Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Effects of real-time thermal aging on graphite/polyimide composites

As part of a program to evaluate high-temperature advanced composites for use on supersonic cruise transport aircraft, two graphite/polyimide composites have been aged at elevated temperatures for times up to 5.7 years. Work on the first, HT-S/710 graphite/polyimide, was started in 1974. Evaluation of the second polyimide, Celion 6000/LARC-160, began in 1980. Baseline properties are presented, including unnotched and notched tensile data as a function of temperature, compression, flexure, shear, and constant-amplitude fatigue data at R = 0.1 and R = -1. Tensile specimens were aged in ovens where pressure and aging temperatures were controlled for various times up to and including 50,000 hours. Changes in tensile strength were determined and plotted as a function of aging time. The HT-S/710 composite aged at 450 F and 550 F if compared to the Celion 6000/LARC-160 composite aged at 350 F and 450 F. After tensile testing, many of the thermal aging specimens were examined using a scanning electron microscope. Results of these studies are presented, and changes in properties and degradation mechanisms during high-temperature aging are discussed and illustrated using metallographic techniques.

Haskins, J. F.↗

Mechanical properties of Inconel 718 and Nickel 201 alloys after thermal histories simulating brazing and high temperature service

An experimental investigation was made to evaluate two nickel base alloys (Nickel-201 and Inconel-718) in three heat treated conditions. These conditions were: (1) annealed; (2) after thermal exposure simulating a braze cycle; and (3) after a thermal exposure simulating a braze cycle plus one operational lifetime of high temperature service. For the Nickel-201, two different braze cycle temperatures were evaluated. A braze cycle utilizing a lower braze temperature resulted in less grain growth for Nickel-201 than the standard braze cycle used for joining Nickel-201 to Inconel-718. It was determined, however, that Nickel-201, was marginal for temperatures investigated due to large grain growth. After the thermal exposures described above, the mechanical properties of Nickel-201 were degraded, whereas similar exposure on Inconel-718 actually strengthened the material compared with the annealed condition. The investigation included tensile tests at both room temperature and elevated temperatures, stress-rupture tests, and metallographic examination.

James, W. F.↗

Effect of boron on tensile properties of B2 BeAl

Small additions of boron were shown to improve the room temperature ductility of the intermetallic compound Ni3Al. Boron is believed to segregate to the gain boundaries and strengthen them, allowing the inheret ductility of the grains to be achieved. The present study was undertaken to see if boron has a similar effect on the low temperature tensile properties of the equiatomic intermetallic compound FeAl. A binary alloy without boron is compared with an alloy containing 0.78 at % B (0.2 wt %) B, by tensile testing over the temperature range of 300 K to 640 K. Both alloys were processed by powder metallurgy. Results showed that 0.78 at % B addition to FeAl does indeed change the room temperature fracture mode from intergranular to transgranular, suggesting a strengthening of grain boundaries. The alloy containing boron is, however, still brittle at room temperature. A slight decrease in the ductile to brittle transition temperature is, nevertheless, observed. In addition a significant increase in strength of the alloy is observed with boron addition.

Crimp, M.↗

Yielding and deformation behavior of the single crystal nickel-base superalloy PWA 1480

Interrupted tensile tests were conducted to fixed plastic strain levels in 100 ordered single crystals of the nickel based superalloy PWA 1480. Testing was done in the range of 20 to 1093 C, at strain rate of 0.5 and 50%/min. The yield strength was constant from 20 to 760 C, above which the strength dropped rapidly and became a stong function of strain rate. The high temperature data were represented very well by an Arrhenius type equation, which resulted in three distinct temperature regimes. The deformation substructures were grouped in the same three regimes, indicating that there was a fundamental relationship between the deformation mechanisms and activation energies. Models of the yielding process were considered, and it was found that no currently available model was fully applicable to this alloy. It was also demonstrated that the initial deformation mechanism (during yielding) was frequently different from that which would be inferred by examining specimens which were tested to failure.

Milligan, W. W., Jr.↗

Graphite/PMR polyimide composites with improved toughness

The toughness of composites made with modified PMR (Polymerization of monomer reactants) polyimides and Celion 6000 graphite fibers was studied. Various types/levels of monomer reactants containing flexible links were incorporated into PMR resin compositions used to prepare composites. The composites were evaluated for toughness using instrumented drop weight and 10 deg off axis tensile tests at room temperature, and for strength using flexure and short beam shear tests at room temperature and at elevated temperature. The effect of resin composition on composite processability, thermo-oxidative stability, toughness and mechanical properties are discussed.

