Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Combining electroweak and QCD corrections to Drell-Yan processes at hadron colliders

Precision studies of Drell-Yan production of high-transverse momentum leptons at hadron colliders require that electroweak and QCD higher-order contributions are simultaneously taken into account in theoretical predictions and data analysis. A detailed phenomenological study of the impact of electroweak and strong contributions, as well as of their combination, to the most important observables relevant for single W and Z physics programme at hadron colliders is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparative analysis of nonlinear dimensionality reduction techniques for breast MRI segmentation

Purpose: Visualization of anatomical structures using radiological imaging methods is an important tool in medicine to differentiate normal from pathological tissue and can generate large amounts of data for a radiologist to read. Integrating these large data sets is difficult and time-consuming. A new approach uses both supervised and unsupervised advanced machine learning techniques to visualize and segment radiological data. This study describes the application of a novel hybrid scheme, based on combining wavelet transform and nonlinear dimensionality reduction (NLDR) methods, to breast magnetic resonance imaging (MRI) data using three well-established NLDR techniques, namely, ISOMAP, local linear embedding (LLE), and diffusion maps (DfM), to perform a comparative performance analysis. Methods: Twenty-five breast lesion subjects were scanned using a 3T scanner. MRI sequences used were T1-weighted, T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) imaging. The hybrid scheme consisted of two steps: preprocessing and postprocessing of the data. The preprocessing step was applied for B{sub 1} inhomogeneity correction, image registration, and wavelet-based image compression to match and denoise the data. In the postprocessing step, MRI parameters were considered data dimensions and the NLDR-based hybrid approach was applied to integrate the MRI parameters into a single image, termed the embedded image. This was achieved by mapping all pixel intensities from the higher dimension to a lower dimensional (embedded) space. For validation, the authors compared the hybrid NLDR with linear methods of principal component analysis (PCA) and multidimensional scaling (MDS) using synthetic data. For the clinical application, the authors used breast MRI data, comparison was performed using the postcontrast DCE MRI image and evaluating the congruence of the segmented lesions. Results: The NLDR-based hybrid approach was able to define and segment both synthetic and clinical data. In the synthetic data, the authors demonstrated the performance of the NLDR method compared with conventional linear DR methods. The NLDR approach enabled successful segmentation of the structures, whereas, in most cases, PCA and MDS failed. The NLDR approach was able to segment different breast tissue types with a high accuracy and the embedded image of the breast MRI data demonstrated fuzzy boundaries between the different types of breast tissue, i.e., fatty, glandular, and tissue with lesions (>86%). Conclusions: The proposed hybrid NLDR methods were able to segment clinical breast data with a high accuracy and construct an embedded image that visualized the contribution of different radiological parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the logarithmic slope of F{sub 2} from the Regge gluon density behavior at small x

We study the accuracy of the Regge behavior of the gluon distribution function for an approximate relation that is frequently used to extract the logarithmic slopes of the structure function from the gluon distribution at small x. We show that the Regge behavior analysis results are comparable with HERA data and are also better than other methods that expand the gluon density at distinct points of expansion. We also show that for Q{sup 2} = 22.4 GeV{sup 2}, the x dependence of the data is well described by gluon shadowing corrections to the GLR-MQ equation. The resulting analytic expression allows us to predict the logarithmic derivative {partial_derivative}F{sub 2}(x, Q{sup 2})/{partial_derivative}lnQ{sup 2} and to compare the results with the H1 data and a QCD analysis fit with the MRST parameterization input.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lorentz number and Hall factor in degenerate semiconductors during resonance scattering of charge carriers

In highly degenerate semiconductors, the Lorentz number L and Hall factor A{sub R} differ significantly from universal constants {pi}{sup 2}/3 and 1, respectively, due to the pronounced energy dependence of the relaxation time during resonance scattering of carriers. The values of L and A{sub R} are calculated for various values of the resonant impurity bandwidth, band filling with current carriers, and the relative contribution of resonance scattering. The available published data on the bandwidth of thallium impurity states in lead telluride, where intense resonance scattering of holes was observed, are discussed. The previously obtained data on the energy of Tl in PbTe resonant states were corrected taking into account the calculated Hall factor. An analysis of the experimental data on the dependence of the PbTe:Tl thermal conductivity on the temperature and content of additional Na dopant both showed that phonon scattering by polarized regions around charged impurity atoms is negligible and confirmed the results of theoretical calculations of the Lorentz number at dominant resonance scattering of holes.

