Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Comparison of Gafchromic EBT2 and EBT3 for patient-specific quality assurance: Cranial stereotactic radiosurgery using volumetric modulated arc therapy with multiple noncoplanar arcs

Purpose: Patient-specific quality assurance in volumetric modulated arc therapy (VMAT) brain stereotactic radiosurgery raises specific issues on dosimetric procedures, mainly represented by the small radiation fields associated with the lack of lateral electronic equilibrium, the need of small detectors and the high dose delivered (up to 30 Gy). Gafchromic{sup TM} EBT2 and EBT3 films may be considered the dosimeter of choice, and the authors here provide some additional data about uniformity correction for this new generation of radiochromic films.Methods: A new analysis method using blue channel for marker dye correction was proposed for uniformity correction both for EBT2 and EBT3 films. Symmetry, flatness, and field-width of a reference field were analyzed to provide an evaluation in a high-spatial resolution of the film uniformity for EBT3. Absolute doses were compared with thermoluminescent dosimeters (TLD) as baseline. VMAT plans with multiple noncoplanar arcs were generated with a treatment planning system on a selected pool of eleven patients with cranial lesions and then recalculated on a water-equivalent plastic phantom by Monte Carlo algorithm for patient-specific QA. 2D quantitative dose comparison parameters were calculated, for the computed and measured dose distributions, and tested for statistically significant differences.Results: Sensitometric curves showed a different behavior above dose of 5 Gy for EBT2 and EBT3 films; with the use of inhouse marker-dye correction method, the authors obtained values of 2.5% for flatness, 1.5% of symmetry, and a field width of 4.8 cm for a 5 × 5 cm{sup 2} reference field. Compared with TLD and selecting a 5% dose tolerance, the percentage of points with ICRU index below 1 was 100% for EBT2 and 83% for EBT3. Patients analysis revealed statistically significant differences (p < 0.05) between EBT2 and EBT3 in the percentage of points with gamma values <1 (p= 0.009 and p= 0.016); the percent difference as well as the mean difference between calculated and measured isodoses (20% and 80%) were found not to be significant (p= 0.074, p= 0.185, and p= 0.57).Conclusions: Excellent performances in terms of dose homogeneity were obtained using a new blue channel method for marker-dye correction on both EBT2 and EBT3 Gafchromic{sup TM} films. In comparison with TLD, the passing rates for the EBT2 film were higher than for EBT3; a good agreement with estimated data by Monte Carlo algorithm was found for both films, with some statistically significant differences again in favor of EBT2. These results suggest that the use of Gafchromic{sup TM} EBT2 and EBT3 films is appropriate for dose verification measurements in VMAT stereotactic radiosurgery; taking into account the uncertainty associated with Gafchromic film dosimetry, the use of adequate action levels is strongly advised, in particular, for EBT3.

61 RADIATION PROTECTION AND DOSIMETRY↗

Forward modeling of an atmospheric scenario: path characterization in terms of scattering intensity

The knowledge of possible impairments due to atmospheric propagation is of importance in the framework of future 5G mobile networks that use spectrum resource up to the W band. Here, the authors propose the scalar Scatter Indicator (SI), defined as the difference between the simulated TB at 72 GHz and the TB value at the same frequency estimated from a combination of TBs values at 23.8 and 31.4 GHz under assumed scatter-free condition. On the basis of radiosonde profiles observed in Milan, Linate (Italy) in 2005, clear-sky scenarios are used as reference to define a scatter-free TB’s database. A second database of simulated TBs including scattering effects is generated with ARTS to build the SI. Numerical results show that the SI assumes significant positive values with increasing drop effective radius and total liquid water LWP and it can be used to identify the scattering due to hydrometeor

54 ENVIRONMENTAL SCIENCES↗

Ash reduction strategies in corn stover facilitated by anatomical and size fractionation

There is growing interest internationally to produce fuels from renewable biomass resources. Inorganic components of biomass feedstocks, referred to collectively as ash, damage equipment and decrease yields in thermal conversion processes, and decrease feedstock value for biochemical conversion processes. Decreasing the ash content of feedstocks improves conversion efficiency and lowers process costs. Because physiological ash is unevenly distributed in the plant, mechanical processes can be used to separate fractions of the plant based on ash content. This study focuses on the ash separation that can be achieved by separating corn stover by particle size and anatomical fraction. Baled corn stover was hand-separated into anatomical fractions, ground to <19.1 mm, and size separated using six sieves ranging from 9.5 to 0.150 mm. Size fractions were analyzed for total ash content and ash composition. Particle size distributions observed for the anatomical fractions varied considerably. Cob particles were primarily 2.0 mm or greater, while most of the sheath and husk particles were 2.0 mm and smaller. Particles of leaves greater than 0.6 mm contained the greatest amount of total ash, ranging from approximately 8 to 13% dry weight of the total original material, while the fractions with particles smaller than 0.6 mm contained less than 2% of the total ash of the original material. As a result, based on the overall ash content and the elemental ash, specific anatomical and size fractions can be separated to optimize the feedstocks being delivered to biofuels conversion processes and minimize the need for more expensive ash reduction treatments.

09 BIOMASS FUELS↗

Uranium Isotopic Ratio Measurements of U3O8 Reference Materials by Atom Probe Tomography

We report results of measurements of isotopic ratios obtained with atom probe tomography on U3O8 reference materials certified for their isotopic abundances of uranium. The results show good agreement with the certified values. High backgrounds due to tails from adjacent peaks complicate the measurement of the integrated peak areas as well as the fact that only oxides of uranium appear in the spectrum, the most intense of which is doubly charged. In addition, lack of knowledge of other instrumental parameters, such as the dead time, may bias the results. Isotopic ratio measurements can be performed at the nanometer-scale with the expectation of sensible results. The abundance sensitivity and mass resolving power of the mass spectrometer are not sufficient to compete with magnetic-sector instruments but are not far from measurements made by ToF-SIMS of other isotopic systems. The agreement of the major isotope ratios is more than sufficient to distinguish most anthropogenic compositions from natural.

