Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Estimation of carbon 14 inventory in hull and end-piece wastes from Japanese commercial reprocessing operation

Hull and end-piece wastes generated from reprocessing plant operations are expected to be disposed of in a deep underground repository as Group 2 TRU wastes under the Japanese classification system. The activated metals that compose the spent fuel assemblies such as Zircaloy claddings and stainless steel nozzles are mixed and compressed after fuel dissolution, and then stuffed into stainless steel canisters. Carbon 14 is a typical activated product in the hulls and end-pieces and is mainly generated by the {sup 14}N(n,p){sup 14}C reaction. In the previous safety assessment of the TRU waste in Japan, the radionuclides inventory was calculated by ORIGEN-2 code. Some conservative assumptions and preliminary estimates were used in this calculation. For example, total radionuclides generated from a single type of fuel assembly (45 GWd/tU for a PWR unit), and the thickness of the Zircaloy oxide film on the hulls (80 μm) were both overestimated. The second assumption in particular has a large effect on exposure dose evaluation. Therefore, it is essential to have a realistic source term evaluation regarding such items as the C-14 inventory and its distribution to waste parts. In the present study, a C-14 inventory of the hull and end-piece wastes from the operation of a commercial reprocessing plant in Japan corresponding to 32,000 tU (16,000 tU in each BWR and PWR) was calculated. Analysis using individual irradiation conditions and fuel characteristics was conducted on 6 types of fuel assemblies for BWRs and 12 types for PWRs (4 pile types x 3 burnup limits). The oxide film thickness data for each fuel type cladding were obtained from the published literature. Activation calculations were performed by using ORIGEN-2 code. For the amount of spent assembly and other waste characteristics, representative values were assumed based on the published literature. As a preliminary experiment, C-14 in irradiated BWR claddings was measured and found to be consistent with the calculated activation. The total C-14 inventory was estimated as 4.46x10{sup 14} Bq, consisting of 2.58x10{sup 14} Bq for BWRs and 1.87x10{sup 14} Bq for PWRs, and is consistent with the safety assessment of 4.4x10{sup 14} Bq. However, the distribution of the C-14 inventory to hull oxide, which was estimated under the assumption of instantaneous radionuclide release in the safety assessment, decreased from 5.72x10{sup 13} Bq (13% of the total) in the previous assessment to 1.30x10{sup 13} Bq (2.9% of the total; consisting of 1.48x10{sup 12} for BWRs and 1.15x10{sup 13} for PWRs). In other words, the exposure dose peak is reduced to approximate 25% of its previous value due to the use of detailed oxide film data that the BWR cladding has a thin oxide film. Other instantaneous release components for C-14 such as the fuel residual were negligible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Verification of ABS Concrete Design Methodology Applied to the Design of the First Commercial Scale Floating Offshore Wind Turbine in the United States

The abundance of consistent high strength winds off the world’s coastlines and the close proximity to dense population centers has led to development of innovative marine structures to support wind turbines to capture this energy resource. Off the US coast, 60% of the offshore wind lies in deep water (greater than 60m) where the development of Floating Offshore Wind Turbine (FOWT) hull technology will likely be required in lieu of fixed bottom technology such as jacket structures. The United States National Renewable Energy Laboratory (NREL) and the offshore wind community commonly refer to 60m as the transition point between fixed bottom structures and floating structures due to economic reasons. Floating wind turbines deployed in the harsh offshore marine environment require the use of materials that are cost-effective, corrosion resistant, require little maintenance and are highly durable. This has led the University of Maine to develop a concrete hull technology called VolturnUS for full-scale 6MW FOWTs. In this work, experimental testing was conducted to verify the performance of the concrete under operational, serviceability, and extreme loading conditions as required by the American Bureau of Shipping Guide for Building and Classing Floating Offshore Wind Turbines. Here, the testing included structural testing sub-components of the hull and served as experimental verification of American Bureau of Shipping (ABS) concrete design methodology which is currently approved and being used to design the first commercial scale FOWTs in the United States. Two 6MW wind turbines supported on VolturnUS concrete hulls will be used for the New England Aqua Ventus I project. The project is planned to be deployed and connected to the grid by 2019 in the Northeast U.S. and is funded by the US Department of Energy.