36 MATERIALS SCIENCE↗

Simulation of Subsurface Multiphase Contaminant Extraction Using a Bioslurping Well Model

Subsurface simulation of multiphase extraction from wells is notoriously difficult. Explicit representation of well geometry requires small grid resolution, potentially leading to large computational demands. To reduce the problem dimensionality, multiphase extraction is mostly modeled using vertically-averaged approaches. In this paper, a multiphase well model approach is presented as an alternative to simplify the application. The well model, a multiphase extension of the classic Peaceman model, has been implemented in the STOMP simulator. The numerical solution approach accounts for local conditions and gradients in the exchange of fluids between the well and the aquifer. Advantages of this well model implementation include the option to simulate the effects of well characteristics and operation. Simulations were conducted investigating the effects of extraction location, applied vacuum pressure, and a number of hydraulic properties. The obtained results were all consistent and logical. A major outcome of the test simulations is that, in contrast with common recommendations to extract from either the gas-NAPL or the NAPL-aqueous phase interface, the optimum extraction location should be in between these two levels. Further, the new model implementation was also used to simulate extraction at a field site in Brazil. The simulation shows a good match with the field data, suggesting that the new STOMP well module may correctly represent oil removal. The field simulations depend on the quality of the site conceptual model, including the porous media and contaminant properties and the boundary and extraction conditions adopted. The new module may potentially be used to design field applications and analyze extraction data.

42 ENGINEERING↗

A numerical study of bubble and spike velocities in shock-driven liquid metals

In this study, we use detailed continuum hydrodynamics and molecular dynamics simulations to investigate the dynamics of ejecta that are initialized with large amplitude perturbations and non-sinusoidal shapes. Insights from the simulations are used to suggest a modified expression for the velocity associated with ejected spike structures, whereas a recently suggested model explains the observed bubble velocities. Specifically, we find the asymptotic bubble velocity prediction given by Mikaelian is in excellent agreement with the simulations, when a nonlinear correction for finite amplitudes is used in that model. In contrast, existing models can overpredict observed spike velocities if they do not include the modification of the initial spike growth rates due to nonlinearities. Instead, we find that when potential flow models are corrected with a suitable nonlinear prefactor, this leads to predictions in close agreement with our simulation data. We also propose a simple empirical expression for the nonlinear correction for spike velocities which is able to reproduce results from our simulations and published experimental and simulation data over a wide range of initial conditions and Mach numbers. We discuss extensions of these models to initial interfaces with arbitrary shapes. In particular, for non-sinusoidal shapes, the bubble and spike velocities are still predicted by these models provided we use an effective wavelength λ eff which is the wavelength of an equivalent sinusoid that has the same missing area. Lastly, the issues of nonlinearity, non-standard shapes and shock Mach number addressed in this work are relevant to recent experimental campaigns involving twice-shocked targets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-20: Dead Time Count Loss Compensation in SPECT/CT: Projection Versus Global Correction

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

SU-E-I-21: Deformation Mapping and Shape Prediction with 3D Tumor Volume Morphing

Purpose: To compare projection-based versus global correction that compensate for deadtime count loss in SPECT/CT images. Methods: SPECT/CT images of an IEC phantom (2.3GBq 99mTc) with ∼10% deadtime loss containing the 37mm (uptake 3), 28 and 22mm (uptake 6) spheres were acquired using a 2 detector SPECT/CT system with 64 projections/detector and 15 s/projection. The deadtime, Ti and the true count rate, Ni at each projection, i was calculated using the monitor-source method. Deadtime corrected SPECT were reconstructed twice: (1) with projections that were individually-corrected for deadtime-losses; and (2) with original projections with losses and then correcting the reconstructed SPECT images using a scaling factor equal to the inverse of the average fractional loss for 5 projections/detector. For both cases, the SPECT images were reconstructed using OSEM with attenuation and scatter corrections. The two SPECT datasets were assessed by comparing line profiles in xyplane and z-axis, evaluating the count recoveries, and comparing ROI statistics. Higher deadtime losses (up to 50%) were also simulated to the individually corrected projections by multiplying each projection i by exp(-a*Ni*Ti), where a is a scalar. Additionally, deadtime corrections in phantoms with different geometries and deadtime losses were also explored. The same two correction methods were carried for all these data sets. Results: Averaging the deadtime losses in 5 projections/detector suffices to recover >99% of the loss counts in most clinical cases. The line profiles (xyplane and z-axis) and the statistics in the ROIs drawn in the SPECT images corrected using both methods showed agreement within the statistical noise. The count-loss recoveries in the two methods also agree within >99%. Conclusion: The projection-based and the global correction yield visually indistinguishable SPECT images. The global correction based on sparse sampling of projections losses allows for accurate SPECT deadtime loss correction while keeping the study duration reasonable.

