development of the Cycle 3 thermal model provided some valuable analysis lessons learned and established best practices for future design cycles. However, the Cycle 3 design did include some major liens and evolving requirements which were addressed in the Cycle 4 Design. Some of the design changes are driven by requirements changes, while others are optimizations or solutions to liens from previous cycles. Again in Cycle 4, STOP analysis was performed and further insights into the overall design were gained leading to the Cycle 5 design effort currently underway. This paper seeks to capture the thermal design evolution, with focus on major design drivers, key decisions and their rationale, and lessons learned as the design evolved.

WFIRST↗

Cryogenic Optical Position Encoders for Mechanisms in the JWST Optical Telescope Element Simulator (OSIM)

The JWST Optical Telescope Element Simulator (OSIM) is a configurable, cryogenic, optical stimulus for high fidelity ground characterization and calibration of JWST's flight instruments. OSIM and its associated Beam Image Analyzer (BIA) contain several ultra-precise, cryogenic mechanisms that enable OSIM to project point sources into the instruments according to the same optical prescription as the flight telescope images stars - correct in focal surface position and chief ray angle. OSIM's and BIA's fifteen axes of mechanisms navigate according to redundant, cryogenic, absolute, optical encoders - 32 in all operating at or below 100 K. OSIM's encoder subsystem, the engineering challenges met in its development, and the encoders' sub-micron and sub-arcsecond performance are discussed.

Leviton, Douglas B.↗

Optical Element Design for the Retrofit of the World's First Concentrator Photovoltaic (CPV) Power Plant

The world's oldest, and still functional, Concentrator Photovoltaic (CPV) power plant originally rated at 350 kW, and is situated 50 km from Riyadh, Saudi Arabia. There are ongoing efforts to retrofit the modules with new secondary optics and triple-junction cell devices. The paper characterizes the initial optical train, whose design is non-conventional in its use of a two-area primary Fresnel lens. The first generation of a retrofit receiver package is described. Challenges beyond the optical design are encountered, including tracking and structural mechanics.

14 SOLAR ENERGY↗

Fabrication of MgF2 and LiF windows for the Hubble Space Telescope Imaging Spectrograph

Two prototype test windows (MgF2 and LiF) to be used on the 75-mm UV MAMA detector tubes for the Hubble Space Telescope Imaging Spectrograph are described. The spatial and optical constraints of this instrument dictate that the thickness of the window materials be no greater than 2-3 mm to achieve a minimum 50-percent transmission at hydrogen Lyman alpha (121.6 nm), and that the window must be domed to minimize optical aberrations and provide structural strength. The detector window has an input diameter of about 100 mm with a radius-of-curvature of 70 mm. The manufacturing processes involved in the fabrication of these windows is discussed, as well as test programs (optical and structural) to be performed at Goddard Space Flight Center.

Gormley, Daphne↗

Loading, electromyograph, and motion during exercise

A system is being developed to gather kineto-dynamic data for a study to determine the load vectors applied to bone during exercise on equipment similar to that used in space. This information will quantify bone loading for exercise countermeasures development. Decreased muscle loading and external loading of bone during weightlessness results in cancellous bone loss of 1 percent per month in the lower extremities and 2 percent per month in the calcaneous. It is hypothesized that loading bone appropriately during exercise may prevent the bone loss. The system consists of an ergometer instrumented to provide position of the pedal (foot), pedaling forces on the foot (on the sagittal plane), and force on the seat. Accelerometers attached to the limbs will provide acceleration. These data will be used as input to an analytical model of the limb to determine forces on the bones and on groups of muscles. EMG signals from activity in the muscles will also be used in conjunction with the equations of mechanics of motion to be able to discern forces exerted by specific muscles. The tasks to be carried out include: design of various mechanical components to mount transducers, specification of mechanical components, specification of position transducers, development of a scheme to control the data acquisition instruments (TEAC recorder and optical encoder board), development of a dynamic model of the limbs in motion, and development of an overall scheme for data collection analysis and presentation. At the present time, all the hardware components of the system are operational, except for a computer board to gather position data from the pedals and crank. This board, however, may be put to use by anyone with background in computer based instrumentation. The software components are not all done. Software to transfer data recorded from the EMG measurements is operational, software to drive the optical encoder card is mostly done. The equations to model the kinematics and dynamics of motion of the limbs have been developed, but they have not yet been implemented in software. Aside from the development of the hardware and software components of the system, the methodology to use accelerometers and encoders and the formulation of the appropriate equations are an important contribution to the area of biomechanics, particularly in space applications.

