Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “adaptive imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Adaptive guidance and control for future remote sensing systems

A unique approach to onboard processing was developed that is capable of acquiring high quality image data for users in near real time. The approach is divided into two steps: the development of an onboard cloud detection system; and the development of a landmark tracker. The results of these two developments are outlined and the requirements of an operational guidance and control system capable of providing continuous estimation of the sensor boresight position are summarized.

Lowrie, J. W.↗

Simultaneous dual-band radar development

Efforts to design and construct an airborne imaging radar operating simultaneously at L band and X band with an all-inertial navigation system in order to form a dual-band radar system are described. The areas of development include duplex transmitters, receivers, and recorders, a control module, motion compensation for both bands, and adaptation of a commercial inertial navigation system. Installation of the system in the aircraft and flight tests are described. Circuit diagrams, performance figures, and some radar images are presented.

Liskow, C. L.↗

Constructing An Image From Nonuniform-Scan Data

Algorithm performs maximum-likelihood construction of image of scene scanned nonuniformly by linear array of photodetectors, responses of which unequal. Developed to postprocess data acquired by scanning telescope aboard Infrared Astronomical Satellite (IRAS), also adaptable to generation of high-resolution imagery from data acquired in other nonuniform-scanning applications. Achievable resolution not limited by finite size of detectors, and increases with density of scans. With sufficiently dense scans, one obtains resolution beyond diffraction limit of imaging optics.

Aumann, Hartmut H.↗

Cone Beam Computed Tomography-Derived Adaptive Radiotherapy for Radical Treatment of Esophageal Cancer

Purpose: To investigate the potential for reduction in normal tissue irradiation by creating a patient specific planning target volume (PTV) using cone beam computed tomography (CBCT) imaging acquired in the first week of radiotherapy for patients receiving radical radiotherapy. Methods and materials: Patients receiving radical RT for carcinoma of the esophagus were investigated. The PTV is defined as CTV(tumor, nodes) plus esophagus outlined 3 to 5 cm cranio-caudally and a 1.5-cm circumferential margin is added (clinical plan). Prefraction CBCT are acquired on Days 1 to 4, then weekly. No correction for setup error made. The images are imported into the planning system. The tumor and esophagus for the length of the PTV are contoured on each CBCT and 5 mm margin is added. A composite volume (PTV1) is created using Week 1 composite CBCT volumes. The same process is repeated using CBCT Week 2 to 6 (PTV2). A new plan is created using PTV1 (adaptive plan). The coverage of the 95% isodose of PTV1 is evaluated on PTV2. Dose-volume histograms (DVH) for lungs, heart, and cord for two plans are compared. Results: A total of 139 CBCT for 14 cases were analyzed. For the adaptive plan the coverage of the 95% prescription isodose for PTV1 = 95.6% +- 4% and the PTV2 = 96.8% +- 4.1% (t test, 0.19). Lungs V20 (15.6 Gy vs. 10.2 Gy) and heart mean dose (26.9 Gy vs. 20.7 Gy) were significantly smaller for the adaptive plan. Conclusions: A reduced planning volume can be constructed within the first week of treatment using CBCT. A single plan modification can be performed within the second week of treatment with considerable reduction in organ at risk dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atlas-Based Semiautomatic Target Volume Definition (CTV) for Head-and-Neck Tumors

Purpose: To develop a new semiautomatic method to improve target delineation in head-and-neck cancer. Methods and Materials: We implemented an atlas-based software program using fourteen anatomic landmarks as well as the most superior and inferior computerd tomography slices for automatic target delineation, using an advanced laryngeal carcinoma as an example. Registration was made by an affine transformation. Evaluation was performed with manually drawn contours for comparison. Three physicians sampled and further applied a target volume atlas to ten other computer tomography data sets. In addition, a rapid three-dimensional (3D) correction program was developed. Results: The mean time to the first semiautomatic target delineation proposal was 2.7 minutes. Manual contouring required 20.2 minutes per target, whereas semiautomatic target volume definition with the rapid 3D correction was completed in only 9.7 minutes. The net calculation time for image registration of the target volume atlas was negligible (approximately 0.6 seconds). Our method depicted a sufficient adaptation of the target volume atlas on the new data sets, with a mean similarity index of 77.2%. The similarity index increased up to 85% after 3D correction performed by the physicians. Conclusions: We have developed a new, feasible method for semiautomatic contouring that saves a significant amount (51.8%) of target delineation time for head-and-neck cancer patients. This approach uses a target volume atlas and a landmark model. The software was evaluated by means of laryngeal cancer but has important implications for various tumor types whereby target volumes remain constant in form and do not move with respiration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-shot tomographic movies of evolving light-velocity objects

