Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Stochastic joint inversion of hydrogeophysical data for salt tracer test monitoring and hydraulic conductivity imaging

The assessment of hydraulic conductivity of heterogeneous aquifers is a difficult task using traditional hydrogeological methods (e.g., steady state or transient pumping tests) due to their low spatial resolution. Geophysical measurements performed at the ground surface and in boreholes provide additional information for increasing the resolution and accuracy of the inverted hydraulic conductivity field. We used a stochastic joint inversion of Direct Current (DC) resistivity and Self-Potential (SP) data plus in situ measurement of the salinity in a downstream well during a synthetic salt tracer experiment to reconstruct the hydraulic conductivity field between two wells. The pilot point parameterization was used to avoid over-parameterization of the inverse problem. Bounds on the model parameters were used to promote a consistent Markov chain Monte Carlo sampling of the model parameters. To evaluate the effectiveness of the joint inversion process, we compared 8 cases in which the geophysical data are coupled or not to the in situ sampling of the salinity to map the hydraulic conductivity. We first tested the effectiveness of the inversion of each type of data alone (concentration sampling, self-potential, and DC resistivity), and then we combined the data two by two. We finally combined all the data together to show the value of each type of geophysical data in the joint inversion process because of their different sensitivity map. We also investigated a case in which the data were contaminated with noise and the variogram unknown and inverted stochastically. The results of the inversion revealed that incorporating the self-potential data improves the estimate of hydraulic conductivity field especially when the self-potential data were combined to the salt concentration measurement in the second well or to the time-lapse cross-well electrical resistivity data. Various tests were also performed to quantify the uncertainty in the inverted hydraulic conductivity field.

54 ENVIRONMENTAL SCIENCES↗

Automated qualification data tool for high temperature metallic materials

This report describes a framework for storing, processing, and displaying qualification data for high temperature mechanical properties. The framework automates the process of generating design data from mechanical test results, for example for a data qualification report for the ASME Boiler \& Pressure Vessel Code. The framework has three parts: a data storage model with common formats for several types of typical mechanical property tests, a backend based on the \pycreep Python library for correlating and extrapolating the data to generate design material properties and allowable stresses, and a demonstration user interface for displaying, sorting, and filtering the data and exploring different options for modeling the design mechanical properties. The report discusses the options available for data processing, with illustrations from real test data on Alloy 617, Alloy 709, Alloy 740H, and Laser-Powder Bed Fusion 316H. The framework is complete for ASME type data analysis and will be used to store test data generated by the Department of Energy, Office of Nuclear Energy, Advanced Materials and Manufacturing Technologies sponsored qualification programs. Future work could extend the tool to other types of material properties and/or expand the demo user interface to make it accessible across the AMMT program.

36 MATERIALS SCIENCE↗

Accelerated Creep Test Qualification of Creep-Resistance Using the Wilshire–Cano–Stewart Constitutive Model and Stepped Isostress Method

In this paper, a qualification of accelerated creep-resistance of Inconel 718 is assessed using the novel Wilshire–Cano–Stewart (WCS) model and the stepped isostress method (SSM) and predictions are made to conventional creep data. Conventional creep testing is a long-term continuous process; in fact, the ASME B&PV III requires that 10,000+ h of experiments must be conducted to each heat for materials employed in boilers and/or pressure vessel components. This process is costly and not feasible for rapid development of new materials. As an alternative, accelerated creep testing techniques have been developed to reduce the time needed to characterize the creep resistance of materials. Most techniques are based upon the time-temperature-stress superposition principle that predicts minimum-creep-strain-rate (MCSR) and stress-rupture behaviors but lack the ability to predict creep deformation and consider deformation mechanisms that occur for experiments of longer duration. The SSM has been developed, which enables the prediction of creep deformation response as well as reduce the time needed for qualification of materials. The SSM approach has been successful for polymer, polymeric composites, and recently has been introduced for metals. In this study, the WCS constitutive model, calibrated to SSM test data, qualifies the creep resistance of Inconel 718 at 750 °C and predictions are compared to conventional creep testing data. The WCS model has proven to make long-term predictions for stress-rupture, MCSR, creep deformation, and damage in metallic materials. The SSM varies stress levels after time interval adding damage to the material, which can be tracked by the WCS model. The SSM data is calibrated into the model and the WCS model generates realistic predictions of stress-rupture, MSCR, damage, and creep deformation. The calibrated material constants are used to generate predictions of stress-rupture and are postaudit validated using the National Institute of Material Science database. Similarly, the MCSR predictions are compared from previous studies. Finally, the creep deformation predictions are compared with real data and is determined that the results are well in between the expected boundaries. Material characterization and mechanical properties can be determined at a faster rate and with a more cost-effective method. This is beneficial for multiple applications such as in additive manufacturing, composites, spacecraft, and industrial gas turbines.

