Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Operating Deflection Shapes for the Space Shuttle Partial Stack Rollout

In November of 2003 a rollout test was performed to gain a better understanding of the dynamic environment for the Space Shuttle during transportation from the Vehicle Assembly Building to the launch pad. This was part of a study evaluating the methodology for including the rollout dynamic loads in the Space Shuttle fatigue life predictions. The rollout test was conducted with a partial stack consisting of the Crawler Transporter, Mobile Launch Platform, and the Solid Rocket Boosters with an interconnecting crossbeam. Instrumentation included over 100 accelerometers. Data was recorded for steady state speeds, start-ups and stops, and ambient wind excitations with the vehicle at idle. This paper will describe the operating deflection shape analysis performed using the measured acceleration response data. The response data for the steady state speed runs were dominated by harmonics of the forcing frequencies, which were proportional to the vehicle speed. Assuming a broadband excitation for the wind, analyses of the data sets with the vehicle at idle were used to estimate the natural frequencies and corresponding mode shapes. Comparisons of the measured modal properties with numerical predictions are presented.

Buehrle, Ralph D.↗

New Flutter Analysis Technique for CFD-based Unsteady Aeroelasticity

This paper presents a flutter analysis technique for the transonic flight regime. The technique uses an iterative approach to determine the critical dynamic pressure for a given mach number. Unlike other CFD-based flutter analysis methods, each iteration solves for the critical dynamic pressure and uses this value in subsequent iterations until the value converges. This process reduces the iterations required to determine the critical dynamic pressure. To improve the accuracy of the analysis, the technique employs a known structural model, leaving only the aerodynamic model as the unknown. The aerodynamic model is estimated using unsteady aeroelastic CFD analysis combined with a parameter estimation routine. The technique executes as follows. The known structural model is represented as a finite element model. Modal analysis determines the frequencies and mode shapes for the structural model. At a given mach number and dynamic pressure, the unsteady CFD analysis is performed. The output time history of the surface pressure is converted to a nodal aerodynamic force vector. The forces are then normalized by the given dynamic pressure. A multi-input multi-output parameter estimation software, ERA, estimates the aerodynamic model through the use of time histories of nodal aerodynamic forces and structural deformations. The critical dynamic pressure is then calculated using the known structural model and the estimated aerodynamic model. This output is used as the dynamic pressure in subsequent iterations until the critical dynamic pressure is determined. This technique is demonstrated on the Aerostructures Test Wing-2 model at NASA's Dryden Flight Research Center.

Pak, Chan-gi↗

Radiation protection program for early detection of breast cancer in a mammography facility

Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-03: Quantitative CT-Based Analysis to Assess Lung Injury Following Proton Radiotherapy

Purpose: Relative to photon alternatives, the increased dose-conformity associated with proton therapy is expected to reduce the extent of radiation-induced lung toxicity. However, analysis of follow-up data is yet to be published in this area. In this study we retrospectively analyzed late-phase HU changes for proton therapy cohorts of chest wall and lung patients. Methods: From our institution’s register of patients treated using double-scattered protons, all chest wall and stereotactic lung cases (treated 2011–2012 and 2008–2014 respectively) were initially considered. Follow-up CT data were accessible for 10 chest wall cases (prescribed 50.4 GyRBE in 28 fractions) and 16 lung cases (prescribed 42–50 GyRBE in 3–4 fractions). CT time-points ranged from 0.5–3.5 years post-treatment. Planning doses were recalculated using TOPAS Monte Carlo simulations and mapped onto the follow-up images using deformable registration. Excluding internal target volumes, changes in HU between each patient’s planning and follow-up CT(s) were evaluated for dose bins of 2–30 GyRBE (2 GyRBE increments). Results: Linear increases in HU per unit dose, with correlations statistically significant at the 1% level (one-sided Spearman’s rank test), were evident for all 10 chest wall cases and 14/16 lung cases. The mean changes in HU/Gy were: 1.76 (SD=0.73) for the chest wall cohort, and 1.40 (SD=0.87) for the lung cohort. The median scan times post treatment were 21 and 12 months respectively. All 26 patients developed solid consolidation (scar-like radiographic opacities) within the exposed lung(s). Conclusion: Analysis of follow-up CTs revealed statistically significant correlations in HU-change/dose for two proton cohorts (lung and chest wall). Quantitatively, the late-phase changes we report broadly match published photon data. Further analysis of such radiographic changes, particularly via matched cohort studies drawing upon consistent imaging protocols, could play an important role in elucidating inter-modality differences and provide insight into proton RBE for lung injury. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064). This work was also funded under U19 grant CA 021239 (PI: Delaney).

