Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Threshold Estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Clustering of red sequence galaxies in the fourth data release of the Kilo-Degree Survey

We present a sample of luminous red sequence galaxies as the basis for a study of the large-scale structure in the fourth data release of the Kilo-Degree Survey. The selected galaxies are defined by a red sequence template, in the form of a data-driven model of the colour-magnitude relation conditioned on redshift. In this work, the red sequence template was built using the broad-band optical+near infrared photometry of KiDS-VIKING and the overlapping spectroscopic data sets. The selection process involved estimating the red sequence redshifts, assessing the purity of the sample and estimating the underlying redshift distributions of redshift bins. After performing the selection, we mitigated the impact of survey properties on the observed number density of galaxies by assigning photometric weights to the galaxies. We measured the angular two-point correlation function of the red galaxies in four redshift bins and constrain the large-scale bias of our red sequence sample assuming a fixed ΛCDM cosmology. We find consistent linear biases for two luminosity-threshold samples (‘dense’ and ‘luminous’). We find that our constraints are well characterised by the passive evolution model.

79 ASTRONOMY AND ASTROPHYSICS↗

Heavy-meson decay constants from QCD sum rules

We sketch a recent sum-rule extraction of the decay constants of the heavy pseudoscalar mesons D, D{sub s}, B, and B{sub s} from the two-point correlator of heavy-light pseudoscalar currents. Our main emphasis lies on the control over all the uncertainties in the decay constants, related both to the input QCD parameters and to the limited accuracy of the method of sum rules. Gaining this control has become possible by application of our new procedure of extracting hadron observables based on a dual threshold depending on the Borel parameter. For the charmed-meson decay constants, we find fD = (206.2{+-}7.3{sub (OPE)}{+-}5.1{sub (syst)}) MeV, fD{sub s} = (245.3{+-}15.7{sub (OPE)}{+-}4.5{sub (syst)}) MeV. For the beauty mesons, the decay constants turn out to be extremely sensitive to the precise value of the {ovr MS} mass of the b-quark, {bar m}{sub b}({bar m}{sub b}). By requiring our sum-rule estimate to match the average of the lattice determinations of f{sub B}, we extract the rather accurate value {bar m}{sub b}({bar m}{sub b}) = (4.245{+-}0.025) GeV. Feeding this parameter value into our sum-rule formalism leads to the beauty-meson decay constants fB = (193.4{+-}12.3{sub (OPE)}{+-}4.3{sub (syst)}) MeV, fB{sub s} = (232.5{+-}18.6{sub (OPE)}{+-}2.4{sub (syst)}) MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 2 Ms Chandra Deep Field-North Survey and the 250 Ks extended Chandra Deep Field-South Survey: Improved point-source catalogs

We present improved point-source catalogs for the 2 Ms Chandra Deep Field-North (CDF-N) and the 250 ks Extended Chandra Deep Field-South (E-CDF-S) Surveys, implementing a number of recent improvements in Chandra source-cataloging methodology. For CDF-N/E-CDF-S, we provide a main catalog that contains 683/1003 X-ray sources detected with wavdetect at a false-positive probability threshold of 10{sup −5} that also satisfy a binomial-probability source-selection criterion of P<0.004/P < 0.002. Such an approach maximizes the number of reliable sources detected: a total of 196/275 main-catalog sources are new compared to the Alexander et al. CDF-N/Lehmer et al. E-CDF-S main catalogs. We also provide CDF-N/E-CDF-S supplementary catalogs that consist of 72/56 sources detected at the same wavdetect threshold and having P of 0.004–0.1/0.002–0.1 and K{sub s}⩽22.9/K{sub s}⩽22.3 mag counterparts. For all ≈1800 CDF-N and E-CDF-S sources, including the ≈500 newly detected ones (these being generally fainter and more obscured), we determine X-ray source positions utilizing centroid and matched-filter techniques; we also provide multiwavelength identifications, apparent magnitudes of counterparts, spectroscopic and/or photometric redshifts, basic source classifications, and estimates of observed active galactic nucleus and galaxy source densities around respective field centers. Simulations show that both the CDF-N and E-CDF-S main catalogs are highly reliable and reasonably complete. Background and sensitivity analyses indicate that the on-axis mean flux limits reached represent a factor of ≈1.5–2.0 improvement over the previous CDF-N and E-CDF-S limits. We make our data products publicly available.