60 APPLIED LIFE SCIENCES↗

Measurement of vertical betatron oscillations using the straw tracking detectors for the E989 muon g-2 experiment at Fermilab.

The measurement of the anomalous magnetic moment of electrons and muons has been an important test of the Standard Model (SM) of particle physics over many decades. This is because it can be measured experimentally and calculated theoretically to a high precision. In particular the anomalous magnetic moment of the muon, a µ , is an ideal candidate for the search of new physics due to the combination of the muons large mass and relatively long lifetime. The current world’s most precise value of aµ was measured by the E821 experiment at the Brookhaven National laboratory (BNL). This achieved a precision of 540 ppb (463 ppb stat., 283 ppb syst.) and measured a ~ 3.5 σ deviation from the SM value [1]. This motivated a new experiment: the E989 muon g–2 experiment at the Fermi National Accelerator Laboratory (Fermilab) to confirm or reject this discrepancy. This experiment aims to gather a data sample 21 times larger than the BNL experiment and improve the determination of the systematic uncertainties by a factor of three and thereby achieve a fourfold increase in precision to 140 ppb [2]. If the aµ value were to remain unchanged, this improvement in precision would establish evidence for Beyond SM (BSM) physics with a significance of more than 7 standard deviations. The Fermilab experiment has the same methodology as the BNL experiment and reuses the experiment’s storage ring magnet. New, improved experimental apparatus has been introduced to reduce the systematic uncertainty on the a µ measurement. One such improvement is the addition of two straw tracking stations. These measure the trajectory of the positrons emitted from the (positive) muon decays which allows a detailed study of the spatial and temporal motion of the beam and critical crosschecks of the calorimeter data. This thesis describes in detail the design, construction and testing of the tracking detectors which were built at the University of Liverpool. A detailed study of the vertical motion of the beam is also presented. This study provides an important correction that must be applied to the data before a µ can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 117: Area 26 Pluto Disassembly Facility, Nevada Test Site, Nevada With Errata Sheets, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 117, Pluto Disassembly Facility, identified in the Federal Facility Agreement and Consent Order. Corrective Action Unit 117 consists of one Corrective Action Site (CAS), CAS 26-41-01, located in Area 26 of the Nevada Test Site. This plan provides the methodology for field activities needed to gather the necessary information for closing CAS 26-41-01. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 117 using the SAFER process. Additional information will be obtained by conducting a field investigation before finalizing the appropriate corrective action for this CAS. The results of the field investigation will support a defensible recommendation that no further corrective action is necessary following SAFER activities. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The site will be investigated to meet the data quality objectives (DQOs) developed on June 27, 2007, by representatives of NDEP; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAS 26-41-01 in CAU 117.

54 ENVIRONMENTAL SCIENCES↗

The contour method cutting assumption: error minimization and correction

The recently developed contour method can measure 2-D, cross-sectional residual-stress map. A part is cut in two using a precise and low-stress cutting technique such as electric discharge machining. The contours of the new surfaces created by the cut, which will not be flat if residual stresses are relaxed by the cutting, are then measured and used to calculate the original residual stresses. The precise nature of the assumption about the cut is presented theoretically and is evaluated experimentally. Simply assuming a flat cut is overly restrictive and misleading. The critical assumption is that the width of the cut, when measured in the original, undeformed configuration of the body is constant. Stresses at the cut tip during cutting cause the material to deform, which causes errors. The effect of such cutting errors on the measured stresses is presented. The important parameters are quantified. Experimental procedures for minimizing these errors are presented. An iterative finite element procedure to correct for the errors is also presented. The correction procedure is demonstrated on experimental data from a steel beam that was plastically bent to put in a known profile of residual stresses.

