Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Worker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Tribal Renewable Energy: Bishop Paiute Tribe, Residential Solar Program Phase II (Final Report)

The project consisted of the design, installation, inspection, and interconnection of 35 grid-tied, solar electric systems, totaled 123 kW rated capacity, on qualified existing low-income single-family homes located within the Bishop Paiute Reservation, which provide at least 65-79% savings in displaced electricity. Tribal job trainees were hired for each installation, gaining valuable job experience. Additionally, each homeowner was educated on energy efficiency and renewable energy. The overall project goal was to deploy clean energy systems in order to achieve the Bishop Paiute Tribe’s long-term goals of energy self-sufficiency, environmental protection, and better lives for our Tribal members and community. The energy displaced was 82.4 percent of total electricity used (exceeding estimated 65-79%)or over 170,000 kWh/year generating approximately $1.29 million worth of power for low-income families over their lifespans, while eliminating an estimated 2,640 tons of greenhouse gas emissions. This reduction makes a significant difference on the reservation giving more families money to spend on other essential items, while reducing their carbon footprint in this beautiful mountain community. Also, implementing these 35 systems provided a approximately 132 hours of paid solar installation work for tribal members. Training and good paying jobs are scarce on the reservation and solar is the fastest growing industry in CA and this training offered our members a real chance to learn and then get paid. The program is very significant to the family who qualified, as most families fall below the federal poverty guidelines, and many are living paycheck to paycheck. Overall, the triple impact of the Bishop Paiute Tribe Residential Solar Program Phase II— affordable energy for low-income families, on-site clean energy production, and hands-on solar installation jobs for local workers—these all help build the Tribe’s energy, economic, environmental, and social self-sufficiency and sovereignty amongst the most needy on the Reservation

14 SOLAR ENERGY↗

Industrial Energy Management During a Pandemic: Lessons Learned from DOE Better Plants Program Partners

The COVID-19 pandemic is causing many challenges for manufacturers, especially those that depend on workers whose jobs cannot be performed remotely. This has detrimentally impacted the energy management workforce, energy support system performance, as well as operations and supply chains.This article discusses four primary challenges for industrial energy management caused by the pandemic, strained budget for energy projects, increased energy intensity caused by low production rates and other safety practices, limited access to energy systems, and the lost knowledge and experience of senior staff. This article also proposes some potential solutions for these challenges that include implementing no- and low-cost energy conservation measures, adopting alternative financing options, improving shutdown procedures, reducing baseloads, creating an effective online energy-monitoring system, performing virtual energy assessments, building a robust EnMS, and attending online and in-person training events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream (Volume 1)

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the Hanford AP tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing on a slipstream from the Hanford AP tank exhauster was conducted on March 23-24, 2018. This testing focused on both APR and PAPR cartridges. Previous testing of APR cartridges was conducted on the AP exhauster in June of 2016. However, an AP exhauster upgrade was completed in September 2016. In the most recent testing, slipstream vapors from the new AP exhauster were fed to two respirator cartridge test stands, one for the PAPR respirator cartridges and the other for the APR respirator cartridges. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—were also tested consecutively over the same two days as the APR cartridge tests, using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Criticality and Radiation Shielding Analysis for the Storage and Transfer of MARVEL Reactor Spent Nuclear Fuel

