Modal filtering for midinfrared nulling interferometry using single mode silver halide fibers

We demonstrate the modal filtering properties of newly developed single mode silver halide fibers for use at midinfrared wavelengths, centered at 10.5 {mu}m. The goal was to achieve a suppression of nonfundamental modes greater than a factor of 300 to enable the detection and characterization of Earthlike exoplanets with a space-based nulling interferometer. Fiber segments of 4.5 cm, 10.5 cm, 15 cm, and 20 cm lengths were tested. We find that the performance of the fiber was limited not by the modal filtering properties of the core but by the unsuppressed cladding modes present at the output of the fiber. In 10.5 cm and longer sections, this effect can be alleviated by properly aperturing the output. Exclusive of coupling losses, the fiber segments of 10.5-20 cm length can provide power suppression of undesirable components of the input field by a factor of 15000 at least. The demonstrated performance thus far surpasses our requirements, such that even very short sections of fiber provide adequate modal filtering for exoplanet characterization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlated speckle noise in white-light interferometry: theoretical analysis of measurement uncertainty

The partial coherent illumination of the specimen, which is required for white-light interferometric measurements of optically rough surfaces, directly leads to speckle. The electric field of such speckle patterns strongly fluctuates in amplitude and phase. This spatially correlated noise influences the accuracy of the measuring device. Although a variety of noise sources in white-light interferometry has been studied in recent years, they do not account for spatial correlation and, hence, they cannot be applied to speckle noise. Thus, we derive a new model enabling quantitative predictions for measurement uncertainty caused by speckle. The model reveals that the accuracy can be attributed mainly to the degree of spatial correlation, i.e., the average size of a speckle, and to the coherence length of the light source. The same parameters define the signal-to-noise ratio in the spectral domain. The model helps to design filter functions that are perfectly adapted to the noise characteristics of the respective device, thus improving the accuracy of postprocessing algorithms for envelope detection. The derived expressions are also compared to numerical simulations and experimental data of two different types of interferometers. These results are a first validation of the theoretical considerations of this article.

36 MATERIALS SCIENCE↗

Distortion compensation in interferometric testing of mirrors

We present a method to compensate for the imaging distortion encountered in interferometric testing of mirrors, which is introduced by interferometer optics as well as from geometric projection errors. Our method involves placing a mask, imprinted with a regular square grid, over the mirror and finding a transformation that relates the grid coordinates to coordinates in the base plane of the parent surface. This method can be used on finished mirrors since no fiducials have to be applied to the surfaces. A critical step in the process requires that the grid coordinates be projected onto the mirror base plane before the regression is performed. We apply the method successfully during a center-of-curvature null test of an F/2 off-axis paraboloid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Paired circularly polarized heterodyne ellipsometer

We develop a paired circularly polarized heterodyne ellipsometer (PCPHE), in which a heterodyne interferometer based on a two-frequency circularly polarized laser beam is set up. It belongs to an amplitude-sensitive ellipsometer that is able to provide not only a wider dynamic range of polarization modulation frequency but also a higher detection sensitivity than that of a conventional photometric ellipsometer. A real-time and precise measurement of ellipsometric parameters, which demonstrated an accuracy of less than 1 nm on thickness measurement of SiO2 thin film deposited on silicon substrate, can be applied with the PCPHE.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous measurement of linear and transverse displacements by laser self-mixing

We present a contactless optical sensor based on the laser-self-mixing effect for real-time measurement of linear and transverse displacements of a moving stage. The sensor is able to measure linear displacements of up to 400 mm along the main optical axis while simultaneously estimating straightness and flatness deviations up to 1 mm. The sensor exploits two identical coplanar nonparallel self-mixing interferometers and requires only one reference plane. The reduction in the number of optical elements allowed by the self-mixing configuration and the intrinsic stiffness of the adopted geometry result in a compact, low-cost, and easy-to-align setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Echelle spectrograph calibration with a frequency comb based on a harmonically mode-locked fiber laser: a proposal

