Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

IRMA

IRMA (In)elastic Representation of Materials As S(α,β) evaluations IRMA turns one phonon model into three outputs that usually require three separate tool chains: an evaluated nuclear-data file, predicted neutron-scattering spectra, and scattering kernels for Monte Carlo transport. The three outputs draw on a single, consistent description of the material, so the evaluation, the spectroscopy that can validate it, and the transport that uses it always agree about the physics. Nuclear data. IRMA writes ENDF-6 File 7 thermal scattering evaluations on automatically constructed (α, β) grids. This part reimplements and generalizes NJOY's LEAPR: the classic kernels reproduce freshly generated NJOY2016 tapes digit for digit and published reference tapes to about 1e-4, and the generalized paths add the exact coherent one-phonon term, anisotropic Debye-Waller tensors, coherent elastic for arbitrary crystals, and a per-species partition for polyatomic materials. The tapes feed NJOY, AMPX, FUDGE, and every transport code downstream of them. Neutron spectroscopy. The irma.spectra forward model projects the same physics onto an instrument's kinematics and resolution: INS spectra for VISION and generic indirect geometries, and 2-D S(Q,E) powder maps for direct-geometry spectrometers, from a phonopy model or straight from a phonon DOS. It can be used to predict a proposed measurement before beam time; in analysis, it supplies the calculated single-scattering counterpart of a measured spectrum, from the same material description the evaluation was built from. Monte Carlo transport. The irma.ncrystal exporter writes per-temperature scattering kernels for the companion NCrystal plugin, so McStas, OpenMC, and other NCrystal-aware codes sample the same physics. The exported kernels carry the per-site anisotropic Debye-Waller tensors, keeping directional coherent-elastic physics that NCrystal's standard scalar treatment does not represent. With the same physics inside a transport code, an entire beamline becomes a virtual experiment: IRMA's end-to-end validation ran a custom McStas implementation of the ARCS spectrometer, assembled from the existing McVine and McStas models, against measured data. From a bare crystal structure. The irma mlip front end builds the phonon model itself: a structure file and a choice of potential are enough. Nine pretrained machine-learned interatomic potentials are supported, on a laptop CPU, with no first-principles calculation; an approximate phonon model for a new material costs minutes, not a DFT campaign, and the build emits prefilled inputs for all three outputs. The result is a good starting point rather than a finished evaluation: survey-quality physics with every parameter exposed for review. A converged atomistic calculation enters the same way, as a phonopy model, when higher fidelity is needed.

Ramic, Kemal [Oak Ridge National Laboratory (ORNL)↗

Radiological Monitoring Plan for the Oak Ridge Y-12 National Security Complex: Surface Water

DOE Order 458.1 requires that dose estimates consider contributions from all facilities. In the Y-12 Radiological Monitoring Plan (RMP), surface water is monitored at points that reflect individual facilities, as well as at points that reflect the combined contributions of all facilities. This monitoring plan does not consider other potential routes (i.e., airborne releases and food chains). Thus, a complete determination of total effective dose (TED) cannot be made based on this plan alone. The other routes from Y-12, and all routes from other DOE facilities on the Oak Ridge Reservation (e.g., Oak Ridge National Laboratory (ORNL) and The Heritage Center), must be considered in order to satisfy DOE Order 458.1 requirements. Determination of TED from all sites and pathways is done through the use of dose-assessment models and is documented in the Annual Site Environmental Report. This monitoring plan provides adequate monitoring goals for Y-12 surface water releases to provide input of sufficient sensitivity and accuracy to reliably determine the Y-12 surface water component of the TED. The routine radiological monitoring program is designed to monitor effluents at four types of locations: (1) treatment facilities, (2) other point and area source discharges, (3) instream locations, and (4) production building roof run-off. With this sampling and analysis program, data will be obtained on primary point sources as well as on locations that represent the composite of other potential sources. This plan will be reviewed periodically to determine necessary modifications to the sampling frequencies, parameters, and locations. Modifications, if any, will be based on the analysis of the previous data and its effectiveness in satisfying the objectives of this plan. Appendix A contains graphs of the sum of the DCS fractions for locations and frequencies contained in a previous version of this plan. The data was collected from January 2009 through December 2019. Each sample was analyzed, and each result was divided by the appropriate DCS to compute a DCS fraction. These fractions were summed for all isotopes. According to DOE –STD-1196-2011, the annual average of these sums should be below 1.