60 APPLIED LIFE SCIENCES↗

Portable Vibro-acoustic Testing System for In Situ Microstructure Characterization and Metrology

Portable Vibro-acoustic Testing System for In situ Microstructure Characterization and Metrology James A. Smith, Corrie I. Nichol Idaho National Laboratory, Idaho Falls ID Mostafa Fatemi, Mayo Clinic, Rochester MN There is a need in research reactors like the INL to inspect irradiated materials and structures. The goal of this work is to develop a portable scanning infrastructure for a material characterization technique called vibro-acoustography (VA) that has been developed by INL [1] for nuclear applications to characterize fuel, cladding materials, and structures. The proposed VA technology is based on ultrasound and acoustic waves; however, it provides information beyond what is available from the traditional ultrasound techniques and can expand the knowledge on nuclear material characterization and microstructure evolution. VA is a three-dimensional (3D) imaging modality based on ultrasound-stimulated acoustic emission. VA uses the force caused by the beating of two frequencies to generate an acoustic emission signal. Due to absorption or reflection, the energy density in the object at an acoustic focal point changes to produce a “radiation force.” This force locally vibrates the object, which results in an acoustic field that depends on the characteristics of the object at that point. This acoustic field is detected for every point in the object; the resulting data is used to make an image of the object’s mechanical properties. This technology is fundamentally different from traditional ultrasound imaging. More specifically, VA is: (a) based on the “radiation force,” a nonlinear phenomenon in sound propagation, and (b) sensitive to both high and low frequency dynamic responses of the object. The combination of these two response types provides information about characteristics of the object beyond what is possible by traditional ultrasound imaging. High spatial resolution is achieved, since the radiation force is localized to the focal point of the ultrasound beam. Low-frequency information, which is a representative of structural characteristics, is gained through the radiation force mechanism at a low (beat) frequency. This paper will report on the development of a portable scanning that can be set up to characterize materials and component in open water reactors and canals in situ. We will show some initial laboratory results of images generated by vibro-acoustics of surrogate fuel plates and graphite structures and discus the design of the portable system. 1. Smith, J. A., and Kunerth, D. C., “Vibro-acoustic Sensors for Materials Characterization and Related Methods and Systems,” Patent Application 13226280, 09/06/2011.

36 MATERIALS SCIENCE↗

High and low dose radiation effects on mammary adenocarcinoma cells – an epigenetic connection

The successful treatment of cancer, including breast cancer, depends largely on radiation therapy and proper diagnostics. The effect of ionizing radiation on cells and tissues depends on the radiation dose and energy level, but there is insufficient evidence concerning how tumor cells respond to the low and high doses of radiation that are often used in medical diagnostic and treatment modalities. The purpose of this study was to investigate radiation-induced gene expression changes in the MCF7 breast adenocarcinoma cell line. Using microarray technology tools, we were able to screen the differential gene expressions profiles between various radiation doses applied to MCF-7 cells. Here, we report the substantial alteration in the expression level of genes after high-dose treatment. In contrast, no dramatic gene expression alterations were noticed after the application of low and medium doses of radiation. In response to a high radiation dose, MCF-7 cells exhibited down-regulation of biological pathways such as cell cycle, DNA replication, and DNA repair and activation of the p53 pathway. Similar dose-dependent responses were seen on the epigenetic level, which was tested by a microRNA expression analysis. MicroRNA analysis showed dose-dependent radiation-induced microRNA expression alterations that were associated with cell cycle arrest and cell death. An increased rate of apoptosis was determined by an Annexin V assay. The results of this study showed that high doses of radiation affect gene expression genetically and epigenetically, leading to alterations in cell cycle, DNA replication, and apoptosis.