Concretes↗

Design and Construction of a 1/15th Scale Wave Tank Model of the Azura Commercial Wave Energy Converter

The design of a 1/15th geometrically scaled wave tank model of the Azura(TM) commercial-scale wave energy device is presented. The objectives of the wave tank tests, conducted at the University of Maine Harlod Alfond Wind/Wave Ocean Engineering Lab (W2), included verification of the Azura's energy capture in irregular waves, evaluation of performance in survival wave conditions, and testing of two advanced control algorithms. Due to the difficulty in properly Froude Scaling a hydraulic system, the model used a direct-drive rotary motor/generator power take-off (PTO), with the dynamics of the hydraulic PTO included via a hardware-in-the-loop simulation. This PTO implementation led to additional design requirements being imposed on the model drivetrain. In addition to the model PTO design, the instrumentation design, structural design, and test plans are presented. The resulting model and PTO achieved a high level of controllability, and accurately emulated the dynamics of the hydraulic PTO of the full-scale Azura prototype.

16 TIDAL AND WAVE POWER↗

Mechanical and tribological property comparison of melt-compounded nanocomposites of atomic-layer-deposition-coated polyamide particles and commercial nanofillers

Mechanical and tribological properties of melt-compounded titanium dioxide nanocomposites of atomic-layer-deposition (ALD)-coated polyamide particles and commercial nanofillers were compared. The nanofiller dispersion in the polyamide matrix was studied using transmission electron microscopy showing very different morphology for the ALD-created and the traditional nanocomposites: former appearing as ribbons in the matrix whereas latter composing from spherical clusters. The effect of such morphology change on the specimen's mechanical response subjected to tensile and impact loading was investigated. The results demonstrated that ALD-created nanocomposites possess significantly higher Young's modulus than pure and traditionally filled polyamide matrix. However, transition from ductile to brittle behavior occurs especially for the ALD-created nanocomposites. Notched impact strength experiments supported this, suggesting that the impact strength of ALD-created composites decreased significantly compared to pure polyamide matrix, whereas traditionally melt-compounded nanocomposites showed no significant changes. Furthermore, the tribological properties of the selected specimens were determined and the effect of the nanofiller on the friction and scratching properties of the polyamide matrix is discussed.

36 MATERIALS SCIENCE↗

In situ plasma diagnostics study of a commercial high-power hollow cathode magnetron deposition tool

Using a newly designed and built plasma diagnostic system, the plasma parameters were investigated on a commercial 200 mm high-power hollow cathode magnetron (HCM) physical vapor deposition tool using Ta target under argon plasma. A three dimensional (3D) scanning radio frequency (rf)-compensated Langmuir probe was constructed to measure the spatial distribution of the electron temperature (T{sub e}) and electron density (n{sub e}) in the substrate region of the HCM tool at various input powers (2-15 kW) and pressures (10-70 mTorr). The T{sub e} was in the range of 1-3 eV, scaling with decreasing power and decreasing pressure. Meanwhile, n{sub e} was in the range of 4x10{sup 10}-1x10{sup 12} cm{sup -3} scaling with increasing power and decreasing pressure. As metal deposits on the probe during the probe measurements, a self-cleaning plasma cup was designed and installed in the chamber to clean the tungsten probe tip. However, its effectiveness in recovering the measured plasma parameters was hindered by the metal layer deposited on the insulating probe tube which was accounted for the variation in the plasma measurements. Using a quartz crystal microbalance combined with electrostatic filters, the ionization fraction of the metal flux was measured at various input power of 2-16 kW and pressure of 5-40 mTorr. The metal ionization fraction reduced significantly with the increasing input power and decreasing gas pressure which were attributed to the corresponding variation in the ionization cross section and the residence time of the sputtered atoms in the plasma, respectively. Both the metal neutral and ion flux increased at higher power and lower pressure. The 3D measurements further showed that the ionization fraction decreased when moving up from the substrate to the cathode.

74 ATOMIC AND MOLECULAR PHYSICS↗

Soft X-ray quantum efficiency of a commercial CMOS imaging sensor

The demonstrated performance and cost-effectiveness of complementary metal-oxide-semiconductor (CMOS) sensors make them a potentially attractive option for low-cost space-based X-ray observatories. We have previously reported on the performance of a commercially available backside-illuminated Sony IMX290LLR-C CMOS sensor and found it to offer X-ray spectral resolutions comparable to the charged coupled devices (CCDs) aboard Suzaku and Chandra and to have a sufficient radiation hardness for use in low Earth orbit. Here, in this work, we report on the quantum efficiency (QE) of this sensor, an essential metric for modeling the sensitivity of an instrument as an X-ray detector. Using the Advanced Photon Source at Argonne National Laboratory, we measure the soft X-ray QE of this CMOS sensor to be 0.28 ± 0.02 at a photon energy of 490.5 eV. This energy was chosen for its proximity to the astrophysically important O VII triplet emission lines (~574 eV) studied by the HaloSat mission. Although not surpassing that of the back-illuminated CCDs aboard Suzaku and Chandra, this QE compares favorably to that of the front-illuminated CCDs aboard the same observatories and is competitive with that of the silicon drift detectors used aboard HaloSat, making it a strong candidate for use on future X-ray small satellite (SmallSat) missions.