54 ENVIRONMENTAL SCIENCES↗

Centers for Disease Control and Prevention (CDC) Radiation Hazard Scale (Expanded Data Product Feedback Report)

During radiation emergencies, it is important to communicate clearly as radiation risks are often unfamiliar to many members of the general public and emergency responders, including public health workers. To partially address this issue, the Centers for Disease Control and Prevention (CDC) developed the Radiation Hazard Scale to communicate radiation risk to the general public, community leaders, and decision makers. The simple numeric scale does not require a background in radiation physics or health effects and can be used to assist people in understanding their risk and motivate protective action compliance. Lawrence Livermore National Laboratory has assisted the US Department of Energy National Nuclear Security Administration and the CDC in the development of Radiation Hazard Scale data products. This report documents the feedback received from Federal response officials on an expanded data product set. This expanded set accounts for the effects of building protection on radiation exposure and allows for the comparison between different response actions, including sheltering in place, based on the LLNL developed Regional Shelter Analysis methodology.

54 ENVIRONMENTAL SCIENCES↗

Navier: Dataflow Architecture for Computation Chemistry

Navier’s objectives were two evaluate the use of emerging technologies, especially dataflow accelerators, for high-performance computing (HPC) applications, specifically in the domain of chemistry, and to develop a prototype software stack to support such applications. Navier builds on capabilities previously developed by synergistic projects, such as PNNL Data Model Convergence (DMC) LDRD Hardware Advanced Workflows (HAW) and DuOMO, as well as DOE ARIAA. Throughout its 18 months, the Navier team developed new capabilities and artifacts at all levels of the HW/SW stack, provided a seamless way to integrate novel computing architectures (Sambanova SN10 and Xilinx Versal AI) into an existing software stack, developed chemistry workflows, data analytics tools, and HPC molecular dynamics workflows that leverage the developed stack and PNNL institutional investments in emerging architectures. Navier also explored the use of active learning to accelerate a computational chemistry workflow for organic molecules on PNNL Junction cluster (in collaboration with AMD/Xilinx). Navier developed tools, methodologies, and studies for hardware software co-design and (sparse) dataflow accelerators that are composable and can be used together or separately. These methodologies are now used in other projects, such as DOE AMAIS and HPDA. This report describes Navier’s achievement, the developed tools and methodologies, and the research findings and conclusions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NCSP supports 240 Pu prompt fission neutron spectrum (PFNS) evaluation

A new 240 Pu PFNS evaluation was recently undertaken at LANL as a strategic priority. It truly is an NCSP end-to-end product. It factors in a new differential experiment funded by NCSP, builds on theoretical work coming out of a previous NCSP nuclear data evaluation milestone and was validated with an NCERC experiment that was recently evaluated as an integral benchmark with NCSP funds.

240Pu↗

Pennsylvania and Delaware Energy Code Field Studies (Final Technical Report (FTR)

Led by Northeast Energy Efficiency Partnerships (NEEP) in partnership with Performance Systems Development (PSD), the project aimed to conduct energy code compliance field studies for single-family residential buildings in Pennsylvania and Delaware, as well as multifamily and commercial buildings in Pennsylvania. Using U.S. Department of Energy (DOE) approved methodologies, trained field teams conducted on-site observations and testing to document compliance with key energy efficiency measures, including building envelope insulation, air sealing, duct leakage, windows, and mechanical systems. Data from these studies would then be analyzed to identify construction trends and compliance gaps. The goals included published baseline data for each study, and a training roadmap tailored to each state’s needs. This roadmap would have guided outreach and training for builders, code officials, and other stakeholders on the specific code requirements that offered the greatest opportunity for improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Three-dimensional Map of the Heliosphere from IBEX

The Interstellar Boundary Explorer (IBEX) mission has shown that variations in the energetic neutral atom (ENA) flux from the outer heliosphere are associated with the solar cycle and longer-term variations in the solar wind (SW). In particular, there is a good correlation between the dynamic pressure of the outbound SW and variations in the later-observed IBEX ENA flux. The time difference between observations of the outbound SW and the heliospheric ENAs with which they correlate ranges from approximately 2 to 6 yr or more, depending on ENA energy and look direction. This time difference can be used as a means of "sounding" the heliosheath, that is, finding the average distance to the ENA source region in a particular direction. Here, we apply this method to build a 3D map of the heliosphere. We use IBEX ENA data collected over a complete solar cycle, from 2009 through 2019, corrected for survival probability to the inner heliosphere. Here we divide the data into 56 "macropixels" covering the entire sky. As each point in the sky is sampled once every 6 months, this gives us a time series of 22 points macropixel –1 on which to time-correlate. Consistent with prior studies and heliospheric models, we find that the shortest distance to the heliopause, d HP , is slightly south of the nose direction (d HP ~ 110–120 au), with a flaring toward the flanks and poles (d HP ~ 160–180 au). The heliosphere extends at least ~350 au tailward, which is the distance limit of the technique.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Nuclear Science User Facilities: Instrument Scientist Program

