Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Removal of High Specific Activity Fission Products from Uranyl Sulfate Waste Solutions

The Savannah River National Laboratory (SRNL) is currently providing support to SHINE Medical Technologies (SHINE) which plans to deploy a low energy, accelerator-based neutron source to fission low enriched U in a uranyl sulfate target solution for 99 Mo production. The 99 Mo is initially separated from the fission products and target solution by an extraction column. Subsequent washing of the column will generate waste solutions containing residual U and fission product activity. A small number of high specific activity fission products (e.g., 90 Sr, 137 Cs, and 144 Ce) in these streams will likely control the classification of the low level waste (LLW). If a sufficient amount of the high specific activity isotopes are separated from the SHINE waste streams and concentrated into a waste form, it would be possible to treat a majority of the wash solutions from the column operations as a lower class of LLW (Class A versus Class B or C or Class B versus Class C). The high specific activity fission product elements could then be dispositioned as a much smaller volume of waste rather than requiring the disposal of the entire waste stream at the higher waste classification. The Savannah River Site (SRS) has experience with using monosodium titanate (MST) and crystalline silicotitanate (CST) to remove Cs and Sr from high salt content waste solutions generated during the reprocessing of nuclear fuels and targets. Both of these materials have worked very well for their intended purposes at the SRS where the fission product elements are removed from highly alkaline waste. On the other hand, SHINE waste streams from the extraction column contain H 2 SO 4 which makes the solution acidic. Additionally, the SRS waste streams do not contain other fission product elements such as transition metals or lanthanides because they precipitate upon neutralization of the SRS waste and are not present in the supernate which is dispositioned as LLW following treatment. As such, there are inherent differences between SHINE and SRS waste treatment strategies. Savannah River National Laboratory was tasked with performing scoping studies to see if MST and CST would remove Sr, Cs, and Ce from an acidic mixed metal simulant solution. Batch contact experiments were performed using MST and two CST type materials. The MST material is a 15 wt % powder in 0.15 M NaOH slurry. The MST showed low adsorption for elements of interest from acidic solution. Furthermore, the powder size makes MST non-ideal for column operations. A CST IE-911 ion exchange material had high Cs adsorption, moderate Sr, and marginal Ce adsorption. Based on adsorption of all species, the ion exchange capacity was found to be 0.032 meq/mL. A bench-top column experiment to measure elemental breakthrough curves was performed using CST IE-911 where chromatographic separations of the mixed simulant were expected to occur. While most elements behaved as expected, the lanthanide series, containing Ce, broke though the column earlier than expected. The second CST material, CST R9120, displayed high adsorption for all elements in the acidic mixed simulant solutions in a batch contact study, and had a calculated loading capacity of 0.091 meq/mL. Future studies to develop a waste treatment flowsheet should focus on CST R9120 to treat SHINE waste solutions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel imaging techniques, integrated with mineralogical, geochemical and microbiological characterizations to determine the biogeochemical controls on technetium mobility in FRC sediments

