Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “containment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Chemo-chromic Pd-V{sub 2}O{sub 5} Sensors for Passive Hydrogen Detection in Nuclear Containments - 18268

The ability to detect and monitor hydrogen gas efficiently in process and storage facilities, handling nuclear material, is crucial to ensuring their safety. The accumulation of hydrogen gas, above the lower flammable limit (LFL), in a nuclear waste containment is a concern since it creates the potential for a hydrogen-air explosion to occur, which could lead to a loss of containment and result in the uncontrolled release of radioactive material into the surrounding environment. The events that took place at Fukushima Daiichi Nuclear Power Plant highlighted the vulnerability of conventional hydrogen detection to extreme events, where power may be lost. In the present work, chemo-chromic hydrogen sensors have been fabricated, using transition metal oxide thin films, to provide eye-readable detection systems that would be resilient to plant power failure. Vanadium oxide (V{sub 2}O{sub 5}) films were prepared on quartz glass substrates by sol-gel deposition and sensitized with a palladium (Pd) catalyst, deposited by electron beam evaporation. When exposed to hydrogen, the Pd catalyst dissociates H{sub 2} to H atoms, which diffuse into the V{sup (V)}{sub 2}O{sub 5} forming a hydrogen-vanadium metal bronze, H{sub 2}V{sup (III)}{sub 2}O{sub 5}, resulting in a noticeable colour change from orange to dark green. To assess their viability for nuclear safety applications, these sensors have been irradiated to total doses between 5 and 250 kGy using a Co-60 gamma isotope irradiator. The results suggest that gamma irradiation, at the levels examined, has an effect on the initial colour of the V{sub 2}O{sub 5} and Pd-V{sub 2}O{sub 5} thin films with decreased transmittance above 540 nm. The orange starting colour darkened and developed a green tone, with the degree of colour change depending on the applied total dose. Changes in surface morphology and characteristics have been examined by using Scanning Electron Microscopy (SEM) and Raman spectroscopy. High level (250 kGy) gamma radiation exposure begins to produce surface degradation on V{sub 2}O{sub 5} thin films; however this behaviour is not observed for films that are also coated with palladium. Chemo-chromic properties of both un-irradiated and irradiated Pd-V{sub 2}O{sub 5} thin films were determined by examining their optical transmittance, using UV-vis spectroscopy, under exposure to a 4% H{sub 2}-N{sub 2} gas mixture. Exposure to gamma radiation has been found to have negligible effect upon colour change behaviour after 30 minutes exposure to hydrogen gas. The results suggest that the thin film V{sub 2}O{sub 5} sensitised with Pd is a plausible technique for application in the monitoring of hydrogen gas in low-level gamma radiation environments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Properties of Grout Monoliths Containing Organic Ion Exchange Resin - 18369

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being constructed to treat 56 million gallons of radioactive waste currently stored in underground tanks at the Hanford site. Operation of the WTP will generate several solid secondary waste (SSW) streams including spent spherical resorcinol formaldehyde cation exchange resin (IXr). The current plan for safe disposal of IXr is solidification in cementitious material (CM) typically comprised of cement, fly ash and blast furnace slag. Three CM formulations were tested to stabilize IXr for long-term land disposal. Two IXr loading rates, 0.1 and 0.3 v/v IXr:grout were used with the three CM formulations to prepare simulated waste form monoliths for hydraulic property testing. Following curing, the monoliths were removed from molds and tested to determine saturated hydraulic conductivity (K{sub sat}) and water retention properties. K{sub sat} was measured using a standard flexible permeameter method ASTM D-5084-10. A constant vapor pressure (CVP) method was used to determine van Genuchten parameters for desorption moisture retention curves for each of the SSW grout formulations. For the CVP method, vacuum saturated, intact wafers approximately 1.25 cm thick were placed above a saturated salt solution inside a sealed container for equilibration. Each saturated salt solution has an associated vapor pressure related to relative humidity in the container. Visual examination and three-dimensional x-ray micro computed tomography (μCT) indicated that the IXr was uniformly distributed in the cured waste form. Saturated hydraulic conductivity was within the range previously reported by Flach et al. in a study of the hydraulic properties of 98 pastes and grouts. The solidification of IXr in CM resulted in a waste form with water retention properties similar to cementitious pastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hardened Containment Vent System Dose Considerations for FLEX

