Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ionizing radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

TH-A-BRF-01: A Probabilistic Bayesian Approach to Derive Electron Density From MRI for Radiation Therapy Treatment Planning

Purpose: MRI significantly improves the accuracy and reliability of target delineation for patient simulation and treatment planning in radiation therapy, due to its superior soft tissue contrast as compared to CT. An MRI based simulation will reduce cost and simplify clinical workflow with zero ionizing radiation. However, MRI lacks the key electron density information. The purpose of this work is to develop a reliable method to derive electron density from MRI. Methods: We adopt a probabilistic Bayesian approach for electron density mapping based on T1-weighted head MRI. For each voxel, we compute conditional probability of electron densities given its: (1) T1 intensity and (2) geometry in a reference anatomy, obtained by deformable image registration between the MRI of test patient and atlas. Intensity and geometry information are combined into a unifying posterior probability density function whose mean gives the electron density. Mean absolute HU error between the estimated and true CT, as well as ROC's for bone detection (HU>200) were calculated for 8 patients. The performance was compared with a global intensity approach based on T1 and no density correction (set whole head to water). Results: The proposed technique significantly reduced the errors in electron density estimation, with a mean absolute HU error of 132, compared with 139 for deformable registration (p=10{sup −3}), 371 for the intensity approach (p=10{sup −5}) and 282 without density correction (p=2×10{sup −4}). For 90% sensitivity in bone detection, the proposed method had a specificity of 85% and that for deformable registration, intensity and without density correction are 80%, 24% and 10% respectively. Conclusion: The proposed unifying method provides accurate electron density estimation and bone detection from MRI of the head with highly heterogeneous regions. This paves the way for accurate dose calculation and generating reference images for patient setup in MRI-based treatment planning.

60 APPLIED LIFE SCIENCES↗

P0004-1 quick look

The P0004-1 'Seeds in Space' experiment consisted of six sealed aluminum canisters which contained tomato seeds and a variety of other seeds for the study of space radiation effects on the seeds. The seeds were contained in cloth bags. Interspersed among the bags of seeds were ten dosimeter packets to monitor the accumulated ionizing radiation exposure of the seeds. In addition to the ten flight dosimeter packets, four ground control packets and one ground movement packet were also included as part of the experiment. The P0004-1 experiment was mounted on the F2 tray, near the trailing edge of the LDEF orbiter. The results indicate that the neutron fluences were higher in the P0004 canisters than in that of P0006. The difference was much greater for thermal neutrons than resonance neutrons. This is consistent with shielding.

Source record↗

Theoretical Studies of Starburst Infrared Emission: Luminosity Indicators in Dusty Photoionized Environments

The luminosity of the central source in ionizing radiation is an essential parameter in a photoionized environment and is one of the most fundamental physical quantities one can measure. We outline a method of determining the luminosity for any emission-line region using only infrared data. In dusty environments, grains compete with hydrogen in absorbing continuum radiation. Grains produce infrared emission, and hydrogen produces recombination lines. We have computed a very large variety of photoionization models, using ranges of abundances, grain mixtures, ionizing continua, densities, and ionization parameters. The conditions were appropriate for such diverse objects as H(II) regions, planetary nebulae, starburst galaxies, and the narrow- and broad-line regions of active nuclei. The ratio of the total thermal grain emission relative to H-Beta (IR/H-Beta) is the primary indicator of whether the cloud behaves as a classical Stroemgren sphere (a hydrogen-bounded nebula) or whether grains absorb most of the incident continuum (a dust-bounded nebula). We find two global limits: when IR/H-Beta < 100, infrared recombination lines determine the source luminosity in ionizing photons; when IR/H-Beta >> 100, the grains act as a bolometer to measure the luminosity.

Bottorff, Mark↗

A Radiation Safety Analysis for Lunar Lava Tubes

The purpose of this work is an assessment of the lunar lava tubes physical characteristics and an evaluation of the their actual safety features from the point of view of the ionizing radiation environment as potential habitats for future lunar exploration crews. Additional information is contained in the original extended abstract.

DeAngelis, G.↗

Negative radiation in partially ionized gas

A stationary, nonlinear collisional-radiative model for high-temperature atomic oxygen is presented. Populations of negative ions, electrons, positive ions and excited atoms and intensities of spectral, continuum and dielectronic recombination radiation are calculated in a wide range of conditions. Calculated total continuum emission is in good agreement with existing measurements. The contribution of the negative ion emission to the total continuum emission is found to be significant.