Details for constructing an astronomical frequency comb suitable as a wavelength reference for echelle spectrographs associated with optical telescopes are outlined. The source laser for the frequency comb is a harmonically mode-locked fiber laser with a central wavelength of 1.56 {mu}m. The means of producing a repetition rate greater than 7 GHz and a peak optical power of {approx}8 kW are discussed. Conversion of the oscillator light into the visible can occur through a two-step process of (i) nonlinear conversion in periodically poled lithium niobate and (ii) spectral broadening in photonic crystal fiber. While not necessarily octave spanning in spectral range to permit the use of an f -to- 2f interferometer for offset frequency control, the frequency comb can be granted accuracy by linking the mode spacing and a comb tooth to separate frequency references. The design avoids the use of a Fabry-Perot cavity to increase the mode spacing of the frequency comb; however, the level of supermode suppression and sideband asymmetry in the fiber oscillator and in the subsequent frequency conversion stages are aspects that need to be experimentally tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suppressing phase errors from vibration in phase-shifting interferometry

A general method for reducing the influence of vibrations in phase-shifting interferometry corrects the surface phase map through a spectral analysis of a ''phase-error pattern,'' a plot of the interference intensity versus the measured phase, for each phase-shifted image. The method is computationally fast, applicable to any phase-shifting algorithm and interferometer geometry, has few restrictions on surface shape, and unlike spatial Fourier methods, high density spatial carrier fringes are not required, although at least a fringe of phase departure is recommended. Over a 100x reduction in vibrationally induced surface distortion is achieved for small amplitude vibrations on real data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10{sup -8} (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subdivision and direction recognition of {lambda}/16 of orthogonal fringes for nanometric measurement

Subdivision is one of the essential methods to improve the measurement resolution of optical instruments. A new method is proposed to solve {lambda}/16 bidirectional subdivision and direction recognition for orthogonal interference signals by constructing two sets of reference signals and using zero-cross detection. The experimental results prove that the method is efficient for orthogonal signals and has good real-time performance by field-programmable gate array realization. This method is easy to realize by use of electronic design automation tools and can be widely used in the signal processing system of optical measurement instruments such as a moire fringe measurement system and laser interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of maximum likelihood reconstruction of subaperture data for measurement of large flat mirrors

Interferometers accurately measure the difference between two wavefronts, one from a reference surface and the other from an unknown surface. If the reference surface is near perfect or is accurately known from some other test, then the shape of the unknown surface can be determined. We investigate the case where neither the reference surface nor the surface under test is well known. By making multiple shear measurements where both surfaces are translated and/or rotated, we obtain sufficient information to reconstruct the figure of both surfaces with a maximum likelihood reconstruction method. The method is demonstrated for the measurement of a 1.6 m flat mirror to 2 nm rms, using a smaller reference mirror that had significant figure error.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavefront reversal technique for self-referencing collimation testing

We present a wavefront reversal technique to produce a dual-field fringe pattern for self-referencing collimation testing in wedge-plate lateral-shear interferometry. The method requires only a suitably placed cubic beam splitter to produce two replicas of the fringe field formed by the wedge-plate lateral-shear interferometer. One of the replicas has a fringe pattern that is the reverse of the other. With these two fringe fields, the collimation testing has a built-in reference, and the detection sensitivity is twice that of a single-wedge-plate technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superheterodyne configuration for two-wavelength interferometry applied to absolute distance measurement

We present a new superheterodyne technique for long-distance measurements by two-wavelength interferometry (TWI). While conventional systems use two acousto-optic modulators to generate two different heterodyne frequencies, here the two frequencies result from synchronized sweeps of optical and radio frequencies. A distributed feedback laser source is injected in an intensity modulator that is driven at the half-wave voltage mode. A radio-frequency signal is applied to this intensity modulator to generate two optical sidebands around the optical carrier. This applied radio frequency consists of a digital ramp between 13 and 15 GHz, with 1 ms duration and with an accuracy of better than 1 ppm. Simultaneously, the laser source is frequency modulated by a current modulation that is synchronized on the radio-frequency ramp as well as on a triangle waveform. These two frequency-swept optical signals at the output of the modulator illuminate a Michelson interferometer and create two distinct distance-dependent heterodyne frequencies on the photodetector. The superheterodyne signal is then detected and bandpass filtered to retrieve the absolute distance measurement. Experiments between 1 and 15 m confirm the validity of this new concept, leading to a distance accuracy of {+-} 50 {mu}m for a 1 ms acquisition time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous measurement of group refractive index and thickness of optical samples using optical coherence tomography