This report documents the results of preliminary nuclear criticality and radiation shielding assessments during transfer and dry storage of irradiated Microreactor Applications Research Validation and Evaluation (MARVEL) reactor fuel at Idaho National Laboratory (INL). The assessments focus on transfer casks and storage canisters that are currently in use at INL, which may be compatible with the irradiated MARVEL reactor fuel. The criticality assessments were performed using the radiation transport code MCNP6 with 37 MARVEL reactor fuel elements in various configurations and scenarios. All transfer and storage configurations under dry conditions were below the assumed criticality safety limit of 0.93. Some storage and transfer configurations under wet conditions exceeded the criticality safety limit. This suggests that the appropriate administrative and engineering controls, in addition to reducing the number of MARVEL reactor fuel elements per transfer cask or storage canister, can be expected to ensure criticality safety under all scenarios. The radiation shielding assessments were performed by generating conservative neutron and photon source terms using the ORIGEN module in the SCALE suite of codes. These source spectra were used to estimate the dose equivalent rates using the radiation transport code MCNP6, both on contact and 1 m away from the fuel and transfer casks. The maximum estimated dose equivalent rate of 37 unshielded MARVEL reactor fuel elements on contact is approximately 42000 R/hr. The maximum estimated dose equivalent rates on contact to the ATR transfer cask, HFEF-5 transfer cask, and high load charger were approximately 233 mR/hr, 171 mR/hr, and 201 mR/hr, respectively. This suggests that with the appropriate administrative and engineering controls, all three transfer casks analyzed can be expected to provide sufficient radiation shielding to workers during transfer of irradiated MARVEL reactor fuel. These calculations are performed to support the planning and strategy for the MARVEL project and will demonstrate the technical viability of the different configurations discussed and help identify where engineered or administrative controls may be necessary. A complete criticality safety analysis and radiation shielding analysis, including validation and contingency and accident analysis must be completed by licensed and authorized personnel before any transfer or storage of MARVEL reactor nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extension of OpenMC for Fixed Source Transmutation Calculations

This report documents work performed under a Strategic Partnership Project between Argonne National Laboratory (ANL) and the United Kingdom Atomic Energy Authority (UKAEA). The overall goal of this project is to extend OpenMC [1], a community-developed Monte Carlo particle transport code, to be able to perform fixed-source transmutation calculations. In fission and fusion reactors, the high flux of energetic neutrons causes materials within the reactor to “transmute,” or undergo a nuclear reaction that results in the addition/removal of neutrons and protons from the nucleus of an atom. If subjected to these reactions for long enough, the overall composition and physical properties of the material itself begin to change as a result of transmutation. Such a feature is vital for predicting the decrease in tritium production rate within a breeder blanket during the lifetime of a fusion reactor. OpenMC is capable of simulating neutron transport in fission/fusion systems, thereby allowing it to estimate the flux that causes transmutation. It is also capable of solving the transmutation equations, which determine how the composition of a material changes over time due to neutron irradiation and radioactive decay. However, solving the transmutation equations was previously only possible when the source of neutrons came from a fission system. In a fusion system, the source of neutrons is typically determined by a separate code and then given as an input to the particle transport simulation. This is known as a fixed source calculation. Through this project, we have extended OpenMC to solve the transmutation equations for a fixed source calculation. Evaluating the change in material compositions due to transmutation and its effect on physical properties is of key importance to a range of engineering analyses for fission and fusion systems. For example, in a fusion reactor, estimating the dose rate at different physical locations resulting from irradiated materials in the reactor allows designers to ensure that workers are not exposed to doses beyond applicable regulations. In order to properly dispose of irradiated materials, designers also need to estimate the radiotoxicity, which again relies on knowledge of the material composition at some future time. The specific tasks for this project that were agreed to between ANL and UKAEA were as follows: 1. Make changes and additions in the openmc.deplete and related modules in OpenMC to support transmutation calculations following a fixed source transport simulation. 2. Make necessary changes to OpenMC to model transmutation due to an arbitrary set of reactions needed for fusion applications. Use this new capability to generate a depletion chain file based on the TENDL nuclear data library. 3. Improve the openmc.deplete module in OpenMC to keep track of gases produced as a by-product of nuclear reactions during transmutation calculations. 4. Validate the new capabilities by carrying out fixed-source transmutation calculations on a suitable benchmark problem using OpenMC and a comparable Monte Carlo neutron transport code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Applicability of Public Dose Limits to Individuals on the Nevada National Security Site

