Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A comparative study on the oxidation of two-dimensional Ti 3 C 2 MXene structures in different environments

The oxidation of two-dimensional Ti 3 C 2 MXene structures has been recognized as a promising method for the formation of hybrid structures of carbon supported nanotitania. Here, we studied the oxidation of Ti 3 C 2 MXene structures using reactive force field (ReaxFF) based molecular dynamics simulations. To investigate the effect of oxidizing agent, we used three different environments including dry air (oxygen molecules), wet air (oxygen and water molecules) and hydrogen peroxide (H 2 O 2 molecules). Oxidation simulations were performed at different temperatures of 1000, 1500, 2000, 2500 and 3000 K. We found that by controlling the temperature, carbon supported titania can be formed by diffusion of Ti atoms to the surface of MXene structures during the oxidation. These results were confirmed by the increase in the average bond orders of C–C and Ti–O and decrease in the average bond orders of Ti–C. Moreover, it was revealed that by increasing the temperature, the oxidation rate increases, and the rate depends on the oxidant according to the following order: H 2 O 2 > wet air > dry air. This was validated by heating the MXene in wet air and dry air followed by examining the products using X-ray diffraction and Raman spectroscopy. To investigate the effect of the presence of the oxidant, the MXene structure was also heated under vacuum, and it was found that in this case the MXene structure was converted to cubic TiC. Furthermore, it was indicated that during the heating process of the MXene structure in a vacuum, the average bond orders for C–C, Ti–C and Ti–O do not change significantly due to the lack of oxidants in the environment, leaving room for only topotactic transformation of atoms during the heating. In conclusion, the formation of the TiC structure by heating the MXene in an inert environment was confirmed experimentally as well.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling optical-cavity locking using reinforcement learning

Abstract This study applies an effective methodology based on Reinforcement Learning to a control system. Using the Pound–Drever–Hall locking scheme, we match the wavelength of a controlled laser to the length of a Fabry-Pérot cavity such that the cavity length is an exact integer multiple of the laser wavelength. Typically, long-term drift of the cavity length and laser wavelength exceeds the dynamic range of this control if only the laser’s piezoelectric transducer is actuated, so the same error signal also controls the temperature of the laser crystal. In this work, we instead implement this feedback control grounded on Q-Learning. Our system learns in real-time, eschewing reliance on historical data, and exhibits adaptability to system variations post-training. This adaptive quality ensures continuous updates to the learning agent. This innovative approach maintains lock for eight days on average.

47 OTHER INSTRUMENTATION↗

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.↗

Development of the Plant Growth Facility for Use in the Shuttle Middeck and Test Units for Ground-Based Experiments

The plant growth facility (PGF), currently under development as a Space Shuttle middeck facility for the support of research on higher plants in microgravity, is presented. The PGF provides controlled fluorescent lighting and the active control of temperature, relative humidity and CO2 concentration. These parameters are designed to be centrally controlled by a dedicated microprocessor. The status of the experiment can be displayed for onboard analysis, and will be automatically archived for post-flight analysis. The facility is designed to operate for 15 days and will provide air filtration to remove ethylene and trace organics with replaceable potassium permanganate filters. Similar ground units will be available for pre-flight experimentation.

Chapman, David K.↗

Behavioral fever in newborn rabbits

New Zealand white rabbit pups aged 12 to 72 hr were divided into three groups and given an intraperitoneal injection of Pseudomonas polysaccharide, a saline vehicle alone, and no treatment, respectively. The animals injected with pyrogen and maintained at an ambient temperature of 32 C for 2 hr did not develop fever. When placed in a thermally graded alleyway, the animals injected with pyrogen selected gradient positions that represented significantly higher temperatures than controls injected with saline. Further stay at selected positions for 5 min caused a considerable increase in the rectal temperature of the pyrogen-injected pups but not that of controls. The results support the hypothesis that newborn rabbits will develop a fever by behavioral means after a single injection of an exogenous pyrogen if the opportunity for thermoregulatory behavior is present. No fever develops if the pups must rely solely on internal thermoregulatory mechanisms. The behavioral system for producing a fever is mature at birth, but an adequate system of internal reflexes does not appear to develop for some days.