79 ASTRONOMY AND ASTROPHYSICS↗

Relationship between edge localized mode severity and electron transport in the National Spherical Torus Experiment

n the National Spherical Torus Experiment [J. Menard , Nucl. Fusion 47, S645 (2007)], "giant" edge localized modes (ELMs) can occur resulting in a loss of plasma stored energy of up to 30%. These events are distinct from type I ELMs, whose energy loss is typically 4-10%, and they are accompanied by a cold pulse that causes a global decrease in the electron temperature profile. Estimates of the electron thermal transport during the cold pulses show a large enhancement over the underlying cross-field thermal diffusivity, chi(e), of up to several tens of m(2)/s. Following the ELM, short-wavelength fluctuations increase in the plasma edge and core, corresponding to an increase in the electron temperature gradient from the propagating cold pulse. Fast electron temperature measurements indicate that the normalized electron temperature scale length, R/L-Te, reaches the threshold value for instability predicted by a fit to linear stability calculations. This is observed on time scales that match the growth of the high-k fluctuations in the plasma core, indicating that the enhanced chi(e) and energy loss from the "giant" ELM appears to be related to critical gradient physics and the destabilization of electron temperature gradient modes. (C) 2008 American Institute of Physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

BINARY COMPACT OBJECT COALESCENCE RATES: THE ROLE OF ELLIPTICAL GALAXIES

In this paper, we estimate binary compact object merger detection rates for LIGO, including the potentially significant contribution from binaries that are produced in elliptical galaxies near the epoch of peak star formation. Specifically, we convolve hundreds of model realizations of elliptical- and spiral-galaxy population syntheses with a model for elliptical- and spiral-galaxy star formation history as a function of redshift. Our results favor local merger rate densities of 4 x 10{sup -3} Mpc{sup -3} Myr{sup -1} for binary black holes (BHs), 3 x 10{sup -2} Mpc{sup -3} Myr{sup -1} for binary neutron stars (NSs), and 10{sup -2} Mpc{sup -3} Myr{sup -1} for BH-NS binaries. We find that mergers in elliptical galaxies are a significant fraction of our total estimate for BH-BH and BH-NS detection rates; NS-NS detection rates are likely dominated by the contribution from spiral galaxies. Limiting attention to elliptical-galaxy plus only those spiral-galaxy models that reproduce current observations of Galactic NS-NS, we find slightly higher rates for NS-NS and largely similar ranges for BH-NS and BH-BH binaries. Assuming a detection signal-to-noise ratio threshold of 8 for a single detector (in practice as part of a network, to reduce its noise), corresponding to radii D {sub bns} of the effective volume inside of which a single LIGO detector could observe the inspiral of two 1.4 M {sub sun} NSs of 14 Mpc and 197 Mpc, for initial and advanced LIGO, we find event rates of any merger type of 2.9 x 10{sup -2}-0.46 and 25-400 yr{sup -1} (at 90% confidence level), respectively. We also find that the probability P {sub detect} of detecting one or more mergers with this single detector can be approximated by (1) P {sub detect} {approx_equal} 0.4 + 0.5 log(T/0.01 yr), assuming D {sub bns} = 197 Mpc and it operates for T yr, for T between 2 days and 0.1 yr, or by (2) P {sub detect} {approx_equal} 0.5 + 1.5 log(D {sub bns}/32 Mpc), for 1 yr of operation and for D {sub bns} between 20 and 70 Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

HOW THERMAL EVOLUTION AND MASS-LOSS SCULPT POPULATIONS OF SUPER-EARTHS AND SUB-NEPTUNES: APPLICATION TO THE KEPLER-11 SYSTEM AND BEYOND

