Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Linear Collider Test Facility: Twiss Parameter Analysis at the IP/Post-IP Location of the ATF2 Beam Line

At the first stage of the ATF2 beam tuning, vertical beam size is usually bigger than 3 {micro}m at the IP. Beam waist measurements using wire scanners and a laser wire are usually performed to check the initial matching of the beam through to the IP. These measurements are described in this paper for the optics currently used ({beta}{sub x} = 4cm and {beta}{sub y} = 1mm). Software implemented in the control room to automate these measurements with integrated analysis is also described. Measurements showed that {beta} functions and emittances were within errors of measurements when no rematching and coupling corrections were done. However, it was observed that the waist in the horizontal (X) and vertical (Y) plane was abnormally shifted and simulations were performed to try to understand these shifts. They also showed that multiknobs are needed in the current optics to correct simultaneously {alpha}{sub x}, {alpha}{sub y} and the horizontal dispersion (D{sub x}). Such multiknobs were found and their linearity and orthogonality were successfully checked using MAD optics code. The software for these multiknobs was implemented in the control room and waist scan measurements using the {alpha}{sub y} knob were successfully performed.

43 PARTICLE ACCELERATORS↗

Testing of advanced technique for linear lattice and closed orbit correction by modeling its application for iota ring at Fermilab

Many modern and most future accelerators rely on precise configuration of lattice and trajectory. The Integrable Optics Test Accelerator (IOTA) at Fermilab that is coming to final stages of construction will be used to test advanced approaches of control over particles dynamics. Various experiments planned at IOTA require high flexibility of lattice configuration as well as high precision of lattice and closed orbit control. Dense element placement does not allow to have ideal configuration of diagnostics and correctors for all planned experiments. To overcome this limitations advanced method of lattice an beneficial for other machines. Developed algorithm is based on LOCO approach, extended with various sets of other experimental data, such as dispersion, BPM BPM phase advances, beam shape information from synchrotron light monitors, responses of closed orbit bumps to variations of focusing elements and other. Extensive modeling of corrections for a big number of random seed errors is used to illustrate benefits from developed approach.

43 PARTICLE ACCELERATORS↗

Solid phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Solid-phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Scattering effects at near-wall flow measurements using Doppler global velocimetry

Doppler global velocimetry (DGV) is considered to be a useful optical measurement tool for acquiring flow velocity fields. Often near-wall measurements are required, which is still challenging due to errors resulting from background scattering and multiple-particle scattering. Since the magnitudes of both errors are unknown so far, they are investigated by scattering simulations and experiments. Multiple-particle scattering mainly causes a stochastic error, which can be reduced by averaging. Contrary to this, background scattering results in a relative systematic error, which is directly proportional to the ratio of the background scattered light power to the total scattered light power. After applying a correction method and optimizing the measurement arrangement, a subsonic flat plate boundary layer was successfully measured achieving a minimum wall distance of 100 {mu}m with a maximum relative error of 6%. The investigations reveal the current capabilities and perspectives of DGV for near-wall measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom

Purpose: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top. Methods: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system. Results: The phantom positioning was found to be within 0.04 ({sigma}= 0.12) Degree-Sign , 0.02 ({sigma}= 0.13) Degree-Sign , and -0.03 ({sigma}= 0.06) Degree-Sign in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of -0.2({sigma}= 0.4) mm in translational and -0.1({sigma}= 0.1) Degree-Sign in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of -0.3({sigma}= 0.9) mm and -1.4({sigma}= 1.7) Degree-Sign in translational and rotational directions over low resolution images, and this is reduced to -0.1({sigma}= 0.2) mm and -0.1({sigma}= 0.79) Degree-Sign using high resolution images. Conclusions: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3 Degree-Sign in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.

60 APPLIED LIFE SCIENCES↗

A Consistent Representation of Cloud Overlap and Cloud Subgrid Vertical Heterogeneity

Many global climate models underestimate the cloud cover and overestimate the cloud albedo, especially for low-level clouds. We determine how a correct representation of the vertical structure of clouds can fix part of this bias. We use the 1D McICA framework and focus on low-level clouds. Using Large Eddy Simulations results as reference, we propose a method based on exponential-random overlap that represents the cloud overlap between layers and the subgrid cloud properties over several vertical scales, with a single value of the overlap parameter. Starting from a coarse vertical grid, representative of atmospheric models, this algorithm is used to generate the vertical profile of the cloud fraction with a finer vertical resolution, or to generate it on the coarse grid but with subgrid heterogeneity and cloud overlap that ensures a correct cloud cover. Doing so we find decorrelation lengths are dependent on the vertical resolution, except if the vertical subgrid heterogeneity and interlayer overlap are taken into account coherently. We confirm that the frequently used maximum-random overlap leads to a significant error by underestimating the low-level cloud cover with a relative error of about 50%, that can lead to an error of SW cloud albedo as big as 70%. Not taking into account the subgrid vertical heterogeneity of clouds can cause a relative error of 20% in brightness, assuming the cloud cover is correct.

