Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A Decision Support Framework for Grid-Aware Electric Bus Charge Scheduling

While there are many advantages to electric public transit vehicles, they also pose new challenges for fleet operators. One key challenge is defining a charge scheduling policy that minimizes operating costs and power grid disruptions while maintaining schedule adherence. An uncoordinated policy could result in some buses running out of charge before completing their trip, while a grid agnostic policy might incur higher energy costs or cause an adverse impact on the grid’s distribution system. We present a grid aware decision-theoretic framework for electric bus charge scheduling that accounts for energy price, grid load, and bus status. The framework connects environmental models for traffic (SUMO) and the electric grid (GridLAB-D) to a planner, which evaluates bus charging decisions with regard to their long-term effect on grid reliability and cost. The framework has been evaluated on a simulation of Richland, WA’s bus and grid network, and compared to greedy methods.

EV, machine leaning, EV-Grid, Transportation, Grid↗

Categorizing Plug Load Solutions by Ease of Implementation

Plug loads account for a growing share of U.S. commercial building electricity use, projected to rise from 16% today to 21% by 2050. Managing these loads presents a substantial opportunity for reducing energy costs while providing additional operational benefits, such as improved asset management and occupant comfort. Despite their potential, plug loads are numerous, diverse, and highly occupant-dependent, making control challenging. This publication organizes plug load control strategies by level of effort, offering building owners and operators a staged approach to implement interventions ranging from smart outlets and automatic receptacle controls to behavioral strategies. By following these actionable steps, building stakeholders can reduce energy consumption, lower utility bills, and realize broader operational advantages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Evaluation of the Water Heater Load Potential for Providing Regulation Service

This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users’ water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of heat loads from mitigated and unmitigated vertical displacement events in DIII-D

Experiments have been conducted on the DIII-D tokamak to study the distribution and repeatability of heat loads and vessel currents resulting from vertical displacement events (VDEs). For unmitigated VDEs, the radiated power fraction appears to be of order 50%, with the remaining power dominantly conducted to the vessel walls. Shot-to-shot scatter in heat loads measured at one toroidal location is not large (<±50%), suggesting that toroidal asymmetries in conducted heat loads are not large. Conducted heat loads are clearly observed during the current quench (CQ) of both mitigated and unmitigated disruptions. Significant poloidal asymmetries in heat loads and radiated power are often observed in the experiments but are not yet understood. Energy dissipated resistively in the conducting walls during the CQ appears to be small (<5%). The mitigating effect of neon massive gas injection (MGI) as a function of MGI trigger delay has also been studied. Improved mitigation is observed as the MGI trigger delay is decreased. For sufficiently early MGI mitigation, close to 100% radiated energy and a reduction of roughly a factor 2 in vessel forces is achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Effect of Prosumer Duality on Power Market: The Effect of Market Regulation

Electricity prosumers are energy subsystems that not only consume, but also produce electricity. They are present in distribution level networks as traditional utility customers who have installed distributed energy resources. They are also present in transmission level networks as large conglomerates own both generation assets and large industrial loads. Previous work on the economics of prosumers has demonstrated that prosumers in a market have incentives to behave more competitively compared to producers and consumers in traditional markets. This paper further explores the behavior of prosumers and their response to market policies including the allocation of network losses and the impact of net metering. We extend a Cournot model of a dual prosumer and find that prosumers respond with higher supply quantities if network losses are allocated to demand base. They respond with lower supply quantities if network losses are allocated to supply base. Allocating network losses to demand base also causes equilibrium prices to decline. Markets where prosumers first satisfy their own load and then sell the balance of electricity to the grid have lower quantities and higher prices compared to markets where prosumers buy and sell at locational marginal price.

Tsybina, Eve↗

Heat load of a P-doped GaAs photocathode in SRF electron gun

Many efforts were made over the last decades to develop a better polarized electron source for the high energy physics. Several laboratories operate DC guns with the Gallium-Arsenide photo-cathode, which yield a highly polarized electron beam. However, the beam's emittance might well be improved using a Superconducting RF electron gun, which delivers beams of higher brightness than DC guns does, because the field gradient at the cathode is higher. SRF guns with metal cathodes and CsTe cathodes have been tested successfully. To produce polarized electrons, a Gallium-Arsenide photo-cathode must be used: an experiment to do so in a superconducting RF gun is under way at BNL. Since the cathode will be normal conducting, the problem about the heat load stemming from the cathode arises. We present our measurements of the electrical resistance of GaAs at cryogenic temperatures, a prediction of the heat load and the verification by measuring the quality factor of the gun with and without cathode.

