Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Subsurface Temperature, Moisture, Thermal Conductivity and Heat Flux, Area A, B, C, and D, Utqiagvik (Barrow), Alaska, Ongoing from 2012

Subsurface soil monitoring stations are located across each of the four NGEE Arctic, Utqiagvik (Barrow), Alaska, intensive study Areas: (A) low-centered polygons with well-defined troughs, (B) high-centered polygons, (C) flat-centered or transitional polygons, and (D) inundated low-centered polygons with no troughs. Two data products are being generated - both with high temporal (hourly) and spatial resolution (within polygon and with depth): (1) soil profile temperature measurements and (2) active layer and permafrost temperature and moisture measurements from instrumented soil pits. This data package currently contains seventy-nine .csv files, one .xlsx (with complimentary .csv file), and one .pdf. Data from September 2012 through August 2022 are available as annual files. Additional data will be added annually after quality checks have been completed. These data are being collected to better understand the thermal dynamics of the active layer and permafrost. Together this information serves as calibration and evaluation data for fine-scale simulations of polygons. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal analysis of Bridgman-Stockbarger growth

A thermal analysis of a cylindrical HgCdTe sample in a Bridgman-Stockbarger crystal growth configuration was conducted with emphasis on the thermal profile, interface shape and position, and the thermal gradients at the liquid-solid interface. Alloys of HgTe and CdTe with compositions approximating 20 percent CdTe, 80 percent HgTe were used. This composition results in a bandgap suited for the detection of 10.6 micron CO2 radiation. The sensitivity of the sample thermal characteristics to important growth parameters, such as thermal diffusivities, thermal conductivities, furnace temperature profile, ampoule dimensions, and growth velocity was assessed. Numerical techniques and associated computational models necessary to analyze the heat transfer process within the sample and the Bridgman-Stockbarger boundary conditions were developed. This thermal analysis mode was programmed in FORTRAN V, and is currently operational on the MSFC Univac 1100 system.

Knopf, F. W.↗

The spectrum of Titan in the far-infrared and microwave regions

The pressure-induced absorptions of gaseous nitrogen (N2) and methane (CH4) are computed on the basis of the collisional lineshape theory of Birnbaum and Cohen (1976). Laboratory data at 300 and 124 K for N2 and at 296 and 195 K for CH4 are used to determine the collisional time constants and their temperature dependence. The spectrum of Titan from the microwave to the far-infrared region (0.1-600/cm) is then modeled using these opacities and a temperature profile of Titan's atmosphere derived from the Voyager 1 radio occultation experiment. The model atmosphere is composed of N2 and CH4, their relative proportions being determined by the vapor pressure law of CH4. A model with gaseous opacity alone is ruled out by the far-infrared observations. An additional opacity, thought to be associated with a methane cloud, is confirmed. The effective temperature of Titan is estimated at 83.2 plus or minus 1.4 K.

Courtin, R.↗

Numerical Modeling of Physical Vapor Transport in Contactless Crystal Growth Geometry

Growth from the vapor under conditions of limited contact with the walls of the growth ampoule is beneficial for the quality of the growing crystal due to reduced stress and contamination which may be caused by interactions with the growth container. The technique may be of a particular interest for studies on crystal growth under microgravity conditions: elimination of some factors affecting the crystal quality may make interpretation of space-conducted processes more conclusive and meaningful. For that reason, and as a part of our continuing studies on 'contactless' growth technique, we have developed a computational model of crystal growth process in such system. The theoretical model was built, and simulations were performed using the commercial computational fluid dynamics code, (CFD) ACE. The code uses an implicit finite volume formulation with a gray discrete ordinate method radiation model which accounts for the diffuse absorption and reflection of radiation throughout the furnace. The three-dimensional model computes the heat transfer through the crystal, quartz, and gas both inside and outside the ampoule, and mass transport from the source to the crystal and the sink. The heat transport mechanisms by conduction, natural convection, and radiation, and mass transport by diffusion and convection are modeled simultaneously and include the heat of the phase transition at the solid-vapor interfaces. As the thermal boundary condition, temperature profile along the walls of the furnace is used. For different thermal profiles and furnace and ampoule dimensions, the crystal growth rate and development of the crystal-vapor and source-vapor interfaces (change of the interface shape and location with time) are obtained. Super/under-saturation in the ampoule is determined and critical factors determining the 'contactless' growth conditions are identified and discussed. The relative importance of the ampoule dimensions and geometry, the furnace dimensions and its temperature, and the properties of the grown material are analyzed. The results of the simulations are compared with related experimental results on growth of CdTe, CdZnTe, ZnTe, PbTe, and PbSnTe crystals by this technique.

