Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

SU-E-I-46: Sample-Size Dependence of Model Observers for Estimating Low-Contrast Detection Performance From CT Images

Purpose: Recently, task-based assessment of diagnostic CT systems has attracted much attention. Detection task performance can be estimated using human observers, or mathematical observer models. While most models are well established, considerable bias can be introduced when performance is estimated from a limited number of image samples. Thus, the purpose of this work was to assess the effect of sample size on bias and uncertainty of two channelized Hotelling observers and a template-matching observer. Methods: The image data used for this study consisted of 100 signal-present and 100 signal-absent regions-of-interest, which were extracted from CT slices. The experimental conditions included two signal sizes and five different x-ray beam current settings (mAs). Human observer performance for these images was determined in 2-alternative forced choice experiments. These data were provided by the Mayo clinic in Rochester, MN. Detection performance was estimated from three observer models, including channelized Hotelling observers (CHO) with Gabor or Laguerre-Gauss (LG) channels, and a template-matching observer (TM). Different sample sizes were generated by randomly selecting a subset of image pairs, (N=20,40,60,80). Observer performance was quantified as proportion of correct responses (PC). Bias was quantified as the relative difference of PC for 20 and 80 image pairs. Results: For n=100, all observer models predicted human performance across mAs and signal sizes. Bias was 23% for CHO (Gabor), 7% for CHO (LG), and 3% for TM. The relative standard deviation, σ(PC)/PC at N=20 was highest for the TM observer (11%) and lowest for the CHO (Gabor) observer (5%). Conclusion: In order to make image quality assessment feasible in the clinical practice, a statistically efficient observer model, that can predict performance from few samples, is needed. Our results identified two observer models that may be suited for this task.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

The Spectrum of Thermally Stimulated Surface Plasmon Polaritons of a Linear Sample

An analytical model of the spectrum of thermally stimulated surface plasmon polaritons (TSSPPs) coming to the edge of a linear conducting sample has been developed. It has been found that the spectrum of such TSSPPs obeys neither the Wien law nor the Stefan–Boltzmann law for thermal radiation. The maximum of this spectrum is shifted to the low-frequency region with respect to the spectrum of the absolutely black body, and the magnitude of the shift is proportional to the sample length. The plasmon nature of the intensity increment of thermal radiation from the edge of a plane face of a duralumin sample has been verified experimentally. It has been shown that the intensity and spectrum of this increment can be controlled both by the sample temperature and by the extension of the face.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The I-V characteristics of asymmetrically necked samples of high-resistivity silicon

The results of investigation of the I-V characteristics are presented for asymmetrically necked n-Si samples. It is established that the asymmetry of the I-V characteristic for the samples under investigation at the room and liquid-nitrogen temperatures in high electric fields is caused by the space-charge formation. At T = 78 K in the warm-electron region, the asymmetry of the I-V characteristic is caused by nonlocal relation between the electron mobility and the nonuniform electric-field intensity. It is found that the sample resistance at liquid-nitrogen temperature insignificantly increases after applying high electric-field pulses. The effect under observation is attributed to a decrease in the electron concentration in the necked section of the sample due to the redistribution of hot electrons between bulk and surface.

36 MATERIALS SCIENCE↗

Silicon with an increased content of monoatomic sulfur centers: Sample fabrication and optical spectroscopy

The effect of the high-temperature heating (at 1340 Degree-Sign C) of sulfur-doped silicon samples and their subsequent quenching is studied. The results of such a treatment are analyzed on the basis of Hall-effect data obtained in the temperature range T = 78-500 K. It is shown that the heating duration strongly affects the relative concentrations of different types of deep sulfur-related centers. At comparatively short heating durations of t = 2-10 min, the concentration of quasi-molecular S{sub 2} centers and S{sub X} complexes substantially decreases, whereas the density of monoatomic S{sub 1} centers grows. At the same time, the heating of a sample is accompanied by a monotonic decrease in the total concentration of electrically active sulfur over time. The results obtained make it possible to give recommendations concerning the optimal conditions for the fabrication of samples with a high concentration of S{sub 1} centers. The absorption spectra of the samples show that the method is promising for the observation of a number of quantum-optical effects involving deep S{sub 1} donors in silicon.