Satinoff, E.↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Tuning 2D magnetism in Fe 3+X GeTe 2 films by element doping

Two-dimensional (2D) ferromagnetic materials have been discovered with tunable magnetism and orbital-driven nodal-line features. Controlling the 2D magnetism in exfoliated nanoflakes via electric/magnetic fields enables a boosted Curie temperature (T C ) or phase transitions. One of the challenges, however, is the realization of high T C 2D magnets that are tunable, robust and suitable for large scale fabrication. Here, we report molecular-beam epitaxy growth of wafer-scale Fe 3+X GeTe 2 films with T C above room temperature. By controlling the Fe composition in Fe 3+X GeTe 2 , a continuously modulated T C in a broad range of 185–320 K has been achieved. This widely tunable T C is attributed to the doped interlayer Fe that provides a 40% enhancement around the optimal composition X = 2. We further fabricated magnetic tunneling junction device arrays that exhibit clear tunneling signals. Our results show an effective and reliable approach, i.e. element doping, to producing robust and tunable ferromagnetism beyond room temperature in a large-scale 2D Fe 3+X GeTe 2 fashion.

2D ferromagnetic material↗

Temperature dependence of protein solubility-determination, application to crystallization, and growth kinetics studies

A scintillation method was developed for determinations of the temperature dependence of the solubility, and of nucleation induction times of proteins, in 50-100 mu(l) volumes of solution. Solubility data for lysozyme and horse serum albumin were obtained for various combinations of pH and precipitant concentrations. These data and the nucleation induction information were used for dynamic crystallization control, that is, for the controlled separation of nucleation and growth stages. Individual lysozyme and horse serum albumin crystals were grown in 15-20 mu(l) solution volumes contained in x-ray capillaries. The morphology and kinetics of the growth and dissolution of lysozyme in aqueous solutions with 2.5 percent NaCl and at pH = 4.5 was studied in situ with a depth resolution of 300 A (4 unit cells) by high resolution optical microscopy and digital image processing. The bulk super- or under saturation, sigma, of the solution inside a closed growth cell was controlled by temperature. The growth habit was bound by (110) and (101) faces that grew through layer spreading, although with different growth rate dependencies on supersaturation/temperature. At sigma less than 10 (obtained at higher temperatures) growth was purely kinetic ally controlled, with impurity effects (macrostep formation and kinetic hindrance) becoming significant for sigma less than 2. At sigma greater than 10 (lower temperatures), anisotropies in the interfacial kinetics were more pronounced, with interfacial kinetics and bulk transport becoming equally important to the growth morphology. Growth rates were growth history dependent. The formation of striations (layers of irregularly incorporated solution) was unambiguously correlated with growth temperature variations. Etching exposed dislocations and various high-index faces whose growth morphologies were studied during return to the steady state growth form. Growth steps were observed to originate from two-dimensional nuclei or from outcrops of growth striations, and from dislocations that preferentially formed in growth sector boundaries.

Rosenberger, Franz↗

High-temperature optically activated GaAs power switching for aircraft digital electronic control

Gallium arsenide high-temperature devices were fabricated and assembled into an optically activated pulse-width-modulated power control for a torque motor typical of the kinds used in jet engine actuators. A bipolar heterojunction phototransistor with gallium aluminum arsenide emitter/window, a gallium arsenide junction field-effect power transistor and a gallium arsenide transient protection diode were designed and fabricated. A high-temperature fiber optic/phototransistor coupling scheme was implemented. The devices assembled into the demonstrator were successfully tested at 250 C, proving the feasibility of actuator-located switching of control power using optical signals transmitted by fibers. Assessments of the efficiency and technical merits were made for extension of this high-temperature technology to local conversion of optical power to electrical power and its control at levels useful for driving actuators. Optical power sources included in the comparisons were an infrared light-emitting diode, an injection laser diode, tungsten-halogen lamps and arc lamps. Optical-to-electrical power conversion was limited to photovoltaics located at the actuator. Impedance matching of the photovoltaic array to the load was considered over the full temperature range, -55 C to 260 C. Loss of photovoltaic efficiency at higher temperatures was taken into account. Serious losses in efficiency are: (1) in the optical source and the cooling which they may require in the assumed 125 C ambient, (2) in the decreased conversion efficiency of the gallium arsenide photovoltaic at 260 C, and (3) in impedance matching. Practical systems require improvements in these areas.