Vannucci, R. D.↗

Analysis of silicon stress/strain relationships

Results are presented for work on stress-strain relationships in silicon ribbon. Calculations of stress fields, dislocation desities, and buckling were made; uniaxial tensile tests were made on silicon at 1150 C; and dislocation motion studies were performed.

Dillon, O.↗

Yielding and deformation behavior of the single crystal superalloy PWA 1480

Interrupted tensile tests were conducted to fixed plastic strain levels in 100 ordered single crystals of the nickel based superalloy PWA 1480. Testing was done in the range of 20 to 1093 C, at strain rate of 0.5 and 50 percent/min. The yield strength was constant from 20 to 760 C, above which the strength dropped rapidly and became a strong function of strain rate. The high temperature data were represented very well by an Arrhenius type equation, which resulted in three distinct temperature regimes. The deformation substructures were grouped in the same three regimes, indicating that there was a fundamental relationship between the deformation mechanisms and activation energies. Models of the yielding process were considered, and it was found that no currently available model was fully applicable to this alloy. It was also demonstrated that the initial deformation mechanism (during yielding) was frequently different from that which would be inferred by examining specimens which were tested to failure.

Milligan, Walter W.↗

Elevated temperature strengthening of a melt spun austenitic steel by TiB2

Mechanical properties of an iron-based alloy containing (by wt pct) 33Ni, 2Al, 6Ti, and 2B (resulting in an alloy containing 10 vol pct TiB2) were evaluated by hardness and tensile testing. The alloy was cast as a ribbon using a dual 'free-jet' variation of Jech et al. (1984) method of chill-block melt-spinning against a copper wheel; to simulate thermal cycles the alloy ribbon would experience during compaction into shapes, various segments of the ribbon were annealed under a vacuum at temperatures ranging from 500 to 1150 C. The results show that maximum strengths at 650 and 760 C were developed in ribbons annealed at 1100 C; in these ribbons an optimal combination of grain coarsening with minimum TiB2 particle growth was observed. However, the elevated-temperature strength of the TiB2-strengthened alloy under optimal annealing conditions was poorer than that of conventional iron-based superalloys strengthened by gamma-prime precipitates.

Michal, G. M.↗

Solidification-Rate Effects In MAR-M-246+Hf Alloy

Under slower solidification, primary-dendrite-arm spacing increases. Report discusses experiments on influence of solidification rates on crystallographic orientation and mechanical properties of superalloy MAR-M-246+Hf. Specimens grown in directional-solidification furnace, visually examined for microstructure, and stretched to failure in tensile-testing machine. Back-reflection Laue x-ray photographs taken to determine growth orientations.

Hamilton, David↗

Study of the mechanical behavior of a 2-D carbon-carbon composite

The out-of-plane fracture of a 2-D carbon-carbon composite was observed and characterized to gain an understanding of the factors influencing the stress distribution in such a laminate. Finite element analyses of a two-ply carbon-carbon composite under in-plane, out-of-plane, and thermal loading were performed. Under in-plane loading all components of stress were strong functions of geometry. Additionally, large thermal stresses were predicted. Out-of-plane tensile tests revealed that failure was interlaminar, and that cracks propagated along the fiber-matrix interface. An elasticity solution was utilized to analyze an orthotropic fiber in an isotropic matrix under uniform thermal load. The analysis reveals that the stress distributions in a transversely orthotropic fiber are radically different than those predicted assuming the fiber to be transversely isotropic.

Avery, W. B.↗

Physical aging in epoxy matrices and composites

Postcured specimens of Thornell 300 carbon-fiber/Fiberite 934 epoxy as well as Fiberite 934 epoxy resin were quenched from above the glass transition temperature and annealed at 140, 110, or 80 C for times up to 100,000 min. No weight gain or loss was observed during annealing at these temperatures, but significant time-dependent variations were observed in density, modulus, hardness, damping, moisture absorption ability, and thermal expansion characteristics. The relations between the excess thermodynamic properties of epoxy glasses and their time-dependent behavior are discussed. The discussion is illustrated by results obtained by differential scanning calorimetry, dynamic mechanical analysis, tensile testing, solid state nuclear magnetic resonance spectroscopy, and small-angle X-ray scattering.