Figueroa, Fernando↗

Utilization of optical sensors for phasor measurement units

With the help of GPS signals for synchronization, increasingly ubiquitous phasor measurement units (PMUs) provide power grid operators unprecedented system monitoring and control opportunities. However, the performance of PMUs is limited by the inherent deficiencies in traditional transformers. To address these issues, an optical sensor is used in PMU for signal acquisition to replace the traditional transformers. This is the first time the utilization of an optical sensor in PMUs has ever been reported. The accuracy of frequency, angle, and amplitude are evaluated via experiments. Lastly, the optical sensor based PMU can achieve the accuracy of 9.03 × 10 –4 Hz for frequency, 6.38 × 10 –3 rad for angle and 6.73 × 10 –2 V for amplitude with real power grid signal, demonstrating the practicability of optical sensors in future PMUs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Straylight comparison of SIRTF designs with different aperture stop locations

The APART/PADE program is used to examine whether the SIRTF aperture stop can be moved back to the primary mirror without jeopardizing the requirement for natural background-limited observations. The straylight performance of the baseline design, which has the aperture stop at the secondary mirror, is compared to that of a revised design with the stop at the primary mirror. Both designs include reimaging optics and a LYOT stop, as well as a chopping secondary mirror. The straylight due to off-axis sources and telescope thermal emission is investigated at 50 and 550 microns. It is found that in SIRTF, where every instrument will include reimaging optics and a LYOT stop, the aperture stop may be moved to the primary mirror with modest degradation of the straylight performance.

Dinger, Ann S.↗

Detection of single atoms and buried defects in three dimensions by aberration-corrected electron microscope with 0.5-A information limit.

The ability of electron microscopes to analyze all the atoms in individual nanostructures is limited by lens aberrations. However, recent advances in aberration-correcting electron optics have led to greatly enhanced instrument performance and new techniques of electron microscopy. The development of an ultrastable electron microscope with aberration-correcting optics and a monochromated high-brightness source has significantly improved instrument resolution and contrast. In the present work, we report information transfer beyond 50 pm and show images of single gold atoms with a signal-to-noise ratio as large as 10. The instrument's new capabilities were exploited to detect a buried {Sigma}3 {l_brace}112{r_brace} grain boundary and observe the dynamic arrangements of single atoms and atom pairs with sub-angstrom resolution. These results mark an important step toward meeting the challenge of determining the three-dimensional atomic-scale structure of nanomaterials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spectral Properties of Dust on Asteroid (101955) Bennu with the OSIRIS-REx Visible and Infrared Spectrometer (OVIRS)

The Origins, Spectral Interpretation, Resource Identification, Security-Regolith Explorer (OSIRIS-REx) spacecraft successfully collected a sample of regolith from asteroid (101955) Bennu on October 20, 2020[1]. The Touch-and-Go (TAG) spacecraft maneuver used to collect the sample mobilized material, including very fine particles (dust),from up to ~1m in depth and ~10m in diameter from the point of contact with the asteroid [1,2].TAG created a dust plume that intercepted the spacecraft and accumulated on the instruments. As a result, all instruments show degradation in optical throughput, with the degree of degradation depending on their aperture size, orientation, and position on the spacecraft [1]. In this study, we analyzed OSIRIS-REx Visible and Infrared Spectrometer (OVIRS) from before and after TAG to assess the dust on the instrument with implications for Bennu’s dust composition and scattering properties, and future visible–near-infrared (VNIR)spectral observations with the OSIRIS-REx spacecraft. OVIRS is a point spectrometer that measures reflected light at VNIR wavelengths from 0.4 to 4.3 μm with a 4 mrad circular field of view(FOV) [3]. Previous observations with OVIRS revealed widespread hydrated minerals and carbon-bearing materials on Bennu [4,5]. A ~3 μm absorption feature is observed globally in OVIRS spectra, with a band position and depth that is consistent with Mg/Fe phyllosilicates and suggests a similar degree of aqueous alteration to that experienced by some carbonaceous chondrite meteorites[4,6]. A series of weak (<5%) VNIR spectral features, potentially associated with hydrated phyllosilicates and iron oxides, are also found in OVIRS spectra (Fig. 1), though not typically observed in meteorite spectra [7]. OSIRIS-REx Thermal Emission Spectrometer (OTES) spectra are consistent with a very thin accumulation (a few to ~ten microns) of fine particles (<~65–100 microns in size)across the surface of Bennu, and particularly on the roughest boulders, an interpretation that is supported by the dust plume seen during TAG [1,8]. An analysis of TAG contamination on the OTES optics revealed a 15% decrease in throughput, and OTES observations of space with and without that contamination allow a recreation of the thermal infrared spectrum [1]. The spectrum of the contamination lacks volume scattering features and exhibits a stronger Mg-OH absorption (~16.5 μm) than average Bennu, suggesting a Mg-rich phyllosilicate composition [1,6]. Here we present the first compositional analysis of Bennu dust at VNIR wavelengths by analyzing the contaminant on OVIRS.

