Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Rational design of small molecules that modulate the transcriptional function of the response regulator PhoP

Highlights: • Development of a successful computational strategy to identify both inhibitors as well as enhancers of the PhoP dimerization. • Identification of the first 3 different classes compounds that have experimentally validated activity. • These compounds are the first druglike compounds targeting the PhoP dimerization. • The most potent molecule has an EC50 value 2.0 μM. The response regulator PhoP, which is part of the PhoP/PhoQ two-component system, regulates the expression of multiple genes involved in controlling virulence in Salmonella enterica serovar Typhimurium and other species of Gram-negative bacteria. Modulating the phosphorylation-mediated dimerization in the receiver domain may interfere with the transcriptional function of PhoP. In this study, we analyzed the therapeutic potential of the PhoP receiver domain by exploring it as a potential target for drug design. The structural information was then applied to identify the first hit compounds from commercial chemical libraries by combining pharmacophore modelling and docking methods with a GFP (Green Fluorescent Protein)-based promoter-fusion bioassay. In total, one hundred and forty compounds were selected, purchased, and tested for biological activity. Several novel scaffolds showed acceptable potency to modulate the transcriptional function of PhoP, either by enhancing or inhibiting the expression of PhoP-dependent genes. These compounds may be used as the starting point for developing modulators that target the protein-protein interface of the PhoP protein as an alternative strategy against antibiotic resistance.

60 APPLIED LIFE SCIENCES↗

Biogenic triamine and tetraamine activate core catalytic ability of Tetrahymena group I ribozyme in the absence of its large activator module

Highlights: • Biogenic triamine and tetraamine efficiently activated the ∆P5 ribozyme. • Spermine (tetraamine) modestly inhibited the full-length Tetrahymena ribozyme. • Polyamines are promising small molecule modulators to activate and possibly inhibit the core catalytic ability of group I ribozymes. Group I intron ribozymes share common core elements that form a three-dimensional structure responsible for their catalytic activity. This core structure is unstable without assistance from additional factors that stabilize its tertiary structure. We examined biogenic triamine and tetraamine and also their fragments for their abilities to stabilize a structurally unstable group I ribozyme, ΔP5 ribozyme, derived from the Tetrahymena group I intron ribozyme by deleting its large activator module. Biogenic triamine (spermidine) and tetraamine (spermine) efficiently activated the ΔP5 ribozyme under conditions where the ribozyme was virtually inactive. These observations suggested that polyamines are promising small molecule modulators to activate and possibly inhibit the core catalytic ability of group I ribozymes.

60 APPLIED LIFE SCIENCES↗

Intra-catalyst CH 4 oxidation pathways on a Pd/Al 2 O 3 /CeZrO x -based commercial catalyst and implications on NO x conversion profiles for a natural gas vehicle exhaust under lambda modulation

The performance of a three-way catalyst (TWC) in natural gas-powered vehicles is enhanced by periodic changes in air-to-fuel ratio (λ-modulation). The reaction networks and sequences inside the catalyst that facilitate such enhanced performance have not been extensively investigated. Here, this work applied intra-catalyst measurements (SpaciMS) to analyze the transient spatiotemporal gas concentrations inside a Pd-based TWC to establish relationships between CH 4 , NO x , CO and H 2 conversion pathways. Steam reforming and partial oxidation were revealed to be the main CH 4 conversion routes. The cyclic rich-lean conditions combined with the oxygen storage capacity (OSC) of the TWC generate reduced and oxidized zones that are constantly moving within the catalyst, changing the dominant chemical reactions occurring on the surface. In the reduced zones, OSC is depleted while CH 4 is converted through steam reforming and NO x is converted through reactions with H 2 , CO, and other surface-bound reducing fragments formed by CH 4 conversion. In the oxidized zones, OSC is replenished, CH 4 is converted by partial oxidation, and H 2 , CO, and NH 3 are oxidized. The length of lean-rich phases impacts the catalyst performance significantly; too short or too long of a rich or lean phase can lower the overall conversion of reactive species. An inhibition of CH 4 conversion was observed during the rich phase possibly due to CO-poisoning of active sites. The intra-catalyst measurements revealed that the catalyst consists of three distinct reaction zones and their lengths vary with modulation conditions. Various modulation frequencies, amplitudes, λ-centers, and temperatures were investigated which allowed an understanding of how these parameters affect the reaction zones and catalyst utilization. Understandings from this work can enable adaptive λ-control strategies to optimize the overall TWC performance over a range of vehicle operating conditions.

