Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “home performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Seminar 13 - Advanced Methods for Grid Integration of High-Performance Residential Communities

High-performance residential communities such as net-zero energy (NZE) and NZE-ready communities are emerging across the United States as many cities and states have committed to achieve ambitious energy efficiency and renewable energy goals between now and 2050. The achievement of these goals will transform the nation's communities into the holistic paradigms consisting of pervasive solar photovoltaics (PVs) and other renewable distributed energy resources, energy storage and flexible loads. However, integrating residential communities with high PV penetration may bring many challenges to the grid. For example, during many hours of the year, electric power is flowing out of PV-enabled homes and back into the grid. When this happens simultaneously in many nearby homes, distribution feeder voltage can be raised significantly. Intermittent solar power can also cause voltage flickers, leading to potential damages on both distribution feeder and home appliances. Existing solutions, such as PV curtailment, battery storage, and direct load control, are not able to address all the challenges in a cost-effective way. Better understanding is needed on how to deploy rooftop PV, how to predict building loads, and how to coordinate the homes in a community to enhance grid reliability. This seminar consists of four integral presentations that cover different aspects of a solution to these challenges. First, we will present an automated method to identify the best surfaces to deploy PV and size PV according to the PV penetration goals in a community. Second, we will present a streamlined way to create gray-box building models that are suitable for large-scale building-grid co-simulation. Next, we will present a data-driven method to estimate the end-use energy consumption to better coordinate the behind-the-meter resources to reduce utility cost, provide grid services, and improve renewable energy integration. Lastly, we will present a hierarchical control system that integrates the building models and the estimated non-dispatchable loads into the decision-making process to enhance the reliability and resilience of the residential community. Simulation results from an NZE-ready community in Fort Collins, Colorado will be presented in all four presentations and the guidelines on better grid integration of residential communities will be provided.

14 SOLAR ENERGY↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raleigh Housing Authority Duct Sealing Evaluation

In multifamily and attached buildings, manual duct sealing methods are often impractical or very costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques manually applied sealants and injecting a spray sealant (Aeroseal) in combination with some manual sealing were implemented in several low-rise multi-unit buildings in North Carolina. An analysis of the cost and performance of the two methods is presented. Each method was used in 20 housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where a combination of injected spray sealant and manual sealing was used. Some of this difference is likely due to the fact that injected spray sealing reached portions of the duct system that were inaccessible to manual methods. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns, and the air handler. The cost of manually applying sealant ranged from $275 to $511 per unit and for the Aeroseal treated ducts the cost was $700 per unit. Utility bills were collected and compared for 1 year before and after the retrofits for each unit. Energy savings based on utility bills were within 25%-50% of those predicted by the models for most unit types. Utility bill analysis shows 14% and 16% energy savings using the Aeroseal and hand sealing procedures, respectively, in heating season whereas in cooling season, energy savings using Aeroseal and hand sealing were both 16%. Average simple payback based on utility bills was 2.2 years for manual units and 4.7 years for the Aeroseal units. Only 18 of 40 units had usable utility bills. Berkshire Village Court - House Count - 4: Single Story, Hand sealed ducts; Single Story, Aeroseal Ducting; 2-Story, Hand Sealed ducts; 2-Story, Aeroseal ducts Terrace Park Court - House Count - 2: Single Story, Hand sealed ducts; Double Story, Hand sealed ducting Winter Park Court - House Count - 2: Single Story, Hand sealed ducts, Aeroseal sealed ducting; Double Story, Aeroseal ducting

Aeroseal↗

Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler

Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. One common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.

09 BIOMASS FUELS↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the façade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution.This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre Omer↗

2022 Product Commercialization and Market Development Awardee: Bergey Windpower

In 2023, consumers will finance more than 80% of the residential solar energy systems they purchase, which they use as collateral (called "non-recourse loans"). Similar loans are not yet offered to fund distributed wind energy systems. To accelerate deployment of small wind systems, which power individual rural homes and farms, the United States will need to make consumer loans available at reasonable rates with modest downpayments and collateral requirements. A team led by Bergey Windpower Co. is creating new consumer financing options to reduce or eliminate the upfront cash needed to buy distributed wind energy systems. This new financing structure would decrease purchase costs for small wind turbines produced by Bergey Windpower and possibly other manufacturers. Product financing is instrumental in growing wind power market share, clean energy manufacturing, and installation jobs while reducing greenhouse gas emissions. Bergey Windpower's previous Competitiveness Improvement Project (CIP) awards have led to the development of affordable, high-performance wind turbines, microgrids, and components.