42 ENGINEERING↗

Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10 -5 kg s -1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4 + km 2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1 σ ), when measurements are averaged over 2 min. The results of the synthetic and field data testing show that the new observing system and statistical approach greatly decreases the incidence of false alarms (that is, wrongly identifying a well site to be leaking) compared with the same tests that do not use the NZMB approach and therefore offers increased leak detection and sizing capabilities.

03 NATURAL GAS↗

Hydroshear Simulation Lab Test 2

This data file is for test 2. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details can be found on the spreadsheets--note that there are 2 spreadsheets

15 GEOTHERMAL ENERGY↗

FY 2016 Status Report: Documentation of All CIRFT Data including Hydride Reorientation Tests (Draft M2)

The first portion of this report provides a detailed description of fiscal year (FY) 2015 test result corrections and analysis updates based on FY 2016 updates to the Cyclic Integrated Reversible-Bending Fatigue Tester (CIRFT) program methodology, which is used to evaluate the vibration integrity of spent nuclear fuel (SNF) under normal conditions of transport (NCT). The CIRFT consists of a U-frame test setup and a real-time curvature measurement method. The three-component U-frame setup of the CIRFT has two rigid arms and linkages connecting to a universal testing machine. The curvature SNF rod bending is obtained through a three-point deflection measurement method. Three linear variable differential transformers (LVDTs) are clamped to the side connecting plates of the U-frame and used to capture deformation of the rod. The second portion of this report provides the latest CIRFT data, including data for the hydride reorientation test. The variations in fatigue life are provided in terms of moment, equivalent stress, curvature, and equivalent strain for the tested SNFs. The equivalent stress plot collapsed the data points from all of the SNF samples into a single zone. A detailed examination revealed that, at the same stress level, fatigue lives display a descending order as follows: H. B. Robinson Nuclear Power Station (HBR), LMK, and mixed uranium-plutonium oxide (MOX). Just looking at the strain, LMK fuel has a slightly longer fatigue life than HBR fuel, but the difference is subtle. The third portion of this report provides finite element analysis (FEA) dynamic deformation simulation of SNF assemblies . In a horizontal layout under NCT, the fuel assembly’s skeleton, which is formed by guide tubes and spacer grids, is the primary load bearing apparatus carrying and transferring vibration loads within an SNF assembly. These vibration loads include interaction forces between the SNF assembly and the canister basket walls. Therefore, the integrity of the guide tubes and spacer grids critically affects the vibration intensity of the fuel assembly during transport and must be considered when developing the multipurpose purpose canister (MPC) design for safe SNF transport.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

STANDARDIZATION OF CEBAF 12 GEV UPGRADE CAVITY TESTING

CEBAF 12GeV upgrade project includes 80 new 7-cell cavities to form 10 cryomodules. Each cavity underwent RF qualification at 2.07K using a high power accelerating gradient test and an HOM survey in Jefferson Lab's Vertical Testing Area (VTA) before cavity string assembly. In order to ensure consistently high quality data, updated cavity testing procedures and analysis were implemented and used by a group of VTA operators. For high power tests, a cavity testing procedure was developed and used in conjunction with a LabVIEW program to collect the test data. Additionally while the cavity was at 2.07K, an HOM survey was performed using a network analyzer and a combination of Excel and Mathematica programs. Data analysis was standardized and an online logbook, Pansophy, was used for data storage and mining. The Pansophy system allowed test results to be easily summarized and searchable across all cavity tests. In this presentation, the CEBAF 12GeV upgrade cavity testing procedure, method for data analysis, and results reporting results will be discussed.

43 PARTICLE ACCELERATORS↗

Securing Operating Data From Passive Safety Tests at the Fast Flux Test Facility

The Fast Flux Test Facility (FFTF) is the most recent Liquid Metal Reactor (LMR) to operate in the United States, from 1982 to 1992. The technologies employed in designing and constructing this reactor, along with information obtained from tests conducted during its operation, are currently being secured and archived by the Department of Energy’s Office of Nuclear Energy Fuel Cycle Research and Development Program. This report is one in a series documenting the overall project efforts to retrieve and preserve critical information related to advanced reactors. A previous report summarized the initial efforts to review, retrieve and preserve the most salient documents related to Passive Safety Testing (PST) in the FFTF. Efforts continue to locate, secure, and retrieve record copies of original plant data tapes for the series of passive safety tests conducted between 1986 and 1991.