43 PARTICLE ACCELERATORS↗

Direct observation of active material interactions in flowable electrodes using X-ray tomography

Understanding electrical percolation and charging mechanisms in electrochemically active biphasic flowable electrodes is critical for enabling scalable deionization (desalination) and energy storage. Flowable electrodes are dynamic material systems which store charge (remove ions) and have the ability to flow. This flow process can induce structural changes in the underlying material arrangement and result in transient and non-uniform material properties. Carbon-based suspensions are opaque, multi-phase, and three dimensional, and thus prior characterization of the structural properties has been limited to indirect methods (electrochemical and rheology). Herein, a range of mixed electronic and ionically conducting suspensions are evaluated to determine their static structure, function, and properties, utilizing synchrotron radiation X-ray tomographic microscopy (SRXTM). The high brilliance of the synchrotron light enables deconvolution of the liquid and solid phases. Reconstruction of the solid phase reveals agglomeration cluster volumes between 10 μm 3 and 10 3 μm 3 (1 pL) for low loaded samples (5 wt% carbon). The largest agglomeration cluster in the low loaded sample (5 wt%) occupied only 3% of the reconstructed volume whereas samples loaded with 10 wt% activated carbon demonstrated electrically connected clusters that occupied 22% of the imaged region. The highly loaded samples (20 wt%) demonstrated clusters of the order of a microliter, which accounted for 63–85% of the imaged region. These results demonstrate a capability for discerning the structural properties of biphasic systems utilizing SRXTM techniques, and show that discontinuity in the carbon particle networks induces decreased material utilization in low-loaded flowable electrodes.

catalysis (heterogeneous)↗

GLASS FORMULATION DEVELOPMENT AND TESTING FOR COLD CRUCIBLE INDUCTION MELTER (CCIM) ADVANCED REMEDIATION TECHNOLOGIES DEMONSTRATION PROJECT - 9208

Over the past few years, Cold Crucible Induction Melter (CCIM) demonstrations have been completed using SRS sludge batches 2, 3 and 4 (SB2, SB3 and SB4) simulant compositions. These campaigns demonstrated the ability of the CCIM to effectively produce quality glasses at high waste loadings. The current Advanced Remediation Technology (ART) Phase II-A Project is aimed at demonstrating the CCIM technology under representative DWPF flowsheet conditions and to demonstrate extended operations of the melter. A glass composition development effort was completed to identify and recommend a frit composition and sludge batch 4 (SB4) simulant waste loading target for subsequent ART-Phase II-A CCIM demonstration testing. Based on the results of the glass formulation testing, it was recommended that the Frit 503-R6 composition (B{sub 2}O{sub 3} = 14 wt %; Li{sub 2}O = 9 wt %; Na{sub 2}O = 3 wt %; and SiO{sub 2} = 74 wt %) be utilized for the demonstration. Furthermore, a waste loading of 46 wt % was recommended. The recommended frit and waste loading would produce a glass with acceptable durability with a liquidus temperature adequately below the 1250 C nominal CCIM operating temperature. This frit composition and waste loading was found to result in a glass that met CCIM processing requirements for viscosity, electrical conductivity and thermal conductivity. The recommended frit and waste loading level should also provide a buffer for sludge product compositional variation to support the Phase II-A CCIM demonstration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A self diagnostic system for piezoelectric sensors

A technique for determining the mounting conditions of a piezoelectric accelerometer is presented. This technique electrically stimulates the piezoelectric element in the 'diagnostic' frequency band measuring the electrical frequency response characteristics across a capacitive load impedance. The diagnostic frequency band is tipically much higher than the operating bandwidth of the accelerometer. The resonant frequencies of the accelerometer are included in the diagnostic band. By monitoring the shift in these resonant frequencies, via electrical stimulation techniques, certain diagnostic conditions including mounting conditions can be determined. Experimental data from a compression mode accelerometer is used to demonstrate this technique.