36 MATERIALS SCIENCE↗

Linkage map construction using limited parental genotypic information

Abstract Genetic linkage maps based on single nucleotide polymorphisms (SNPs) represent an essential tool for a variety of genomic analyses. Today, next-generation sequencing (NGS) enables rapid genotyping of different mapping populations based on thousands of SNPs and the construction of highly saturated linkage maps. Nevertheless, missing data in the genotyping of the parental lines creates a bottleneck that determines the number of SNPs that can be used for the linkage map. As a proof of concept, a highly saturated genetic linkage map was constructed using the imputed genotypic data of a recombinant inbred line (RIL) population and the limited genotypic information of its parental lines. Two ABH genotype files were created from a pseudo-parental genotypic data set that includes all the SNPs present in the RIL population. In the first ABH file pseudo-parental 1 was considered parental A, while in the second pseudo-parental 1 was considered parental B. These two duplicate ABH genotype files were merged by chromosome and subjected to linkage map analysis. Since the ABH data were duplicated, two mirrored linkage groups were generated per chromosome. The correct linkage map was identified and selected based on the partial genotypic data of the parental lines. This strategy was effective for constructing a highly saturated linkage map of 33,421 SNPs based on the genotyping of 205 RILs and a limited number of 100 SNPs present in the parental lines. This strategy enables the use of all the NGS SNP data obtained from a low-coverage sequencing experiment in the mapping population.

59 BASIC BIOLOGICAL SCIENCES↗

Prediction and Computation of Corrosion Rates of A36 Mild Steel in Oilfield Seawater

The parameters which primarily control the corrosion rate and life of steel structures are several and they vary across the different ocean and seawater as well as along the depth. While the effect of single parameter on corrosion behavior is known, the conjoint effects of multiple parameters and the interrelationship among the variables are complex. Millions sets of experiments are required to understand the mechanism of corrosion failure. Statistical modeling such as ANN is one solution that can reduce the number of experimentation. ANN model was developed using 170 sets of experimental data of A35 mild steel in simulated seawater, varying the corrosion influencing parameters SO{sub 4}{sup 2−}, Cl{sup −}, HCO{sub 3}{sup −},CO{sub 3}{sup 2−}, CO{sub 2}, O{sub 2}, pH and temperature as input and the corrosion current as output. About 60% of experimental data were used to train the model, 20% for testing and 20% for validation. The model was developed by programming in Matlab. 80% of the validated data could predict the corrosion rate correctly. Corrosion rates predicted by the ANN model are displayed in 3D graphics which show many interesting phenomenon of the conjoint effects of multiple variables that might throw new ideas of mitigation of corrosion by simply modifying the chemistry of the constituents. The model could predict the corrosion rates of some real systems.

36 MATERIALS SCIENCE↗

Counting Kmers for Biological Sequences at Large Scale

Counting the abundance of all the distinct kmers in biological sequence data is a fundamental step in bioinformatics. These applications include de novo genome assembly, error correction, etc. With the development of sequencing technology, the sequence data in a single project can reach Petabyte-scale or Terabyte-scale nucleotides. Counting demand for the abundance of these sequencing data is beyond the memory and computing capacity of single computing node, and how to process it efficiently is a challenge on a high-performance computing cluster. As such, we propose SWAPCounter, a highly scalable distributed approach for kmer counting. This approach is embedded with an MPI streaming I/O module for loading huge data set at high speed, and a counting bloom filter module for both memory and communication efficiency. By overlapping all the counting steps, SWAPCounter achieves high scalability with high parallel efficiency. In this work, the experimental results indicate that SWAPCounter has competitive performance with two other tools on shared memory environment, KMC 2 , and MSPKmerCounter. Moreover, SWAPCounter also shows the highest scalability under strong scaling experiments. In our experiment on Cetus supercomputer, SWAPCounter scales to 32,768 cores with 79% parallel efficiency (using 2048 cores as baseline) when processing 4 TB sequence data of 1000 Genomes. The source code of SWAPCounter is publicly available at https://github.com/mengjintao/SWAPCounter.

