Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “environmental testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Package Development for Reliability Testing of Perovskites

Metal halide perovskite solar cells have reached a critical point in their development. At a current certified record efficiency of 25.7% for a single-junction, research-scale cell, they now garner serious attention from the solar cell industry as a promising route to widespread, low-cost photovoltaics in single- or tandem-junction configurations. However, more work to demonstrate their durability under real-world outdoor test conditions is necessary to ensure the long-term success and deployment of the technology. Differences in chemistry, processes, and their combination result in unique performance limiters for both efficiency and stability. Further, as many active formulations and layer/cell stack combinations are sensitive to temperature, air, and moisture, it is important to separate intrinsic limitations to stability relative to these extrinsic sources. This presents a particular need for the development of an appropriate and reliable package for environmental (i.e., accelerated and outdoor) testing that will permit these different factors to be evaluated and understood.

14 SOLAR ENERGY↗

JGI Plant Gene Atlas: an updateable transcriptome resource to improve functional gene descriptions across the plant kingdom

Abstract Gene functional descriptions offer a crucial line of evidence for candidate genes underlying trait variation. Conversely, plant responses to environmental cues represent important resources to decipher gene function and subsequently provide molecular targets for plant improvement through gene editing. However, biological roles of large proportions of genes across the plant phylogeny are poorly annotated. Here we describe the Joint Genome Institute (JGI) Plant Gene Atlas, an updateable data resource consisting of transcript abundance assays spanning 18 diverse species. To integrate across these diverse genotypes, we analyzed expression profiles, built gene clusters that exhibited tissue/condition specific expression, and tested for transcriptional response to environmental queues. We discovered extensive phylogenetically constrained and condition-specific expression profiles for genes without any previously documented functional annotation. Such conserved expression patterns and tightly co-expressed gene clusters let us assign expression derived additional biological information to 64 495 genes with otherwise unknown functions. The ever-expanding Gene Atlas resource is available at JGI Plant Gene Atlas (https://plantgeneatlas.jgi.doe.gov) and Phytozome (https://phytozome.jgi.doe.gov/), providing bulk access to data and user-specified queries of gene sets. Combined, these web interfaces let users access differentially expressed genes, track orthologs across the Gene Atlas plants, graphically represent co-expressed genes, and visualize gene ontology and pathway enrichments.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Pre- and Post-Coat Processing on the Fatigue Life of Coated Disk Alloys

Increasing temperatures in aero gas turbines is resulting in oxidation and hot corrosion attack of turbine disks. Since disks are sensitive to low cycle fatigue (LCF), any environmental attack, and especially hot corrosion pitting, can seriously degrade the life of the disk. Application of metallic coatings is one means of protecting disk alloys from this environmental attack. However, since LCF is sensitive to surface conditions, pre- and post-coat processing can have a significant effect on the LCF life of coated bars. Various pre-and post-coating conditions were examined with a Ni-45wt. Cr coating applied by High-power impulse magnetron sputtering (HiPiMS) to a Ni-based disk alloy. Initial pre-coat surface conditions examined a grit blasted surface. Later pre-coat surface treatments involved wet blasting, two shot peening levels (8N-200 and 16N-200) and a highly polished surface. Post-coat treatments involved two shot peening levels (4N-100 and 16N-200) and a post-coat diffusion anneal in high purity Ar or a low PO2 environment to encourage chromia scale formation. Half of the coated and uncoated bars were LCF tested at 760C without further environmental exposure to evaluate the pre- and post-coat treatments. The second half of samples were either oxidized for 500 hours at 760C in air, hot corroded for 50 hours at 760C in air using a Na2SO4-MgSO4 salt, or subjected to both exposures. Results of the LCF testing and post-test characterization of the various coatings will be presented and future research directions discussed.

LCF Life↗

Achieving the End State for the Pahute Mesa Corrective Action Units at the Nevada National Security Site - 20355