54 ENVIRONMENTAL SCIENCES↗

Magnetic field calculation for a 10 MeV positron emission tomography cyclotron

The magnetic field calculation and correction for a 10 MeV positron emission tomography cyclotron is presented. 3D TOSCA analysis results are compared with the measured data, and the calculation error is used to calibrate the B-H curve to obtain a very precise finite element method estimator, which is used to predict the correction of the magnet pole for achieving the isochronous field. The isochronous field error is approximated with the effects of a set of standard patches. On the assumption that the effect of each small patch is proportional to its surface, the correction of the magnet pole is found by solving a system of equations using the least square scheme. The magnet shimming is performed and the measured magnetic field is found in good agreement with the prediction, with an error less than 2 G.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact adaptive optic-optical coherence tomography system

Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.

47 OTHER INSTRUMENTATION↗

Compact adaptive optic-optical coherence tomography system

Badal Optometer and rotating cylinders are inserted in the AO-OCT to correct large spectacle aberrations such as myopia, hyperopic and astigmatism for ease of clinical use and reduction. Spherical mirrors in the sets of the telescope are rotated orthogonally to reduce aberrations and beam displacement caused by the scanners. This produces greatly reduced AO registration errors and improved AO performance to enable high order aberration correction in a patient eyes.

47 OTHER INSTRUMENTATION↗

Towards operational atmospheric correction of airborne hyperspectral imaging spectroscopy: Algorithm evaluation, key parameter analysis, and machine learning emulators

Atmospheric correction of airborne hyperspectral imaging spectroscopy (AHIS) to obtain high-quality surface reflectance is the prerequisite for remote sensing applications. Over the last decades, different atmospheric correction methods have been developed based on radiative transfer models (RTMs), however, the relative performances of different algorithms are unclear. Automated operational atmospheric correction methods to process large-volume AHIS data in a high-accurate and high-throughput manner are still lacking. Therefore, this study proposed an operational atmospheric correction pipeline for deriving surface reflectance from AHIS data. To ensure the accuracy and efficiency of the pipeline, we focused on three specific aspects: (1) selecting a suitable RTM for the development of atmospheric lookup tables (LUTs) by comparing the commercial MODerate resolution atmospheric TRANsmission (MODTRAN) and open-sourced Library for Radiative TRANsfer (LibRadTRAN) models, where the widely-used software, Atmospheric/Topographic Correction for Airborne Imagery (ATCOR), was used as benchmarks; (2) identifying key atmospheric correction parameters and determining suitable sources for parameter retrievals including AHIS, Moderate Resolution Imaging Spectroradiometer (MODIS), and AErosol RObotic NETwork (AERONET); and (3) testing the performance of using machine learning emulators to speed up the RTM-based atmospheric correction. Results indicate that (1) atmospheric correction based on MODTRAN LUTs can produce surface reflectance accurately with mean absolute errors < 0.05 and cosine similarities > 0.98 compared to field measurements, which is comparable to the software ATCOR and slightly outperforms the LibRadTRAN LUTs; (2) sobol global sensitivity analysis demonstrates that in the atmospheric correction, visibility and water vapor are two key parameters that can be accurately derived from AHIS in contrast to MODIS or AERONET data; and (3) Random Forest emulators can produce accurate estimations of surface reflectance with mean absolute errors < 0.03 and cosine similarities > 0.98 for higher processing efficiency and determine a suitable set of wavelengths for retrieving atmospheric visibility and water vapor. In conclusion, the proposed atmospheric correction pipeline also improved the four-stream radiative transfer theory for airborne applications by considering adjacent effects from airborne surrounding pixels and can also be applied for atmospheric correction of hyperspectral data from spaceborne missions.