Atherton, William J.↗

Experimental Evaluation of Load Rejection Over-Voltage from Grid-Tied Solar Inverters

This paper investigates the impact of load rejection over-voltage (LRO) from commercially available grid-tied photovoltaic (PV) solar inverters. LRO can occur when a local feeder or breaker opens and the power output from a distributed energy resource exceeds the load power. Simplified models of current controlled inverters can over-predict over-voltage magnitudes, thus it is useful to quantify testing. The load rejection event was replicated using a hardware testbed at the National Renewable Energy Laboratory (NREL), and a set of commercially available PV inverters was tested to quantify the impact of LRO for a range of generation-to-load ratios. The magnitude and duration of the over-voltage events are reported in this paper along with a discussion of characteristic inverter output behavior. The results for the inverters under test showed that maximum over-voltage magnitudes were less than 200 percent of nominal voltage, and much lower in many test cases. These research results are important because utilities that interconnect inverter-based DER need to understand their characteristics under abnormal grid conditions.

14 SOLAR ENERGY↗

Time-Varying Value of Energy Efficiency in Michigan

Quantifying the time-varying value of energy efficiency is necessary to properly account for all of its benefits and costs and to identify and implement efficiency resources that contribute to a low-cost, reliable electric system. Historically, most quantification of the benefits of efficiency has focused largely on the economic value of annual energy reduction. Due to the lack of statistically representative metered end-use load shape data in Michigan (i.e., the hourly or seasonal timing of electricity savings), the ability to confidently characterize the time-varying value of energy efficiency savings in the state, especially for weather-sensitive measures such as central air conditioning, is limited. Still, electric utilities in Michigan can take advantage of opportunities to incorporate the time-varying value of efficiency into their planning. For example, end-use load research and hourly valuation of efficiency savings can be used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service (KEMA 2012). In addition, accurately calculating the time-varying value of efficiency may help energy efficiency program administrators prioritize existing offerings, set incentive or rebate levels that reflect the full value of efficiency, and design new programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plug-Load Control and Behavioral Change Research in GSA Office Buildings

The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biopower Technical Strategy Workshop Summary Report

Biopower is electricity produced from a wide range of biomass (organic materials found in wood, plants, agricultural waste and other materials). Biomass is a base load renewable energy source with high availability for electricity production. To explore opportunities for biopower in the United States, the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy Biomass Program conducted the Biopower Technical Strategy Workshop in Denver, Colorado, on December 2–3, 2009. This report summarizes the results of the workshop, which focused on challenges to the expanded use of biopower and the possible solutions, including technology research, development, and demonstration (RD&D) as well as policies and other market transformation mechanisms.

biomass↗

The Role of Instrumentation and Control Technology in Enabling Deployment of Small Modular Reactors

The development of deployable small modular reactors (SMRs) will provide the United States with another economically viable energy option, diversify the available nuclear power alternatives for the country, and enhance U.S. economic competitiveness by ensuring a domestic capability to supply demonstrated reactor technology to a growing global market for clean and affordable energy sources. Smaller nuclear power plants match the needs of much of the world that lacks highly stable, densely interconnected electrical grids. SMRs can present lower capital and operating costs than large reactors, allow incremental additions to power generation capacity that closely match load growth and support multiple energy applications (i.e., electricity and process heat). Taking advantage of their smaller size and modern design methodology, safety, security, and proliferation resistance may also be increased. Achieving the benefits of SMR deployment requires a new paradigm for plant design and management to address multi-unit, multi-product-stream generating stations. Realizing the goals of SMR deployment also depends on the resolution of technical challenges related to the unique characteristics of these reactor concepts. This paper discusses the primary issues related to SMR deployment that can be addressed through crosscutting research, development, and demonstration involving instrumentation and controls (I&C) technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Role of Instrumentation and Controls Technology in Enabling Deployment of Small Modular Reactors