H H Kaplan↗

DEVELOPMENT OF AN OPTICAL SYSTEM FOR HIGH-SPEED, SMALL-SCALE VELOCITY MEASUREMENTS

An optical system was developed to allow the accurate focussing and alignment of small samples for velocity analysis with streak photography Even at low magnifications, a narrow streak slit means that any vibration or instability in the system greatly reduces the accuracy of the velocity measurements achieved. The optical system was designed to reduce the effects of such vibration. A spatial mount and rotation stage were modified to allow three spatial axis and rotational freedom of a custom-made sample mount. Markers within the sample mount were used to achieve precise alignment of the sample with the optical axis of the streak camera.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scatter from optical components; Proceedings of the Meeting, San Diego, CA, Aug. 8-10, 1989

Various papers on scatter from optical components are presented. Individual topics addressed include: BRDF of SiC and Al foam compared to black paint at 3.39 microns, characterization of optical baffle materials, bidirectional transmittance distribution function of several IR materials at 3.39 microns, thermal cycling effects on the BRDF of beryllium mirrors, BTDV of ZnSe with multilayer coatings at 3.39 microns, scattering from contaminated surfaces, cleanliness correlation by BRDF and PFO instruments, contamination effects on optical surfaces, means of eliminating the effects of particulate contamination on scatter measurements of superfine optical surfaces, vacuum BRDF measurement of cryogenic optical surfaces, Monte Carlo simulation of contaminant transport to and deposition on complex spacecraft surfaces, surface particle observation and BRDF predictions, satellite material contaminant optical properties, dark field photographic techniques for documenting optical surface contamination, design of a laboratory study of contaminant film darkening in space, contamination monitoring approaches for EUV space optics.

Stover, John C.↗

Design and characterization of a low cost CubeSat multi-band optical receiver to map water ice on the lunar surface for the Lunar Flashlight mission

Lunar Flashlight is an innovative NASA CubeSat mission dedicated to mapping water ice in the permanently shadowed regions of the Moon, which may act as cold traps for volatiles. To this end, a multi-band reflectometer will be sent to orbit the Moon. This instrument consists of an optical receiver aligned with four lasers, each of which emits sequentially at a different wavelength in the near-infrared between 1 μm and 2 μm. The receiver measures the laser light reflected from the lunar surface; continuum/absorption band ratios are then analyzed to quantify water ice in the illuminated spot. Here, we present the current state of the optical receiver design. To optimize the optical signal-to-noise ratio, we have designed the receiver so as to maximize the laser signal collected, while minimizing the stray light reaching the detector from solar-illuminated areas of the lunar surface outside the field-of-view, taking into account the complex lunar topography. Characterization plans are also discussed. This highly mass- and volume-constrained mission will demonstrate several firsts, including being one of the first CubeSats performing science measurements beyond low Earth orbit.

Sellar, Glenn R.↗

Enhancement and suppression of opto-acoustic parametric interactions using optical feedback

A three mode opto-acoustic parametric amplifier (OAPA) is created when two orthogonal optical modes in a high finesse optical cavity are coupled via an acoustic mode of the cavity mirror. Such interactions are predicted to occur in advanced long baseline gravitational wave detectors. They can have high positive gain, which leads to strong parametric instability. Here we show that an optical feedback scheme can enhance or suppress the parametric gain of an OAPA, allowing exploration of three-mode parametric interactions, especially in cavity systems that have insufficient optical power to achieve spontaneous instability. We derive analytical equations and show that optical feedback is capable of controlling predicted instabilities in advanced gravitational wave detectors within a time scale of 13approx10 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mo/Si multilayer-coated amplitude-division beam splitters for XUV radiation sources