The objective of this research program was to take a highly multidisciplinary approach to define the biogeochemical factors that control technetium (Tc) mobility in FRC sediments. The aim was to use batch and column studies to probe the biogeochemical conditions that control the mobility of Tc at the FRC. Background sediment samples from Area 2 (pH 6.5, low nitrate, low {sup 99}Tc) and Area 3 (pH 3.5, high nitrate, relatively high {sup 99}Tc) of the FRC were selected (http://www.esd.ornl.gov/nabirfrc). For the batch experiments, sediments were mixed with simulated groundwater, modeled on chemical constituents of FRC waters and supplemented with {sup 99}Tc(VII), both with and without added electron donor (acetate). The solubility of the Tc was monitored, alongside other biogeochemical markers (nitrate, nitrite, Fe(II), sulfate, acetate, pH, Eh) as the 'microcosms' aged. At key points, the microbial communities were also profiled using both cultivation-dependent and molecular techniques, and results correlated with the geochemical conditions in the sediments. The mineral phases present in the sediments were also characterized, and the solid phase associations of the Tc determined using sequential extraction and synchrotron techniques. In addition to the batch sediment experiments, where discrete microbial communities with the potential to reduce and precipitate {sup 99}Tc will be separated in time, we also developed column experiments where biogeochemical processes were spatially separated. Experiments were conducted both with and without amendments proposed to stimulate radionuclide immobilization (e.g. the addition of acetate as an electron donor for metal reduction), and were also planned with and without competing anions at high concentration (e.g. nitrate, with columns containing Area 3 sediments). When the columns had stabilized, as determined by chemical analysis of the effluents, we used a spike of the short-lived gamma emitter {sup 99m}Tc (50-200 MBq; half life 6 hours) and its mobility was monitored using a {gamma}-camera. Incorporation of low concentrations of the long-lived 99Tc gave a tracer that can be followed by scintillation counting, should the metastable form of the radionuclide decay to below detection limits before the end of the experiment (complete immobilization or loss of the Tc from the column). After the Tc was reduced and immobilized, or passed through the system, the columns were dismantled carefully in an anaerobic cabinet and the pore water geochemistry and mineralogy of the columns profiled. Microbial community analysis was determined, again using molecular and culture-dependent techniques. Experimental results were also modeled using an established coupled speciation and transport code, to develop a predictive tool for the mobility of Tc in FRC sediments. From this multidisciplinary approach, we hoped to obtain detailed information on the microorganisms that control the biogeochemical cycling of key elements at the FRC, and we would also be able to determine the key factors that control the mobility of Tc at environmentally relevant concentrations at this site.

43 PARTICLE ACCELERATORS↗

ACMEV-SP2 (Single Particle Soot Photometer)

The SP2 provides information on the amounts of rBC (refractory black carbon) and of other, non-refractory substances associated with individual rBC containing particles by simultaneously measuring the scattering and incandescence signals of such particles that are directed through the cavity of a 1064 nm Nd:YAG laser. (refractory Black Carbon) rBC mixing ratio (ng/Kg) and number size distribution time series collected during the DOE-ARM sponsored ACME-V field campaign held from June 1 to September 15, 2015 rBC mixing ratio is reported at STP conditions Time resolution: 10 sec Uncertainty: ~ 30% SP2 Unit: 25 Location: Deadhorse, AK Location: N 70-degree 11' 41'' - W 148-degress. 27' 55'' SP2_dateTime: UTC rBC concentration is in units of ng/Kg - dry air. Mass Equivalent Diameters [MED] used for size distribution (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dlogDp counts for a given size bin (SP2_geo) listed as 'SP2_cnts_0 - SP2_cnts_199' and are in units of #/cc. Column naming convention: 'SP2_cnts_X' are the number of particles in bin number _X. , where _X is the row number within the 'SP2_geo' size bin column that contains the mass equivalent diameter (e.g., SP2_cnts_0 = 0.01 microns; SP2_cnts_10 = 0.060 microns, etc.). The dN/dlogDp data is time-resolved where a given row is associated with the timestamp for that row. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns This is to provide bounds for image plots (if desired) SP2 Calibration: Fullerene soot with corrrection applied for particle density as a function of particle size. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%).