47 OTHER INSTRUMENTATION↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry

Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize an indirect-detection EPID configuration (ID-EPID). Amorphous silicon ID-EPIDs provide high quality low dose images for verification of radiotherapy treatments but they have limitations as dosimeters. The standard ID-EPID configuration includes a high atomic number phosphor scintillator screen, a 1 mm copper layer, and other nonwater equivalent materials covering the detector. This configuration leads to marked differences in the response of an ID-EPID compared to standard radiotherapy dosimeters such as ion chambers in water. In this study the phosphor and copper were removed from a standard commercial EPID to modify the configuration to a direct-detection EPID (DD-EPID). Using solid water as the buildup and backscatter for the detector, dosimetric measurements were performed on the DD-EPID and compared to standard dose-in-water data for 6 and 18 MV photons. The sensitivity of the DD-EPID was approximately eight times less than the ID-EPID but the signal was sufficient to produce accurate and reproducible beam profile measurements for open beams and an intensity-modulated beam. Due to the lower signal levels it was found necessary to ensure that the dark field correction (no radiation) DD-EPID signal was stable or updated frequently. The linearity of dose response was comparable to the ID-EPID but with a greater under-response at low doses. DD-EPID measurements of field size output factors and beam profiles at the depth of maximum dose (d{sub max}), and tissue-maximum ratios between the depths of 0.5 and 10 cm, were in close agreement with dose in water measurements. At depths beyond d{sub max} the DD-EPID showed a greater change in response to field size than ionisation chamber measurements and the beam penumbrae were broader compared to diode scans. The modified DD-EPID configuration studied here has the potential to improve the performance of EPIDs for dose verification of radiotherapy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of a commercial biologically based IMRT treatment planning system

A new inverse treatment planning system (TPS) for external beam radiation therapy with high energy photons is commercially available that utilizes both dose-volume-based cost functions and a selection of cost functions which are based on biological models. The purpose of this work is to evaluate quality of intensity-modulated radiation therapy (IMRT) plans resulting from the use of biological cost functions in comparison to plans designed using a traditional TPS employing dose-volume-based optimization. Treatment planning was performed independently at two institutions. For six cancer patients, including head and neck (one case from each institution), prostate, brain, liver, and rectal cases, segmental multileaf collimator IMRT plans were designed using biological cost functions and compared with clinically used dose-based plans for the same patients. Dose-volume histograms and dosimetric indices, such as minimum, maximum, and mean dose, were extracted and compared between the two types of treatment plans. Comparisons of the generalized equivalent uniform dose (EUD), a previously proposed plan quality index (fEUD), target conformity and heterogeneity indices, and the number of segments and monitor units were also performed. The most prominent feature of the biologically based plans was better sparing of organs at risk (OARs). When all plans from both institutions were combined, the biologically based plans resulted in smaller EUD values for 26 out of 33 OARs by an average of 5.6 Gy (range 0.24 to 15 Gy). Owing to more efficient beam segmentation and leaf sequencing tools implemented in the biologically based TPS compared to the dose-based TPS, an estimated treatment delivery time was shorter in most (five out of six) cases with some plans showing up to 50% reduction. The biologically based plans were generally characterized by a smaller conformity index, but greater heterogeneity index compared to the dose-based plans. Overall, compared to plans based on dose-volume optimization, plans with equivalent target coverage obtained using the biologically based TPS demonstrate improved dose distributions for the majority of normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams

Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent detector (OSLD) is determined as a function of energy, absorbed dose to water, and linear energy transfer (LET). The detector response was measured as a function of energy for absorbed doses from 0.5 to 4.0 Gy over the following ranges: 125 kVp to18 MV for photons, 6-20 MeV for electrons, 50-250 MeV for protons, and 290 MeV/u for the carbon ions. For the low LET beams, the response of the detector was linear up to 2 Gy with supralinearity occurring at higher absorbed doses. For the kilovoltage photons, the detector response relative to 6 MV increased with decreasing energy due to the higher atomic number of aluminum oxide (11.2) relative to water (7.4). For the megavoltage photons and electrons, the response was independent of energy. The response for protons was also independent of energy, but it was about 6% higher than its response to 6 MV photons. For the carbon ions, the dose response was linear for a given LET from 0.5 to 4.0 Gy, and no supralinearity was observed. However, it did exhibit LET dependence on the response relative to 6 MV photons decreasing from 1.02 at 1.3 keV/{mu}m to 0.41 at 78 keV/{mu}m. These results provide additional information on the dosimetric properties for this particular OSL detector and also demonstrate the potential for their use in photon, electron, and proton radiotherapy dosimetry with a more limited use in high LET radiotherapy dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric verification of a commercial Monte Carlo treatment planning system (VMC++) for a 9 MeV electron beam

The aim of this work was to evaluate the performance of the voxel-based Monte Carlo algorithm implemented in the commercial treatment planning system ONCENTRA MASTERPLAN for a 9 MeV electron beam produced by a linear accelerator Varian Clinac 2100 C/D. In order to realize an experimental verification of the computed data, three different groups of tests were planned. The first set was performed in a water phantom to investigate standard fields, custom inserts, and extended treatment distances. The second one concerned standard field, irregular entrance surface, and oblique incidence in a homogeneous PMMA phantom. The last group involved the introduction of inhomogeneities in a PMMA phantom to simulate high and low density materials such as bone and lung. Measurements in water were performed by means of cylindrical and plane-parallel ionization chambers, whereas measurements in PMMA were carried out by the use of radiochromic films. Point dose values were compared in terms of percentage difference, whereas the gamma index tool was used to perform the comparison between computed and measured dose profiles, considering different tolerances according to the test complexity. In the case of transverse scans, the agreement was searched in the plane formed by the intersection of beam axis and the profile (2D analysis), while for percentage depth dose curves, only the beam axis was explored (1D analysis). An excellent agreement was found for point dose evaluation in water (discrepancies smaller than 2%). Also the comparison between planned and measured dose profiles in homogeneous water and PMMA phantoms showed good results (agreement within 2%-2 mm). Profile evaluation in phantoms with internal inhomogeneities showed a good agreement in the case of ''lung'' insert, while in tests concerning a small ''bone'' inhomogeneity, a discrepancy was particularly evidenced in dose values on the beam axis. This is due to the inaccurate geometrical description of the phantom that is linked to the calculation voxel size, a feature over which the user has no control.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool

Purpose: The electronic portal imaging device (EPID) is a system for checking the patient setup; as a result of its integration with the linear accelerator and software customized for dosimetry, it is increasingly used for verification of the delivery of fixed-field intensity-modulated radiation therapy (IMRT). In order to extend such an approach to intensity-modulated arc therapy (IMAT), the combined use of an EPID system and a portal dose image prediction (PDIP) tool has been investigated. Methods: The dosimetric behavior of an EPID system, mechanically reinforced to maintain its positional stability during the accelerator gantry rotation, has been studied to assess its ability to measure portal dose distributions for IMAT treatment beams. In addition, the PDIP tool of a commercial treatment planning system, commonly used for static IMRT dosimetry, has been validated for simulating the PDIs of IMAT treatment fields. The method has been applied to the delivery verification of 23 treatment fields that were measured in their dual mode of IMRT and IMAT modalities. Results: The EPID system has proved to be appropriate for measuring the PDIs of IMAT fields; additionally the PDIP tool was able to simulate these accurately. The results are quite similar to those obtained for static IMRT treatment verification, although it was necessary to investigate the dependence of the EPID signal and of the accelerator monitor chamber response on variable dose rate. Conclusions: Our initial tests indicate that the EPID system, together with the PDIP tool, is a suitable device for the verification of IMAT plan delivery; however, additional tests are necessary to confirm these results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric validation of a commercial Monte Carlo based IMRT planning system