Fukushima lessons learned include adding diverse and flexible mitigation strategies, or FLEX, that will increase defense-in-depth for beyond-design-basis (BDB) scenarios to address an Extended Loss of AC Power (ELAP). FLEX and NRC order EA-13-109 require improvements to the reliability of Hardened Containment Vent Systems (HCVS) for Mark I and II boiling water reactors (BWR) for venting of the core under severe accident conditions. NEI HCVSWP-02 provides generic guidance to determine radiological dose from HCVS piping. This paper presents a more refined analysis tool and method to assess the doses from the HCVS piping resulting from a failed core during an ELAP for a representative Mark I BWR. The dose rates up to 4' from the HCVS pipe at 8 hours after ELAP and over time at 3' are provided for the different cases. HCVS pipe length can affect dose rates farther from the pipe. As expected, dose rates versus time for representative plant case 2 drop off quickly as the HCVS activity is vented out. The dose rate results show that significant protection for personnel would be required in the areas near HCVS piping during certain time frames of containment venting. Equipment in the vicinity of the vent piping should also be evaluated for impact of radiation exposure. The results for the representative plant cases are higher and lower than the scaled NEI results depending on the model assumptions, limitations and considerations which can change as the HCVS design evolves. Using the NEI paper with scaling factors may not be conservative for all applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Viability of In-Drum Treatment for Transuranic Wastes Containing Nitrates and Organics - 20406

In February of 2014, a breach in a waste drum stored at the Waste Isolation Pilot Plant resulted in the release of radioactive material into the immediate surroundings and outside of the plant. The waste drum contained a mixture of an organic absorbent and nitrate salts that pressurized the drum, eventually causing the drum lid to fail, leading to the adverse event. Other waste drums with similar contents exist posing both storage and treatment risks. These drums may successfully be treated by an in-drum treatment system. This paper considers the design and operation of an in-drum treatment system and the characteristics of waste containing organics and nitrates to evaluate the viability of treatment. A description of the system, how it is operated, and a summary of previous testing performed is provided. Treatment of both liquids and absorbed liquids comprised of organics and nitrates is addressed. Viability of treatment is demonstrated by presenting operational methods and design strategies to ensure successful treatment of the waste drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drop Analysis of a Department of Energy Standard Canister Containing Fort Saint Vrain SNF– 24138

DOE manages over 300 types of SNF, many of which are located at the INL site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage (RRDS) is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in on-site storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale RRDS program at the INL site. One critical aspect of RRDS is the ability to certify the DOE Standard Canister and its associated transportation package in accordance with 10 CFR 71 for offsite transportation. Depending on the SNF type and transportation strategy, DOE Standard Canisters may be required to maintain structural integrity under hypothetical accident scenarios (e.g., drop events). The DOE Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs; however, no analysis has yet been completed in support of the recently initiated Road-Ready Demonstration. This paper presents preliminary results from a finite element analysis of the Ø45.7 cm × 4.6 m (Ø18 in. × 15 ft) DOE Standard Canister under the 9 m drop at 80 degrees off-vertical drop scenario considered in previous INL tests and analyses. It considers the Fort St. Vrain spent nuclear fuel loading configuration proposed for the Road-Ready Demonstration, uses updated material properties, and applies the strain-based acceptance criteria established in ASME Boiler and Pressure Vessel Code’s Section III, Division 3 rules for storage and transportation spent nuclear fuel containments. This updated analysis is compared to previous DOE Standard Canister drop analyses. Preliminary results from the updated analysis show that certain regions of the containment exceed the allowable limits during the accidental drop event. However, these regions are limited to components performing a non-structural function. While further work on this analysis will be pursued, this analysis serves as the foundation for formal calculations used to support applicable certification efforts of the RRDS system at INL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Behavior of Zinc Cold Spray Coatings in a Simulated Natural Gas Environment Containing H2O, CO2, and H2S

The natural gas transmission pipeline network in the U.S. consists of approximately 300,000 miles, is made mainly of carbon steel, and was installed in the 1950s and 1960s. Understanding the pipeline steel behavior in natural gas will inform new pipeline designs and repurposing of existing pipelines. Sulfide stress cracking (SSC) is a problem for steel pipelines transporting natural gas or CO2 containing partial pressures of H2S higher than 0.3 kPa (0.05 psi). Therefore, the objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas containing H2S using cold spray coatings.