54 ENVIRONMENTAL SCIENCES↗

black carbon mass loading, size distribution for CACTI - ground site

The Single-Particle Soot Photometer (SP2, Droplet Mea- surement Technologies) is an instrument that measures, in situ, the time-dependent scattering and incandescence signals produced by individual BC-containing particles as they travel through a continuous-wave laser beam. Any particle traversing the laser beam will scatter light, and the BC component of a BC-containing particle will absorb some of the laser energy until its temperature is raised to the point at which it incandesces (hereafter we adopt the standard terminology of the SP2 community and denote any substance determined by the SP2 to be BC as refractory black carbon (rBC)). The scattering signal provides information on particle size, and the incandescence signal is used for counting rBC-containing particles and yields the mass of the rBC component within each particle (obtained via calibration). Hence, the SP2 can determine size-resolved number and mass concentrations of rBC-containing particles and thus provides information on the rBC particle population-based mixing states within ambient aerosols rBC concentration is reported at STP conditions Time resolution: 1-min Uncertainty: ~ 30% SP2 Unit: 25 Location: Ascension Island, British Territory Location: 7° 56' S, 14° 25' W" SP2_dateTime: UTC rBC concentration is in units of ng/m^3 - dry air. Mass Equivalent Diameters [MED] used for size distribution (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dlogDp counts for a given size bin (SP2_geo) listed as 'SP2_cnts_0…SP2_cnts_199'. Column naming convention: 'SP2_cnts_X' are the number of particles in bin number _X. , where _X is the row number within the 'SP2_geo' size bin column that contains the mass equivalent diameter (e.g., SP2_cnts_0 = 0.01 microns; SP2_cnts_10 = 0.060 microns, etc…). The dN/dlogDp data is time-resolved where a given row is associated with the timestamp for that row. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns This is to provide bounds for image plots (if desired) SP2 Calibration: Fullerene soot with corrrection applied for particle density as a function of particle size. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%). Comments and/or requests are to be directed to Art Sedlacek (sedlacek@bnl.gov)

54 ENVIRONMENTAL SCIENCES↗

Flight contaminant trace analyser. Phase 1: Chromatographic input system

The development of a chromatographic column capable of resolving compounds associated with spacecraft atmospheres is presented. Consideration is given to sampling techniques, column parameters and operation, and column interface with a mass spectrometer. A capillary column coated with a mixture of polyalkylene glycols is found to provide the best selectivity for resolving multicomponent mixtures found in spacecraft atmospheres. Temperature programming and isothermal operation of the column are evaluated and it is found that temperature programming has a shorter analysis time for a given carrier gas flow rate and overall superior resolution. It is observed that hydrogen provides a 15% savings in analysis time over helium. Following the optimization of column operational parameters, a mixed phase Ucon capillary is prepared for evaluation during the column test period in which the test sample is automatically analyzed. Analysis of the multicomponent test mixture is completed within 45 minutes provided temperature programming is used. All but two of the test compounds are well resolved.

Source record↗

Near UV atmospheric absorption measurements from the DC-8 aircraft during the 1987 airborne Antarctic ozone experiment

During the Airborne Antarctic Ozone Experiment from 28 August to 30 September 1987 near UV zenith scattered sky measurements were made over Antarctic from the NASA DC-8 aircraft using a one third m spectrograph equipped with a diode-array detector. Scattered sky light data in the wavelength range 348 nm to 388 nm was spectrally analyzed for O3, NO2, OClO, and BrO column abundances. Slant column abudances of O3, NO2, OClO and BrO were determined, using a computer algorithm of non-linear and linear least square correlation of Antarctic scattered sky spectra to laboratory absorption cross section data. Using measured vertical electrochemical sonde ozone profiles from Palmer, Halley Bay, and the South Pole Stations the slant columns of O3 were converted into vertical column abundances. The vertical column amounts of NO2, OClO, and BrO were derived using vertical profiles calculated by a chemical model appropriate for Antarctica. NO2 vertical column abundances show steep latitudinal decrease with increasing latitude for all 13 flights carried out during the mission. In the regions where NO2 abudances are low, OClO and BrO were observed. The spatial and temporal vertical column abundances of these species are discussed in the context of the chemistry and dynamics in the antarctic polar vortex during the austral spring.

Wahner, A.↗

Interfacial stability of CoSi2/Si structures grown by molecular beam epitaxy

The stability of CoSi2/Si interfaces was examined in this study using columnar silicide structures grown on (111) Si substrates. In the first set of experiments, Co and Si were codeposited using MBE at 800 C and the resulting columnar silicide layer was capped by epitaxial Si. Deposition of Co on the surface of the Si capping layer at 800 C results in the growth of the buried silicide columns. The buried columns grow by subsurface diffusion of the deposited Co, suppressing the formation of surface islands of CoSi2. The column sidewalls appear to be less stable than the top and bottom interfaces, resulting in preferential lateral growth and ultimately in the coalescence of the columns to form a continuous buried CoSi2 layer. In the second set of experiments, annealing of a 250 nm-thick buried columnar layer at 1000 C under a 100 nm-thick Si capping layer results in the formation of a surface layer of CoSi2 with a reduction in the sizes of the CoSi2 columns. For a sample having a thicker Si capping layer the annealing leads to Ostwald ripening producing buried equiaxed columns. The high CoSi2/Si interfacial strain could provide the driving force for the observed behavior of the buried columns under high-temperature annealing.