Palosz, W.↗

Lubricant impacts on piston deposit formation in the Enterprise marine diesel research engine

The impact of lubricant formulation on piston deposits was studied using the Enterprise, a reduced-scale, single-cylinder, two-stroke crosshead marine diesel research engine. The Enterprise engine was specially designed for marine diesel lubricant research, with a custom reduced-scale cylinder lubricant injection system and extensive instrumentation of thermal boundary conditions on both the liner and piston. Lubricant conditions typical of full-scale marine diesel engines are obtained by matching mean piston speed, liner temperature profile, and combustion metrics to realistic values.Piston deposit thicknesses were measured after a set period of operation, with a focus on lubricant-based deposits on the lands and ring grooves, using both optical and contact-based measurement techniques. Engine operation for each lubricant was conducted according to a standardized protocol, with precise control of engine speed and load, cylinder lubricant injection rate, coolant temperatures, and system oil temperature; the liner and piston temperatures are continuously monitored during operation. After operation with each lubricant was completed, the engine was disassembled, and the piston and ring deposits were characterized. The piston was then thoroughly cleaned, and the lubricant system flushed, between each lubricant formulation being evaluated. The impacts on piston deposits of the lubricants being evaluated can thus be accurately quantified and are described herein.

Kaul, Brian↗

A comparison between Nimbus 5 THIR and ITPR temperatures and derived winds with rawinsonde data obtained in the AVE II experiment

During the second Atmospheric Variability Experiment (AVE II), atmospheric temperature profiles were computed from Nimbus 5 data, which comprised ITPR, NEMS, and SCR measurements. Rawinsonde data were obtained from NWS stations in the AVE II network and processed for each pressure contact; the soundings closest in space and time were interpolated to the Nimbus 5 sounding points for comparison purposes. Cross sections of thermal and geostrophic winds were computed from satellite-derived cross sections of temperature along the Nimbus orbital track.

Arnold, J. E.↗

Lidar observation of ozone over Tsukuba (36 deg N, 140 deg E)

An ozone lidar system was installed at the National Institute for Environmental Studies (NIES) in Tsukuba, Japan in March 1988 and has been measuring vertical profiles of ozone (15 - 45 km) since September 1988. The lidar system consists of a XeCl (308 nm) excimer laser, its deuterium Raman shifter (339 nm), a XeF excimer laser (351 nm), a 2 m telescope, a receiving system and a data processing system. The precision of the derived ozone concentration is about 10 percent of an altitude of 40 km for a 4 hr observation. Temperature profiles (30 - 80 km) are also obtained from the Rayleigh scattering signals at 351 nm. Approximate 50 ozone measurements are carried out in a year and variations of vertical profiles of ozone such as seasonal variations and shorter-term variations are observed. Systematic errors due to aerosols had been negligible until the arrival of the stratospheric aerosols injected by the eruption of Mt. Pinatubo. Effects of the volcanic aerosols on ozone measurements depend on the differences between wavelengths used as the on- and off-resonance.