Historically all persons working on the Nevada National Security Site (NNSS) were considered subject to worker dose limits when calculations of potential dose from the air pathway were conducted to demonstrate compliance with Title 42 United States Code (USC) Chapter 85, “The Clean Air Act,” and Title 40 Code of Federal Regulations (CFR) Part 61, Subpart H, “National Emission Standards for Hazardous Air Pollutants (NESHAP).” Calculations were also conducted for the all-pathways potential dose to demonstrate compliance with U.S. Department of Energy (DOE) Order DOE O 458.1 Chg. 3, “Radiation Protection of the Public and the Environment.” The need to evaluate environmental air sampling locations and past regulator questions about the existence of persons potentially subject to public dose limits being on the NNSS drove this assessment (letter from EPA [U.S. Environmental Protection Agency] Region 9 to DOE/Nevada Operations Office, dated September 3, 1999). This assessment also supports determining those persons subject to public dose limits from the all pathways perspective. A person that is a member of the public is subject to public dose limits.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mosquito Distribution and West Nile Virus Surveillance Results on the Nevada National Security Site in South Central Nevada

A 10-year study (2004-2013) was conducted to determine mosquito distribution and the prevalence of West Nile Virus (WNV) on the Nevada National Security Site (NNSS) in south central Nevada. Mosquito traps baited with dry ice were set overnight at sites where standing water provided potential breeding sites for mosquitoes. Captured mosquitoes were identified to species and tested for WNV. A total of 556 mosquitoes representing 6 species were captured and identified at 20 sites around the NNSS during 124 surveys. A vast majority (89%) of mosquitoes were Culex tarsalis. None of the mosquitoes tested were positive for WNV although 2 samples, both Culiseta inornata, were suspect for WNV in 2005 and 2006, both from Well 3 Pond. Additionally, 24 birds representing 5 species were opportunistically collected and tested for WNV with no positive results. Results from this study reveal patterns of mosquito distribution across the NNSS and suggest that NNSS workers have a very low risk of being exposed to WNV.

60 APPLIED LIFE SCIENCES↗

NNSA-IAEC Science and Technology Working Group Area V - Waste Management and Subsurface Science, (Q1 FY2021)

The objective of Topic Area V is to evaluate the feasibility and safety of an intermediate-depth borehole for disposal of IAEC nuclear waste. The IAEC nuclear waste is currently stored in above ground and/or in near-surface facilities that provide short-term radiological worker safety but do not provide long-term, full security and safeguards protection for the nuclear material. Disposal of the IAEC nuclear waste several hundred meters below the surface in a sealed borehole would provide long-term security and safeguards due to its depth underground, as well as long-term radiological safety, due to its isolation in a stable geological formation.

54 ENVIRONMENTAL SCIENCES↗

A Comprehensive Radiological Characterization of the ACRR Facility

Radiation Protection (628) in conjunction with Nuclear Facility Operations (1381) completed a comprehensive radiological conditions characterization of the ACRR facility between August 2015 and January 2017 to better understand the radiological environment in and around the ACRR High-Bay. The overall goals of the characterization, as identified by 1381 and 628, were to determine potential dose to workers during routine reactor operations, areas of potential elevated dose in and around the ACRR High-Bay, the relationship between reactor power and dose during steady-state operations, and the dose per pulse for pulsed operations. To accomplish this, eight configurations were identified of interest for characterization based on increased dose potential for which field surveys were completed to include assessment of the neutron spectra for each, determination of neutron dose conversion factors (Neutron Codes) based on defined neutron spectra, mapped dose surveys for each configuration, as well as determination of the relationship between dose and reactor power level during steady-state reactor operations. Steady-state survey data was also used to calculate dose per pulse approximations during pulsed reactor operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Workspace and Office Design: A Review of the Literature

The Systems Analysis & Decision Support (02150) group completed a review of the research literature on workspace and office design in 2016 for the Asset Management Department (04853). The goal was to characterize results and lessons learned from existing research to understand the effectiveness of current workspaces at Sandia National Laboratories and inform guidance for future workspace design. The study team reviewed 96 documents, published primarily since the year 2000, covering a range of factors associated with workspace design - workspace costs, acoustics, collaboration and privacy, generational preferences, employee health, performance and productivity, organizational retention, and workspace satisfaction. The research literature consistently highlighted the relative deficiencies of open-plan office spaces as compared to traditional private enclosed offices for knowledge workers. While open-plan offices can provide some cost savings, they may not be cost effective in the long term due to future hidden costs incurred by degradations in employee productivity, increased attrition, and increased sickness absences as well as any post-construction modifications needed to resolve emerging workspace issues. The chief deficiencies of open-plan offices include lower levels of employee satisfaction due to reduced visual and auditory privacy, increased interruptions, distractions from irrelevant background speech, less physical space, and more ambient noise. The drawbacks reported in the literature tend to outweigh any benefits associated with potential facilitation of coworker interactions and collaboration. Key suggestions identified in the literature to guide and optimize workspace and office design are provided.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Investigation of Critical Pit Size in Savy 4000 Wall