George, T.↗

Diffusion of Na and K in the uppermost regolith of Mercury

We examine the conditions under which ions impacting the Hermean surface can act as a regional source of enhanced atmospheric column through ion implantation and subsequent release at the surface. At most latitudes, energetic (a few keV) Na or K ions which impact the nightside surface, are released quickly (well before noon) upon warming of the surface. We show that the relative sunrise/sunset difference produced by ion implantation is ((n)(sub SR) - (n)(sub SS)/(n)(sub Ave) = f, where f is the fraction of the photo-ions recycled, (n)(sub SR) is the average zenith column above the sunrise portion of the illuminated hemisphere, (n)(sub SS) is the average zenith column in the sunset portion, and (n)(sub Ave) is the average column over the sunlit disk. Thus, to produce a large sunrise/sunset difference via ion implantation and subsequent release requires efficient (close to total) recycling. We show that the most extensive set of available data reduced to Na column abundance does not show any sunrise enhancement. We argue that the K data do not permit an unambiguous interpretation in favor of sunrise/sunset differences. We further find that if an efficient surface loss process for the alkali is not operating after sunrise, the initial Na and K distribution will relax into the bulk of the solid. Preserved abundance gradients of Na and K in lunar glasses that the Arrhenius coefficients for impact glasses are likely more modest than those for laboratory glasses derived from rock by nonimpact processes, but the effect of the more modest diffusion rates is only to delay the efficient loss of Na by a few Earth days. We argue that implantation can lead to observable regional increases in the observed Na or K column densities only if it occurs at very high latitudes, where diffusion is slow. It is typically lower energy ions which impact at high latitude and these are both more numerous than the high energy ions and possess smaller average penetration depths; thus there are additional reasons to favor a high-latitude locus for any possible prompt return related increases in zenith column. We find that we cannot rule out sputtering as a source process, as the low-energy ions are efficient sputterers. Finally, we argue that the observed Na/K ratio in the atmopshere may be the expression of their different asymptotic rates of loss from the interiors of the regolith grains. If so, this allows us to fix the importance of sputtering and photon stimulated desorption relative to impact vaporization.

Killen, R. M.↗

Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

Ewing, Felecia↗

Tropospheric Ozone Profile Information Derived From "Cloud Slicing"

This study introduces a new approach to obtain ozone vertical profile information given coincident satellite measurements of both cloud-top pressure and above-cloud column ozone. This method is denoted "cloud slicing". In this study information of cloud-top pressure is derived from Geostationary Orbital Earth Satellite (GOES) infrared data, while above-cloud column ozone is obtained from the Earth Probe total ozone mapping spectrometer (TOMS) instrument. Several case examples are presented showing the feasibility of this technique as well as providing new geophysical results. Because the TOMS instrument measures backscattered UV radiation, it does detect ozone lying below dense water vapor clouds. This opaque property of TOMS can be used directly in conjunction with co-located cloud-top pressure data to derive ozone profile information in the troposphere. The cloud slicing method is an extension of the "Convective Cloud Differential" (CCD) method. In the CCD method, tropospheric column ozone (i.e., the total vertical column of ozone lying in the troposphere) is computed by taking total column ozone with low reflectivity (R less than 0.2) and subtracting from this a nearby measurement of above-cloud column ozone amount under conditions of high reflectivity (R greater than 0.9). (High reflectivity away from snow/ice conditions coincides with strong convection and tropopause-level clouds). The key element in determining tropospheric ozone profile information from the cloud slicing method is to have simultaneous and co-located measurements of both above-cloud column ozone and cloud-top pressure.