We use models of thermal evolution and extreme ultraviolet (XUV) driven mass loss to explore the composition and history of low-mass, low-density transiting planets. We investigate the Kepler-11 system in detail and provide estimates of both the current and past planetary compositions. We find that an H/He envelope on Kepler-11b is highly vulnerable to mass loss. By comparing to formation models, we show that in situ formation of the system is extremely difficult. Instead we propose that it is a water-rich system of sub-Neptunes that migrated from beyond the snow line. For the broader population of observed planets, we show that there is a threshold in bulk planet density and incident flux above which no low-mass transiting planets have been observed. We suggest that this threshold is due to the instability of H/He envelopes to XUV-driven mass loss. Importantly, we find that this mass-loss threshold is well reproduced by our thermal evolution/contraction models that incorporate a standard mass-loss prescription. Treating the planets' contraction history is essential because the planets have significantly larger radii during the early era of high XUV fluxes. Over time low-mass planets with H/He envelopes can be transformed into water-dominated worlds with steam envelopes or rocky super-Earths. Finally, we use this threshold to provide likely minimum masses and radial-velocity amplitudes for the general population of Kepler candidates. Likewise, we use this threshold to provide constraints on the maximum radii of low-mass planets found by radial-velocity surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the dark cusp in the galactic center by long-period binaries

Massive black holes (MBHs) in galactic nuclei are believed to be surrounded by a high-density stellar cluster, whose mass is mostly in hard-to-detect faint stars and compact remnants. Such dark cusps dominate the dynamics near the MBH: a dark cusp in the Galactic center (GC) of the Milky Way would strongly affect orbital tests of general relativity there; on cosmic scales, dark cusps set the rates of gravitational wave emission events from compact remnants that spiral into MBHs, and they modify the rates of tidal disruption events, to list only some implications. A recently discovered long-period massive young binary (with period P {sub 12} ≲ 1 yr, total mass M{sub 12}∼O(100 M{sub ⊙}), and age T {sub 12} ∼ 6 × 10{sup 6} yr), only ∼0.1 pc from the Galactic MBH, sets a lower bound on the stellar two-body relaxation timescale there, min t {sub rlx}∝(P {sub 12}/M {sub 12}){sup 2/3} T {sub 12} ∼ 10{sup 7} yr, and, correspondingly, an upper bound on the stellar number density, maxn{sub ⋆}∼few×10{sup 8}/〈M{sub ⋆}{sup 2}〉 pc{sup −3} (〈M{sub ⋆}{sup 2}〉{sup 1/2} is the rms stellar mass), based on the binary's survival against evaporation by the dark cusp. However, a conservative dynamical estimate, the drain limit, implies t{sub rlx}>O(10{sup 8} yr). Such massive binaries are thus too short-lived and tightly bound to constrain a dense relaxed dark cusp. We explore here in detail the use of longer-period, less massive, and longer-lived binaries (P {sub 12} ∼ few yr, M {sub 12} ∼ 2-4 M {sub ☉}, T {sub 12} ∼ 10{sup 8}-10{sup 10} yr), presently just below the detection threshold, for probing the dark cusp and develop the framework for translating their future detections among the giants in the GC into dynamical constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRA-16: Development of a Radiation Monitoring Device Using a Low-Cost CCD Camera Following Radionuclide Therapy

Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Apple iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.

60 APPLIED LIFE SCIENCES↗

Silent Aircraft Initiative Concept Risk Assessment

A risk assessment of the Silent Aircraft Initiative's SAX-40 concept design for extremely low noise has been performed. A NASA team developed a list of 27 risk items, and evaluated the level of risk for each item in terms of the likelihood that the risk would occur and the consequences of the occurrence. The following risk items were identified as high risk, meaning that the combination of likelihood and consequence put them into the top one-fourth of the risk matrix: structures and weight prediction; boundary-layer ingestion (BLI) and inlet design; variable-area exhaust and thrust vectoring; displaced-threshold and continuous descent approach (CDA) operational concepts; cost; human factors; and overall noise performance. Several advanced-technology baseline concepts were created to serve as a basis for comparison to the SAX-40 concept. These comparisons indicate that the SAX-40 would have significantly greater research, development, test, and engineering (RDT&E) and production costs than a conventional aircraft with similar technology levels. Therefore, the cost of obtaining the extremely low noise capability that has been estimated for the SAX-40 is significant. The SAX-40 concept design proved successful in focusing attention toward low noise technologies and in raising public awareness of the issue.