The Department of Energy (DOE) issued DOE M 441.1-1, Nuclear Material Packaging Manual, in March 2008 to protect workers who handle nuclear material from exposure due to loss of containment of stored materials. The Manual specifies a detailed approach to achieve high confidence in containers and includes requirements for container design and performance, design-life determinations, material contents, and surveillance and maintenance to ensure container integrity over time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Economic Model for Estimation of GDP Losses in the MACCS Offsite Consequence Analysis Code

The MACCS (MELCOR Accident Consequence Code System) code is the U.S. Nuclear Regulatory Commission (NRC) tool used to perform probabilistic health and economic consequence assessments for atmospheric releases of radionuclides. It is also used by international organizations, both reactor owners and regulators. It is intended and most commonly used for hypothetical accidents that could potentially occur in the future rather than to evaluate past accidents or to provide emergency response during an ongoing accident. It is designed to support probabilistic risk and consequence analyses and is used by the NRC, U.S. nuclear licensees, the Department of Energy, and international vendors, licensees, and regulators. This report describes the modeling framework, implementation, verification, and benchmarking of a GDP-based model for economic losses that has recently been developed as an alternative to the original cost-based economic loss model in MACCS. The GDP-based model has its roots in a code developed by Sandia National Laboratories for the Department of Homeland Security to estimate short-term losses from natural and manmade accidents, called the Regional Economic Accounting analysis tool (REAcct). This model was adapted and modified for MACCS and is now called the Regional Disruption Economic Impact Model (RDEIM). It is based on input-output theory, which is widely used in economic modeling. It accounts for direct losses to a disrupted region affected by an accident, indirect losses to the national economy due to disruption of the supply chain, and induced losses from reduced spending by displaced workers. RDEIM differs from REAcct in its treatment and estimation of indirect loss multipliers, elimination of double counting associated with inter-industry trade in the affected area, and that it is designed to be used to estimate impacts for extended periods that can occur from a major nuclear reactor accident, such as the one that occurred at the Fukushima Daiichi site in Japan. Most input-output models do not account for economic adaptation and recovery, and in this regard RDEIM differs from its parent, REAcct, because it allows for a user-definable national recovery period. Implementation of a recovery period was one of several recommendations made by an independent peer review panel to ensure that RDEIM is state-of-practice. For this and several other reasons, RDEIM differs from REAcct. Both the original and the RDEIM economic loss models account for costs from evacuation and relocation, decontamination, depreciation, and condemnation. Where the original model accounts for an expected rate of return, based on the value of property, that is lost during interdiction, the RDEIM model instead accounts for losses of GDP based on the industrial sectors located within a county. The original model includes costs for disposal of crops and milk that the RDEIM model currently does not, but these costs tend to contribute insignificantly to the overall losses. This document discusses three verification exercises to demonstrate that the RDEIM model is implemented correctly in MACCS. It also describes a benchmark study at five nuclear power plants chosen to represent the spectrum of U.S. commercial sites. The benchmarks provide perspective on the expected differences between the RDEIM and the original cost-based economic loss models. The RDEIM model is shown to consistently predict larger losses than the original model, probably in part because it accounts for national losses by including indirect and induced losses; whereas, the original model only accounts for regional losses. Nonetheless, the RDEIM model predicts losses that are remarkably consistent with the original cost-based model, differing by 16% at most for the five sites combined with three source terms considered in this benchmark.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Telecommuting Best Practices

Telecommuting at Sandia and within the Federal workforce has been optional for years. With the COVID-19 crisis, social distancing makes this a necessity that may be with us for some weeks and even months to come. All of us - whether new to telecommuting or an experienced remote worker - are challenged with how to efficiently and effectively adapt to this new work environment, while maintaining work-life balance to adequately care for ourselves and loved ones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