Optical coherence tomography (OCT), based on a Michelson interferometer and utilizing low coherence light as the optical source, is a novel technique for the noninvasive imaging of optical scattering media. A simple OCT scheme based on a 3x3 fiber coupler is presented for the simultaneous measurement of the refractive index and thickness of optical samples. The proposed system enables the refractive index and thickness to be determined without any prior knowledge of the sample parameters and is characterized by a simple and compact configuration, a straightforward measurement procedure, and a low cost. The feasibility of the proposed approach is demonstrated experimentally using BK7 and B270 optical glass samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation on the properties of a laminar grating as a soft x-ray beam splitter

Laminar-type gratings as soft x-ray beam splitters for interferometry are presented. Gold-coated grating beam splitters with 1000 lines/mm are designed for grazing incidence operation at 13.9nm. They are routinely fabricated using electron beam lithography and ion etching techniques. The laminar grating is measured to have almost equal absolute efficiencies of about 20% in the zeroth and -1st orders, which enables a fringe visibility up to 0.99 in the interferometer. The discrepancy of the grating profiles between the optimized theoretical and the experimental results is analyzed according to the comparison of the optimized simulation results and the measurement realization of the grating efficiencies. By a precise control of the grating profile, the grating efficiency in the -1st order and the fringe visibility could be improved to 25% and 1, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of linear displacement by envelope detection with maximum likelihood estimation

We demonstrate in this report an envelope detection technique with maximum likelihood estimation in a least square sense for determining displacement. This technique is achieved by sampling the amplitudes of quadrature signals resulted from a heterodyne interferometer so that the resolution of displacement measurement of the order of {lambda}/10{sup 4} is experimentally verified. A phase unwrapping procedure is also described and experimentally demonstrated and indicates that the unambiguity range of displacement can be measured beyond a single wavelength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated microinterferometric sensor for in-plane displacement measurement

We present an integrated sensor based on a grating interferometer (GI) for in-plane displacement measurement in microregions of large engineering structures. The system concept and design, based on a monolithic version of Czarnek's GI, is discussed in detail. The technology chain of the GI measurement head (MH), including the master fabrication and further replication by means of hot embossing, is described. The numerical analyses of the MH by means of geometric ray tracing and scalar wave propagation are provided. They allow us to determine geometrical tolerance values as well as refractive index homogeneity and nonflatness of MH working surfaces, which provide proper beam guiding. Finally the demonstrative measurement performed with a model of the sensor is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase-locked loop based on machine surface topography measurement using lensed fibers

We present the phase-locked loop (PLL)-based metrology concept using lensed fibers for on-machine surface topography measurement. The shape of a single-mode fiber at the endface was designed using an ABCD matrix method, and two designed lensed fibers--the ball type and the tapered type--were fabricated, and the performance was evaluated, respectively. As a result, the interferometric fringe was not found in the case of the ball lensed fiber, but the machined surface could be measured by utilization of autofocusing and intensity methods. On the other hand, a very clear Fizeau interferometric fringe was observed in the case of the tapered lensed fiber. Its performance was compared with the results of the capacitance sensor and a commercially available white-light interferometer. We confirmed that PLL-based surface profile measurement using the tapered and ball lensed fibers can be applied for on-machine surface topography measurement applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometric measurement of laser heating in praseodymium-doped YAG crystal

Temperature measurement is required for many applications but can be difficult in some cases. Laser heating or cooling studies demand accurate measurements of temperature changes. A Michelson interferometer configuration has been used to investigate laser heating in solids. An analytical formula was derived to estimate the temperature change from the fringe count by taking into account the temperature dependence of the sample length and refractive index. When 115 mW of a focused Ar{sup +} laser beam (488 nm) passes through a Pr{sup 3+}-doped YAG sample, its temperature increased by 11.7{+-}1.0 K along the beam path due to nonradiative relaxation. The power dependence of the fringe count/movement was recorded. The temperature change was estimated by the interferometric method and is in agreement with that measured by a thermocouple.