Belarbi, Zineb↗

Drop Analysis of a Department of Energy Standard Canister Containing Fort Saint Vrain SNF

DOE manages over 300 types of SNF, many of which are located at the INL site. Managing this large variety of SNF for storage, transportation, and disposal poses a challenge to DOE. The Idaho Cleanup Project and INL are collaborating on the DOE SNF Road-Ready Demonstration (“Road-Ready Demonstration”), which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF for “road-ready dry storage.” Road-ready dry storage (RRDS) is an SNF management concept in which SNF is packaged into dry, sealed canisters that are then placed in on-site storage in anticipation of later transport and disposition. The forward-looking goal of the Road-Ready Demonstration is to establish the foundation for a large-scale RRDS program at the INL site. One critical aspect of RRDS is the ability to certify the DOE Standard Canister and its associated transportation package in accordance with 10 CFR 71 for offsite transportation. Depending on the SNF type and transportation strategy, DOE Standard Canisters may be required to maintain structural integrity under hypothetical accident scenarios (e.g., drop events). The DOE Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs; however, no analysis has yet been completed in support of the recently initiated Road-Ready Demonstration. This paper presents preliminary results from a finite element analysis of the Ø45.7 cm × 4.6 m (Ø18 in. × 15 ft) DOE Standard Canister under the 9 m drop at 80 degrees off-vertical drop scenario considered in previous INL tests and analyses. It considers the Fort St. Vrain spent nuclear fuel loading configuration proposed for the Road-Ready Demonstration, uses updated material properties, and applies the strain-based acceptance criteria established in ASME Boiler and Pressure Vessel Code’s Section III, Division 3 rules for storage and transportation spent nuclear fuel containments. This updated analysis is compared to previous DOE Standard Canister drop analyses. Preliminary results from the updated analysis show that certain regions of the containment exceed the allowable limits during the accidental drop event. However, these regions are limited to components performing a non-structural function. While further work on this analysis will be pursued, this analysis serves as the foundation for formal calculations used to support applicable certification efforts of the RRDS system at INL.

42 ENGINEERING↗

Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Reactor Containment Passive Safety Analysis: Steam Condensation in Presence of Non-condensable Gas Scaled Experiment and Modeling

This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fiber-containing particles with dual-tapered shape

Recycled carbon fibers are processed by rotational tumbling in a mixture with binder material to prepare fiber-containing particles having a dual-tapered shape and general alignment of fibers with a longitudinal direction of the particles. Bulk products including such fiber-containing particles are compounded with polymer and pelletized to prepare fiber-reinforced composite pellets, which are useful for applications such as injection molding to prepare molded products of carbon fiber-reinforced composite material with recycled carbon fibers.

Harris, Jordan Gray↗

Species identification in a laminar premixed low-pressure flame of morpholine as a model substance for oxygenated nitrogen-containing fuels.

The combustion chemistry of morpholine (1-oxa-4-aza-cyclohexane) was investigated under laminar, premixed low-pressure conditions. Morpholine, as a heterocyclic secondary amine with numerous industrial applications, was studied as a model fuel which simultaneously contains oxygen and nitrogen heteroatoms. Stable and radical intermediates and products of the combustion process in a slightly fuel-rich {phi} = 1.3 (C/O = 0.41) flat premixed morpholine-oxygen-argon flame at 40 mbar (4 kPa) were identified. A detailed fuel destruction scheme is proposed based on combined measurements using two different in situ molecular beam mass spectrometry (MBMS) techniques. The results are discussed with special attention to hydrocarbon, oxygenated and N-containing compounds important in pollutant emission.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Cysteine-Rich CCG Domain Contains a Novel [4Fe-4S] Cluster Binding Motif As Deduced From Studies With Subunit B of Heterodisulfide Reductase From Methanothermobacter Marburgensis