The development of deployable small modular reactors (SMRs) will provide the United States with another economically viable energy option, diversify the available nuclear power alternatives for the country, and enhance U.S. economic competitiveness by ensuring a domestic capability to supply demonstrated reactor technology to a growing global market for clean and affordable energy sources. Smaller nuclear power plants match the needs of much of the world that lacks highly stable, densely interconnected electrical grids. SMRs can present lower capital and operating costs than large reactors, allow incremental additions to power generation capacity that closely match load growth and support multiple energy applications (i.e., electricity and process heat). Taking advantage of their smaller size and modern design methodology, safety, security, and proliferation resistance may also be increased. Achieving the benefits of SMR deployment requires a new paradigm for plant design and management to address multi-unit, multi-product-stream generating stations. Realizing the goals of SMR deployment also depends on the resolution of technical challenges related to the unique characteristics of these reactor concepts. This paper discusses the primary issues related to SMR deployment that can be addressed through crosscutting research, development, and demonstration involving instrumentation and controls (I&C) technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning-Based Investigation of the Associations between Residential Power Consumption and Weather Conditions

Machine learning feature selection analyses were conducted to understand the impact of various weather attributes on power electricity demand and its components in the northwest United States. Load profiles data were obtained from the Northwest Energy Efficiency Alliance (NEEA) and processed to yield hourly load profiles with the same temporal resolution as the weather conditions data obtained from the National Oceanic and Atmospheric Administration (NOAA) for representative weather stations. The data were divided into five seasons; for each season, for each load component, the influences of weather factors were evaluated and quantified using cross-correlation, principal component analysis, and mutual information evaluation; then predictive models were developed based on the ranked/screened factors using the regression tree (RT) approach. After multi-fold cross-validation, the optimal complexity/depth of the regress tree models is found to vary for different load components, and the prediction accuracy using RT and weather data can be higher than 80% for heating and refrigeration, or lower than 30% for vent and cooking. The study provides guidance on improvement of load profile generation, or even serves as a standalone predictive tool for approximating load profiles in balance authorities or climate zones where load profile data is absent.

load composite, load profiling, NEEA, mutual infor↗

Local Electric Field Effects on Water Dissociation in Bipolar Membranes Studied Using Core–Shell Catalysts

The local electric field strength is thought to affect the rate of water dissociation (WD) in bipolar membranes (BPMs) at the catalyst–nanoparticle surfaces. Here, we study core–shell nanoparticles, where the core is metallic, semiconducting, or insulating, to understand this effect. The nanoparticle cores were coated with a WD catalyst layer (TiO2 or HfO2) via atomic layer deposition (ALD), and the morphology was imaged with transmission electron microscopy. Irrespective of the core material, these core–shell catalysts displayed comparable WD overpotentials at optimal mass loading, despite the hypothesized differences in the electric field strength across the catalyst particle suggested by continuum electrostatic simulations. Substantial atomic interdiffusion between the core and shell was ruled out by X-ray absorption spectroscopy, X-ray photoelectron spectroscopy, and diffuse reflectance optical measurements. However, the optimal mass loading of catalyst was roughly 1 order of magnitude higher for the conductive and high dielectric core materials than for the low dielectric insulating cores. These findings are consistent with the hypothesis that electric field screening within the core material focuses the electric field drop between particles such that larger film thicknesses can be tolerated. Collectively, these data support the idea that it is the local electric field at the molecular level that controls proton-transfer rates and that the metal core/dielectric-shell constructs introduced here modulate that field. Further materials and synthetic design may enable optimization of the electric field strength across the proton-transfer trajectory at the material surface.

Sarma, Prasad V↗

Safe Reinforcement Learning for Emergency Load Shedding of Power Systems

The paradigm shift in the electric power grid necessitates a revisit of existing control methods to ensure the grid’s security and resilience. In particular, the increased uncertainties and rapidly changing operational conditions in power systems have revealed outstanding issues in terms of either speed, adaptiveness, or scalability of the existing control methods for power systems. On the other hand, the availability of massive real-time data can provide a clearer picture of what is happening in the grid. Recently, deep reinforcement learning (RL) has been regarded and adopted as a promising approach leveraging massive data for fast and adaptive grid control. However, like most existing machine learning (ML)- based control techniques, RL control usually cannot guarantee the safety of the power systems. In this paper, we introduce a novel method for safe RL-based load shedding of power systems that can enhance the safe voltage recovery of the electric power grid after experiencing faults. Numerical simulation on the IEEE 39-bus testcase is performed to demonstrate the effectiveness of the proposed safe RL emergency control, as well as its adaptive capability to faults not seen in the training.

reinforcement learning, emergency control, power g↗