Nickol, Craig L.↗

Ionization equilibrium at the transition from valence-band to acceptor-band migration of holes in boron-doped diamond

A quasi-classical model of ionization equilibrium in the p-type diamond between hydrogen-like acceptors (boron atoms which substitute carbon atoms in the crystal lattice) and holes in the valence band (v-band) is proposed. The model is applicable on the insulator side of the insulator–metal concentration phase transition (Mott transition) in p-Dia:B crystals. The densities of the spatial distributions of impurity atoms (acceptors and donors) and of holes in the crystal are considered to be Poissonian, and the fluctuations of their electrostatic potential energy are considered to be Gaussian. The model accounts for the decrease in thermal ionization energy of boron atoms with increasing concentration, as well as for electrostatic fluctuations due to the Coulomb interaction limited to two nearest point charges (impurity ions and holes). The mobility edge of holes in the v-band is assumed to be equal to the sum of the threshold energy for diffusion percolation and the exchange energy of the holes. On the basis of the virial theorem, the temperature T{sub j} is determined, in the vicinity of which the dc band-like conductivity of holes in the v-band is approximately equal to the hopping conductivity of holes via the boron atoms. For compensation ratio (hydrogen-like donor to acceptor concentration ratio) K ≈ 0.15 and temperature T{sub j}, the concentration of “free” holes in the v-band and their jumping (turbulent) drift mobility are calculated. Dependence of the differential energy of thermal ionization of boron atoms (at the temperature 3T{sub j}/2) as a function of their concentration N is calculated. The estimates of the extrapolated into the temperature region close to T{sub j} hopping drift mobility of holes hopping from the boron atoms in the charge states (0) to the boron atoms in the charge states (−1) are given. Calculations based on the model show good agreement with electrical conductivity and Hall effect measurements for p-type diamond with boron atom concentrations in the range from 3 × 10{sup 17} to 3 × 10{sup 20 }cm{sup −3}, i.e., up to the Mott transition. The model uses no fitting parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computationally efficient and error aware surrogate construction for numerical solutions of subsurface flow through porous media

Limiting the injection rate to restrict the pressure below a threshold at a critical location can be an important goal of simulations that model the subsurface pressure between injection and extraction wells. The pressure is approximated by the solution of Darcy’s partial differential equation for a given permeability field. The subsurface permeability is modeled as a random field since it is known only up to statistical properties. This induces uncertainty in the computed pressure. Solving the partial differential equation for an ensemble of random permeability simulations enables estimating a probability distribution for the pressure at the critical location. These simulations are computationally expensive, and practitioners often need rapid online guidance for real-time pressure management. An ensemble of numerical partial differential equation solutions is used to construct a Gaussian process regression model that can quickly predict the pressure at the critical location as a function of the extraction rate and permeability realization. The Gaussian process surrogate analyzes the ensemble of numerical pressure solutions at the critical location as noisy observations of the true pressure solution, enabling robust inference using the conditional Gaussian process distribution. Our first novel contribution is to identify a sampling methodology for the random environment and matching kernel technology for which fitting the Gaussian process regression model scales as O ( n log n ) instead of the typical O ( n 3 ) rate in the number of samples n used to fit the surrogate. The surrogate model allows almost instantaneous predictions for the pressure at the critical location as a function of the extraction rate and permeability realization. Our second contribution is a novel algorithm to calibrate the uncertainty in the surrogate model to the discrepancy between the true pressure solution of Darcy’s equation and the numerical solution. Finally, although our method is derived for building a surrogate for the solution of Darcy’s equation with a random permeability field, the framework broadly applies to solutions of other partial differential equations with random coefficients.