Berak, J. M.↗

Controllable oxygen vacancy defect engineering of BiVO 4 porous structures for room temperature NH 3 detection

Controlling structural features of sensing material while judiciously introducing vacancy defect states for revamping the electronic properties of the sample to obtain its superior gas sensing performance, is quite rare. Herein, we report for the first time, the room temperature (RT) ammonia (NH 3 ) detection of peanut-like porous bismuth vanadate (BiVO 4 ) with a stable monoclinic phase. The developed BiVO 4 possess abundant oxygen vacancies and porosity by virtue of calcinations (400–800 ℃). BiVO 4 calcined at 400 ℃ exhibits high selectivity towards NH 3 with a maximum response of 1421 @ 270 ppm at RT, which is 2.5 fold enhanced compared to without calcined BiVO 4 (response of 547 @ 270 ppm NH 3 ). The oxygen defective BiVO 4 appeared highly durable and stable even under high humid conditions (∼60 %). Besides, the porosity of BiVO 4 not only enhances the specific surface area (19.8 m 2 /g) but also results in fast diffusion of NH 3 molecules, leading to a reduction in the decay time (34 s for 90 ppm NH 3 ). The density functional theory (DFT) uncovers that the oxygen vacancy formation in BiVO 4 augments the NH 3 sensing capabilities by enhancing the adsorption energy of NH 3 . This work provides insight into the sensing mechanism of increased response caused by defect engineering and porosity, which will be favourable for fabricating high-performance NH 3 sensors at RT.

DFT analysis↗

Use of Confocal Microscope for Environmental Tensile Mechanical Testing

Mechanical testing in environmental chambers is typically limited to 450°C. Some specialty chambers have been designed but at a high cost. Furthermore, accurate extensometers in environmental chambers are rare and expensive to operate. A unique solution investigated in this manuscript is the mating of a confocal laser scanning microscope with a sealed environmental chamber fitted with loading clevises for mechanical testing. Such a setup allows the researcher to measure strain data at elevated temperatures in controlled environments. Utilizing a laser light source avoids problems with blackbody radiation at elevated temperatures. Setup and accuracy of the microscope are discussed concerning tensile loading. P91 boiler steel was selected for this work because of the long history of the alloy in the fossil energy industry. Optical strain uncertainty was measured between 1.6% and 3.5%. Here, other tensile parameters were satisfactorily measured within the experimental error of larger standard specimens.

36 MATERIALS SCIENCE↗

SCILLA Secondary Aerosol Volume Concentration Airborne Data

This data set contains secondary aerosol volume concentration in cubic micrometers per cubic centimeter (um^3/cm^3). The aerosol was generated in an oxidation flow reactor (OFR) and its volume concentration measured with a scanning mobility particle sizer (SMPS). Both components were designed and built at the University of California Riverside. Ambient particles were removed with a Teflon filter upstream of the OFR and then pure ammonium sulfate particles were added to create a stable aerosol surface area on which low-volatility oxidation products condense. High concentrations of hydroxyl radical (OH) formed inside the OFR accelerate the oxidative chemistry that would typically occur over a period of several days in the atmosphere, resulting in the production of secondary aerosol from precursor gases present in the ambient air. Concentrations of added ozone and water vapor were controlled to produce the desired and approximately constant level of photochemical aging. The reactor temperature was controlled, while the pressure was not, and was always slightly lower than that of the sampled outside air. Sampled air was pulled from above the Naval Postgraduate School’s (NPS) Twin Otter aircraft through a rear-facing, ¼” OD PFA Teflon tube. The sample stream was split between the OFR and several gas analyzers (NOx, CO, O3, and H2O). Though not contained in these files, data from an aerosol mass spectrometer intermittently operated downstream of the OFR are also available.