Heterodisulfide reductase (HDR) of methanogenic archaea with its active-site [4Fe-4S] cluster catalyzes the reversible reduction of the heterodisulfide (CoM-S-S-CoB) of the methanogenic coenzyme M (CoM-SH) and coenzyme B (CoB-SH). CoM-HDR, a mechanistic-based paramagnetic intermediate generated upon half-reaction of the oxidized enzyme with CoM-SH, is a novel type of [4Fe-4S]{sup 3+} cluster with CoM-SH as a ligand. Subunit HdrB of the Methanothermobacter marburgensis HdrABC holoenzyme contains two cysteine-rich sequence motifs (CX{sub 31-39}CCX{sub 35-36}CXXC), designated as CCG domain in the Pfam database and conserved in many proteins. Here we present experimental evidence that the C-terminal CCG domain of HdrB binds this unusual [4Fe-4S] cluster. HdrB was produced in Escherichia coli, and an iron-sulfur cluster was subsequently inserted by in vitro reconstitution. In the oxidized state the cluster without the substrate exhibited a rhombic EPR signal (g{sub zyx} = 2.015, 1.995, and 1.950) reminiscent of the CoM-HDR signal. {sup 57}Fe ENDOR spectroscopy revealed that this paramagnetic species is a [4Fe-4S] cluster with {sup 57}Fe hyperfine couplings very similar to that of CoM-HDR. CoM-{sup 33}SH resulted in a broadening of the EPR signal, and upon addition of CoM-SH the midpoint potential of the cluster was shifted to values observed for CoM-HDR, both indicating binding of CoM-SH to the cluster. Site-directed mutagenesis of all 12 cysteine residues in HdrB identified four cysteines of the C-terminal CCG domain as cluster ligands. Combined with the previous detection of CoM-HDR-like EPR signals in other CCG domain-containing proteins our data indicate a general role of the C-terminal CCG domain in coordination of this novel [4Fe-4S] cluster. In addition, Zn K-edge X-ray absorption spectroscopy identified an isolated Zn site with an S{sub 3}(O/N){sub 1} geometry in HdrB and the HDR holoenzyme. The N-terminal CCG domain is suggested to provide ligands to the Zn site.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting special nuclear materials in suspect containers using high-energy gamma rays emitted by fission products

A method and a system for detecting the presence of special nuclear materials in a suspect container. The system and its method include irradiating the suspect container with a beam of neutrons, so as to induce a thermal fission in a portion of the special nuclear materials, detecting the gamma rays that are emitted from the fission products formed by the thermal fission, to produce a detector signal, comparing the detector signal with a threshold value to form a comparison, and detecting the presence of the special nuclear materials using the comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting special nuclear materials in suspect containers using high-energy gamma rays emitted by fission products

A method and a system for detecting the presence of special nuclear materials in a suspect container. The system and its method include irradiating the suspect container with a beam of neutrons, so as to induce a thermal fission in a portion of the special nuclear materials, detecting the gamma rays that are emitted from the fission products formed by the thermal fission, to produce a detector signal, comparing the detector signal with a threshold value to form a comparison, and detecting the presence of the special nuclear materials using the comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting special nuclear materials in suspect containers using high-energy gamma rays emitted by fission products

A method and a system for detecting the presence of special nuclear materials in a suspect container. The system and its method include irradiating the suspect container with a beam of neutrons, so as to induce a thermal fission in a portion of the special nuclear materials, detecting the gamma rays that are emitted from the fission products formed by the thermal fission, to produce a detector signal, comparing the detector signal with a threshold value to form a comparison, and detecting the presence of the special nuclear materials using the comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containment Planner v 1.2

SAND2021-15061 O The Containment Planner allows the user to graphically define a foam or gel-based explosive containment plan and estimate the percentage of particulate capture, blast overpressures, and a variety of other useful quantities. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Eldridge, Bryce↗

Modeling Assumptions for the Advanced Test reactor Fresh Fuel Shipping Container

The Advanced Test Reactor Fresh Fuel Shipping Container (ATR FFSC) is currently licensed per 10 CFR 71 to transport a fresh fuel element for either the Advanced Test Reactor, the University of Missouri Research Reactor (MURR), or the Massachusetts Institute of Technology Research Reactor (MITR-II). During the licensing process, the Nuclear Regulatory Commission (NRC) raised a number of issues relating to the criticality analysis, namely (1) lack of a tolerance study on the fuel and packaging, (2) moderation conditions during normal conditions of transport (NCT), (3) treatment of minor hydrogenous packaging materials, and (4) treatment of potential fuel damage under hypothetical accident conditions (HAC). These concerns were adequately addressed by modifying the criticality analysis. A tolerance study was added for both the packaging and fuel elements, full-moderation was included in the NCT models, minor hydrogenous packaging materials were included, and fuel element damage was considered for the MURR and MITR-II fuel types.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