Purpose: Recently a commercial Monte Carlo based IMRT planning system (Monaco version 1.0.0) was released. In this study the dosimetric accuracy of this new planning system was validated. Methods: Absolute dose profiles, depth dose curves, and output factors calculated by Monaco were compared with measurements in a water phantom. Different static on-axis and off-axis fields were tested at various source-skin distances for 6, 10, and 18 MV photon beams. Four clinical IMRT plans were evaluated in a water phantom using a linear diode detector array and another six IMRT plans for different tumor sites in solid water using a 2D detector array. In order to evaluate the accuracy of the dose engine near tissue inhomogeneities absolute dose distributions were measured with Gafchromic EBT film in an inhomogeneous slab phantom. For an end-to-end test a four-field IMRT plan was applied to an anthropomorphic lung phantom with a simulated tumor peripherally located in the right lung. Gafchromic EBT film, placed in and around the tumor area, was used to evaluate the dose distribution. Results: Generally, the measured and the calculated dose distributions agreed within 2% dose difference or 2 mm distance-to-agreement. But mainly at interfaces with bone, some larger dose differences could be observed. Conclusions: Based on the results of this study, the authors concluded that the dosimetric accuracy of Monaco is adequate for clinical introduction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner

Purpose: In this study, newly formulated XR-RV3 GafChromic film was calibrated with National Institute of Standards and Technology (NIST) traceability for measurement of patient skin dose during fluoroscopically guided interventional procedures. Methods: The film was calibrated free-in-air to air kerma levels between 15 and 1100 cGy using four moderately filtered x-ray beam qualities (60, 80, 100, and 120 kVp). The calibration films were scanned with a commercial flatbed document scanner. Film reflective density-to-air kerma calibration curves were constructed for each beam quality, with both the orange and white sides facing the x-ray source. A method to correct for nonuniformity in scanner response (up to 25% depending on position) was developed to enable dose measurement with large films. The response of XR-RV3 film under patient backscattering conditions was examined using on-phantom film exposures and Monte Carlo simulations. Results: The response of XR-RV3 film to a given air kerma depended on kVp and film orientation. For a 200 cGy air kerma exposure with the orange side of the film facing the source, the film response increased by 20% from 60 to 120 kVp. At 500 cGy, the increase was 12%. When 500 cGy exposures were performed with the white side facing the x-ray source, the film response increased by 4.0% (60 kVp) to 9.9% (120 kVp) compared to the orange-facing orientation. On-phantom film measurements and Monte Carlo simulations show that using a NIST-traceable free-in-air calibration curve to determine air kerma in the presence of backscatter results in an error from 2% up to 8% depending on beam quality. The combined uncertainty in the air kerma measurement from the calibration curves and scanner nonuniformity correction was {+-}7.1% (95% C.I.). The film showed notable stability. Calibrations of film and scanner separated by 1 yr differed by 1.0%. Conclusions: XR-RV3 radiochromic film response to a given air kerma shows dependence on beam quality and film orientation. The presence of backscatter slightly modifies the x-ray energy spectrum; however, the increase in film response can be attributed primarily to the increase in total photon fluence at the sensitive layer. Film calibration curves created under free-in-air conditions may be used to measure dose from fluoroscopic quality x-ray beams, including patient backscatter with an error less than the uncertainty of the calibration in most cases.

07 ISOTOPE AND RADIATION SOURCES↗

Dosimetric and mechanical characteristics of a commercial dynamic {mu}MLC used in SRS

Purpose: The aim of this work is to carry out mechanical and dosimetric assessments on a commercial dynamic micromulti leaf collimator system to be used for stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT). Mechanical parameters such as leaf position accuracy with different gantry angles and leaf position reproducibility were measured. Also dosimetric measurements of the interleaf leakage, intraleaf transmission, penumbra width, and light field alignment were carried out. Furthermore, measurements of output factors (S{sub cp}) and in-air factors (S{sub c}) for the {mu}MLC system will be reported. Methods: EBT2 films were used to assess the leaf position error with gantry angle and after stress test, penumbra width and light field alignment. Leaf leakage was quantified using both EBT2 film and a pinpoint ion chamber. With regard to output factors, the pinpoint chamber was placed in a water phantom at 10 cm depth and 100 cm SSD. For in-air output factor measurements, 0.2 cm of brass was placed above the photon diode as build-up. Results: Measurements of mechanical parameters gave values of 0.05 cm (SD 0.035) for the average leaf position accuracy for different gantry angles and after stress test. Dosimetric measurements, yielded values of 0.22 {+-} 0.01 and 0.24 {+-} 0.01 cm, respectively, for side and head leaf penumbras. Also, average leaf abutting, leakage and transmission were found to be 0.65, 0.91, and 0.20%, respectively. Conclusions: (a) The add-on {mu}MLC system in combination with our LINAC has been commissioned to be used for clinical purposes and showed good agreement with published results for different {mu}MLC types. (b) This work has lead to the recommendation that leaves should be recalibrated after ten static beams or after each dynamic arc.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Model-based feasibility assessment and evaluation of prostate hyperthermia with a commercial MR-guided endorectal HIFU ablation array