Kong, Eric Siu-Wai↗

The microstructure and tensile properties of extruded melt-spun ribbons of iron-rich B2 FeAl

The microstructure of extruded rods of iron-rich FeAl(B2-structure), as characterized by TEM, SEM, optical microscopy and x-ray diffractometry, consisted of elongated grains with a 111-line fibre texture containing a high dislocation density. Numerous oxide particles were found, mostly in lines which reflected the matrix flow during extrusion. In addition, some large inclusions were present. Tensile testing of annealed, relatively dislocation-free specimens as a function of increasing temperature found increasing ductility up to 900K, above which a ductility drop occurred accompanied by a change in fracture mode, from transgranular cleavage to intergranular fracture. The yield strength, which was independent of temperature up to 800K (at about 500MPa), also decreased rapidly as diffusion became more important. The predominant slip vector changed from 111-line to 100-line around 700K.

Baker, I.↗

Aluminum alloy

At least about 0.1 percent by weight of indium is added as an essential component to an alloy which precipitates a T 1 phase (Al 2 CuLi). This addition enhances the nucleation of the precipitate T 1 phase, producing a microstructure which provides excellent strength as indicated by Rockwell Hardness values and confirmed by standard tensile tests.

Linda B Blackburn↗

Behavior of plasma-sprayed coatings

The microstructural development of plasma sprayed oxide coatings is described with particualr reference to aluminum oxide coatings and thermal barrier coatings of yttria stabilized zirconia (YSZ). The microstructural features of these coatings, observed by optical and electron microscopy, are related to their mechanical behavior. The adhesion of the coatings is also investigated using fracture toughness and tensile tests. It is noted that acoustic emission is valuable in formulating possible fracture mechanisms for YSZ coatings.

Berndt, Christopher C.↗

Use of pure nickel and LiOH for thermal energy storage

The solid to liquid phase transformation of LiOH has been proposed as an ideal candidate thermal energy storage media for a Rankine Cycle powered electrical generation unit envisioned in Space Station based solar dynamic systems. Due to the corrosive nature of molten hydroxides, long term containment of LiOH is of concern. Pure nickel is thought to be a suitably resistant material, and a program has been instituted to measure the effects of prolonged exposure of liquid and gaseous LiOH on the mechanical properties of pure nickel alloys. Results to date indicate that negligible weight and thickness changes occurred in Ni alloys exposed to LiOH for as long as 2500 hr at 775 K, and essentially no difference in 77-900 K tensile properties could be detected between LiOH exposed and vacuum annealed Ni specimens. Although there was little sign of outward damage, microstructural examination revealed that all hydroxide contaminated tensile test specimens had surface connected intergranular cracks along the gage lengths. Two other potential problems, which have strong implications with respect to a LiOH/Ni energy storage system, were also noted during the corrosion experiments. In particular stress corrosion cracking of weld joints in pressurized vessel and permeation of hydrogen through nickel were observed.

Whittenberger, J. D.↗

Graphite/polyimide composites with improved toughness

Studies were performed to determine the toughness characteristics of composites prepared from modified addition-type polyimides, using Celion 6000 graphite fiber as the reinforcement. The polyimides were prepared from aromatic diamines containing flexibilizing ether connecting groups. The composite flexural and short beam shear strengths were determined at room temperature and elevated temperatures. Composite toughness was evaluated using 10 deg off axis tensile tests and double cantilever beam fracture tests at room temperature. The effects of the flexibilized resin structure on composite mechanical properties, toughness characteristics, and thermo-oxidative stability are discussed.

Delvigs, Peter↗

Inelastic deformation and dislocation structure of a nickel alloy - Effects of deformation and thermal histories

Inelastic deformation behavior of the cast Ni-base alloy, B1900 + Hf, was investigated using data from step-temperature tensile tests and thermomechanical cyclic tests in the temperature ranges 538-760 C and 760-982 C. The deformation results were correlated with the dislocation structures of deformed specimens, identified by TEM. It was found that, in the 760-982 C temperature range, there are no thermal history effects in the inelastic deformation behavior of B1900 + Hf. In the 538-760 range, anomalous cyclic hardening and, possibly, thermal history effects were observed in thermomechanically deformed alloy, caused by sessile (010) dislocations in the gamma-prime phase.

Chan, K. S.↗