36 MATERIALS SCIENCE↗

Experimental Determination of the Radial Displacement Field in the Neck of Samples after a Tensile Test

This Letter presents the results of a study of the radial displacement fields arising upon stretching of cylindrical samples before their disintegration. The object of study was sv-07Kh16N6 stainless steel wire containing filiform defects oriented along the sample axis. Using X-ray tomography of the sample necks, the coordinates of the defect points in the sample are determined and the displacement field is recovered from them. The resulting dependence is represented by an approximate formula.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient sampling of constrained high-dimensional theoretical spaces with machine learning

Abstract Models of physics beyond the Standard Model often contain a large number of parameters. These form a high-dimensional space that is computationally intractable to fully explore. Experimental results project onto a subspace of parameters that are consistent with those observations, but mapping these constraints to the underlying parameters is also typically intractable. Instead, physicists often resort to scanning small subsets of the full parameter space and testing for experimental consistency. We propose an alternative approach that uses generative models to significantly improve the computational efficiency of sampling high-dimensional parameter spaces. To demonstrate this, we sample the constrained and phenomenological Minimal Supersymmetric Standard Models subject to the requirement that the sampled points are consistent with the measured Higgs boson mass. Our method achieves orders of magnitude improvements in sampling efficiency compared to a brute force search.

Hollingsworth, Jacob↗

Screening of Viral Pathogens from Pediatric Ileal Tissue Samples after Vaccination

In 2010, researchers reported that the two US-licensed rotavirus vaccines contained DNA or DNA fragments from porcine circovirus (PCV). Although PCV, a common virus among pigs, is not thought to cause illness in humans, these findings raised several safety concerns. In this study, we sought to determine whether viruses, including PCV, could be detected in ileal tissue samples of children vaccinated with one of the two rotavirus vaccines. A broad spectrum, novel DNA detection technology, the Lawrence Livermore Microbial Detection Array (LLMDA), was utilized, and confirmation of viral pathogens using the polymerase chain reaction (PCR) was conducted. The LLMDA technology was recently used to identify PCV from one rotavirus vaccine. Ileal tissue samples were analyzed from 21 subjects, aged 15–62 months. PCV was not detected in any ileal tissue samples by the LLMDA or PCR. LLMDA identified a human rotavirus A from one of the vaccinated subjects, which is likely due to a recent infection from a wild type rotavirus. LLMDA also identified human parechovirus, a common gastroenteritis viral infection, from two subjects. Additionally, LLMDA detected common gastrointestinal bacterial organisms from the Enterobacteriaceae , Bacteroidaceae , and Streptococcaceae families from several subjects. This study provides a survey of viral and bacterial pathogens from pediatric ileal samples, and may shed light on future studies to identify pathogen associations with pediatric vaccinations.

59 BASIC BIOLOGICAL SCIENCES↗

Elemental and topographical imaging of microscopic variations in deposition on NSTX-U and DIII-D samples

Tokamak plasma facing components have surface roughness that can cause microscopic spatial variations in erosion and deposition and hence influence material migration, erosion lifetime, dust and tritium accumulation, and plasma contamination. However high spatial resolution measurements of deposition on the scale of the surface roughness have been lacking to date. We will present elemental images of graphite samples from NSTX-U and DIII-D DiMES experiments performed with a Scanning Auger Microprobe at sub-micron resolution that show strong microscopic variations in deposition and correlate this with 3D topographical maps of surface irregularities. The NSTX-U samples were boronized and exposed to deuterium plasmas and the DiMES samples had localized Al and W films and were exposed to dedicated helium plasmas. Topographical maps of the samples were performed with a 3D confocal optical microscope and compared to the elemental deposition pattern. The results revealed localized deposition concentrated in areas shadowed from the ion flux, incident in a direction calculated (for the DiMES case) by taking account of the magnetic pre-sheath.

Surface analysis↗

Does size matter? Separations on guard columns for fast sample analysis applied to bioenergy research

Increasing sample throughput is needed when large numbers of samples have to be processed. In chromatography, one strategy is to reduce column length for decreased analysis time. Therefore, the feasibility of analyzing samples simply on a guard column was explored using refractive index and ultraviolet detection. Results from the guard columns were compared to the analyses using the standard 300 mm Aminex HPX-87H column which is widely applied to the analysis of samples from many biotechnology- and bioenergy-related experiments such as biomass conversions or fermentations.