54 ENVIRONMENTAL SCIENCES↗

Simulated performance of an ultracold ion source

At present, the smallest spot size which can be achieved with state-of-the-art focused ion beam (FIB) technology is mainly limited by the chromatic aberrations associated with the 4.5 eV energy spread of the liquid-metal ion source. Here we numerically investigate the performance of an ultracold ion source which has the potential for generating ion beams which combine high brightness with small energy spread. The source is based on creating very cold ion beams by near-threshold photoionization of a laser-cooled and trapped atomic gas. We present ab initio numerical calculations of the generation of ultracold beams in a realistic acceleration field and including all Coulomb interactions, i.e., both space charge effects and statistical Coulomb effects. These simulations demonstrate that with existing technology reduced brightness values exceeding 10{sup 5} A m{sup -2} sr{sup -1} V{sup -1} are feasible at an energy spread as low as 0.1 eV. The estimated spot size of the ultracold ion source in a FIB instrument ranges from 10 nm at a current of 100 pA to 0.8 nm at 1 pA.

43 PARTICLE ACCELERATORS↗

Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental limitations of high contrast imaging set by small sample statistics

In this paper, we review the impact of small sample statistics on detection thresholds and corresponding confidence levels (CLs) in high-contrast imaging at small angles. When looking close to the star, the number of resolution elements decreases rapidly toward small angles. This reduction of the number of degrees of freedom dramatically affects CLs and false alarm probabilities. Naively using the same ideal hypothesis and methods as for larger separations, which are well understood and commonly assume Gaussian noise, can yield up to one order of magnitude error in contrast estimations at fixed CL. The statistical penalty exponentially increases toward very small inner working angles. Even at 5-10 resolution elements from the star, false alarm probabilities can be significantly higher than expected. Here we present a rigorous statistical analysis that ensures robustness of the CL, but also imposes a substantial limitation on corresponding achievable detection limits (thus contrast) at small angles. This unavoidable fundamental statistical effect has a significant impact on current coronagraphic and future high-contrast imagers. Finally, the paper concludes with practical recommendations to account for small number statistics when computing the sensitivity to companions at small angles and when exploiting the results of direct imaging planet surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Quenching of supermassive black hole growth around the apparent maximum mass

Recent quasar surveys have revealed that supermassive black holes (SMBHs) rarely exceed a mass of M {sub BH} ∼ a few × 10{sup 10} M{sub ⊙} during the entire cosmic history. It has been argued that quenching of the BH growth is caused by a transition of a nuclear accretion disk into an advection-dominated accretion flow, with which strong outflows and/or jets are likely to be associated. We investigate the relationship between the maximum mass of SMBHs and the radio-loudness of quasars with a well-defined sample of ∼10{sup 5} quasars at a redshift range of 0 < z < 2, obtained from the Sloan Digital Sky Surveys DR7 catalog. We find that the number fraction of the radio-loud (RL) quasars increases above a threshold of M {sub BH} ≃ 2 × 10{sup 9} M{sub ⊙}, independent of their redshifts. Moreover, the number fraction of RL quasars with lower Eddington ratios (out of all RL quasars), indicating lower accretion rates, increases above the critical BH mass. These observational trends can be natural consequences of the proposed scenario of suppressing BH growth around the apparent maximum mass of ∼10{sup 10} M{sub ⊙}. The ongoing VLA Sky Survey in radio will allow us to estimate of the exact number fraction of RL quasars more precisely, which gives further insight into the quenching processes for BH growth.