Purpose: Feasibility of targeted and volumetric hyperthermia (40–45 °C) delivery to the prostate with a commercial MR-guided endorectal ultrasound phased array system, designed specifically for thermal ablation and approved for ablation trials (ExAblate 2100, Insightec Ltd.), was assessed through computer simulations and tissue-equivalent phantom experiments with the intention of fast clinical translation for targeted hyperthermia in conjunction with radiotherapy and chemotherapy. Methods: The simulations included a 3D finite element method based biothermal model, and acoustic field calculations for the ExAblate ERUS phased array (2.3 MHz, 2.3 × 4.0 cm{sup 2}, ∼1000 channels) using the rectangular radiator method. Array beamforming strategies were investigated to deliver protracted, continuous-wave hyperthermia to focal prostate cancer targets identified from representative patient cases. Constraints on power densities, sonication durations and switching speeds imposed by ExAblate hardware and software were incorporated in the models. Preliminary experiments included beamformed sonications in tissue mimicking phantoms under MR temperature monitoring at 3 T (GE Discovery MR750W). Results: Acoustic intensities considered during simulation were limited to ensure mild hyperthermia (T{sub max} < 45 °C) and fail-safe operation of the ExAblate array (spatial and time averaged acoustic intensity I{sub SATA} < 3.4 W/cm{sup 2}). Tissue volumes with therapeutic temperature levels (T > 41 °C) were estimated. Numerical simulations indicated that T > 41 °C was calculated in 13–23 cm{sup 3} volumes for sonications with planar or diverging beam patterns at 0.9–1.2 W/cm{sup 2}, in 4.5–5.8 cm{sup 3} volumes for simultaneous multipoint focus beam patterns at ∼0.7 W/cm{sup 2}, and in ∼6.0 cm{sup 3} for curvilinear (cylindrical) beam patterns at 0.75 W/cm{sup 2}. Focused heating patterns may be practical for treating focal disease in a single posterior quadrant of the prostate and diffused heating patterns may be useful for heating quadrants, hemigland volumes or even bilateral targets. Treatable volumes may be limited by pubic bone heating. Therapeutic temperatures were estimated for a range of physiological parameters, sonication duty cycles and rectal cooling. Hyperthermia specific phasing patterns were implemented on the ExAblate prostate array and continuous-wave sonications (∼0.88 W/cm{sup 2}, 15 min) were performed in tissue-mimicking material with real-time MR-based temperature imaging (PRFS imaging at 3.0 T). Shapes of heating patterns observed during experiments were consistent with simulations. Conclusions: The ExAblate 2100, designed specifically for thermal ablation, can be controlled for delivering continuous hyperthermia in prostate while working within operational constraints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-37: An Optical Investigation Into the Polarization and Scattering Effects Underlying the Artifacts of Radiochromic Film Dosimetry with Commercial Flatbed Scanners

Purpose: This study aims to investigate the optical properties of radiochromic EBT3 films on exposure to polarized incident light. Methods: An optical table setup was used to investigate the properties of exposed and unexposed EBT3 films. The films were placed with their long side horizontally and illuminated with polarized incident white light. The polarization of light with the electrical vector pointing vertically is referred to as 0°, accordingly horizontal orientation corresponds to 90°. The light transmission was measured depending on the polarization angle of the incident light and the polarization of a polarizer in front of the detector. Secondly, the scattering properties of exposed and unexposed films were measured by placing a plane convex lens behind the films and a screen in its focal plane. Thereby, the distribution of the scattering angles appears as an intensity map on the screen. The distributions of scattering angles caused by EBT3 films and by neutral density filters were compared. Results: EBT3 films show a strong dependence of the light transmission on the polarization of the incident light. With both polarizers parallel, a peak transmission was found at 90° orientation of the polarizers. With the rear polarizer at right angles with the front polarizer, peak transmissions were found at front polarizer orientations 45° and 135°. The scattering appears to be anisotropic with a preference direction parallel to the long side of the film. The portion of scattered light and the half value scattering angle both increase with the dose on the film. Conclusion: EBT3 films show dose dependent changes in polarized light transmission and anisotropic light scattering. These effects impair the light absorption measurements on exposed films performed with commercial flatbed scanners and are causing the well-known artifacts of radiochromic film dosimetry with flatbed scanners, the “orientation effect” and the “parabola effect”.

60 APPLIED LIFE SCIENCES↗