data preservation↗

Proxy-based Bayesian inversion of strain tensor data measured during well tests

Recent instrument developments have made it possible to measure the strain tensor caused by injecting or pumping fluid from aquifers or reservoirs, but the full value of these data is limited because the long runtimes of poroelastic forward models makes it impractical to use many inversion schemes. This limits the interpretation of strain data for managing the recovery of resources or storage of wastes in the subsurface. This paper describes a method of inverting deformation data using a poroelastic numerical simulator so the results can be used to manage reservoirs or aquifers. We developed a workflow designed to reduce the number of simulations sufficiently to make it feasible to use DREAMzs, an advanced Bayesian inversion method that translates the uncertainties from different sources into unbiased posterior parameter distributions and uncertainty envelopes around the field data. Using a KNN proxy model for the poroelastic simulator is key to reducing the overall computations, and the workflow includes a strategy for ensuring the proxy model results converge on the results from the simulator. The workflow is tested using an idealized example that verifies the ability to correctly identify parameters and characterize noise used to perturb the data. Field data from an injection test at an oil reservoir near Tulsa, Oklahoma, are also used to evaluate the efficacy of the workflow with a real dataset. The workflow identified 265 history matching solutions out of 1240 total simulation runs (21% acceptance ratio), where the results were used to characterize posterior parameter distribution and evaluate the prediction uncertainty. Furthermore, this workflow is significant because it enables strain tensor, or other geomechanical measurements to be interpreted to guide decision-making during energy and environmental processes in the subsurface.

42 ENGINEERING↗

Utah FORGE: Neubrex Well 16B(78)-32 Circulation Test Fiber Optics Monitoring Data and Reports - July, 2023

This dataset features Distributed Acoustic Sensing (DAS) and fiber optics monitoring data acquired by Neubrex Energy Services during the Utah FORGE Well 16B(78)-32 circulation test in July 2023. DAS and fiber optic monitoring data include absolute strain, strain change, strain change rate, distributed temperature sensing (DTS), and frequency band extraction (FBE). Data processing was completed between September and October 2023. The dataset includes the fiber optic sensing data collected during these operations, along with a data collection report, descriptions of the data, and instructions for reading the data files.

15 GEOTHERMAL ENERGY↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

Investigation and Diagnosis of Faulty Data Channels in CMS Outer Tracker Module Testing

The High-Luminosity Large Hadron Collider (HL-LHC) is currently undergoing upgrades to improve its luminosity. In parallel, this requires an upgrade to the Compact Muon Solenoid (CMS)’s Outer Tracker, consisting of Pixel-Strip (PS) and Strip-Strip (2S) modules that can accurately track the path of charged particles originating from the collisions. It follows that such complex modules call for extensive testing, requiring a sophisticated Data Acquisition (DAQ) system that can perform specific tests to assess their performance. In addition, errors caused by the hardware of a given testing station, and its associated data channel, need to be accurately identified to guarantee proper testing of modules. We have developed a software extension to the Phase-II Outer Tracker Analyzer of Test Outputs (POTATO), which is a specialized software designed to analyze and grade all of the module tests through a centralized database. This extension categorizes and analyzes module test results by its station and data channel. Its analysis can be used to identify trends in grading that indicate issues in these channels’ grading process rather than in the individual modules. This poster shows our methodology and results for identifying faulty data channels. Using this extension, we can quickly diagnose and address problems in our DAQ system, ensuring proper evaluation corrections for each module.

Chen, Angus [Fermilab]↗

Test Plan for Solvent Extraction Data Acquisition to Support Modeling Efforts

This testing will support NEAMS SafeSep Modeling efforts related to droplet simulation in liquid-liquid extraction equipment. Physical characteristic determinations will be completed for the fluids being used in the experiment including viscosity, density, surface tension, distribution coefficients, and diffusion coefficients. Then, experiments will be carried out to provide data for comparison to the simulation’s calculation of mass transfer coefficients. Experiments will be conducted with solutions used in the TRansUranic EXtraction (TRUEX) process extraction section. The TRUEX process was chosen since it is one solvent extraction system currently proposed for the separation of actinides and lanthanides from used nuclear fuel, it is diffusion limited, testing can be performed using non radioactive lanthanides to evaluate mass transfer. The extraction section involves transfer of one or more lanthanide species from an aqueous solution to an organic solvent. Single droplets rising by buoyancy will be studied first. Droplet size and number of species transferred will be varied independently to provide mass transfer coefficients as a function of each variable. An apparatus has been designed specifically for these experiments. In order to get more accurate measurements of droplet size, contact time, time of droplet formation, and possibly droplet breakup and coalescence, a high speed camera will be utilized for these experiments. Other potential experiments include examining the effects of jetted droplets and shear flow on the mass transfer coefficients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Financial Summary, Nanofiltration Data, and Lithium Uptake Data

Integrated testing of nanofiltration and lithium uptake subsystems using synthetic geothermal brine. Also includes a financial summary (Pro Forma) of the proposed 'Geothermal Thermoelectric Generation (G-TEG) with Integrated Temperature Driven Membrane Distillation and Novel Manganese Oxide for Lithium Extraction' (first pass 500 gpm).