Underground nuclear testing at the Nevada National Security Site (NNSS) ended in 1992. To address the impact of radionuclide contamination from underground nuclear testing on the groundwater resources of Nevada, the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program created the Underground Test Area (UGTA) activity to characterize the radionuclides in groundwater, understand the nature and extent of radionuclide migration, and forecast the distribution of radionuclides in groundwater for 1,000 years. The UGTA activity is regulated by the Federal Facility Agreement and Consent Order (FFACO), an agreement negotiated between the Nevada Division of Environmental Protection (NDEP), DOE, and the U.S. Department of Defense (DoD). DOE is close to achieving the end state (closure in place with monitoring and institutional control) for three of the five UGTA corrective action units (CAUs) on the NNSS. A number of challenges remain to achieve the end state of the other two CAUs, both located on Pahute Mesa. Pahute Mesa was the location of 82 underground nuclear tests, less than 10% of the total number of tests on the NNSS. Yet, Pahute Mesa contains slightly more than 60% of the total radionuclides (in curies). Based on groundwater sampling in monitoring wells, two radionuclide plumes have migrated several kilometers (km) in groundwater from selected test cavities and have crossed the boundary of the NNSS (yet remain within the boundaries of Federally controlled land). The path to achieve the end state continues to evolve as more data are collected and a better understanding of radionuclide migration in groundwater is developed. DOE has invested in drilling and sampling more than 50 characterization and monitoring groundwater wells over the past 25 years. The data indicate that the primary radionuclide of concern is tritium as it is about 89% of the total radionuclide inventory (in curies). As well, only tritium has been measured in groundwater outside of cavities at concentrations exceeding the Safe Drinking Water Act (SDWA) standard. For one of the tritium plumes that has migrated across the NNSS boundary, the average rate of migration has been measured as about 45 meters (m) per year with the rate of migration at the leading edge of the plume of about 85 meters per year. At that rate of migration, the tritium plume will decay to safe levels and not reach the publicly accessible environment at concentrations above the SDWA standard. Other radionuclides, at concentrations below the SDWA standards, will be monitored to ensure they remain at safe levels. Consequently, the end state path forward for Pahute Mesa has evolved to take full advantage of the data from the monitoring network to constrain uncertainty in model forecasts and to reduce reliance on probabilistic simulations. The focus of the end state approach relies on developing a monitoring well network that is protective of human health by increasing confidence that no radionuclide plume in the groundwater will migrate undetected to the accessible environment, located about 22 km from the nearest up-gradient underground nuclear test. Using the measured data to remove uncertainty, the evaluation of radionuclide migration from Pahute Mesa is directed toward meeting the goals of the end state. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Theory for the Balance between Warm Rain and Ice Crystal Processes of Precipitation in Mixed-Phase Clouds

Abstract Mixed-phase clouds contain both supercooled cloud liquid and ice crystals. In principle, precipitation may be initiated either by the liquid phase or by the ice phase. Ice crystals may grow by vapor diffusion to become snow (“ice crystal process”), forming “cold” precipitation. Equally, cloud droplets, when large enough, coalesce to form “warm” precipitation by the “warm rain process.” Warm rain could be supercooled and freeze as “warm” graupel. In the present paper, a new simplified theoretical analysis is provided to examine the microphysical system consisting of three species of hydrometeor, namely, cloud liquid, “cold ice” (crystals, snow), and “warm rain” (frozen or supercooled). This is obtained by nondimensionalizing and simplifying the evolution equations for the mass of each species. Analytical formulas are given for equilibria. Feedback analysis shows that the sign of the feedback is linked to the abundance of precipitation, with a neutral surface in the 3D phase space. The system’s precipitation amount explodes while in the initial unstable regime, crossing the neutral surface and approaching the equilibrium point that is a stable attractor. Positive and negative feedbacks are elucidated. In a standard case, the cold ice mass is about 1000 times larger than the warm rain mass. To illustrate the physical behavior of the theory, sensitivity tests are performed with respect to environmental conditions (e.g., aerosol, updraft speed) and microphysical parameters (e.g., riming and sedimentation rates for cold ice). Cold ice prevails, especially in fast ascent, due to its low bulk density, favoring slow sedimentation and a wide cross-sectional area for riming. Significance Statement The theory elucidates how the ice phase can prevail in the precipitation from any mixed-phase clouds with supercooled cloud liquid and crystals. The ice phase radically suppresses cloud liquid by riming when active and “wins” the competition against coalescence. This prevalence of ice is shown to arise from the low bulk density of snow. The cloud is viewed as a system of negative and positive feedbacks that prevail in realms of stability and instability in a 3D phase space.