47 OTHER INSTRUMENTATION↗

Profiling the molecular destruction rates of temperature and humidity as well as the turbulent kinetic energy dissipation in the convective boundary layer

A simultaneous deployment of Doppler, temperature, and water-vapor lidars is able to provide profiles of molecular destruction rates and turbulent kinetic energy (TKE) dissipation in the convective boundary layer (CBL). Horizontal wind profiles and profiles of vertical wind, temperature, and moisture fluctuations are combined, and transversal temporal autocovariance functions (ACFs) are determined for deriving the dissipation and molecular destruction rates. These are fundamental loss terms in the TKE as well as the potential temperature and mixing ratio variance equations. These ACFs are fitted to their theoretical shapes and coefficients in the inertial subrange. Error bars are estimated by a propagation of noise errors. Sophisticated analyses of the ACFs are performed in order to choose the correct range of lags of the fits for fitting their theoretical shapes in the inertial subrange as well as for minimizing systematic errors due to temporal and spatial averaging and micro- and mesoscale circulations. We demonstrate that we achieve very consistent results of the derived profiles of turbulent variables regardless of whether 1 or 10 s time resolutions are used. We also show that the temporal and spatial length scales of the fluctuations in vertical wind, moisture, and potential temperature are similar with a spatial integral scale of ≈160 m at least in the mixed layer (ML). The profiles of the molecular destruction rates show a maximum in the interfacial layer (IL) and reach values of ϵ m ≃ 7 x 10 -4 g 2 kg −2 s −1 for mixing ratio and ϵ θ ≃ 1.6 x 10 -3 K 2 s −1 for potential temperature. In contrast, the maximum of the TKE dissipation is reached in the ML and amounts to ≃ 10 -2 m 2 s −3 . We also demonstrate that the vertical wind ACF coefficient k w ∝ $\overline{w'^{2}}$ and the TKE dissipation ϵ ∝ ($\overline{w'^{2}}$) 3/2 . For the molecular destruction rates, we show that ϵ m ∝ $\overline{m'^{2}}$ ($\overline{w'^{2}}$) 1/2 and ϵ θ ∝ $\overline{θ'^{2}}$ ($\overline{w'^{2}}$) 1/2 . These equations can be used for parameterizations of ϵ, ϵ m , and ϵ θ . All noise error bars are derived by error propagation and are small enough to compare the results with previous observations and large-eddy simulations. The results agree well with previous observations but show more detailed structures in the IL. Consequently, the synergy resulting from this new combination of active remote sensors enables the profiling of turbulent variables such as integral scales, variances, TKE dissipation, and the molecular destruction rates as well as deriving relationships between them. The results can be used for the parameterization of turbulent variables, TKE budget analyses, and the verification of large-eddy simulations.

dissipation rate↗

Communication: Recovering the flat-plane condition in electronic structure theory at semi-local DFT cost

The flat-plane condition is the union of two exact constraints in electronic structure theory: (i) energetic piecewise linearity with fractional electron removal or addition and (ii) invariant energetics with change in electron spin in a half filled orbital. Semi-local density functional theory (DFT) fails to recover the flat plane, exhibiting convex fractional charge errors (FCE) and concave fractional spin errors (FSE) that are related to delocalization and static correlation errors. We previously showed that DFT+U eliminates FCE but now demonstrate that, like other widely employed corrections (i.e., Hartree-Fock exchange), it worsens FSE. To find an alternative strategy, we examine the shape of semi-local DFT deviations from the exact flat plane and we find this shape to be remarkably consistent across ions and molecules. We introduce the judiciously modified DFT (jmDFT) approach, wherein corrections are constructed from few-parameter, low-order functional forms that fit the shape of semi-local DFT errors. Here we select one such physically intuitive form and incorporate it self-consistently to correct semi-local DFT. We demonstrate on model systems that jmDFT represents the first easy-to-implement, no-overhead approach to recovering the flat plane from semi-local DFT.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-J-32: Dosimetric Evaluation Based On Pre-Treatment Cone Beam CT for Spine Stereotactic Body Radiotherapy: Does Region of Interest Focus Matter?

Purpose: Spine stereotactic body radiotherapy requires very conformal dose distributions and precise delivery. Prior to treatment, a KV cone-beam CT (KV-CBCT) is registered to the planning CT to provide image-guided positional corrections, which depend on selection of the region of interest (ROI) because of imperfect patient positioning and anatomical deformation. Our objective is to determine the dosimetric impact of ROI selections. Methods: Twelve patients were selected for this study with the treatment regions varied from C-spine to T-spine. For each patient, the KV-CBCT was registered to the planning CT three times using distinct ROIs: one encompassing the entire patient, a large ROI containing large bony anatomy, and a small target-focused ROI. Each registered CBCT volume, saved as an aligned dataset, was then sent to the planning system. The treated plan was applied to each dataset and dose was recalculated. The tumor dose coverage (percentage of target volume receiving prescription dose), maximum point dose to 0.03 cc of the spinal cord, and dose to 10% of the spinal cord volume (V10) for each alignment were compared to the original plan. Results: The average magnitude of tumor coverage deviation was 3.9%±5.8% with external contour, 1.5%±1.1% with large ROI, 1.3%±1.1% with small ROI. Spinal cord V10 deviation from plan was 6.6%±6.6% with external contour, 3.5%±3.1% with large ROI, and 1.2%±1.0% with small ROI. Spinal cord max point dose deviation from plan was: 12.2%±13.3% with external contour, 8.5%±8.4% with large ROI, and 3.7%±2.8% with small ROI. Conclusion: A small ROI focused on the target results in the smallest deviation from planned dose to target and cord although rotations at large distances from the targets were observed. It is recommended that image fusion during CBCT focus narrowly on the target volume to minimize dosimetric error. Improvement in patient setups may further reduce residual errors.