The traditional single institution User Facility model prevalent in the DOE complex funds Instrument Scientists (IS) full-time to collaborate with and guide users, disseminate results through publication, build a broad and competent user base, continuously improve instrumentation, enhance data collection methods, and improve data analysis methods. This model focuses the Instrument Scientist on ensuring that visiting researchers obtain the best and most comprehensive data. Instrument Scientists are also expected to establish personal research programs based on the use of the instrument(s) under their charge, which allows for further advances in instrumentation and science. This model ensures that the User Facility offers unique, world-leading instruments and data analysis to the user community, creates high demand among top researchers for the use of these capabilities, and as a result, positively impacts science and technology in the United States.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

DMTN-065: Data Management for LSST Special Programs

Special Programs are additional survey areas and/or observing strategies that are driven by specific science goals which build on, or are beyond, the core science pillars of the Wide Fast Deep Main Survey. In order to meet the requirements and enable science related to Special Programs, this document provides recommendations for Rubin Data Management regarding processing and serving data products for Special Programs. Hardware and processing boundaries on the potential diversity of data from Special Programs are discussed along with scenarios in which user-generated processing and data products might be needed to meet Special Programs' science goals.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular Autonomous Experimentation for Biological Applications

The Modular Autonomous Research System (MARS) was created to address a key challenge in scientific discovery: experiments are often slow, require significant manual labor, and generate data that is not easily integrated across different tools. This limits how quickly scientists can explore new materials, processes, and chemical reactions. Our motivation was to design a system that makes research faster, more reliable, and adaptable by combining automation with artificial intelligence. By doing so, we aimed to reduce human error, accelerate discovery, and allow researchers to quickly test many possibilities that would otherwise take months or years. Our approach was to build a flexible platform that connects laboratory robots, measurement instruments, and a central data system, all guided by artificial intelligence. MARS integrates liquid handling robots, robotic arms, and plate readers with an intelligent decision-making system that chooses the most informative experiments to run next. This creates a closed loop where experiments are performed automatically, the data is analyzed in real time, and new conditions are immediately tested. Through this work, we demonstrated that MARS can carry out multiple experiments with little or no human intervention, adapt to different scientific problems, and handle uncertain or noisy measurements in a robust way. The results show that modular and intelligent automation can significantly accelerate the pace of discovery, providing a model for future self-driving laboratories. This approach addresses the growing scientific need for adaptable, data-driven research platforms that can keep up with the complexity and scale of modern science.

59 BASIC BIOLOGICAL SCIENCES↗

The State of Demand Flexibility Programs and Rates

This report provides foundational data on programs and rates that promote demand flexibility in residential and commercial buildings in the United States. Leveraging a dataset of 148 programs and 94 rates collected through a review of utility websites, published electricity tariffs, and a database of demand-side programs, we describe the structure of demand flexibility events and the types and levels of incentives offered. For the two most common program types in our dataset—Wi-Fi thermostat and battery storage programs—we provide additional details on program designs. We also report data on program outcomes, including enrollment and participation, energy and demand savings, and costs. Furthermore, we describe the structure of dynamic rate events, report prices for critical peak pricing and variable peak pricing rates, and describe features of technology rates.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of theory and experiment in the modelling of heterogeneous electrocatalysis.

Theoretical modelling is essential to deepen our understanding of heterogeneous electrocatalytic energy conversion processes, such as water splitting. Here, Sharon Hammes-Schiffer and Giulia Galli offer their perspectives on the best strategies for successfully studying such systems. Heterogeneous electrocatalysis is critical to many energy conversion processes. Theoretical and computational approaches are essential to interpret experimental data and provide the mechanistic understanding necessary to design more effective catalysts. However, automated general procedures to build predictive theoretical and computational frameworks are not readily available; specific choices must be made in terms of the atomistic structural model and the level of theory, as well as the experimental data used to inform and validate these choices. Here we outline some best practices for modelling heterogeneous systems and present examples in the context of catalysis at metal electrodes and oxides. The level of theory should be chosen for the specific system and properties of interest, and experimental validation is essential from the beginning to the end of the study. Continuous feedback and ultimate integration between experiment and theory enhances the power of calculations to elucidate mechanisms, identify effective descriptors and clarify design principles.

Hammes-Schiffer, Sharon↗

Nexus of electrification and energy efficiency retrofit of commercial buildings at the district scale