Meteorology & Atmospheric Sciences↗

Database of pharmacokinetic time-series data and parameters for 144 environmental chemicals

Time courses of compound concentrations in plasma are used in chemical safety analysis to evaluate the relationship between external administered doses and internal tissue exposures. This type of experimental data is rarely available for the thousands of non-pharmaceutical chemicals to which people may potentially be unknowingly exposed but is necessary to properly assess the risk of such exposures. In vitro assays and in silico models are often used to craft an understanding of a chemical’s pharmacokinetics; however, the certainty of the quantitative application of these estimates for chemical safety evaluations cannot be determined without in vivo data for external validation. To address this need, we present a public database of chemical time-series concentration data from 567 studies in humans or test animals for 144 environmentally-relevant chemicals and their metabolites (187 analytes total). All major administration routes are incorporated, with concentrations measured in blood/plasma, tissues, and excreta. We also include calculated pharmacokinetic parameters for some studies, and a bibliography of additional source documents to support future extraction of time-series. In addition to pharmacokinetic model calibration and validation, these data may be used for analyses of diferential chemical distribution across chemicals, species, doses, or routes, and for meta-analyses on pharmacokinetic studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of copper slag blast media for railcar maintenance

Copper slag was tested as a blasting substitute for zirconium silicate which is used to remove paint from railroad cars. The copper slag tested is less costly, strips paint faster, is produced near the point of need, provides a good bonding surface for paint, and permits the operator to work in a more comfortable position, i.e., standing nearly erect instead of having to crouch. Outdoor blasting with the tested Blackhawk (20 to 40 mesh) copper slag is also environmentally acceptable to the State of Utah. Results of tests for the surface erosion rate with copper slag blasting are included.

Sagers, N. W.↗

Electrochemical Technology for Oxygen Removal and Measurement in the CELSS Test Facility, Engineering Development Unit

The Life Support Flight Program is evaluating regenerative technologies, including those that utilize higher plants, as a means to reduce resupply over long duration space missions. Constructed to assist in the evaluation process is the CELSS Test Facility Engineering Development Unit (CTF-EDU) an environmentally closed (less than 1% mass and thermal leakage) technology test bed. This ground based fully functional prototype is currently configured to support crop growth, utilizing the power, volume and mass resources allocated for two space station racks. Sub-system technologies were selected considering their impact on available resources, their ability to minimize integration issues, and their degree of modularity. Gas specific mass handling is a key sub-system technology for both biological and physical/chemical life support technologies. The CTF-EDU requires such a system to accommodate non-linear oxygen production from crops, by enabling the control system to change and sustain partial pressure set points in the growth volume. Electrochemical cells are one of the technologies that were examined for oxygen handling in the CTF-EDU. They have been additionally considered to meet other regenerative life support functions, such as oxygen generation, the production of potable water from composite waste streams, and for having the potential to integrate life support functions with those of propulsion and energy storage. An oxygen removal system based on an electrochemical cell was chosen for the EDU due to it's low power, volume and mass requirements (10W, 0.000027 cu m, 4.5 kg) and because of the minimal number of integration considerations. Unlike it's competitors, the system doesn't require post treatments of its byproducts, or heat and power intensive regenerations, that also mandate system redundancy or cycling. The EDUs oxygen removal system only requires two resources, which are already essential to controlled plant growth: electricity and water. Additionally, the amount of oxygen that is removed from the EDU is directly proportional to the cell input current via Faraday's constant, potentially allowing for a mol/electron measurement of photosynthetic rate. The currently operative oxygen removal system has maintained reduced oxygen set points within the EDU, and preparation is underway to verify of the accuracy of electrochemical measurement of oxygen production and hence, photosynthesis. This paper examines the working principles of the electrochemical cell, outlines the overall design of the oxygen removal system and its integration with other EDU subsystems, and summarizes test results obtained over crop growth cycles in the CTF-EDU.

Drews, Michael E.↗

Spacecraft separation systems mechanisms: Characteristics/performance during high altitude flight test from NASA Wallops Station, Va.

The applications of various separation mechanisms to meet flight mission goals within the physical and environmental constraints of a single stage rocket test vehicle are considered. Each separation concept was selected from the numerous choices available on the basis of its unique requirement and the flight test vehicle incorporated several different concepts. Attention to specific requirements and thoroughness in design and testing were essential to success since there is no specific single answer to separation problems.