60 APPLIED LIFE SCIENCES↗

MAGIC observations and multifrequency properties of the flat spectrum radio quasar 3C 279 in 2011

Aims. We present a study of the very high energy (VHE; E>100 GeV) γ-ray emission of the blazar PKS 1424+240 observed with the MAGIC telescopes. The primary aim of this paper is the multiwavelength spectral characterization and modeling of this blazar, which is made particularly interesting by the recent discovery of a lower limit of its redshift of z ≥ 0.6 and makes it a promising candidate to be the most distant VHE source. Methods. The source has been observed with the MAGIC telescopes in VHE rays for a total observation time of ~33.6 h from 2009 to 2011. A detailed analysis of its γ-ray spectrum and time evolution has been carried out. Moreover, we have collected and analyzed simultaneous and quasi-simultaneous multiwavelength data. Results. The source was marginally detected in VHE rays during 2009 and 2010, and later, the detection was confirmed during an optical outburst in 2011. The combined significance of the stacked sample is ~7.2σ. The differential spectra measured during the different campaigns can be described by steep power laws with the indices ranging from 3.5 ± 1.2 to 5.0 ± 1.7. The MAGIC spectra corrected for the absorption due to the extragalactic background light connect smoothly, within systematic errors, with the mean spectrum in 2009-2011 observed at lower energies by the Fermi-LAT. The absorption-corrected MAGIC spectrum is flat with no apparent turn down up to 400 GeV. The multiwavelength light curve shows increasing flux in radio and optical bands that could point to a common origin from the same region of the jet. The large separation between the two peaks of the constructed non-simultaneous spectral energy distribution also requires an extremely high Doppler factor if an one zone synchrotron self-Compton model is applied. We find that a two-component synchrotron self-Compton model describes the spectral energy distribution of the source well, if the source is located at z ~ 0.6.

79 ASTRONOMY AND ASTROPHYSICS↗

MAGIC long-term study of the distant TeV blazar PKS 1424+240 in a multiwavelength context

Aims. We present a study of the very high energy (VHE; E>100 GeV) γ-ray emission of the blazar PKS 1424+240 observed with the MAGIC telescopes. The primary aim of this paper is the multiwavelength spectral characterization and modeling of this blazar, which is made particularly interesting by the recent discovery of a lower limit of its redshift of z ≥ 0.6 and makes it a promising candidate to be the most distant VHE source. Methods. The source has been observed with the MAGIC telescopes in VHE rays for a total observation time of ~33.6 h from 2009 to 2011. A detailed analysis of its γ-ray spectrum and time evolution has been carried out. Moreover, we have collected and analyzed simultaneous and quasi-simultaneous multiwavelength data. Results. The source was marginally detected in VHE rays during 2009 and 2010, and later, the detection was confirmed during an optical outburst in 2011. The combined significance of the stacked sample is ~7.2σ. The differential spectra measured during the different campaigns can be described by steep power laws with the indices ranging from 3.5 ± 1.2 to 5.0 ± 1.7. The MAGIC spectra corrected for the absorption due to the extragalactic background light connect smoothly, within systematic errors, with the mean spectrum in 2009-2011 observed at lower energies by the Fermi-LAT. The absorption-corrected MAGIC spectrum is flat with no apparent turn down up to 400 GeV. The multiwavelength light curve shows increasing flux in radio and optical bands that could point to a common origin from the same region of the jet. The large separation between the two peaks of the constructed non-simultaneous spectral energy distribution also requires an extremely high Doppler factor if an one zone synchrotron self-Compton model is applied. We find that a two-component synchrotron self-Compton model describes the spectral energy distribution of the source well, if the source is located at z ~ 0.6.

79 ASTRONOMY AND ASTROPHYSICS↗