Tomography—cross-sectional imaging based on measuring radiation transmitted through an object along different directions—enables non-invasive imaging of hidden stationary objects, such as internal bodily organs, from their sequentially measured projections. Here we adapt tomographic methods to visualize—in one laser shot—the instantaneous structure and evolution of a laser-induced object propagating through a transparent Kerr medium. We reconstruct ‘movies’ of a laser pulse’s diffraction, self-focusing and filamentation from phase ‘streaks’ imprinted onto probe pulses that cross the main pulse’s path simultaneously at different angles. Multiple probes are generated and detected compactly and simply, making the system robust, easy to align and adaptable to many problems. Our technique could potentially visualize, for example, plasma wakefield accelerators, optical rogue waves or fast ignitor pulses, light-velocity objects, whose detailed space–time dynamics are known only through intensive computer simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microcalorimeter measurement of x-ray spectra from a high-temperature magnetically confined plasma

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

Eckart, M. E. (ORCID:0000000338945889)↗

Preliminary Design Studies for a Hydro-Growth Radiography Platform to Study the Double Shell Ablator Joint

Double shell target assembly requires mating two hemispheres of aluminum to form the ablator, and the design of the mating joint governs the dimensions of the gap that remains following ablator assembly. Radiographic data from double shell implosions with two different joint designs demonstrate the importance of having a smaller outer gap to minimize perturbation growth, but higher quality data is desirable for validating simulations of such localized engineering features. A double shell hydrogrowth radiography platform is proposed to enable detailed measurements of the joint feature evolution for comparison to simulation predictions. The conservative design is based on a successfully fielded double shell keyhole target, but the tungsten inner shell is replaced with molybdenum to allow imaging with X-rays from a zirconium backlighter (16.3 keV). Eulerian radiation-hydrodynamics simulations with adaptive mesh refinement are used to predict joint feature evolution for several different joint designs. Synthetic radiographs produced from ablator-only calculations demonstrate that the evolution of different joint morphologies can be radiographed and distinguished. Feedthrough of the joint perturbation to a molybdenum inner shell is predicted to be measurable at a convergence ratio of 2.

36 MATERIALS SCIENCE↗

Edge-following algorithm for tracking geological features

Sequential edge-tracking algorithm employs circular scanning to point permit effective real-time tracking of coastlines and rivers from earth resources satellites. Technique eliminates expensive high-resolution cameras. System might also be adaptable for application in monitoring automated assembly lines, inspecting conveyor belts, or analyzing thermographs, or x ray images.

Tietz, J. C.↗

Computer vision for robots; Proceedings of the Meeting, Cannes, France, December 2-6, 1985

The conference presents papers on segmentation techniques, three-dimensional recognition and representation, processing image sequences, and navigation and mobility. Particular attention is given to determining the pose of an object, adaptive least squares correlation with geometrical constraints, and the reliable formation of feature vectors for two-dimensional shape representation. Other topics include the real-time tracking of a target moving on a natural textured background, computer vision for the guidance of roving robots, and integrating sensory data for object recognition tasks.

Faugeras, O. D.↗

Fuzzy logic, neural networks, and soft computing

The past few years have witnessed a rapid growth of interest in a cluster of modes of modeling and computation which may be described collectively as soft computing. The distinguishing characteristic of soft computing is that its primary aims are to achieve tractability, robustness, low cost, and high MIQ (machine intelligence quotient) through an exploitation of the tolerance for imprecision and uncertainty. Thus, in soft computing what is usually sought is an approximate solution to a precisely formulated problem or, more typically, an approximate solution to an imprecisely formulated problem. A simple case in point is the problem of parking a car. Generally, humans can park a car rather easily because the final position of the car is not specified exactly. If it were specified to within, say, a few millimeters and a fraction of a degree, it would take hours or days of maneuvering and precise measurements of distance and angular position to solve the problem. What this simple example points to is the fact that, in general, high precision carries a high cost. The challenge, then, is to exploit the tolerance for imprecision by devising methods of computation which lead to an acceptable solution at low cost. By its nature, soft computing is much closer to human reasoning than the traditional modes of computation. At this juncture, the major components of soft computing are fuzzy logic (FL), neural network theory (NN), and probabilistic reasoning techniques (PR), including genetic algorithms, chaos theory, and part of learning theory. Increasingly, these techniques are used in combination to achieve significant improvement in performance and adaptability. Among the important application areas for soft computing are control systems, expert systems, data compression techniques, image processing, and decision support systems. It may be argued that it is soft computing, rather than the traditional hard computing, that should be viewed as the foundation for artificial intelligence. In the years ahead, this may well become a widely held position.