CIP↗

Idaho National Laboratory Cultural Resource Management Office FY 2011 Activity Report

The Idaho National Laboratory (INL) Site is home to vast numbers and a wide variety of important cultural resources representing at least a 13,500 year span of human land use in the region. As a federal agency, the Department of Energy, Idaho Operations Office (DOE-ID) has legal responsibility for the management and protection of the resources and has contracted these responsibilities to Battelle Energy Alliance (BEA). The BEA professional staff is committed to maintaining a cultural resource management program that accepts the challenge of preserving INL cultural resources in a manner reflecting their importance in local, regional, and national history. This report is intended as a stand-alone document that summarizes activities performed by the INL Cultural Resource Management Office (CRMO) staff during fiscal year 2011. This work is diverse, far-reaching and though generally confined to INL cultural resource compliance, also includes a myriad of professional and voluntary community activities. This document is intended to be informative to both internal and external stakeholders, serve as a planning tool for future INL cultural resource management work, and meet an agreed upon legal requirement.

99 GENERAL AND MISCELLANEOUS↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the facade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution. This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre↗

Pecan Street Grid Demonstration Program. Final technology performance report

This document represents the final Regional Demonstration Project Technical Performance Report (TPR) for Pecan Street Inc.’s (Pecan Street) Smart Grid Demonstration Program, DE-OE-0000219. Pecan Street is a 501(c)(3) smart grid/clean energy research and development organization headquartered at The University of Texas at Austin (UT). Pecan Street worked in collaboration with Austin Energy, UT, Environmental Defense Fund (EDF), the City of Austin, the Austin Chamber of Commerce and selected consultants, contractors, and vendors to take a more detailed look at the energy load of residential and small commercial properties while the power industry is undergoing modernization. The Pecan Street Smart Grid Demonstration Program signed-up over 1,000 participants who are sharing their home or businesses’s electricity consumption data with the project via green button protocols, smart meters, and/or a home energy monitoring system (HEMS). Pecan Street completed the installation of HEMS in 750 homes and 25 commercial properties. The program provided incentives to increase the installed base of roof-top solar photovoltaic (PV) systems, plug-in electric vehicles with Level 2 charging, and smart appliances. Over 200 participants within a one square mile area took advantage of Austin Energy and Pecan Street’s joint PV incentive program and installed roof-top PV as part of this project. Of these homes, 69 purchased or leased an electric vehicle through Pecan Street’s PV rebate program and received a Level 2 charger from Pecan Street. Pecan Street studied the impacts of these technologies along with a variety of consumer behavior interventions, including pricing models, real-time feedback on energy use, incentive programs, and messaging, as well as the corresponding impacts on Austin Energy’s distribution assets.The primary demonstration site was the Mueller community in Austin, Texas. The Mueller development, located less than three miles from the Texas State Capitol, is a 711-acre LEED Neighborhood Development mixed-use, urban infill redevelopment on the site of Austin’s former airport, currently under development through a public-private project between the City of Austin, and Catellus Austin LLC. Currently, Mueller is less than 50% complete and more than 3,500 people live or work at Mueller. At full build-out, the project will include more than 3 million square feet of commercial and institutional space, more than 13,000 residents from approximately 5,700 single-family and multi-family dwelling units. Figure 1 shows a Google Map image of the Mueller community, zoomed in on the residential streets participating in the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Highly Insulating Windows with a U-value less than 0.6 W/m2K