Lean-Rich cycling↗

The MOOSE fluid properties module

The Fluid Properties module within the Multiphysics Object-Oriented Simulation Environment (MOOSE) is used to compute fluid properties for numerous applications, ranging from nuclear reactor thermal hydraulics to geothermal energy. Those applications drove the development of the module to enable numerous different fluid equations of states, property lookups with primitive and conserved flow variable to cater to pressure and density-driven solvers, and an object-oriented design facilitating expansion and maintenance. Each fluid property is implemented in its own class but inherits capabilities such as automatic differentiation, automated out-of-bounds handling or variable conversion capabilities. Here, this paper presents the module, its design, its user and developer interface, its content in terms of fluids and properties, and several of its applications showing its major role in the MOOSE simulation ecosystem.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancements in conventional and 3D printed feed spacers in membrane modules

Plate & frame and spiral-wound modules are used for gas separation, pervaporation, reverse osmosis, nanofiltration, ultrafiltration, microfiltration, electro-dialysis, electro-deionization, membrane distillation and forward osmosis membrane processes. Feed channel spacers are an integral part of both module types – providing mechanical support for a cross-flow channel through the module and, in most cases, promoting mixing to enhance mass transfer to reduce concentration polarization and fouling. However, enhanced mass transfer comes at a cost of increased hydraulic pressure losses and stagnant zones wherever a spacer filament touches a membrane surface. Further, these stagnant zones exacerbate membrane fouling and make cleaning more difficult. Efforts to improve feed spacer performance largely focus on adjusting the chemistry or geometry of the spacer to mitigate these challenges. Additive manufacturing (i.e. 3D printing) offers new degrees of freedom in feed spacer design and production, which opens up a new area of research in membrane technology. This review critically assesses the peer-reviewed literature on conventional net- or mesh-style feed spacers in addition to various novel spacer geometries and chemistries produced via 3D printing. We further review and evaluate conventional spacer manufacturing methods and discuss advantages and disadvantages of 3D printed spacers.

3D printing↗

Features of mechanical behavior of EV battery modules under high deformation rate

Here, we observe changes in material behavior of electric vehicle (EV) Li-ion battery cell modules when the loading speed increases from quasi-static to high speed (close to 1 m/s). A series of out-of-plane indentation experiments were performed on stacks of pouch cells placed in the specially designed enclosure to represent conditions in battery modules. Over one hundred of large format automotive pouch cells were tested under displacement rates differing by orders of magnitude. The details of internal failure were studied by X-ray tomography (XCT). We determine a shift in the force–displacement response from a parabolic behavior characteristic of particulate materials under compression to the response normal of fully dense materials with yield point. This shift is associated with dynamic effects in active materials which result in deep propagation of damage into the battery module, despite the fact that the internal short circuit is triggered when the displacement of the indenter is one half of that under the slow displacement rate.

25 ENERGY STORAGE↗

Advanced diagnostics to evaluate heterogeneity in lithium-ion battery modules

Battery packs for electric and stationary applications experience varied operating conditions, including abuse—e.g., fast charging, overcharging, thermal, vibration, shock, etc.—throughout their lifetimes. Innovative diagnostic tools and algorithms that go beyond single cells and deal with modules and packs are essential for early detection of off-normal issues. High-resolution tools with known detection limits are key to developing appropriate mitigation strategies. With the advent of rapid impedance spectroscopy that can generate a broadband impedance spectrum in ~10 sec, the case for impedance-based diagnostics that can be readily aligned with other methods, such as incremental capacity or dQ.dV -1 , has become promising. This study used the aforementioned diagnostic methods to identify realistic in-vehicle battery abnormalities (e.g., localized self-discharge and non-uniform aging), in series (up to 10S) and parallel (4P) strings, using 16 Ah graphite/NMC cells. The impedance-based diagnostic is found to be sensitive to the string size and state. Depending on the type of abnormality, detection frequency varied. The dQ.dV -1 method showed the potential to detect long-term aging-related heterogeneity in modules. In general, both the impedance and dQ.dV -1 methods were able to detect series strings’ abnormalities, but struggled to find those issues within parallel modules.