Zadeh, Lofti A.↗

Laser-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

The invention relates generally to systems for determining the range of an object from a reference point and, in one embodiment, to laser-directed ranging systems useful in telerobotics applications. Digital processing techniques are employed which minimize the complexity and cost of the hardware and software for processing range calculations, thereby enhancing the commercial attractiveness of the system for use in relatively low-cost robotic systems. The system includes a video camera for generating images of the target, image digitizing circuitry, and an associated frame grabber circuit. The circuit first captures one of the pairs of stereo video images of the target, and then captures a second video image of the target as it is partly illuminated by the light beam, suitably generated by a laser. The two video images, taken sufficiently close together in time to minimize camera and scene motion, are converted to digital images and then compared. Common pixels are eliminated, leaving only a digital image of the laser-illuminated spot on the target. Mw centroid of the laser illuminated spot is dm obtained and compared with a predetermined reference point, predetermined by design or calibration, which represents the coordinate at the focal plane of the laser illumination at infinite range. Preferably, the laser and camera are mounted on a servo-driven platform which can be oriented to direct the camera and the laser toward the target. In one embodiment the platform is positioned in response to movement of the operator's head. Position and orientation sensors are used to monitor head movement. The disparity between the digital image of the laser spot and the reference point is calculated for determining range to the target. Commercial applications for the system relate to active range-determination systems, such as those used with robotic systems in which it is necessary to determine the, range to a workpiece or object to be grasped or acted upon by a robot arm end-effector in response to commands generated by an operator. In one embodiment, the system provides a real-time image of the target for the operator as the robot approaches the object. The system is also adapted for use in virtual reality systems in which a remote object or workpiece is to be acted upon by a remote robot arm or other mechanism controlled by an operator.

Wells, Dennis L.↗

Recent Enhancements of the Phased Array Mirror Extendible Large Aperture (PAMELA) Telescope Testbed at MSFC

Recent incremental upgrades to the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope testbed have enabled the demonstration of phasing (with a monochromatic source) of clusters of primary mirror segments down to the diffraction limit. PAMELA upgrades include an improved Shack-Hartmann wavefront sensor, passive viscoelastic damping treatments for the voice-coil actuators, mechanical improvement of mirror surface figures, and optical bench baffling. This report summarizes the recent PAMELA upgrades, discusses the lessons learned, and presents a status of this unique testbed for wavefront sensing and control. The Marshall Space Flight Center acquired the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope in 1993 after Kaman Aerospace was unable to complete integration and testing under the limited SDIO and DARPA funding. The PAMELA is a 36-segment, half-meter aperture, adaptive telescope which utilizes a Shack-Hartmann wavefront sensor, inductive coil edge sensors, voice coil actuators, imaging CCD cameras and interferometry for figure alignment, wavefront sensing and control. MSFC originally obtained the PAMELA to supplement its research in the interactions of control systems with flexible structures. In August 1994, complete tip, tilt and piston control was successfully demonstrated using the Shack-Hartmann wavefront sensor and the inductive edge sensors.