Amplitude-division beam splitters for XUV radiation sources have been developed and extensively characterized. Mo/Si multilayer coatings were deposited on 50 nm-thick SiN membranes. By changing the multilayer structure (periodicity, number of bilayers, etc.) the intensity of the reflected and transmitted beams were optimized for selected incident radiation parameters (wavelength, incident angle). The developed optical elements were characterized by means of XUV reflectometry and transmission measurements, atomic force microscopy and optical interferometry. Special attention was paid to the spatial homogeneity of the optical response and reflected beam wavefront distortions. Here the results of the characterization are presented and improvements required for advanced applications at XUV free-electron lasers are identified. A flatness as low as 4 nm r.m.s. on 3 × 3 mm beam splitters and 22 nm r.m.s. on 10 × 10 mm beam splitters has been obtained. The high-spatial-frequency surface roughness was about 0.7–1 nm r.m.s. The middle-spatial-frequency roughness was in the range 0.2–0.8 nm r.m.s. The reflection and transmission of the beam splitters were found to be very homogeneous, with a deviation of less than 2% across the full optical element.

47 OTHER INSTRUMENTATION↗

Compact, All-PM Fiber Integrated and Alignment-Free Ultrafast Yb:Fiber NALM Laser With Sub-Femtosecond Timing Jitter

We report a simple and compact design of a dispersion compensated mode-locked Yb:fiber oscillator based on a nonlinear amplifying loop mirror (NALM). The fully polarization maintaining (PM) fiber integrated laser features a chirped fiber Bragg grating (CFBG) for dispersion compensation and a fiber integrated compact non-reciprocal phase bias device, which is alignment-free. The main design parameters were determined by numerically simulating the pulse evolution in the oscillator and by analyzing their impact on the laser performance. Experimentally, we achieved an 88 fs compressed pulse duration with sub-fs timing jitter at 54 MHz repetition rate and 51 mW of output power with 5.5×10 -5 [20 Hz, 1 MHz] integrated relative intensity noise (RIN). Furthermore, we demonstrate tight phase-locking of the laser's carrier-envelope offset frequency ( fceo ) to a stable radio frequency (RF) reference and of one frequency comb tooth to a stable optical reference at 291 THz.

47 OTHER INSTRUMENTATION↗

The Chandra X-Ray Observatory-Overview and Status

The Chandra X-Ray Observatory was launched early in the morning of 1999, July 23 by the Space Shuttle Columbia. The Shuttle launch was only the first step in placing NASA's latest great observatory into orbit. After release from the cargo bay, the Inertial Upper Stage performed two firings and separated from the observatory as planned. Finally, after five firings of Chandra's own Integral Propulsion System - the last of which took place 15 days after the initial launch - the observatory was placed in its highly elliptical orbit of 140,000 km apogee and 10,000 km perigee. After Observatory activation, the first x-rays focussed by the telescope were observed on 1999, August 12. Beginning with this initial observation one could conclude that the telescope had survived the launch environment and was operating as expected. The month following the opening of the sunshade door was spent adjusting the focus for each set of instrument configurations, determining the optical axis, calibrating the star camera, establishing the relative response functions, determining the energy scale(s), and performing a series of "publicity" images. Each observation proved to be far more revealing than was expected. Preliminary results will be presented and the status of the instrumentation on the observatory will be discussed.

Weisskopf, Martin C.↗

The Chandra X-Ray Observatory Overview

The Chandra X-Ray Observatory was launched early in the morning of July 23, 1999 by the Space Shuttle Columbia. The Shuttle launch was only the first step in placing NASA's latest great observatory into orbit. After release from the cargo bay, the Inertial Upper Stage performed two firings and separated from the observatory as planned. Finally, after five firings of Chandra's own Integral Propulsion System - the last of which took place 15 days after the initial launch - the observatory was placed in its highly elliptical orbit of 140,000 km apogee and 10,000 km perigee. After Observatory activation, the first x-rays focussed by the telescope were observed on August 12, 1999. Beginning with this initial observation one could conclude that the telescope had survived the launch environment and was operating as expected. The month following the opening of the sunshade door was spent adjusting the focus for each set of instrument configurations, determining the optical axis, calibrating the star camera, establishing the relative response functions, determining the energy scale(s), and performing a series of "publicity" images. Each observation proved to be far more revealing than was expected. Preliminary results will be presented and the status of the instrumentation on the observatory will be discussed.

Weisskopf, Martin C.↗