Soon, W. H.↗

Outcomes of a Mini Technical Interchange Meeting Concerning the Risk of Cardiovascular Disease from Exposure to Space Radiation

The NASA Human Research Program’s (HRP) Space Radiation Element (SRE) funds research to characterize and mitigate adverse health outcomes from exposure to space radiation to enable deep space exploration and sustained human presence in space. Damage to the cardiovascular system has been observed after exposure to clinically relevant doses of ionizing radiation. However, an association between lower radiation doses and cardiovascular disease (CVD) remains controversial, and questions pertaining to dose thresholds, radiation quality and dose-rate effects, and gaps in characterizing the mechanisms and major pathways of CVD remain. To solicit new ideas for characterizing and mitigating this risk, the SRE is organizing a series of miniature technical interchange meeting (Tiny-TIM) that provide a venue for HRP-funded investigators and thought leaders to present ongoing work and engage in open discussion on relevant topics. The initial Tiny-TIM: Upping the Ante on Characterizing and Mitigating Cardiovascular Disease Risk from Space Radiation Exposure, held at the NASA HRP Investigators’ Workshop (IWS) earlier this year, consisted of two 90-minute sessions; the first focused on current knowledge of CVD risk from space radiation exposure, and the second focused on innovative ideas, and newer approaches and techniques to accelerate research. The second session was followed by an open, spirited discussion amongst peers on the current issues impeding the characterization of CVD risk. SRE leadership facilitated the discussion using a set of pressing questions and gaps in knowledge that need to be addressed by the scientific community. This poster presents the outcomes of the Tiny-TIM, along with proposed future workshops and the SRE’s other initiatives.

Janapriya Saha↗

A nano-structured ZnO film as diagnostic X-ray sensor

Currently some international organizations such as WHO and IAEA have shown concerns about the quality of diagnostic services in clinics and hospitals that use ionizing radiation. In fact, the IAEA recommend that the characteristics of the X-ray beam must be adjusted to obtain the highest quality of the radiographic image with the minimum exposure to the patient. Several types of detectors may be used for monitoring X-ray beams, such as: ionization chamber, photodiode, phototransistor, among others. Recently nano-structured films made of various types of metal oxide materials have been used for various technological applications. Accordingly, the purpose of this paper is to present a sort of device based on a nano-structured zinc oxide (ZnO) to operate as a diagnostic X-ray sensor. By depositing a thin film on the glass substrate some ZnO semiconductor samples were built by sputtering techniques and then mounted in a BNC type connector to perform the electrical characterization. To test the device, we choose a standard X-Ray beam, the RQR9 radiation quality, which is normally used as the tool and condition for calibrating diagnostic X-Ray instruments in the energy range of computed tomography, in accordance with the stated requirements of IEC 61267. A 6430 sub-femto-ammeter, Keithley, was used as electrometer to perform the output readings and simultaneously bias the ZnO sensor. Analysis of the angular dependence and the dose rate were performed to evaluate how the device responds under the RQR9 radiation spectra. Although the results have shown that the ZnO film presents a certain angular dependence, if an angle of incidence of photons is selected, the device displays reproducibility as X-ray sensor and has the feature of radiation hardness unlike other types of semiconductor electronic devices typically used as an X-ray detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ames collaborative study of cosmic ray neutrons - Mid-latitude flights

Three aircraft flights at 12.5 km have yielded data on cosmic-ray neutron-flux densities, neutron dose equivalent rates, and exposure rates for ionizing radiation. The data, collected at 45, 38, and 48 degrees N, indicate: (1) neutron dose equivalent rates of 0.20, 0.14, and 0.22 mrem/hour, (2) exposure rates from the ionizing component of 0.37, 0.31, and 0.41 mR/hour, (3) that the dose equivalent from 3-13-MeV neutrons is 30% of the total for all neutrons, (4) that exposure rates decrease exponentially with decreasing pressure altitude with a 140 g/sq cm attenuation length at 43 degrees N geomagnetic latitude, and (5) that the ionizing component of cosmic ray secondaries is less sensitive to latitude changes than the neutron component.