59 BASIC BIOLOGICAL SCIENCES↗

Establishing Cost-Effective Allocation of Proton Therapy for Breast Irradiation

Purpose: Cardiac toxicity due to conventional breast radiation therapy (RT) has been extensively reported, and it affects both the life expectancy and quality of life of affected women. Given the favorable oncologic outcomes in most women irradiated for breast cancer, it is increasingly paramount to minimize treatment side effects and improve survivorship for these patients. Proton RT offers promise in limiting heart dose, but the modality is costly and access is limited. Using cost-effectiveness analysis, we provide a decision-making tool to help determine which breast cancer patients may benefit from proton RT referral. Methods and Materials: A Markov cohort model was constructed to compare the cost-effectiveness of proton versus photon RT for breast cancer management. The model was analyzed for different strata of women based on age (40 years, 50 years, and 60 years) and the presence or lack of cardiac risk factors (CRFs). Model entrants could have 1 of 3 health states: healthy, alive with coronary heart disease (CHD), or dead. Base-case analysis assumed CHD was managed medically. No difference in tumor control was assumed between arms. Probabilistic sensitivity analysis was performed to test model robustness and the influence of including catheterization as a downstream possibility within the health state of CHD. Results: Proton RT was not cost-effective in women without CRFs or a mean heart dose (MHD) <5 Gy. Base-case analysis noted cost-effectiveness for proton RT in women with ≥1 CRF at an approximate minimum MHD of 6 Gy with a willingness-to-pay threshold of $100,000/quality-adjusted life-year. For women with ≥1 CRF, probabilistic sensitivity analysis noted the preference of proton RT for an MHD ≥5 Gy with a similar willingness-to-pay threshold. Conclusions: Despite the cost of treatment, scenarios do exist whereby proton therapy is cost-effective. Referral for proton therapy may be cost-effective for patients with ≥1 CRF in cases for which photon plans are unable to achieve an MHD <5 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-212: Identifying Bones From MRI: A Dictionary Learnign and Sparse Regression Approach

Purpose: To develop an efficient and robust scheme to identify bony anatomy based on MRI-only simulation images. Methods: MRI offers important soft tissue contrast and functional information, yet its lack of correlation to electron-density has placed it as an auxiliary modality to CT in radiotherapy simulation and adaptation. An effective scheme to identify bony anatomy is an important first step towards MR-only simulation/treatment paradigm and would satisfy most practical purposes. We utilize a UTE acquisition sequence to achieve visibility of the bone. By contrast to manual + bulk or registration-to identify bones, we propose a novel learning-based approach for improved robustness to MR artefacts and environmental changes. Specifically, local information is encoded with MR image patch, and the corresponding label is extracted (during training) from simulation CT aligned to the UTE. Within each class (bone vs. nonbone), an overcomplete dictionary is learned so that typical patches within the proper class can be represented as a sparse combination of the dictionary entries. For testing, an acquired UTE-MRI is divided to patches using a sliding scheme, where each patch is sparsely regressed against both bone and nonbone dictionaries, and subsequently claimed to be associated with the class with the smaller residual. Results: The proposed method has been applied to the pilot site of brain imaging and it has showed general good performance, with dice similarity coefficient of greater than 0.9 in a crossvalidation study using 4 datasets. Importantly, it is robust towards consistent foreign objects (e.g., headset) and the artefacts relates to Gibbs and field heterogeneity. Conclusion: A learning perspective has been developed for inferring bone structures based on UTE MRI. The imaging setting is subject to minimal motion effects and the post-processing is efficient. The improved efficiency and robustness enables a first translation to MR-only routine. The scheme generalizes to multiple tissue classes.