{"secondary aerosol concentration",aerosol_concent↗

Thermal calibration target

Blackbody source calibrates the response of a medium resolution infrared radiometer used on a meteorological satellite. This approach controls the temperature of a thermal calibrating device over a wide range without the need for controlling a liquid nitrogen input to the device. The availability of liquid nitrogen achieves the required thermal control.

Buller, J. S.↗

Purging means and method for Xenon arc lamps

High pressure Xenon short-arc lamp with two reservoirs which are selectively connectable to the lamp's envelope is described. One reservoir contains an absorbent which will absorb both Xenon and contaminant gases such as CO2 and O2. The absorbent temperature is controlled to evacuate the envelope of both the Xenon and the contaminant gases. The temperature of the absorbent is then raised to desorb only clean Xenon while retaining the contaminant gases, thereby clearing the envelope of the contaminant gases. The second reservoir contains a gas whose specific purpose is, to remove the objectional metal film which deposits gradually on the interior surface of the lamp envelope during normal arc operation. The origin of the film is metal transferred from the cathode of the arc lamp by sputtering or other gas transfer processes.

Miller, C. G.↗

Evaluation of Raytek infrared pyrometer for continuous propellant temperature measurement

The primary purpose of this evaluation was to determine if the Raytek IR pyrometer that was installed in the 600 gallon propellant mixers could be used to provide a continuous, accurate, reliable measurement of the propellant temperature during mixing. The Raytek infrared sensor is not recommended to be used for controlling propellant temperature nor for inspection buy-off. The first part of the evaluation was to determine the accuracy of the sensor in measuring the propellant temperature. The second part was to determine the reliability of the air purge design in preventing contamination of the IR window.

Dykstra, Mark D.↗

Study of Fabry-Perot Etalon Stability and Tuning for Spectroscopic Rayleigh Scattering

The Fabry-Perot interferometer is a commonly employed instrument for resolving the spectrum of molecular Rayleigh scattered light for the purpose of evaluating flow properties such as gas velocity and temperature. Rayleigh scattered light from a focused laser beam can be directly imaged through a solid Fabry-Perot etalon onto a CCD detector to provide the spectral content of the scattered light. The spatial resolution of the measurements is governed by the locations of interference fringes. The location of the fringes can be changed by altering the etalon?s physical characteristics, such as thickness and index of refraction. For a fused silica solid etalon the physical properties can be adjusted by changing the etalon temperature; hence changing the order of the interference pattern and the physical fringe locations. Controlling the temperature of the etalon can provide for a slow time-response spatial scanning method for this type of etalon system. A custom designed liquid crystal Fabry-Perot (LCFP) can provide for a fast time-response method of scanning the etalon system. Voltage applied to the liquid crystal interface sets the etalon?s properties allowing Rayleigh measurements to be acquired at varying spatial locations across the image of the laser beam over a very short time period. A standard fused silica etalon and a tunable LCFP etalon are characterized to select the system that is best suited for Rayleigh scattering measurements in subsonic and supersonic flow regimes. A frequency-stabilized laser is used to investigate the apparent frequency stability and temperature sensitivity of the etalon systems. Frequency stability and temperature sensitivity data of the fused silica and LCFP etalon systems are presented in this paper, along with measurements of the LCFP etalon?s tuning capabilities. Rayleigh scattering velocity measurements with both etalon systems are presented, in an effort to determine which etalon is better suited to provide optical flow measurements of velocity, temperature, and density.

Clem, Michelle M.↗

Liquid-Crystal Thermal-Control Panels

Radiative temperature regulators have no moving parts. Conceptual temperature-regulating system proposed for spacecraft useful in automatic or remotely controlled regulation of solar heating in buildings, provided cost reduced sufficiently. System consists of liquid-crystal panels made to absorb or reflect sunlight.

Dehaye, R. F.↗