Rapid electrification of buildings at the district scale is needed for cities to achieve climate change mitigation goals. However, most electrification studies focus on either the single building level or the city/region building stock level, and depend on the slow and uncertain process of requesting personally identifiable customer energy usage data from utilities. To answer a key question facing local policymakers: “Where can electrification proceed at scale without first upgrading the grid?” this study aims to quantify and inform building electrification impacts at the district scale using detailed building energy modeling and based on public records datasets. We explore how energy efficiency retrofits can help mitigate increased peak electric demand, and quantify impacts to energy use and carbon emissions. Building energy models of a baseline, and scenarios of simple electrification, energy retrofits, and electrification in combination with retrofits were created and simulated for 54 commercial buildings in two contiguous districts of San Francisco. A simple electrification scenario increased annual electricity consumption but reduced annual site energy usage by 15% to 17%, mainly due to replacing inefficient gas furnaces and boilers with more efficient heat pumps. Peak demand increased 7.4% for Fisherman's Wharf (e.g. within the capacity of the existing power grid), while the Design District showed a marginal decrease. Annual carbon emissions were reduced by 46% and 37%. Combining electrification with efficiency upgrades reduced peak demand by 26% and 40%, and annual carbon emissions by 63% and 64% for the two districts. Furthermore, these results indicate that impacts of electrification depend on the mix of building uses within a district, and coupling electrification with energy efficiency upgrades is an effective strategy to decarbonize buildings while maintaining or reducing the peak electric demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Evaluation of Cyber-Attacks on Grid-Interactive Efficient Buildings

Grid-interactive efficient buildings (GEBs) are not only exposed to passive threats (e.g., physical faults) but also active threats such as cyber-attacks launched on the network-based control systems. The impact of cyber-attacks on GEB operation are not yet fully understood, especially as regards the performance of grid services. To quantify the consequences of cyber-attacks on GEBs, this paper proposes a modeling and simulation framework that includes different cyber-attack models and key performance indexes to quantify the performance of GEB operation under cyber-attacks. The framework is numerically demonstrated to model and evaluate cyber-attacks such as data intrusion attacks and Denial-of-Service attacks on a typical medium-sized office building that uses the BACnet/IP protocol for communication networks. Simulation results show that, while different types of attacks could compromise the building systems to different extents, attacks via the remote control of a chiller yield the most significant consequences on a building system’s operation, including both the building service and the grid service. It is also noted that a cyber-attack impacts the building systems during the attack period as well as the post-attack period, which suggests that both periods should be considered to fully evaluate the consequences of a cyber-attack.

Fu, Yanyang↗

Deep learning to estimate permeability using geophysical data

Time-lapse electrical resistivity tomography (ERT) is a popular geophysical method to estimate three-dimensional (3D) permeability fields from electrical potential difference measurements. Traditional inversion and data assimilation methods are used to ingest this ERT data into hydrogeophysical models to estimate permeability. Due to ill-posedness and the curse of dimensionality, existing inversion strategies provide poor estimates and low resolution of the 3D permeability field. Recent advances in deep learning provide us with powerful algorithms to overcome this challenge. This paper presents a deep learning (DL) framework to estimate the 3D subsurface permeability from time-lapse ERT data. To test the feasibility of the proposed framework, we train DL-enabled inverse models on simulation data. Each measurement in both synthetic and field data is standardized by removing the mean and scaling the time-series to unit variance. This pre-processing step is necessary to bring simulation data closer to field observations. Subsurface process models based on hydrogeophysics are used to generate this synthetic data. Training performed on limited simulation data resulted in the DL model over-fitting. An advanced data augmentation based on mixup is implemented to generate additional training samples to overcome this issue. This mixup technique creates weakly labeled (low-fidelity) samples from strongly labeled (high-fidelity) data. The weakly labeled training data is then used to develop DL-enabled inverse models and reduce over-fitting. As both time-lapse ERT (1133048 features/realization) and 3D permeability (585453 features/realization) data samples are from a high-dimensional space, principal component analysis (PCA) is employed to reduce dimensionality. Encoded ERT and encoded permeability are generated using the trained PCA estimators. A deep neural network is then trained to map the encoded ERT to encoded permeability. This mixup training and unsupervised learning allowed us to build a fast and reasonably accurate DL-based inverse model under limited simulation data. Results show that proposed weak supervised learning can capture salient spatial features in the 3D permeability field. Quantitatively, the average mean squared error (in terms of the natural log) on the strongly labeled training, validation, and test datasets is less than 0.5. The R 2 -score (global metric) is greater than 0.75, and the percent error in each cell (local metric) is less than 10%. Finally, an added benefit in terms of computational cost is that the proposed DL-based inverse model is at least O(10 4 ) times faster than running a forward model once it is trained. Data generation, DL model training, and hyperparameter tuning to identify optimal neural network architectures utilized high-performance computing resources while the DL inference is performed on a standard laptop. Approximately, O(10 5 ) processor hours are used for generating data and DL tuning and training. We acknowledge that the data generation and DL model development are expensive. But once a DL model is trained, it can be re-used for inversion rapidly for the given system, with set physics and domain. Note that traditional inversion may require multiple forward model simulations (e.g., in the order of 10 to 1000), which are very expensive. This computational savings ≈ O(10 5 ) – O(10 7 )) makes the proposed DL-based inverse model attractive for subsurface imaging and real-time ERT monitoring applications due to fast and yet reasonably accurate estimations of permeability field.

58 GEOSCIENCES↗