Biotechnology & Applied Microbiology↗

Standard experimental paradigm designs and data exclusion practices in cognitive psychology can inadvertently introduce systematic “shadow” biases in participant samples

Abstract Standard cognitive psychology research practices can introduce inadvertent sampling biases that reduce the reliability and generalizability of the findings. Researchers commonly acknowledge and understand that any given study sample is not perfectly generalizable, especially when implementing typical experimental constraints (e.g., limiting recruitment to specific age ranges or to individuals with normal color vision). However, less obvious systematic sampling constraints, referred to here as “shadow” biases, can be unintentionally introduced and can easily go unnoticed. For example, many standard cognitive psychology study designs involve lengthy and tedious experiments with simple, repetitive stimuli. Such testing environments may 1) be aversive to some would-be participants (e.g., those high in certain neurodivergent symptoms) who may self-select not to enroll in such studies, or 2) contribute to participant attrition, both of which reduce the sample’s representativeness. Likewise, standard performance-based data exclusion efforts (e.g., minimum accuracy or response time) or attention checks can systematically remove data from participants from subsets of the population (e.g., those low in conscientiousness). This commentary focuses on the theoretical and practical issues behind these non-obvious and often unacknowledged “shadow” biases, offers a simple illustration with real data as a proof of concept of how applying attention checks can systematically skew latent/hidden variables in the included population, and then discusses the broader implications with suggestions for how to manage and reduce, or at a minimum acknowledge, the problem.

Siritzky, Emma M.↗

Neutron-Irradiated Samples as Test Materials for MPEX

Plasma Material Interaction (PMI) is a major concern in fusion reactor design and analysis. The Material-Plasma Exposure eXperiment (MPEX) will explore PMI under fusion reactor plasma conditions. Samples with accumulated displacements per atom (DPA) damage produced by fast neutron irradiations in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) will be studied in the MPEX facility. This paper presents assessments of the calculated induced radioactivity and resulting radiation dose rates of a variety of potential fusion reactor plasma-facing materials (such as tungsten). The scientific code packages MCNP and SCALE were used to simulate irradiation of the samples in HFIR including the generation and depletion of nuclides in the material and the subsequent composition, activity levels, gamma radiation fields, and resultant dose rates as a function of cooling time. A challenge of the MPEX project is to minimize the radioactive inventory in the preparation of the samples and the sample dose rates for inclusion in the MPEX facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elemental analysis of slurry samples with laser induced breakdown spectroscopy

Direct analysis of wet slurry samples with laser induced breakdown spectroscopy (LIBS) is challenging due to problems of sedimentation, splashing, and surface turbulence. Also, water can quench the laser plasma and suppress the LIBS signal, resulting in poor sensitivity. The effect of water on LIBS spectra from slurries was investigated. As the water content decreased, the LIBS signal was enhanced and the standard deviation was reduced. To improve LIBS slurry analysis, dried slurry samples prepared by applying slurry on PVC coated slides were evaluated. Univariate and multivariate calibration was performed on the LIBS spectra of the dried slurry samples for elemental analysis of Mg, Si, and Fe. Calibration results show that the dried slurry samples give a good correlation between spectral intensity and elemental concentration.

54 ENVIRONMENTAL SCIENCES↗

Sensitive detection of metals in water using laser-induced breakdown spectroscopy on wood sample substrates

Water contaminated with toxic heavy metals can be a great risk to humans. Laser-induced breakdown spectroscopy (LIBS) is a promising candidate to monitor heavy metals in aqueous solutions on site, but the sensitivity is still a major problem. To perform sensitive analysis of analyte metals in aqueous solutions with LIBS, a thin wood sample substrate was used as a liquid absorber to transform the liquid sample analysis to a solid sample analysis. We focus on investigating the performance of this technique using different laser wavelengths (266, 532, and 1064 nm) with a low pulse energy (<5 mJ) and a different number of shots (from 10 to 1000). We demonstrate that a limit of detection of 30 ppb can be achieved using low energy pulses with a 1000 shot accumulation. This technique provides a potentially simple approach for a portable micro LIBS system to monitor water samples.

74 ATOMIC AND MOLECULAR PHYSICS↗

A novel analysis method for paired-sample microbial ecology experiments

Many microbial ecology experiments use sequencing data to measure a community s response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samples and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method s validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Furthermore, our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of bottle effects .