Ziemke, Jerald R.↗

Air Mass Factor Formulation for Spectroscopic Measurements from Satellites: Application to Formaldehyde Retrievals from the Global Ozone Monitoring Experiment

We present a new formulation for the air mass factor (AMF) to convert slant column measurements of optically thin atmospheric species from space into total vertical columns. Because of atmospheric scattering, the AMF depends on the vertical distribution of the species. We formulate the AMF as the integral of the relative vertical distribution (shape factor) of the species over the depth of the atmosphere, weighted by altitude-dependent coefficients (scattering weights) computed independently from a radiative transfer model. The scattering weights are readily tabulated, and one can then obtain the AMF for any observation scene by using shape factors from a three dimensional (3-D) atmospheric chemistry model for the period of observation. This approach subsequently allows objective evaluation of the 3-D model with the observed vertical columns, since the shape factor and the vertical column in the model represent two independent pieces of information. We demonstrate the AMF method by using slant column measurements of formaldehyde at 346 nm from the Global Ozone Monitoring Experiment satellite instrument over North America during July 1996. Shape factors are cumputed with the Global Earth Observing System CHEMistry (GEOS-CHEM) global 3-D model and are checked for consistency with the few available aircraft measurements. Scattering weights increase by an order of magnitude from the surface to the upper troposphere. The AMFs are typically 20-40% less over continents than over the oceans and are approximately half the values calculated in the absence of scattering. Model-induced errors in the AMF are estimated to be approximately 10%. The GEOS-CHEM model captures 50% and 60% of the variances in the observed slant and vertical columns, respectively. Comparison of the simulated and observed vertical columns allows assessment of model bias.

Palmer, Paul I.↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

Data Fusion for Earth Science Remote Sensing

Beginning in 2004, NASA has supported the development of an international network of ground-based remote sensing installations for the measurement of greenhouse gas columns. This collaboration has been successful and is currently used in both carbon cycle investigations and in the efforts to validate the GOSAT space-based column observations of CO2 and CH4. With the support of a grant, this research group has established a network of ground-based column observations that provide an essential link between the satellite observations of CO2, CO, and CH4 and the extensive global in situ surface network. The Total Carbon Column Observing Network (TCCON) was established in 2004. At the time of this report seven sites, employing modern instrumentation, were operational or were expected to be shortly. TCCON is expected to expand. In addition to providing the most direct means of tying the in situ and remote sensing data sets together, TCCON provides a means of testing the retrieval algorithms of SCIAMACHY and GOSAT over the broadest variation in atmospheric state. TCCON provides a critically maintained and long timescale record for identification of temporal drift and spatial bias in the calibration of the space-based sensors. Finally, the global observations from TCCON are improving our understanding of how to use column observations to provide robust estimates of surface exchange of C02 and CH4 in advance of the launch of OCO and GOSAT. TCCON data are being used to better understand the impact of both regional fluxes and long-range transport on gradients in the C02 column. Such knowledge is essential for identifying the tools required to best use the space-based observations. The technical approach and methodology of retrieving greenhouse gas columns from near-IR solar spectra, data quality and process control are described. Additionally, the impact of and relevance to NASA of TCCON and satellite validation and carbon science are addressed.

data fusion↗

Assessment of NO2 Observations During DISCOVER-AQ and KORUS-AQ Field Campaigns

NASA’s Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ, conducted in 2011–2014) campaign in the United States and the joint NASA and National Institute of Environmental Research (NIER) Korea–United States Air Quality Study (KORUS-AQ, conducted in 2016) in South Korea were two field study programs that provided comprehensive, integrated data sets of airborne and surface observations of atmospheric constituents, including nitrogen dioxide (NO2), with the goal of improving the interpretation of spaceborne remote sensing data. Various types of NO2 measurements were made, including in situ concentrations and column amounts of NO2 using ground- and aircraft-based instruments, while NO2 column amounts were being derived from the Ozone Monitoring Instrument (OMI) on the Aura satellite. This study takes advantage of these unique datasets by first evaluating in situ data taken from two different instruments on the same aircraft platform, comparing coincidently sampled profile-integrated columns from aircraft spirals with remotely sensed column observations from ground-based Pandora spectrometers, intercomparing column observations from the ground (Pandora), aircraft (in situ vertical spirals), and space (OMI), and evaluating NO2 simulations from coarse Global Modeling Initiative (GMI) and high-resolution regional models. We then use these data to interpret observed discrepancies due to differences in sampling and deficiencies in the data reduction process. Finally, we assess satellite retrieval sensitivity to observed and modeled a priori NO2 profiles. Contemporaneous measurements from two aircraft instruments that likely sample similar air masses generally agree very well but are also found to differ in integrated columns by up to 31.9 %. These show even larger differences with Pandora, reaching up to 53.9 %, potentially due to a combination of strong gradients in NO2 fields that could be missed by aircraft spirals and errors in the Pandora retrievals. OMI NO2 values are about a actor of 2 lower in these highly polluted environments due in part to inaccurate retrieval assumptions (e.g., a priori pro-files) but mostly to OMI’s large footprint (>312 km2).