25 ENERGY STORAGE↗

Measurement of High-temperature Thermophysical Properties of Bulk and Coatings Using Modulated Photothermal Radiometry

This paper presents the development of instrumentation for the measurement of high-temperature thermal conductivity of bulk and coatings using a modulated photothermal radiometry (MPR) method, where a sample is heated by an intensity-modulated laser to probe into different layers of the sample. While MPR has been previously established, most of the previous studies only focus on the measurement at room temperature. The MPR has not been well studied for measurements of bulk and coating materials at high temperatures, which are increasingly important for a multitude of applications, such as materials used in the concentrating solar power (CSP) plants and the nuclear reactors. MPR is a non-contact technique that utilizes the intrinsic thermal emission from the specimens for thermometry, which is favorable for measurements at high temperatures in harsh environment. The authors designed and utilized a sample holder suitable for high temperature measurement up to 973 K with good temperature uniformity within the sample. The high-temperature MPR setup was validated by measuring bulk materials with known thermal conductivity. The setup and technique were then extended to the measurement of black solar-absorbing coatings of 10 to 50 μm thick on various substrates by modulating the frequency of the laser heating beam and the thermal penetration depth. Here, the studies showed that thermal conductivities of typical solar-absorbing coatings are 0.4 ~ 0.8 W m -1 K -1 , indicating a possibly large temperature drop within the coating under high solar irradiation flux, such as over 1000-sun for central solar towers in CSP plants.

14 SOLAR ENERGY↗

Parameter extraction approaches for compact modeling of thermoelectric modules

Thermoelectric (TE) cooling has experienced rapid advancements with the foundational understanding of TE materials. TE modules, compact and lightweight devices, have become the prevalent approach for implementing TE technologies. Accurately quantifying TE physical parameters (Seebeck coefficient α, thermal conductivity κ, and thermal resistance ρ) is challenging due to the dynamic temperature changes in operation. Furthermore, extracting lumped property parameters is crucial for designing energy systems using TE modules. Existing research has several limitations, such as lack of comparative analysis between prevalent formulae, reliance on potentially inaccurate vendor-supplied data, disregard for fundamental assumptions, and absence of empirical measurements. Further, this study addresses these gaps by conducting TE material characterization, comparing three existing formulae using vendor datasheets, designing a laboratory test facility for model validation and refinement, and outlining a structured data extraction procedure. The study's novelty lies in multiple key contributions: (1) a detailed comparative analysis of existing formulae for extracting TE property parameter; (2) executing experimental work in a laboratory setting to validate the model and elucidate its limitations; (3) highlighting potential risks; (4) clarifying possible assumptions from both material and engineering perspectives; and (5) considering temperature differential impacts. This comprehensive approach addresses the current research gaps and provides valuable insights into the design and application of TE modules in various energy systems.

36 MATERIALS SCIENCE↗

Hypofractionated Accelerated Radiotherapy Using Concomitant Intensity-Modulated Radiotherapy Boost Technique for Localized High-Risk Prostate Cancer: Acute Toxicity Results

Purpose: To evaluate the acute toxicities of hypofractionated accelerated radiotherapy (RT) using a concomitant intensity-modulated RT boost in conjunction with elective pelvic nodal irradiation for high-risk prostate cancer. Methods and Materials: This report focused on 66 patients entered into this prospective Phase I study. The eligible patients had clinically localized prostate cancer with at least one of the following high-risk features (Stage T3, Gleason score {>=}8, or prostate-specific antigen level >20 ng/mL). Patients were treated with 45 Gy in 25 fractions to the pelvic lymph nodes using a conventional four-field technique. A concomitant intensity-modulated radiotherapy boost of 22.5 Gy in 25 fractions was delivered to the prostate. Thus, the prostate received 67.5 Gy in 25 fractions within 5 weeks. Next, the patients underwent 3 years of adjuvant androgen ablative therapy. Acute toxicities were assessed using the Common Terminology Criteria for Adverse Events, version 3.0, weekly during treatment and at 3 months after RT. Results: The median patient age was 71 years. The median pretreatment prostate-specific antigen level and Gleason score was 18.7 ng/L and 8, respectively. Grade 1-2 genitourinary and gastrointestinal toxicities were common during RT but most had settled at 3 months after treatment. Only 5 patients had acute Grade 3 genitourinary toxicity, in the form of urinary incontinence (n = 1), urinary frequency/urgency (n = 3), and urinary retention (n = 1). None of the patients developed Grade 3 or greater gastrointestinal or Grade 4 or greater genitourinary toxicity. Conclusion: The results of the present study have indicated that hypofractionated accelerated RT with a concomitant intensity-modulated RT boost and pelvic nodal irradiation is feasible with acceptable acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose to Larynx Predicts for Swallowing Complications After Intensity-Modulated Radiotherapy