U.S. households rely primarily on three sources of energy: natural gas, electricity, and fuel oil. In the past several decades, electricity consumption by households has grown dramatically, and a significant portion of electricity used in homes is for lighting. Lighting includes both indoor and outdoor lighting and is found in virtually every household in the United States. In 2001, according to the US Energy Information Administration, lighting accounted for 101 billion kWh (8.8 percent) of U.S. household electricity use. Incandescent lamps, which are commonly found in households, are highly inefficient sources of light because about 90 percent of the energy used is lost as heat. For that reason, lighting has been one focus area to increase the efficiency of household electricity consumption. Windows have several functions, and one of the main functions is to provide a view to the outside. Daylighting is another one of windows main functions and determines the distribution of daylight to a space. Daylighting windows do not need to be transparent, and a translucent daylighting window is sufficient, and often desired, to diffuse the light and make the space more environmentally pleasing. In homes, skylights are one source of daylighting, but skylights are not very energy efficient and are inseparably linked to solar heat gain. In some climates, added solar heat gains from daylighting may be welcome; but in other climates, heat gain must be controlled. More energy efficient skylights and daylighting solutions, in general, are desired and can be designed by insulating them with aerogels. Aerogels are a highly insulating and transparent material in its pure form. The overall objective for this project was to prepare an economical, translucent, fiber-reinforced aerogel insulation material for daylighting applications that is durable for manufacturing purposes. This advanced insulation material will increase the thermal performance of daylighting windows, while satisfying constraints such as durability, cost, user acceptance, size limits, and environmental safety concerns. The energy efficient daylighting window will consist of a translucent and resilient aerogel panel sandwiched between glass panes in double glazed windows. Compared to the best windows available today, the double glazed translucent windows with 1/2-inch aerogel inserts will have a U-value of 1.2 W/m{sup 2} K (0.211 BTU/ft{sup 2} h F) without any coating or low conductivity fill gases. These windows will be more effective than the windows with an Energy Star rating of U-2 W/m{sup 2} K and could be made even more efficient by using low-e coated glass glazings and inert gas fills. This report summarizes the work accomplished on Cooperative Agreement DE-FC26-03NT41950. During this project, Aspen Aerogels made transparent and translucent aerogels from TMOS and TEOS. We characterized the transparency of the aerogels, reinforced the transparent aerogels with fibers and prepared large translucent aerogel panels and blankets. We also conducted an initial market study for energy efficient translucent windows. A lab-scale process was developed that could be scaled-up to manufacture blankets of these translucent aerogels. The large blankets prepared were used to fabricate prototype translucent windows and skylights. The primary goal of this project was to develop transparent, resilient, hydrophobic silica aerogels that have low thermal conductivities (R-10/inch) to be used to produce aerogel insulated double-glazing windows with a U value of 0.6 W/m{sup 2}K. To meet this objective we developed a process and equipment to produce blankets of translucent, hydrophobic aerogel. We focused on silica, organically-modified silica aerogels (Ormosils), and fiber reinforced silica aerogels due to the appreciable expertise in silica sol-gel processing available with the personnel at Aspen Aerogels, and also due to the quantity of knowledge available in the scientific literature. The project was conducted in three budget periods, herein called BP1, BP2 and BP3.

02 PETROLEUM↗

Energy Efficiency and Conservation Block Grant (EECBG): Better Buildings Neighborhood Program Final Report

The Neighbor to Neighbor Energy Challenge (N2N) brought together a consortium of 14 leading clean energy rural, suburban, and low income communities throughout Connecticut. N2N was awarded $4.2 million from the U.S. Department of Energy (DOE) competitive BetterBuildings Neighborhood Program on August 10, 2010 to run a two-year pilot program (plus one year of transition and evaluation) (Award No. EMCBC- 00969-10). N2N tested innovative program models and hypotheses for improving Connecticut’s existing residential energy efficiency programs that are overseen by the ratepayer fund board and administered by CT utilities. N2N’s original goal was to engage 10 percent of households in participating communities to reduce their energy usage by 20 percent through energy upgrades and clean energy measures. N2N planned for customers to complete more comprehensive whole-home energy efficiency and clean energy measures and to achieve broader penetration than existing utility-administered regulated programs. Since this was an ARRA award, we report the following figures on job creation in Table 1. Since N2N is not continuing in its current form, we do not provide figures on job retention. Table 1 N2N Job Creation by Quarter Jobs Created 2010 Q4 6.65 2011 Q1 7.13 2011 Q2 4.98 2011 Q3 9.66 2011 Q4 5.43 2012 Q1 11.11 2012 Q2 6.85 2012 Q3 6.29 2012 Q4 6.77 2013 Q1 5.57 2013 Q2 8.35 2013 Q3 6.52 Total 85.31 The N2N team encountered several gaps in the existing efficiency program performance that hindered meeting N2N’s and DOE’s short-term program goals, as well as the State of Connecticut’s long-term energy, efficiency, and carbon reduction goals. However, despite the slow program start, N2N found evidence of increasing upgrade uptake rates over time, due to delayed customer action of one to two years from N2N introduction to completion of deeper household upgrades. Two main social/behavioral principles have contributed to driving deeper upgrades in CT: 1. Word of mouth, where people share their experience with others, which leads to others to take action; and 2. Self-herding, where people follow past behavior, which leads to deeper and deeper actions within individual households.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Design and Comparative Testing of a Hybrid-Cooled Computer Cluster [Thesis}