60 APPLIED LIFE SCIENCES↗

SU-F-J-93: Automated Segmentation of High-Resolution 3D WholeBrain Spectroscopic MRI for Glioblastoma Treatment Planning

Purpose: We report on an automated segmentation algorithm for defining radiation therapy target volumes using spectroscopic MR images (sMRI) acquired at nominal voxel resolution of 100 microliters. Methods: Wholebrain sMRI combining 3D echo-planar spectroscopic imaging, generalized auto-calibrating partially-parallel acquisitions, and elliptical k-space encoding were conducted on 3T MRI scanner with 32-channel head coil array creating images. Metabolite maps generated include choline (Cho), creatine (Cr), and N-acetylaspartate (NAA), as well as Cho/NAA, Cho/Cr, and NAA/Cr ratio maps. Automated segmentation was achieved by concomitantly considering sMRI metabolite maps with standard contrast enhancing (CE) imaging in a pipeline that first uses the water signal for skull stripping. Subsequently, an initial blob of tumor region is identified by searching for regions of FLAIR abnormalities that also display reduced NAA activity using a mean ratio correlation and morphological filters. These regions are used as starting point for a geodesic level-set refinement that adapts the initial blob to the fine details specific to each metabolite. Results: Accuracy of the segmentation model was tested on a cohort of 12 patients that had sMRI datasets acquired pre, mid and post-treatment, providing a broad range of enhancement patterns. Compared to classical imaging, where heterogeneity in the tumor appearance and shape across posed a greater challenge to the algorithm, sMRI’s regions of abnormal activity were easily detected in the sMRI metabolite maps when combining the detail available in the standard imaging with the local enhancement produced by the metabolites. Results can be imported in the treatment planning, leading in general increase in the target volumes (GTV60) when using sMRI+CE MRI compared to the standard CE MRI alone. Conclusion: Integration of automated segmentation of sMRI metabolite maps into planning is feasible and will likely streamline acceptance of this new acquisition modality in clinical practice.

60 APPLIED LIFE SCIENCES↗

INSPIRE Phase I Development

Sandia National Laboratories (Sandia) and Makel Engineering, Inc developed a pathway towards an advanced multi-modal sensor system suitable for in-situ analysis of exhaled volatile organic compounds (VOCs) for pilots, divers and field patients. Our proposed In-Mask Sensors for Physiological Investigation of Respiratory Exhalation - INSPIRE, will combine micro-gas chromatograph (microGC) and miniature ion mobility spectrometer (IMS) for detection of trace amounts of exhaled breath VOCs with miniature solid state sensors for inorganic compounds found in breath such as oxygen, carbon dioxide, moisture and the inert gases nitrogen, argon and helium. To develop clear developmental pathway towards that goal Sandia demonstrated a new version of its ion-mobility spectrometer detection technology for VOC detection, while Makel demonstrated detection of inorganics and concepts for mask integration. Sandia demonstrated detection of many compounds from the EPA TO-15 Test Mixture, which is representative of many classes of compounds found in air, and can be purchased as a gas standard from a variety of suppliers. The work demonstrated for phase I was sufficient to move the team into phase II of the program, where a full prototype unit will be developed. This CRADA provided clear value to the taxpayer by allowing a US small business to continue to phase II of a competitive STTR proposal for the Air Force. This process will help to transition Sandia’s technology into the marketplace to address a clear DoD requirement.

Moorman, Matthew↗

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial-velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial-velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm s{sup −1}, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial-velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser fRequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on the radial-velocity precision due to pixel-position nonuniformities and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter–McLaughlin effect.