59 BASIC BIOLOGICAL SCIENCES↗

Real-Time Pathogen Detection in the Era of Whole-Genome Sequencing and Big Data: Comparison of k-mer and Site-Based Methods for Inferring the Genetic Distances among Tens of Thousands of Salmonella Samples

The adoption of whole-genome sequencing within the public health realm for molecular characterization of bacterial pathogens has been followed by an increased emphasis on real-time detection of emerging outbreaks (e.g., food-borne Salmonellosis). In turn, large databases of whole-genome sequence data are being populated. These databases currently contain tens of thousands of samples and are expected to grow to hundreds of thousands within a few years. For these databases to be of optimal use one must be able to quickly interrogate them to accurately determine the genetic distances among a set of samples. Being able to do so is challenging due to both biological (evolutionary diverse samples) and computational (petabytes of sequence data) issues. We evaluated seven measures of genetic distance, which were estimated from either k-mer profiles (Jaccard, Euclidean, Manhattan, Mash Jaccard, and Mash distances) or nucleotide sites (NUCmer and an extended multi-locus sequence typing (MLST) scheme). Finally, when analyzing empirical data (wholegenome sequence data from 18,997 Salmonella isolates) there are features (e.g., genomic, assembly, and contamination) that cause distances inferred from k-mer profiles, which treat absent data as informative, to fail to accurately capture the distance between samples when compared to distances inferred from differences in nucleotide sites. Thus, site-based distances, like NUCmer and extended MLST, are superior in performance, but accessing the computing resources necessary to perform them may be challenging when analyzing large databases.

59 BASIC BIOLOGICAL SCIENCES↗

Untargeted, tandem mass spectrometry (LC/MS-MS) metaproteomes from soil samples in control and warming plots in Blodgett Forest, CA (2014-2021)

The pathways of carbon transport and loss through and from soils—soil organic matter (SOM) depolymerization to dissolved organic carbon and mineralization to carbon dioxide (CO2)—are fundamentally driven by microbial activity, which is strongly regulated by environmental conditions. As part of Lawrence Berkeley National Laboratory (LBNL) Terrestrial Ecosystem Science (TES) Belowground Biogeochemistry Science Focus Area (SFA), we have established a novel whole-soil long-term warming experiment at the University of California (UC) Blodgett Forest Research Station (Sierra Nevada) in 2014, where we study the role of biogeochemical, microbial and geochemical process interactions in SOM decomposition and stabilization. This package contains soil metaproteomics data in the context of site specific metagenomes from soil depth profiles in three paired control and warming plots from a temperate mixed forest in Northern California. Each paired plot had been subjected to experimental warming since June 2014 to simulate a predicted climate change scenario for northern California. These metaproteomes were collected in 2018 after 4.5 years of warming from five depth intervals (0-10 cm, 10-30 cm, 30-45 cm, 45-60 cm, 60-80 cm). For protein identification, the collected spectra were searched following a target-decoy search strategy against a database of metagenome predicted proteins (covering 96 samples from 2014 to 2021) representing the complete sequence diversity at the site. Data was searched with mass spectrometry database search tool (MS-GF+) using Pacific Northwest National Laboratory (PNNL)'s Data Management System (DMS) Processing pipeline. The metagenomes are published as part of another data package. Raw metaproteomic data and the data products from MS-GF+ are deposited in the Mass Spectrometry Interactive Virtual Environment (MassIVE) database under accession no. MSV000097826. Here we present a dataset that includes spectral counts for the detected proteins across samples (EMSL50964_BrodieAllMAGs_Globals_SC.txt), the sequences of the detected proteins, and sample metadata file that contains site information for the soil metaproteome samples.

Belowground Biogeochemistry Science Focus Area↗

A Provably Accurate Randomized Sampling Algorithm for Logistic Regression

In statistics and machine learning, logistic regression is a widely-used supervised learning technique primarily employed for binary classification tasks. When the number of observations greatly exceeds the number of predictor variables, we present a simple, randomized sampling-based algorithm for logistic regression problem that guarantees high-quality approximations to both the estimated probabilities and the overall discrepancy of the model. Our analysis builds upon two simple structural conditions that boil down to randomized matrix multiplication, a fundamental and well-understood primitive of randomized numerical linear algebra. We analyze the properties of estimated probabilities of logistic regression when leverage scores are used to sample observations, and prove that accurate approximations can be achieved with a sample whose size is much smaller than the total number of observations. To further validate our theoretical findings, we conduct comprehensive empirical evaluations. Overall, our work sheds light on the potential of using randomized sampling approaches to efficiently approximate the estimated probabilities in logistic regression, offering a practical and computationally efficient solution for large-scale datasets.

Chowdhury, Agniva↗