With water cooling becoming an affordable option both at home and at scale, it is important to consider the possible benefits over air cooling. There are several methods of liquid cooling, notables include: immersion, cold water cooling, and warm water cooling. The total cost of ownership is difficult to determine with these options as each has a different impact on the data center. Considering retrofit, over a new data center, introduces unforeseen variables that make cost analysis a challenge. Besides the added costs of additional infrastructure, and the cost to remove old, the upfront costs could be daunting. Therefore a cost analysis would be a study of its won. This study however hopes to reveal the resulting tradeoffs in temperature, performance, and power usage presented in the case between classical airflow based heat sink mechanisms to water provided directly at the heatsink. Having control over a discrete chiller will provide answers to the CPU temperatures, power usage, and performance at various inlet water temperatures. To water or to air?

97 MATHEMATICS AND COMPUTING↗

Determining Cs-137 Background Body Burdens for Wild Pigs at Savannah River Site

In Gaines and Novak, an effective method for determining the background 137 Cs body burden for the white-tailed deer population on the SRS was developed, using data collected during public hunts combined with gamma overflight data to determine the areas contaminated by site activities. However, a background 137 Cs body burden for the wild pigs present on the SRS has not been developed to date. In this work, we applied the Gaines and Novak methods to determine the 137 Cs background concentration in wild pigs. The determination of a site-specific home range for wild pigs on SRS with establishing background hunt compartments for calculating the background body burdens of 137 Cs resulted in an upper bound concentration in wild pigs on SRS of 1.97 pCi/g. This value bounds 95% of the possible 137 Cs contamination value for wild pigs from the background compartments with 95% confidence. Therefore, it is recommended that 1.97 pCi/g be used in the SRS Hunter Dose Tracking System as the background 137 Cs concentration for wild pigs on SRS. This concentration should be decay corrected from the year 2014. It is also recommended that this assessment of background concentrations in SRS wild pigs (and whitetailed deer) be performed at least every five years.

59 BASIC BIOLOGICAL SCIENCES↗

Occupancy Simulation in Three Residential Research Houses

Three houses of similar floor plan are being compared for energy consumption. The first house is a typical builder house of 2400 ft2 (223 m2) in east Tennessee. The second house contains retrofits available to a home owner such as energy efficient appliances, windows and HVAC, as well as an insulated attic which contains HVAC duct work. The third house was built using optimum-value framing construction with photovoltaic modules and solar water heating. To consume energy researchers have set up appliances, lights, and plug loads to turn on and off automatically according to a schedule based on the Building America Research Benchmark Definition. As energy efficiency continues to be a focus for protecting the environment and conserving resources, experiments involving whole house energy consumption will be done. In these cases it is important to understand how to simulate occupancy so that data represents only house performance and not human behavior. The process for achieving automated occupancy simulation will be discussed. Data comparing the energy use of each house will be presented and it will be shown that the third house used 66% less and the second house used 36% less energy than the control house in 2010. The authors will discuss how energy prudent living habits can further reduce energy use in the third house by 23% over the average American family living in the same house.

Boudreaux, Philip R↗

A History of High-Performance Computing

Faster than most speedy computers. More powerful than its NASA data-processing predecessors. Able to leap large, mission-related computational problems in a single bound. Clearly, it s neither a bird nor a plane, nor does it need to don a red cape, because it s super in its own way. It's Columbia, NASA s newest supercomputer and one of the world s most powerful production/processing units. Named Columbia to honor the STS-107 Space Shuttle Columbia crewmembers, the new supercomputer is making it possible for NASA to achieve breakthroughs in science and engineering, fulfilling the Agency s missions, and, ultimately, the Vision for Space Exploration. Shortly after being built in 2004, Columbia achieved a benchmark rating of 51.9 teraflop/s on 10,240 processors, making it the world s fastest operational computer at the time of completion. Putting this speed into perspective, 20 years ago, the most powerful computer at NASA s Ames Research Center, home of the NASA Advanced Supercomputing Division (NAS), ran at a speed of about 1 gigaflop (one billion calculations per second). The Columbia supercomputer is 50,000 times faster than this computer and offers a tenfold increase in capacity over the prior system housed at Ames. What s more, Columbia is considered the world s largest Linux-based, shared-memory system. The system is offering immeasurable benefits to society and is the zenith of years of NASA/private industry collaboration that has spawned new generations of commercial, high-speed computing systems.