79 ASTRONOMY AND ASTROPHYSICS↗

PACOSS program overview and status

Many future civilian and military large space structures (LSS) will have as performance objectives stringent pointing accuracies, short settling times, relatively fast response requirements, or combinations thereof. Many of these structures will be large, light weight, and will exhibit high structural modal density at low frequency and within the control bandwidth. Although it is possible in principle to achieve structural vibration control through purely active means, experience with complex structures has shown that the realities of plant model inaccuracies and sensor/actuator dynamics frequently combine to produce substandard performance. A more desirable approach is to apply passive damping technology to reduce the active control burden. Development of the technology to apply this strategy is the objective of the PACOSS (Passive and Active Control OF Space Structures) program. A key element in the PACOSS program is the Representative System Article (RSA). The RSA is a generic paper system that serves as a testbed for damping and controls studies. It also serves as a basis for design of the smaller Dynamic Test Article (DTA), a hardware testbed for the laboratory validation of analysis and design practices developed under PACOSS.

Rogers, L. C.↗

Perfusion Angiography of the Foot in Patients with Critical Limb Ischemia: Description of the Technique

ObjectiveTo study the feasibility of 2D perfusion imaging in critical limb ischemia (CLI).Methods/ResultsPerfusion angiography is a new technology which was tested in 18 patients with CLI of the foot. A standardized protocol was used with a catheter placed at the mid-part of the popliteal artery, and a total of 9 cc of non-ionic iodinated contrast material was injected at a rate of 3 cc/sec. The technology is based on early cardiology research where iodinated contrast agents were used for imaging of cardiac perfusion. During the first pass of the contrast, there is a significant diffusion of the contrast agents into the interstitial space, particularly for non-ionic and low-molecular-weight compounds.DiscussionThe original angiography data can be used to make a time–density curve, which represents the actual perfusion of the foot in time. Angiographic perfusion imaging is a post-processing modality for which no extra contrast or radiation is needed. With this technique, it is possible to get more information about the perfusion status and microcirculation of the foot. This is a step toward functional imaging in CLI patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of dynamic crystal plasticity with a Lagrangian discontinuous Galerkin hydrodynamic method

Here we present a new Lagrangian modal discontinuous Galerkin (DG) hydrodynamic method that supports a dynamic dislocation based crystal plasticity model for simulating the mechanical behavior of crystallographic materials, both single crystal and polycrystalline, under dynamic conditions. A modal DG approach is used to evolve fields relevant to conservation laws. These fields are approximated by Taylor series polynomials of varying degree. These polynomials describe macro-scale hydrodynamic behavior while their evolution is determined by evaluating the dynamic crystal plasticity model at material points within the element. The dynamic crystal plasticity model is sensitive to the time increment size, with too large of time increments leading to instability in the model. To mitigate this, the temporal evolution of the dynamic crystal plasticity model is achieved with the combination of a sub-incrementing scheme with Heun’s third-order time integration scheme, which is also used to temporally evolve the governing equations. The implementation of the dynamic crystal plasticity model within the DG framework is tested using a 2D approximation of the Taylor impact test with a single crystal material, using quadratic elements that have faces that can bend. In addition to the standard continuous material modeling, we propose a new simulation method that would represent the heterogeneous behavior of polycrystalline microstructures within an element by varying the position and material properties of the material points within the element. This method is demonstrated using random orientation distributions on materials points that are arranged in both structured and random configurations.

42 ENGINEERING↗

Role of Genetic Polymorphisms in NFKB-Mediated Inflammatory Pathways in Response to Primary Chemoradiation Therapy for Rectal Cancer