Nakane, H.↗

Measurement of heat flow through cast slabs of calcium sulfate dihydrate

Slabs of cast calcium sulfate dihydrate have been used for decades as a heat transfer barrier in commercial and residential construction and are assessed in accordance with the parameters defined by ASTM C1396. The study described herein hypothesizes that minor impurities have significant effects on the high–temperature performance of these casts. Five thermocouples are cast into a 20–mm–thick slab at approximately 4–mm intervals are measured between ambient and approximately 1000°C in a furnace. Thermal diffusivity and inertia are estimated from this temperature profile. This study compares natural, flue gas desulfurized (FGD) and reagent grade hemihydrates that have been converted into the dihydrate form with distilled water; the common additives kaolin and borax are used to modify the cast. The thermocouple data allow an effective thermal diffusivity (α') and an effective thermal inertia (I') to be calculated. Furthermore, the hemihydrate source and kaolin content are found to affect the high–temperature performance; the FGD source increases the thermal inertia, and kaolin inhibits the formation of other borate compounds through intercalation.

36 MATERIALS SCIENCE↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

Mass-radius relationships in icy satellites

Using published laboratory data for H2O ice, a modeling technique was developed by which the bulk density, density and temperature profile, rotational moment of inertia, central pressure, and location of the rock-ice interface can all be obtained as a function of the radius, the heliocentric distance, and the silicate composition. Models of the interiors of Callisto, Ganymede, Europa, Rhea, and Titan are given, consistent with present mass and radius data. The radius and mass of spheres of ice under self-gravitation for two different temperature classes are given (103 and 77 deg K). Measurements of mass, radius and I/MR2 by spacecraft can be interpreted by this model to yield substantial information about the internal structure and the ice/rock ratio of the icy satellites of Jupiter and Saturn.

Lupo, M. J.↗

Thermal Modeling and Analysis of a Cryogenic Tank Design Exposed to Extreme Heating Profiles

A cryogenic test article, the Generic Research Cryogenic Tank, was designed to qualitatively simulate the thermal response of transatmospheric vehicle fuel tanks exposed to the environment of hypersonic flight. One-dimensional and two-dimensional finite-difference thermal models were developed to simulate the thermal response and assist in the design of the Generic Research Cryogenic Tank. The one-dimensional thermal analysis determined the required insulation thickness to meet the thermal design criteria and located the purge jacket to eliminate the liquefaction of air. The two-dimensional thermal analysis predicted the temperature gradients developed within the pressure-vessel wall, estimated the cryogen boiloff, and showed the effects the ullage condition has on pressure-vessel temperatures. The degree of ullage mixing, location of the applied high-temperature profile, and the purge gas influence on insulation thermal conductivity had significant effects on the thermal behavior of the Generic Research Cryogenic Tank. In addition to analysis results, a description of the Generic Research Cryogenic Tank and the role it will play in future thermal structures and transatmospheric vehicle research at the NASA Dryden Flight Research Facility is presented.

Stephens, Craig A.↗

Nonequilibrium Crystal Growth During Laser Annealing of Silicon

The Systematic studies of dopant (Group III, IV, or V) incorporation into silicon as a result of pulsed-laser annealing are reviewed. At low concentrations, dopant profiles measured after laser annealing can be compared to model calculations for redistribution by liquid-phase diffusion in order to determine the interfacial distribution coefficient K('). At high concentrations there is a limit (C sub s) to dopant incorporation into substitutional lattice sites. The mechanisms which limit dopant incorporation are discussed as well as the dependence of K(') and (max) on crystal orientation. Finally, measurements of interface temperatures, temperature profiles, and thermal gradients during rapid solidification are summarized.

White, C. W.↗

Satellite sensing capabilities for surface temperature and meteorological parameters over the ocean

Remote meteorological measurements over the oceans have been used extensively for weather forecasting, ship safety, and global-scale studies of climate and sea conditions. A review is conducted regarding the satellite-sensing capabilities for sea-surface temperature and tropospheric marine meteorological mesurements. The tropospheric measurements are concerned with vertical temperature profiles, integrated water vapor and liquid water, rain, aerosols and surface winds. Attention is also given to several environmental-monitoring applications where satellite sensed synoptic data might be combined with ground and airborne chemical measurements to provide improved assessments of regional and global ennvironmental quality and climatology. Special emphasis is given to current satellite measurement accuracies (errors) and to programs involving U.S. technology. Aspects of sea-surface temperature are treated in detail in connection with extensive studies concentrated in this area.