Rakoczy, John↗

Poster Presentation: Optical Test of NGST Developmental Mirrors

An Optical Testing System (OTS) has been developed to measure the figure and radius of curvature of NGST developmental mirrors in the vacuum, cryogenic environment of the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The OTS consists of a WaveScope Shack-Hartmann sensor from Adaptive Optics Associates as the main instrument, a Point Diffraction Interferometer (PDI), a Point Spread Function (PSF) imager, an alignment system, a Leica Disto Pro distance measurement instrument, and a laser source palette (632.8 nm wavelength) that is fiber-coupled to the sensor instruments. All of the instruments except the laser source palette are located on a single breadboard known as the Wavefront Sensor Pallet (WSP). The WSP is located on top of a 5-DOF motion system located at the center of curvature of the test mirror. Two PC's are used to control the OTS. The error in the figure measurement is dominated by the WaveScope's measurement error. An analysis using the absolute wavefront gradient error of 1/50 wave P-V (at 0.6328 microns) provided by the manufacturer leads to a total surface figure measurement error of approximately 1/100 wave rms. This easily meets the requirement of 1/10 wave P-V. The error in radius of curvature is dominated by the Leica's absolute measurement error of VI.5 mm and the focus setting error of Vi.4 mm, giving an overall error of V2 mm. The OTS is currently being used to test the NGST Mirror System Demonstrators (NMSD's) and the Subscale Beryllium Mirror Demonstrator (SBNM).

Hadaway, James B.↗

Recent Enhancements of the Phased Array Mirror Extendible Large Aperture (PAMELA) Telescope Testbed at MSFC

Recent incremental upgrades to the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope testbed have enabled the demonstration of phasing (with a monochromatic source) of clusters of primary mirror segments down to the diffraction limit. PAMELA upgrades include in improved Shack-Hartmann wavefront sensor, passive viscoelastic damping treatments for the voice-coil actuators, mechanical improvement of mirror surface figures, and optical bench baffling. This report summarizes the recent PAMELA upgrades, discusses the lessons learned, and presents a status of this unique testbed for wavefront sensing and control. The Marshall Space Flight Center acquired the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope in 1993 after Kaman Aerospace was unable to complete integration and testing under the limited SDIO and DARPA funding. The PAMELA is a 36-segment, half-meter aperture, adaptive telescope which utilizes a Shack-Hartmann wavefront sensor, inductive coil edge sensors, voice coil actuators, imaging CCD cameras and interferometry for figure alignment, wavefront sensing and control. MSFC originally obtained the PAMELA to supplement its research in the interactions of control systems with flexible structures. In August 1994, complete tip, tilt and piston control was successfully demonstrated using the Shack-Hartmann wavefront sensor and the inductive edge sensors.

Rakoczy, John↗

THEMIS Surface-Atmosphere Separation Strategy and Preliminary Results

Methods refined and adapted from the TES investigation are used to develop a surface-atmosphere separation strategy for THEMIS image analysis and atmospheric temperature and opacity retrievals. Additional information is contained in the original extended abstract.

Bandfield, J. L.↗

Instrumentation for Reflectance Spectroscopy and Microspectroscopy with Application to Astrobiology

We present instrument concepts for in-situ reflectance spectroscopy over a spatial resolution range from several meters to tens of micrometers. These have been adapted to the low mass and power requirements of rover or similar platforms. Described are a miniaturized imaging spectrometer for rover mast, a combined mast and arm point spectrometer, and an imaging microspectrometer for the rover arm.

infrared↗

Surface Biology & Geology Pathfinder Data Analysis Pipeline

NASA's future global orbital mission, currently in development as the Surface Biology and Geology (SBG) Designated Observable study, will acquire relatively high resolution solar-reflected spectroscopy and thermal infrared observations. Innovative processes must be utilized for handling the high volume of data anticipated to be collected, which is anticipated to exceed 100 terabytes/day, greater than NASA's total extant airborne hyperspectral data collection. Collecting, processing/re-processing, disseminating, and exploiting this volume of data presents new challenges. To begin addressing them, NASA is drawing upon the expertise developed from its astrophysics programs to address Earth science and applications. Specifically, NASA is adapting the science processing operations technology developed for the Kepler and TESS planet-hunting missions for imaging spectroscopy data processing. This technology development has been the foundation for the remarkable scientific successes of Kepler and TESS. The Kepler/TESS data processing technology provides a scalable architecture for robust, repeatable, and replicable science and application products while enabling the Earth science community to develop, test, and implement new algorithms. Our effort to leverage this existing capability has begun by ingesting data and applying workflows from the EO-1/Hyperion 17-year mission archive that provides globally sampled visible through shortwave infrared spectra that are representative of SBG data types and volumes. This pathfinding data processing system will help define the solutions to processing SBG data volumes and will enable the scientific community to interact with the data and processing pipeline to create new science products.

Jenkins, Jon↗