Purpose: To investigate whether polymorphisms of genes related to inflammation are associated with pathologic response (primary endpoint) in patients with rectal cancer treated with primary chemoradiation therapy (PCRT). Methods and Materials: Genomic DNA of 159 patients with locally advanced rectal cancer treated with PCRT was genotyped for polymorphisms rs28362491 (NFKB1), rs1213266/rs5789 (PTGS1), rs5275 (PTGS2), and rs16944/rs1143627 (IL1B) using TaqMan single nucleotide polymorphism genotyping assays. The association between each genotype and pathologic response (poor response vs complete or partial response) was analyzed using logistic regression models. Results: The NFKB1 DEL/DEL genotype was associated with pathologic response (odds ratio [OR], 6.39; 95% confidence interval [CI], 0.78-52.65; P=.03) after PCRT. No statistically significant associations between other polymorphisms and response to PCRT were observed. Patients with the NFKB1 DEL/DEL genotype showed a trend for longer disease-free survival (log-rank test, P=.096) and overall survival (P=.049), which was not significant in a multivariate analysis that included pathologic response. Analysis for 6 polymorphisms showed that patients carrying the haplotype rs28362491-DEL/rs1143627-A/rs1213266-G/rs5789-C/rs5275-A/rs16944-G (13.7% of cases) had a higher response rate to PCRT (OR, 8.86; 95% CI, 1.21-64.98; P=.034) than the reference group (rs28362491-INS/rs1143627-A/rs1213266-G/rs5789-C/rs5275-A/rs16944-G). Clinically significant (grade ≥2) acute organ toxicity was also more frequent in patients with that same haplotype (OR, 4.12; 95% CI, 1.11-15.36; P=.037). Conclusions: Our results suggest that genetic variation in NFKB-related inflammatory pathways might influence sensitivity to primary chemoradiation for rectal cancer. If confirmed, an inflammation-related radiogenetic profile might be used to select patients with rectal cancer for preoperative combined-modality treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Machine learning based rate optimization under geologic uncertainty

We propose a novel approach for rate optimization during a waterflood under geologic uncertainty in reservoir properties such as permeability and porosity. The traditional approach typically involves several runs of the forward simulator. This may not scale well when the optimization is to be performed at the full field-level and over multiple geologic realizations. A machine-learning (ML) based approach which is quick and scalable for rate optimization over multiple geologic realizations is proposed instead. The training data for the model is generated by running the forward simulator with randomly assigned well rates using multiple geologic realizations. A reduced order representation of the permeability heterogeneity in each of the realizations is derived using a grid connectivity transformation (GCT). This step involves finding basis functions corresponding to the different modal frequencies of the grid connectivity represented by the grid Laplacian. The projection of the heterogeneous property field along these basis functions gives the basis coefficients that form the reduced order representation. Subsequently, for each training datapoint, streamlines are traced and the minimum time of flight (TOF) representing the tracer breakthrough time at each producer is recorded. The basis coefficients and well rates are fed to a machine learning model as input and the minimum TOF at the producers forms the output of the model. This trained model can then be used along with an optimizer for computing the optimal injection rates to maximize the injection sweep efficiency. This corresponds to minimizing the variance in the minimum TOF within each well group. Different architectures of neural network are tested using 5-fold cross validation to decide the best ML model to compute the streamline time of flight. The trained model is used to perform well rate optimization over multiple realizations of geology by using a risk tolerance penalty. The optimal well rates thus obtained are compared with two cases: a) equal well rates assigned to all injectors and producers and b) well rates obtained by optimizing over a single realization without considering the uncertainty in geology. The optimal well rates are seen to offer better oil recovery and sweep efficiency than both cases.

02 PETROLEUM↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

PACOSS program status and results

Future large space systems (LSS), both civilian and military, will have performance objectives which require stringent pointing accuracies, relatively fast retargeting times, short settling times, accurate dynamic shape requirements, or combinations thereof. Many of these structures will be large but lightweight and will exhibit a dense, low-frequency modal spectrum with significant content within the control bandwidth. Although it is possible in principle to achieve structural vibration control with purely active means, experience with complex structures has shown that the realities of plant model inaccuracies and real sensor and actuator dynamics frequently combine to produce disappointing results. It was shown that a combination of passive and active control will result in a simpler system which can be expected to be more reliable and less expensive than a corresponding system utilizing active control exclusively. The goals of the Passive and Active Control of Space Structures (PACOSS) program consist of a thorough investigation of the relative roles of passive active vibration control, and the development of validated means of vibration control. The program approach, representative system article, dynamic test article, and test status and results are outlined.

Richards, K. E., Jr.↗