Darnell, W. L.↗

Rover/NERVA-derived near-term nuclear propulsion

FY-92 accomplishments centered on conceptual design and analyses for 25, 50, and 75 K engines with emphasis on the 50 K engine. During the first period of performance, flow and energy balances were prepared for each of these configurations and thrust-to-weight values were estimated. A review of fuel technology and key data from the Rover/NERVA program established a baseline for proven reactor performance and areas of enhancement to meet near-term goals. Studies were performed of the criticality and temperature profiles for probable fuel and moderator loadings for the three engine sizes, with a more detailed analysis of the 50 K size. During the second period of performance, analyses of the 50 K engine continued. A chamber/nozzle contour was selected and heat transfer and fatigue analyses were performed for likely construction materials. Reactor analyses were performed to determine component radiation heating rates, reactor radiation fields, water immersion poisoning requirements, temperature limits for restartability, and a tie-tube thermal analysis. Finally, a brief assessment of key enabling technologies was made, with a view toward identifying development issues and identification of the critical path toward achieving engine qualification within 10 years.

Source record↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Nonlocal effects on thermal transport in hydrodynamic simulations of unmagnetized MagLIF-relevant gaspipes on NIF

We present simulations of heat flow relevant to gaspipe experiments on the National Ignition Facility to investigate kinetic effects on transport phenomena. D 2 and neopentane (C 5 H 12 ) filled targets are used to study the laser preheat stage of a MagLIF scheme where an axial magnetic field is sometimes applied to the target. Simulations were done with the radiation-MHD code HYDRA with a collision-dominated fluid model and the SNB nonlocal electron thermal conduction model. Using the SNB model to evolve the electron temperature increased the heat front propagation of neopentane gas targets compared to a local model by limiting radial heat flow. This increases electron temperature near the axis, which decreases laser absorption. We find that the effect of heat flow models on temperature profiles and laser propagation is modest. Beyond the SNB model, we utilize HYDRA to initialize plasma conditions for the Vlasov–Fokker–Planck K2 code. We run K2 until a quasi-steady state is reached and examine the impact of kinetic effects on heat transport. Although axial heat flow is well predicted by fluid models, the fluid model consistently overpredicts radial heat flow up to 150% in regions with the largest temperature gradient of D 2 filled gaspipes. On the other hand, the SNB nonlocal electron conduction model is found to be adequate for capturing kinetic heat flow in gaspipes.

Lau, Ryan Y. [Univ. of Colorado, Boulder, CO (Unit↗

Effect of heat acclimation on sitting orthostatic tolerance in the heat after 48 and 96 hour bed rest in men

The purpose of this pilot study was to investigate sitting orthostatic tolerance and determine potentially adverse signs and symptoms that would incapacitate subjects in a hot environment (Gemini reentry cabin temperature profile) after 48 hr and 96 hr of horizontal bed rest (BR), which simulated microgravity deconditioning. Six college men (23-29 yr) were allocated into two groups: heat acclimated (three subjects: No. 1- control, No. 2- 48 hr BR, and No. 3- 96 hr BR) and nonheat acclimated (three subjects: No. 4- control, No. 5- 48 hr BR, and No. 6- 96 hr BR). After BR they sat in an ambient temperature of 57 C (135 F) for 30 min which then was decreased to 49 C (120 F) for up to 480 min. Tolerance time in the heat with seated orthostatic stress was 480 min (subject No. 1) and 180 min (subject No. 4) in the two ambulatory men, but was reduced to 22-150 min in the four bed-rested men irrespective of their heat acclimation status. Although heat acclimation appeared to enhance tolerance and attenuate accompanying physiological responses, as well as ameliorate the frequency and intensity of adverse signs and symptoms at termination of exposure, tolerance was reduced in the bed-rest deconditioned subjects regardless of their acclimation level. Thus, these few collective findings do not indicate an unequivocal positive effect of acute heat acclimation on sitting orthostatic tolerance in acute bed-rest deconditioned subjects.

Greenleaf, J. E.↗