79 ASTRONOMY AND ASTROPHYSICS↗

An Enhanced Model for Evaluating Failure Propagation in Launch Vehicle Engine Sections

An important component in the assessment of launch vehicle safety is the estimation of the likelihood of large-scale explosions given the existence of failures that manifest as a localized energy release. A failure propagation model is presented for simulating cascading failures of energetic components in proximity where the primary modes of energy transfer are fragments/shrapnel and blast overpressure. The model is an extension of the model developed by Mathias and Motiwala (2015) [1] with enhancements to include the effects of fragment ricochet, fragment drag, fragment ballistic limit equation thresholds, and blast impulse thresholds. A series of sensitivity studies were conducted for a generic launch vehicle engine section and results are presented that illustrate the effects of the model modifications.

Susie Go↗

An Enhanced Model for Evaluating Failure Propagation in Launch Vehicle Engine Sections

An important component in the assessment of launch vehicle safety is the estimation of the likelihood of large-scale explosions given the existence of failures that manifest as a localized energy release. A failure propagation model is presented for simulating cascading failures of energetic components in proximity where the primary modes of energy transfer are fragments/shrapnel and blast overpressure. The model is an extension of the model developed by Mathias and Motiwala (2015) [1] with enhancements to include the effects of fragment ricochet, fragment drag, fragment ballistic limit equation thresholds, and blast impulse thresholds. A series of sensitivity studies were conducted for a generic launch vehicle engine section and results are presented that illustrate the effects of the model modifications.

Susie Go↗

Respirator Cartridge Performance on Mixed Vapors from Hanford Tank Headspaces and Exhausters - 20427

Between 2016 and 2018, the Hanford Tank Operations Contractor - Washington River Protection Solutions (WRPS) - conducted a series of tests of air-purifying respirator (APR) chemical cartridges commonly used at Hanford tank farms to determine the period of time for which the cartridges would provide adequate performance when used in APRs and powered-air-purifying respirators (PAPRs) to protect workers when exposed to a mixture of vapors exiting tank headspaces. Although cartridge manufacturers provide service life estimating tools for individual chemical compounds, the projected performance of these cartridges on complex vapor mixtures is not available, and the adequacy of APRs for tank farm applications represents an important workforce concern. The Occupational Safety and Health Administration identifies cartridge testing as a valid approach for establishing cartridge service life. The primary function of the WRPS Cartridge Test Program was to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford tank farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis of and recommendations based on respirator cartridge performance. A total of 28 APR and 10 PAPR cartridge tests were conducted between 2016 and 2018 on 12 different tank headspaces and tank farm exhauster slipstreams. Two APR cartridges from SCOTT (now 3M) and two PAPR cartridges from MSA Safety, Inc. and 3M were evaluated using a cartridge testing system specifically designed to measure and monitor test conditions and sample cartridge inlet and outlet vapor streams for important chemical compounds. Testing focused on analysis of approximately 61 tank vapor chemicals of potential concern (COPCs) that have been previously detected in tank vapors at levels above 10% of their occupational exposure limits (OELs). Each test was conducted over 16 hours of run time. Evidence of chemical breakthrough was assessed by comparing inlet and outlet COPC concentrations over the duration of each test. The breakthrough threshold was normally defined as exceeding 10% of the compounds OEL at the cartridge outlet. Ammonia breakthrough was observed in a majority of the cartridge tests and occurred earlier than breakthrough of any other chemical compound. Several other COPCs did exhibit breakthrough behavior, including mercury, 1,3-butadiene, furan, 2,5 dihydrofuran, and N-nitrosodimethylamine (NDMA), but only in a very limited number of cartridge tests and only after ammonia breakthrough had occurred. In addition, tests results suggest that breakthrough of some of these COPCs may have been affected by competition with and breakthrough of other non-COPC organics, such as ethanol and acetone, with substantially lower toxicological hazard. Comparison of cartridge manufacturers' service life estimates with the experimentally derived breakthrough times indicates that manufacturers' estimates are generally conservative, even in the presence of the complex mixed vapor streams experienced in these tests. With consideration of appropriate safety margins, these results provide valuable insights on cartridge performance to inform industrial hygiene professionals in establishing appropriate cartridge change-out schedules for APR and PAPR use in the Hanford tank farms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