Hewitt, J. E.↗

Radiation damage in high-voltage silicon solar cells

Three types of open circuit high voltage solar cells were tested to determine their performance after exposure to 1 MeV electron irradiations. The cells with a relatively deep n-type emitter were more susceptible to radiation damage than other high open circuit high voltage cells. The use of diffused or ion implanted junctions leads to open circuit high voltage cell designs that are less susceptible to radiation damage. These latter two types of cells show degradations that are typical of the 0.1 ohm-cm material from which they are fabricated. Furthermore, exposure to ionizing radiation causes oxide degradation and decreased cell performance in cells that depend on a charged oxide to achieve significant cell properties. Hence, the combination of a charged oxide and a relatively deep n-type emitter is not recommended for incorporation into a cell designed for use in the particulate radiation environment of space.

Weinberg, I.↗

Effects of Radiation on Capacitor Dielectrics

Data gathered on key design parameters. Report discusses study of electrical and mechanical properties of irradiated polymer dielectric materials. Data compiled for use by designers of high-energy-density capacitors that operate in presence of ionizing radiation. Study focused on polycarbonates, polyetheretherketones, polymethylpentenes, polyimides (including polyetherimide), polyolefins, polysulfones (including polyethersulfone and polyphenylsulfone), and polyvinylidene fluorides.

Bouquet, F. L.↗

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

With the advent of longer duration space missions, pharmaceutical use in space has increased. During the first 33 space shuttle missions, crew members took more than 500 individual doses of 31 different medications . Anecdotal reports from crew members described medications as generally "well tolerated" and "effective". However, reported use of increased medication doses and discrepancies in ground vs. flight efficacy may result from reduced potency or altered bioavailability due to changes in chemical and/or physical parameters of pharmaceutical stability. Based on preliminary results from a ground-based irradiation and an inflight study on pharmaceutical stability, three susceptible medications, Amoxicillin/Clavulanate and Sulfamethoxazole/trimethoprim antibiotics tablets and promethazine (PMZ), an antihistamine were selected for testing using two types of Oliver-Tolas bags, TPC-1475(Clear) and TPF-0599B (Foil) for radiation Shielding effectiveness. The material composition of the bags included aluminum coated Mylar sheathing coated with multifunctional nanocomposities based on polyethylene with dispersed boron-rich nanophases. Two bags of each medication were irradiated for different time intervals with 14.6 rad/min to achieve 0.1 Gy, 1 Gy and 10 Gy of cumulative radiation dose. Active pharmaceutical content (API) in each medication was determined and results analyzed. No significant difference in API content was observed between control and irradiated samples for both antibiotic tablets suggesting both types of bags may offer protection against gamma radiation; results with PMZ were inconclusive. These preliminary results suggest that Oliver-Tolas TPL-1475 and TPF-0599B materials may possess characteristics suitable for protection against ionizing radiation and can be considered for designing and further testing of FMD technology.

Du, Brian↗

Radiation Effects on the Performance of Advanced Sulfur Monochloride Chlorination Processes

Advanced sulfur chloride-based chlorination technologies are being developed to enable efficient recycling of aluminum and zirconium-based materials used in the nuclear industry. However, the impacts of ionizing radiation on the performance of these sulfur chloride compounds are not well established, despite this being critical knowledge for assessing their feasibility and longevity under envisioned process conditions. Here, in the present article, we report on the effects of cobalt-60 gamma irradiation (≤ 5 MGy) on the aluminum alloy 6061 (AA6061-T6) chlorination yield in sulfur monochloride (S 2 Cl 2 ). Our findings indicate that, compared to nonirradiated solvent, radiation-induced changes in the chemical composition of S 2 Cl 2 —identified using Raman spectroscopy—afford an additional, dose-dependent exothermic process prior to the chlorination reaction’s typical thermodynamic behavior. We attribute this new process to reactions involving aluminum species (metal, oxide, or [oxy]hydroxides) and sulfur dichloride (SCl 2 ), an S 2 Cl 2 radiolysis product that accumulates with absorbed gamma dose, but is absent following an AA6061-T6 chlorination study. Despite the exothermicity of this new process, the overall yield of chlorination decreased with increasing preirradiation dose. Consequently, the chemical reactivity, specificity (aluminum metal vs aluminum passivation and corrosion layer constituents), and byproducts of SCl 2 must be more thoroughly evaluated to support the continued development of advanced S 2 Cl 2 chlorination technologies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Csa-19, a radiation-responsive human gene, identified by an unbiased two-gel cDNA library screening method in human cancer cells