Purpose: To evaluate early swallowing after intensity-modulated radiotherapy for head and neck squamous cell carcinoma and determine factors correlating with aspiration and/or stricture. Methods and Materials: Consecutive patients treated with intensity-modulated radiotherapy with or without chemotherapy between September 2004 and August 2006 at the Dana Farber Cancer Institute/Brigham and Women's Hospital were evaluated with institutional review board approval. Patients underwent swallowing evaluation after completion of therapy; including video swallow studies. The clinical- and treatment-related variables were examined for correlation with aspiration or strictures, as well as doses to the larynx, pharyngeal constrictor muscles, and cervical esophagus. The correlation was assessed with logistic regression analysis. Results: A total of 96 patients were evaluated. Their median age was 55 years, and 79 (82%) were men. The primary site of cancer was the oropharynx in 43, hypopharynx/larynx in 17, oral cavity in 13, nasopharynx in 11, maxillary sinus in 2, and unknown primary in 10. Of the 96 patients, 85% underwent definitive RT and 15% postoperative RT. Also, 28 patients underwent induction chemotherapy followed by concurrent chemotherapy, 59 received concurrent chemotherapy, and 9 patients underwent RT alone. The median follow-up was 10 months. Of the 96 patients, 31 (32%) had clinically significant aspiration and 36 (37%) developed a stricture. The radiation dose-volume metrics, including the volume of the larynx receiving {>=}50 Gy (p = 0.04 and p = 0.03, respectively) and volume of the inferior constrictor receiving {>=}50 Gy (p = 0.05 and p = 0.02, respectively) were significantly associated with both aspiration and stricture. The mean larynx dose correlated with aspiration (p = 0.003). Smoking history was the only clinical factor to correlate with stricture (p = 0.05) but not aspiration. Conclusion: Aspiration and stricture are common side effects after intensity-modulated radiotherapy for head-and-neck squamous cell carcinoma. The dose given to the larynx and inferior constrictors correlated with these side effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The M. D. Anderson Symptom Inventory-Head and Neck Module, a Patient-Reported Outcome Instrument, Accurately Predicts the Severity of Radiation-Induced Mucositis

Purpose: To compare the M. D. Anderson Symptom Inventory-Head and Neck (MDASI-HN) module, a symptom burden instrument, with the Functional Assessment of Cancer Therapy-Head and Neck (FACT-HN) module, a quality-of-life instrument, for the assessment of mucositis in patients with head-and-neck cancer treated with radiotherapy and to identify the most distressing symptoms from the patient's perspective. Methods and Materials: Consecutive patients with head-and-neck cancer (n = 134) completed the MDASI-HN and FACT-HN before radiotherapy (time 1) and after 6 weeks of radiotherapy or chemoradiotherapy (time 2). The mean global and subscale scores for each instrument were compared with the objective mucositis scores determined from the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0. Results: The global and subscale scores for each instrument showed highly significant changes from time 1 to time 2 and a significant correlation with the objective mucositis scores at time 2. Only the MDASI scores, however, were significant predictors of objective Common Terminology Criteria for Adverse Events mucositis scores on multivariate regression analysis (standardized regression coefficient, 0.355 for the global score and 0.310 for the head-and-neck cancer-specific score). Most of the moderate and severe symptoms associated with mucositis as identified on the MDASI-HN are not present on the FACT-HN. Conclusion: Both the MDASI-HN and FACT-HN modules can predict the mucositis scores. However, the MDASI-HN, a symptom burden instrument, was more closely associated with the severity of radiation-induced mucositis than the FACT-HN on multivariate regression analysis. This greater association was most likely related to the inclusion of a greater number of face-valid mucositis-related items in the MDASI-HN compared with the FACT-HN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hypofractionated Intensity-Modulated Arc Therapy for Lymph Node Metastasized Prostate Cancer