Source record↗

Spaceport Command and Control System Automated Verification Software Development

For as long as we have walked the Earth, humans have always been explorers. We have visited our nearest celestial body and sent Voyager 1 beyond our solar system1 out into interstellar space. Now it is finally time for us to step beyond our home and onto another planet. The Spaceport Command and Control System (SCCS) is being developed along with the Space Launch System (SLS) to take us on a journey further than ever attempted. Within SCCS are separate subsystems and system level software, each of which have to be tested and verified. Testing is a long and tedious process, so automating it will be much more efficient and also helps to remove the possibility of human error from mission operations. I was part of a team of interns and full-time engineers who automated tests for the requirements on SCCS, and with that was able to help verify that the software systems are performing as expected.

Automation↗

Aerosol Vacuum-Assisted Plasma Ionization (Aero-VaPI) Coupled to Ion Mobility-Mass Spectrometry

In this communication, we report on the real-time analysis of organic aerosol particles by Vacuum-assisted Plasma Ionization-Mass Spectrometry (Aero-VaPI-MS) using a home-built VaPI ion source coupled to a Synapt G2-S HDMS ion mobility-mass spectrometry (IM-MS) system. Standards of organic molecules of interest in prebiotic chemistry were used to generate aerosols. Monocaprin and decanoic acid aerosol particles were successfully detected in both the positive and negative ion modes, respectively. A complex aerosol mixture of different sizes of polymers of L-malic acid was also examined through ion mobility (IM) separations, resulting in the detection of polymers of up to eight monomeric units. This noncommercial plasma ion source is proposed as a low cost alternative to other plasma ionization platforms used for aerosol analysis, and a higher-performance alternative to more traditional aerosol mass spectrometers. VaPI provides robust online ionization of organics in aerosols without extensive ion activation, with the coupling to IM-MS providing higher peak capacity and excellent mass accuracy. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial ecology of translocated raccoons

Raccoons (Procyon lotor) are routinely translocated both legally and illegally to mitigate conflicts with humans, which has contributed to the spread of rabies virus across eastern North America. The movement behavior of translocated raccoons has important ramifications for disease transmission yet remains understudied and poorly quantified. To examine the spatial ecology of raccoons following experimental translocation, we performed reciprocal 16 km-distance translocations of 30 raccoons between habitats of high and low raccoon density (bottomland hardwood and upland pine, respectively) across the Savannah River Site (SRS) in Aiken, South Carolina, USA (2018–2019). Translocation influenced patterns of raccoon space use, with translocated animals exhibiting a 13-fold increase in 95% utilization distributions (UDs) post- compared to pre-translocation (mean 95% UD 35.8 ± 36.1 km 2 vs 1.96 ± 1.17 km 2 ). Raccoons originating from upland pine habitats consistently had greater space use and larger nightly movement distances post-translocation compared to raccoons moved from bottomland hardwood habitats, whereas these differences were generally not observed prior to translocation. Estimated home ranges of male raccoons were twice the area as estimated for female raccoons, on average, and this pattern was not affected by translocation. After a transient period lasting on average 36.5 days (SD = 30.0, range = 3.25–92.8), raccoons often resumed pre-experiment movement behavior, with 95% UD sizes not different from those prior to translocation (mean = 2.27 ± 1.63km 2 ). Most animals established new home ranges after translocation, whereas three raccoons moved > 16 km from their release point back to the original capture location. Four animals crossed a 100-m wide river within the SRS post-translocation, but this behavior was not documented among collared raccoons prior to translocation. Large increases in space use combined with the crossing of geographic barriers such as rivers may lead to elevated contact rates with conspecifics, which can heighten disease transmission risks following translocation. These results provide additional insights regarding the potential impacts of raccoon translocation towards population level risks of rabies outbreaks and underscore the need to discourage mesocarnivore translocations to prevent further spread of wildlife rabies.

59 BASIC BIOLOGICAL SCIENCES↗