A novel polymerase chain reaction (PCR)-based method was used to identify candidate genes whose expression is altered in cancer cells by ionizing radiation. Transcriptional induction of randomly selected genes in control versus irradiated human HL60 cells was compared. Among several complementary DNA (cDNA) clones recovered by this approach, one cDNA clone (CL68-5) was downregulated in X-irradiated HL60 cells but unaffected by 12-O-tetradecanoyl phorbol-13-acetate, forskolin, or cyclosporin-A. DNA sequencing of the CL68-5 cDNA revealed 100% nucleotide sequence homology to the reported human Csa-19 gene. Northern blot analysis of RNA from control and irradiated cells revealed the expression of a single 0.7-kilobase (kb) messenger RNA (mRNA) transcript. This 0.7-kb Csa-19 mRNA transcript was also expressed in a variety of human adult and corresponding fetal normal tissues. Moreover, when the effect of X- or fission neutron-irradiation on Csa-19 mRNA was compared in cultured human cells differing in p53 gene status (p53-/- versus p53+/+), downregulation of Csa-19 by X-rays or fission neutrons was similar in p53-wild type and p53-null cell lines. Our results provide the first known example of a radiation-responsive gene in human cancer cells whose expression is not associated with p53, adenylate cyclase or protein kinase C.

NASA Discipline Radiation Health↗

Beam Test Results of the RADiCAL—A Radiation Hard Innovative EM Calorimeter

High-performance calorimetry conducted at future hadron colliders, such as the FCC-hh, poses a significant challenge for applying current detector technologies due to unprecedented beam luminosities and radiation fields. Solutions include developing scintillators that are capable of separating events at the sub-fifty picosecond level while also maintaining performance after extreme and constant neutron and ionizing radiation exposure. The radiation-hard innovative calorimeter (RADiCAL) is an approach that incorporates radiation tolerant materials in a sampling “shashlik”-style calorimeter configuration, using quartz capillaries filled with organic liquid or polymer-based wavelength shifters embedded in layers of tungsten plates and lutetium-yttrium oxyorthosilicate (LYSO) crystals. Here, this novel design intends to address the priority research directions (PRD) for calorimetry listed in the DOE basic research needs (BRN) workshop for high energy physics (HEP) instrumentation. Here we report preliminary results from an experimental run at the Fermilab Test Beam Facility (FTBF) in June 2022. These tests demonstrate that the RADiCAL concept is capable of ¡50 ps timing resolution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

Purpose: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis—particularly in younger patients—might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiation dose and MBIR in the MDCT assessment of airway WT. Methods: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo{sup TM}, GE Healthcare) were used to reconstruct CT images of the airways. For each kV–mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV–mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV–mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. Results: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Satellite Power System (SPS) microwave subsystem impacts and benefits

The impacts and benefits to society of the microwave subsystem resulting from the developing, construction and operating of a space solar power to earth, electric power delivery system are presented and discussed. The primary benefit (usable energy) is conveyed mainly in the fundamental frequency portion of the RF radiation beam that is intercepted and converted to electric power output. The small fraction of the microwave and other electromagnetic energy that does not end up in the electric utility grid, yields most of the subsystem impacts. The impacts range from harmonics and noise radiated by the transmitting antenna, through potential interference with ionospheric communications and navigation caused by the power beam heating the ionosphere, to the potential large land area requirements for the rectennas and low level microwave radiation around the rectennas. Additional benefits range from a very low level of waste heat liberated and lack of atmospheric emissions including noise while operating to having no residual ionizing radiation from the rectenna when it is deactivated.

Dickinson, R. M.↗

The space radiation environment for electronics

The earth's space radiation environment is described in terms of charged particles as relevant to effects on spacecraft electronics. The nature and magnitude of the trapped and transiting environments are described in terms of spatial distribution and temporal variation. The internal radiation environment of the spacecraft is described in terms of shielding the high-energy particles of the free-field environment. Exposure levels are presented in terms of ionizing radiation dose and particle fluence for comparison to electronic component susceptibility.

Stassinopoulos, E. G.↗