Purpose: To determine the planning results and acute toxicity after hypofractionated intensity-modulated arc radiotherapy and androgen deprivation for lymph node metastasized (Stage N1) prostate cancer. Methods and Materials: A total of 31 patients with Stage T1-T4N1M0 prostate cancer were treated with intensity-modulated arc radiotherapy and 3 years of androgen deprivation as primary treatment. The clinical target volume (CTV{sub p}) was the prostate and seminal vesicles. Elective lymph node areas ({sub e}) were delineated and expanded by 2 mm to create the CTV{sub e}. The planning target volumes (PTV{sub p} and PTV{sub e}) were created using a three-dimensional expansion of the CTV{sub p} and CTV{sub e}, respectively, of 7 mm. A median dose of 69.3 Gy and 50 Gy was prescribed to the PTV{sub p} and PTV{sub e} respectively, to be delivered in 25 fractions. Upper and lower gastrointestinal toxicity was scored using the Radiation Therapy Oncology Group toxicity and radiotherapy-induced lower intestinal toxicity scoring system. Genitourinary toxicity was scored using a combined Radiation Therapy Oncology Group, LENT-SOMA (late effects normal tissue-subjective, objective, management, analytic), and Common Toxicity Criteria toxicity scoring system. Results: The median follow-up time was 3 months. The mean prescription dose to the CTV{sub p} and PTV{sub p} was 70.4 Gy and 68.6 Gy, respectively. The minimal dose to the CTV{sub e} and PTV{sub e} was 49.0 Gy and 47.0 Gy, respectively. No acute Grade 2 or greater gastrointestinal toxicity occurred. Fourteen patients developed acute Grade 2 lower gastrointestinal toxicity. Acute Grade 3 and 2 genitourinary toxicity developed in 2 and 14 patients, respectively. Conclusion: The results of our study have shown that hypofractionated intensity-modulated arc radiotherapy as primary therapy for N1 prostate cancer is feasible with low toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Experience With Image-Guided Radiotherapy in an Accelerated Partial Breast Intensity-Modulated Radiotherapy Protocol

Purpose: To explore the feasibility of fiducial markers for the use of image-guided radiotherapy (IGRT) in an accelerated partial breast intensity modulated radiotherapy protocol. Methods and Materials: Nineteen patients consented to an institutional review board approved protocol of accelerated partial breast intensity-modulated radiotherapy with fiducial marker placement and treatment with IGRT. Patients (1 patient with bilateral breast cancer; 20 total breasts) underwent ultrasound guided implantation of three 1.2- x 3-mm gold markers placed around the surgical cavity. For each patient, table shifts (inferior/superior, right/left lateral, and anterior/posterior) and minimum, maximum, mean error with standard deviation were recorded for each of the 10 BID treatments. The dose contribution of daily orthogonal films was also examined. Results: All IGRT patients underwent successful marker placement. In all, 200 IGRT treatment sessions were performed. The average vector displacement was 4 mm (range, 2-7 mm). The average superior/inferior shift was 2 mm (range, 0-5 mm), the average lateral shift was 2 mm (range, 1-4 mm), and the average anterior/posterior shift was 3 mm (range, 1 5 mm). Conclusions: This study shows that the use of IGRT can be successfully used in an accelerated partial breast intensity-modulated radiotherapy protocol. The authors believe that this technique has increased daily treatment accuracy and permitted reduction in the margin added to the clinical target volume to form the planning target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Image Guidance With Cone-Beam Computed Tomography for Head-and-Neck Cancer Intensity-Modulated Radiotherapy: A Prospective Study

Purpose: To report on a prospective clinical trial of the use of daily kilovoltage cone-beam computed tomography (CBCT) to evaluate the interfraction and residual error motion of patients undergoing intensity-modulated radiotherapy for head-and-neck cancer. Methods and Materials: Patients were treated with intensity-modulated radiotherapy with an Elekta linear accelerator using a mounted CBCT scanner. CBCT was performed before every treatment, and translational (but not rotational) corrections were performed. At least once per week, a CBCT scan was obtained after intensity-modulated radiotherapy. Variations were measured in the medial-lateral, superoinferior, and anteroposterior dimensions, as well as in the rotation around these axes. Results: A total of 28 consecutive patients (1,013 CBCT scans) were studied. The average interfraction shift was 1.4 +- 1.4, 1.7 +- 1.9, and 1.8 +- 2.1 mm in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. The corresponding average residual error shifts were 0.7 +- 0.8, 0.9 +- 0.9, and 0.9 +- 0.9 mm. These data indicate that in the absence of daily CBCT image-guided radiotherapy, a clinical target volume to planning target volume margin of 3.9, 4.1, and 4.9 mm is needed in the medial-lateral, superoinferior, and anteroposterior dimensions, respectively. With daily CBCT, corresponding margins of 1.6, 2.5, and 1.9 mm should be acceptable. Subgroup analyses showed that larynx cancers and/or intratreatment weight loss indicate a need for slightly larger clinical target volume to planning target volume margins. Conclusion: The results of our study have shown that image-guided radiotherapy using CBCT for head-and-neck cancer is effective. These data suggest it allows a reduction in the clinical target volume to planning target volume margins by about 50%, which could facilitate future studies of dose escalation and/or improved toxicity reduction. Caution is particularly warranted for cases in which the targets are mobile (e.g., the tongue).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