Nitrogen dioxide↗

Transport of Explosive Residue Surrogates in Saturated Porous Media

Department of Defense operational ranges may become contaminated by particles of explosives residues (ER) as a result of low-order detonations of munitions. The goal of this study was to determine the extent to which particles of ER could migrate through columns of sandy sediment, representing model aquifer materials. Transport experiments were conducted in saturated columns (2 x 20 cm) packed with different grain sizes of clean sand or glass beads. Fine particles (approximately 2 to 50 {mu}m) of 2,6-dinitrotoluene (DNT) were used as a surrogate for ER. DNT particles were applied to the top 1 cm of sand or beads in the columns, and the columns were subsequently leached with artificial groundwater solutions. DNT migration occurred as both dissolved and particulate phases. Concentration differences between unfiltered and filtered samples indicate that particulate DNT accounted for up to 41% of the mass recovered in effluent samples. Proportionally, more particulate than dissolved DNT was recovered in effluent solutions from columns with larger grain sizes, while total concentrations of DNT in effluent were inversely related to grain size. Of the total DNT mass applied to the uppermost layer of the column, <3% was recovered in the effluent with the bulk remaining in the top 2 cm of the column. Our results suggest there is some potential for subsurface migration of ER particles and that most of the particles will be retained over relatively short transport distances.

54 ENVIRONMENTAL SCIENCES↗

Use of the ORNL Tungsten-188/Rhenium-188 Generator for Preparation of the Rhenium-188 HDD/Lipiodol Complex for Transarterial Liver Cancer Therapy

This work describes the installation, use, and quality control (QC) of the alumina-based tungsten-188 ({sup 188}W)/rhenium-188 ({sup 188}Re) generators provided by the Oak Ridge National Laboratory (ORNL). In addition, methods used for concentration of the {sup 188}Re-perrhenate bolus and preparation of {sup 188}Re-labeled HDD (4-hexadecyl-2,2,9,9-tetramethyl-4,7-diaza-1,10-decanethiol) for trans-arterial administration for therapy of nonresectable liver cancer also are described. The {sup 188}W/{sup 188}Re generator has a long useful shelf-life of several months and is a convenient on-site {sup 188}Re production system. {sup 188}Re has excellent therapeutic and imaging properties (T{sub 1/2} 16.9 hours; E{beta}{sub max} 2.12 MeV; 155-keV gamma ray, 15%) and is cost effectively obtained on demand by saline elution of the generator. The clinical efficacy of a variety of {sup 188}Re-labeled agents has been demonstrated for several therapeutic applications. Because of the favorable physical properties of {sup 188}Re, several {sup 188}Re-labeled agents are being developed and evaluated for the treatment of nonresectable/refractory liver cancer. {sup 188}Re-labeled HDD has been the most widely studied of these agents for this application and has been introduced into clinical trials at a number of institutions. The trans-arterial administration of {sup 188}Re-labeled agents for treatment of inoperable liver cancer requires use of high-level (1-2 Ci) {sup 188}W/{sup 188}Re generators. The handling of such high levels of {sup 188}Re imposes radiological precautions normally not encountered in a radiopharmacy and adequate care and ALARA (ie, 'As Low As Reasonably Achievable') principles must be followed. The ORNL generator provides consistently high {sup 188}Re yields (>75%) and low {sup 188}W parent breakthrough (<10{sup -3}%) over an extended shelf-life of several months. However, the high elution volumes (20-40 mL for 1-2 Ci generators) can require concentration of the {sup 188}Re bolus by postelution passage through silver cation chloride trapping columns used in the cost-effective tandem cation/anion column system. The silver column removes the high levels of chloride anion as insoluble AgCl, thus allowing subsequent specific trapping of the perrhenate anion on the small (QMA SeaPak) anion column. This method permits subsequent elution of {sup 188}Re-perrhenate with a small volume of saline, providing a very high activity-concentration solution. Because the {sup 188}Re-specific volume-activity concentration continually decreases with time, the tandem system is especially effective method for extending the useful generator shelf-life. Low elution flow rates (<1 mL/min) minimize any high back pressure which may be encountered during generator/tandem column elution when using tightly packed, small-particle-size commercial columns. In-house preparation of silver cation columns is recommended since the chloride trapping capacity is essentially unlimited, it is inexpensive and not limited in availability to any one supplier, and back pressure can be eliminated by the use of larger particles. Methods for the preparation of {sup 188}Re-HDD have been optimized and this agent can be obtained in high yield (80%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Full-length U-xPu-10Zr (x=0, 8, 19 wt%) Fast Reactor Fuel Test in FFTF