Pride, J. D.↗

Exploration Extravehicular Mobility Unit (xEMU) Helmet and Extravehicular Visor Assembly (EVVA) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU helmet and extravehicular visor assembly (EVVA). Two helmets/EVVAs were tested simultaneously in Chamber B, with different thermal environments and EVVA configurations. For the helmet/EVVA on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs, with four different visor and shade configurations. For the helmet/EVVA on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing, with a single visor and shade configuration. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. The thermal effects of the Exploration Informatics (xINFO) lights and camera on the helmet/EVVA was also tested. Twenty-two temperature sensors were used to collect data in critical locations in the xEMU helmet/EVVA assembly. This paper will document the testing results and compare the test data against the xEMU helmet/EVVA and system-level thermal models for model validation.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Lunar Boot Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU lunar boots. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. This paper will address only the cold environment testing results. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through a heater cage surrounding the boots. Notably, the xEMU boots also contacted the liquid-nitrogen chilled floor inside of Chamber B, which provided a conduction pathway to simulate the thermal effects of the lunar surface. Test hardware was developed to extend the water tubing from the Liquid Cooling Ventilation Garment (LCVG) into the boots to set the internal thermal boundary nominally provided by the astronaut’s foot. Thirty-three temperature sensors were used to collect data in critical locations in the xEMU boot assembly as well as for calorimetry to determine heat flux to and from the boots. This paper will document the testing results and provide a high-level interpretation of the testing results. To conclude, this paper will address possible forward work and knowledge gaps present in lunar boot thermal performance and testing.

xEMU↗

Exploration Extravehicular Mobility Unit (xEMU) Hard Upper Torso (HUT) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU hard upper torso (HUT). Two HUTs, one composite HUT and one aluminum HUT, were tested simultaneously in Chamber B, with different thermal environments. For the aluminum HUT on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs. For the composite HUT on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. Seventy-two temperature sensors were used to collect data in critical locations in the xEMU HUT assembly. This paper will document the testing results and compare the test data against the xEMU HUT and system-level thermal models for model validation.

xEMU↗

Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada, Revision 2

The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102), which are currently in the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) stage of the Federal Facility Agreement and Consent Order (FFACO) UGTA Strategy. The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in the Federal Facility Agreement and Consent Order Nevada National Security Site Use Restriction Management Plan (DOE/EMNV, 2024a). The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b).

54 ENVIRONMENTAL SCIENCES↗

Characterizing Hazardous Gases from NMC811 Materials and Coin Cells with TGA and Tube-Furnace FTIR-MS Evolved-Gas-Analysis

Abuse testing is useful for informing the risks of different battery chemistries but has been limited to larger formats. This paper conducted thermal abuse tests at the smaller coin cell level to determine its relevance in specifying vent gas flammability and toxicity. A nitrogen purge carried the evolved gases into a parallel Fourier-transform infrared spectrometer (FTIR) and a mass spectrometer (MS) downstream of the tube furnace. The experimental system was validated by comparing evolved gas data for single components between the tube furnace system and a thermogravimetric analysis (TGA) instrument. Multiple samples were tested during validation, including CaCO3, electrolyte, delithiated NMC 811 cathode, and lithiated graphite anode. Temperature-resolved gas evolution of HF, CO2, CO, H2, and hydrocarbons from isolated components helped to characterize the emission sources. A previously unreported H2 generation mechanism was found. It was shown that the reduced NMC cathode acts as a catalyst to crack polypropylene-decomposed hydrocarbons into H2 at around 450 degrees C. It was also shown, while studying LiPF6 thermal decomposition, that using the tube furnace with a coin cell casing as the sample holder has some advantages for evolved-gas analysis of environmentally sensitive samples relative to testing in TGA instruments. After validation with single components, a fully charged NMC 811 coin cell was failed in the tube furnace. The measured evolved gases were found to be a combination of the species measured from the single component tests. H2 formation related to the reduced cathode was found to have greater abundance than H2 formed from the anode. Hydrogen fluoride emission factors and diethyl carbonate conversion emission factors assist in understanding the gaseous hazards for larger format cells.

25 ENERGY STORAGE↗

ECLSS regenerative systems comparative testing and subsystem selection

In support of Space Station Freedom Phase C/D Environmental Control and Life Support Systems (ECLSS) regenerative systems development, comparative testing was performed on predevelopment hardware of competing technologies for each regenerative function. The purpose of the test program was to collect data on latest generation hardware in order to make final technology selections for each subassembly in the oxygen recovery and water reclamation strings. This paper discusses the testing performed, test results, and evaluation of these results relative to subsystem selections for CO2 reduction, O2 generation, potable water processing, hygiene water processing, and urine processing.

Carasquillo, Robyn L.↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

Lisagor, W. B.↗