15 GEOTHERMAL ENERGY↗

Coupons (mini-modules) experimental data

Adhesion testing results on mini-module coupons (cell/encapsulant/glass laminates) that were aged under the different accelerated aging conditions (outlined more in the DataHub URL).

accelerated aging↗

Results of a Soil Flushing Treatability Test for Hanford Site Hexavalent Chromium Removal - 20446

U.S. Department of Energy contractor CH2M Hill Plateau Remediation Company has made significant progress remediating hexavalent chromium in groundwater near the Columbia River through the operation of pump and treat facilities and source removal activities. To mitigate risks associated with hexavalent chromium contamination, which was identified in a CERCLA interim action record of decision as the primary groundwater contaminant of concern for the 100-KR-4 Operable Unit from discharging to the Columbia River, three ion-exchange pump and treat systems were installed between 1997 and 2009. Between 2010 and 2016, operation of the K West pump and treat system, located near the former 105K West plutonium production reactor, reduced concentrations below the groundwater remediation target for hexavalent chromium. In 2016, a rebound study was performed to evaluate the effectiveness of the pump and treat remedy and assess the potential for any residual hexavalent chromium sources continuing to contribute to groundwater contamination. As a result of the rebound study, a source of continued groundwater contamination was identified. To address this condition, a soil flushing treatability test was written and approved by the U.S. Department of Energy and the U.S. Environmental Protection Agency. The test included saturating about a 1-acre area of soil with treated water with the goal of forcing the residual hexavalent chromium to groundwater where existing extraction wells could remove it for treatment, accelerating the cleanup process. In spring and summer 2019, CH2M Hill Plateau Remediation Company installed and began operating a shallow underground leach system to support the treatability test. Preliminary sampling data show the test was effective in removing the residual contamination. Following further evaluation and analysis from the initial test, the process will be considered for implementation elsewhere on the Hanford Site, particularly at locations where there is a known or suspected continuing contamination source in the soil column. The paper will cover the goals of the study, as well as more details about the following: - Overview of pump and treat exit strategy (using U.S. Environmental Protection Agency guidance); - The design and installation of the soil flushing technology in the 100-K Area; - The testing process and results of sampling data; - Post-study evaluation and potential for implementation in other locations at the Hanford Site. Innovative solutions for cleanup, such as the soil flushing technology, have resulted in substantial progress in the removal of groundwater contaminants at the Hanford Site, potentially shortening the time frame required to meet cleanup goals and resulting in significant cost savings. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pathway modeling of microarray data: A case study of pathway activity changes in the testis following in utero exposure to dibutyl phthalate (DBP)

Pathway activity level analysis, the approach pursued in this study, focuses on all genes that are known to be members of metabolic and signaling pathways as defined by the KEGG database. The pathway activity level analysis entails singular value decomposition (SVD) of the expression data of the genes constituting a given pathway. We explore an extension of the pathway activity methodology for application to time-course microarray data. We show that pathway analysis enhances our ability to detect biologically relevant changes in pathway activity using synthetic data. As a case study, we apply the pathway activity level formulation coupled with significance analysis to microarray data from two different rat testes exposed in utero to Dibutyl Phthalate (DBP). In utero DBP exposure in the rat results in developmental toxicity of a number of male reproductive organs, including the testes. One well-characterized mode of action for DBP and the male reproductive developmental effects is the repression of expression of genes involved in cholesterol transport, steroid biosynthesis and testosterone synthesis that lead to a decreased fetal testicular testosterone. Previous analyses of DBP testes microarray data focused on either individual gene expression changes or changes in the expression of specific genes that are hypothesized, or known, to be important in testicular development and testosterone synthesis. However, a pathway analysis may inform whether there are additional affected pathways that could inform additional modes of action linked to DBP developmental toxicity. We show that Pathway activity analysis may be considered for a more comprehensive analysis of microarray data.

60 APPLIED LIFE SCIENCES↗

A waveform detector that targets template–decorrelated signals and achieves its predicted performance, Part I: Demonstration with IMS data

Here, waveform correlation detectors used in seismic monitoring scan multichannel data to test two competing hypotheses: that data contain (1) a noisy, amplitude-scaled version of a template waveform, or, (2) only noise. In reality, seismic wavefields include signals triggered by non-target sources (background seismicity) and targets signals that are only partially correlated with the waveform template.

47 OTHER INSTRUMENTATION↗