The Integral Fast Reactor-1 (IFR-1) experiment performed in the Fast Flux Test Facility (FFTF) was the only U-Pu-10Zr (Pu-0, 8 and 19 wt%) metallic fast reactor test with commercial-length (91.4 cm active fuel column length) conducted to date. With few remaining test reactors there is little opportunity for performing another test with a long active fuel column. The assembly was irradiated to the goal burnup of 10 at.%. The beginning of life (BOL) peak cladding temperature of the hottest pin was 608?C, cooling to 522?C at end of life (EOL). Selected fuel pins were examined non destructively using neutron radiography, precision axial gamma scanning, and both laser and spiral contact cladding profilometry. Destructive exams included plenum gas pressure, volume, and gas composition determinations on a number of pins followed by optical metallography, electron probe microanalysis (EPMA), and alpha and beta gamma autoradiography on a single U-19Pu-10Zr pin. The post-irradiation examinations (PIEs) showed very few differences compared to the short-pin (34.3 cm fuel column) testing performed on fuels of similar composition in Experimental Breeder Reactor-II (EBR-II). The fuel column grew axially slightly less than observed in the short pins, but with the same pattern of decreasing growth with increasing Pu content. There was a difference in the fuel-cladding chemical interaction (FCCI) in that the maximum cladding penetration by interdiffusion with fuel/fission products did not occur at the top of the fuel column where the cladding temperature is highest, as observed in EBR-II tests. Instead, the more exaggerated fission-rate profile of the FFTF pins resulted in a peak FCCI at ~0.7 X/L axial location along the fuel column. This resulted from a lower production of rare earth fission products higher in the fuel column as well as a much smaller delta-T between fuel center and cladding, and therefore less FCCI, despite the higher cladding temperature. This behavior could actually help extend the life of a fuel pin in a “long pin” reactor design to a higher peak fuel burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Method for the chemical separation of GE-68 from its daughter Ga-68

The present invention is directed to a generator apparatus for separating a daughter gallium-68 radioisotope substantially free of impurities from a parent gernanium-68 radioisotope, including a first resin-containing column containing parent gernanium-68 radioisotope and daughter gallium-68 radioisotope, a source of first eluent connected to said first resin-containing column for separating daughter gallium-68 radioisotope from the first resin-containing column, said first eluent including citrate whereby the separated gallium is in the form of gallium citrate, a mixing space connected to said first resin-containing column for admixing a source of hydrochloric acid with said separated gallium citrate whereby gallium citrate is converted to gallium tetrachloride, a second resin-containing column for retention of gallium-68 tetrachloride, and, a source of second eluent connected to said second resin-containing column for eluting the daughter gallium-68 radioisotope from said second resin-containing column.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