59 BASIC BIOLOGICAL SCIENCES↗

Elucidating the temperature and density dependence of silver chloride hydration numbers in high-temperature water vapor: A first-principles molecular simulation study

Hydration numbers of metal complexes in low-density aqueous solutions are required for developing geochemical models for ore-forming metals and for designing supercritical desalination processes. In this study, we investigate the temperature and density dependence of the hydration numbers of silver chloride at 623 K, 673 K, and 713 K and densities of 10–100 kg/m 3 . Experimental estimates of the hydration number in the literature for AgCl at these conditions are inconclusive and possibly contradictory as to the temperature and density dependence. First-principles molecular simulation presents an attractive alternative to experimental measurements. Specifically, recent work shows that machine-learning-accelerated nested Monte Carlo simulations provide reliable estimates for the hydration numbers of CuCl at 623 K from 10 to 100 kg/m 3 . Using the same technique, we find a monotonic temperature dependence, with the hydration number decreasing slightly with increasing temperature. In addition, the simulation-predicted hydration numbers steadily increase with increasing density. These temperature and density trends are in agreement with certain experimental data sets. Therefore, this work demonstrates how first-principles Monte Carlo simulations assist in resolving discrepancies between experimental data sets. Our simulation results also correctly predict that the hydration number, and thus also the solubility, of AgCl is lower than that of CuCl under the same conditions. Furthermore, the bond length and angle formed between the water complex and AgCl differ from those for CuCl, consistent with the lower solubility of AgCl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fourier-based methods for removing mesh anomalies from angle resolved photoemission spectra

Recent improvements to spatial resolution in angle-resolved photo-emission spectroscopy (ARPES) have made it common to perform measurements with a very brief dwell time, for the purpose of mapping the spectral function over large surface regions. However, rapid measurement modalities can suffer a grid-like intensity modulation due to a wire mesh that is typically placed in front of the ARPES detector to block stray electrons. Here, we explore Fourier-based methods that can effectively remove this artifact, and improve the quality of ARPES images obtained in rapid scanning modes. In conclusion, an open source software package is provided containing implementations of demonstrated algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-end online performance data capture and analysis for scientific workflows

With the increased prevalence of employing workflows for scientific computing and a push towards exascale computing, it has become paramount that we are able to analyze characteristics of scientific applications to better understand their impact on the underlying infrastructure and vice-versa. Such analysis can help drive the design, development, and optimization of these next generation systems and solutions. Here, we present the architecture, integrated with existing well-established and newly developed tools, to collect online performance statistics of workflow executions from various, heterogeneous sources and publish them in a distributed database (Elasticsearch). Using this architecture, we are able to correlate online workflow performance data, with data from the underlying infrastructure, and present them in a useful and intuitive way via an online dashboard. We have validated our approach by executing two classes of real-world workflows, both under normal and anomalous conditions. The first is an I/O-intensive genome analysis workflow; the second, a CPU- and memory-intensive material science workflow. Based on the data collected in Elasticsearch, we are able to demonstrate that we can correctly identify anomalies that we injected. The resulting end-to-end data collection of workflow performance data is an important resource of training data for automated machine learning analysis.

97 MATHEMATICS AND COMPUTING↗

Tumor Delineation Based on Time-Activity Curve Differences Assessed With Dynamic Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Rectal Cancer Patients

Purpose: To develop an unsupervised tumor delineation method based on time-activity curve (TAC) shape differences between tumor tissue and healthy tissue and to compare the resulting contour with the two tumor contouring methods mostly used nowadays. Methods and Materials: Dynamic positron emission tomography-computed tomography (PET-CT) acquisition was performed for 60 min starting directly after fluorodeoxyglucose (FDG) injection. After acquisition and reconstruction, the data were filtered to attenuate noise. Correction for tissue motion during acquisition was applied. For tumor delineation, the TAC slope values were k-means clustered into two clusters. The resulting tumor contour (Contour I) was compared with a contour manually drawn by the radiation oncologist (Contour II) and a contour generated using a threshold of the maximum standardized uptake value (SUV; Contour III). Results: The tumor volumes of Contours II and III were significantly larger than the tumor volumes of Contour I, with both Contours II and III containing many voxels showing flat TACs at low activities. However, in some cases, Contour II did not cover all voxels showing upward TACs. Conclusion: Both automated SUV contouring and manual tumor delineation possibly incorrectly assign healthy tissue, showing flat TACs, as being malignant. On the other hand, in some cases the manually drawn tumor contours do not cover all voxels showing steep upward TACs, suspected to be malignant. Further research should be conducted to validate the possible superiority of tumor delineation based on dynamic PET analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