Atom Probe Tomography↗

Failure behavior of SiC/SiC composite tubes under strain rates similar to the pellet-cladding mechanical interaction phase of reactivity-initiated accidents

The mechanical response of a nuclear-grade silicon carbide fiber-reinforced silicon carbide matrix (SiC/SiC) composite was investigated under mechanical loading conditions mimicking the pellet-cladding mechanical interaction (PCMI) phase of a reactivity-initiated accident (RIA). In a RIA, cladding deformation and failure can be induced by the rapid thermal expansion of the nuclear fuel. A pulse-controlled modified-burst test was used to investigate RIA-like PCMI scenarios on SiC/SiC composite samples at pulse widths from 12 to 100 ms.The strain-driven nature of the cladding sample deformation was due to the rapid internal pressurization and subsequent expansion of a secondary tube. A digital-image correlation technique was used to measure strains from the speckle-painted outer surface of the tubes. The failure strains of samples tested at slower rates, such as RIA event durations of 52 and 100 ms, showed good agreement with the literature-reported values for similar composites tested at slow strain rates. Additionally, the failure strain showed good agreement with reference expansion-due-to-compression tests at slow strain rate. However, a decrease in the failure strain was determined for the fast-rate (12 ms) tests. This indicated that the failure strain of these composites might be influenced by the strain rate during RIA-like events. In conclusion, the failure strains observed in the tests corresponded to local energy depositions of approximately 50 cal/g UO 2 from hot zero power, with an initial condition of pellet–cladding gap closure prior to the event. In-pile transient testing of these concepts that would result in hoop strain due to PCMI in the range of 0.5–1.0% is recommended.

36 MATERIALS SCIENCE↗

PythonFOAM: In-situ data analyses with OpenFOAM and Python

Here, we outline the development of a general-purpose Python-based data analysis tool for OpenFOAM. Our implementation relies on the construction of OpenFOAM applications that have bindings to data analysis libraries in Python. Double precision data in OpenFOAM is cast to a NumPy array using the NumPy C-API and Python modules may then be used for arbitrary data analysis and manipulation on flow-field information. We highlight how the proposed wrapper may be used for an in-situ online singular value decomposition (SVD) implemented in Python and accessed from the OpenFOAM solver PimpleFOAM. Here, 'in-situ' refers to a programming paradigm that allows for a concurrent computation of the data analysis on the same computational resources utilized for the partial differential equation solver. In addition, to demonstrate parallel deployments, we deploy a distributed SVD, which collects snapshot data across the ranks of a distributed simulation to compute the global left singular vectors. Crucially, both OpenFOAM and Python share the same message passing interface (MPI) communicator for this deployment which allows Python objects and functions to exchange NumPy arrays across ranks. Subsequently, we provide scaling assessments of this distributed SVD on multiple nodes of Intel Broadwell and KNL architectures for canonical test cases such as the large eddy simulations of a backward facing step and a channel flow at friction Reynolds number of 395. Finally, we demonstrate the deployment of a deep neural network for compressing the flow-field information using an autoencoder to demonstrate an ability to use state-of-the-art machine learning tools in the Python ecosystem.

97 MATHEMATICS AND COMPUTING↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Calculation of electron Dose Point Kernel in water with GEANT4 for medical application

The rapid insertion of new technologies in medical physics in the last years, especially in nuclear medicine, has been followed by a great development of faster Monte Carlo algorithms. GEANT4 is a Monte Carlo toolkit that contains the tools to simulate the problems of particle transport through matter. In this work, GEANT4 was used to calculate the dose-point-kernel (DPK) for monoenergetic electrons in water, which is an important reference medium for nuclear medicine. The three different physical models of electromagnetic interactions provided by GEANT4 - Low Energy, Penelope and Standard - were employed. To verify the adequacy of these models, the results were compared with references from the literature. For all energies and physical models, the agreement between calculated DPKs and reported values is satisfactory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coupled-cluster based approach for core-level states in condensed phase: Theory and application to different protonated forms of aqueous glycine

A theoretical approach for calculating core-level states in condensed phase is presented. The approach is based on equation-of-motion coupled-cluster theory (EOMCC) and effective fragment potential (EFP) method. By introducing an approximate treatment of double excitations in the EOM-CCSD (EOM-CC with single and double substitutions) ansatz, we address poor convergence issues that are encountered for the core-level states and significantly reduce computational costs. While the approximations introduce relatively large errors in the absolute values of transition energies, the errors are systematic. Consequently, chemical shifts, changes in ionization energies relative to reference systems, are reproduced reasonably well. By using different protonation forms of solvated glycine as a benchmark system, we show that our protocol is capable of reproducing the experimental chemical shifts with a quantitative accuracy. The results demonstrate that chemical shifts are very sensitive to the solvent interactions and that explicit treatment of solvent, such as EFP, is essential for achieving quantitative accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of density fluctuations during the search for an I-mode regime on the DIII-D tokamak

The I-mode regime, routinely observed on the Alcator C-Mod tokamak, is characterized by an edge energy transport barrier without an accompanying particle barrier and with broadband instabilities, known as weakly coherent modes (WCM), believed to regulate particle transport at the edge. Recent experiments on the DIII-D tokamak exhibit I-mode characteristics in various physical quantities. These DIII-D plasmas evolve over long periods, lasting several energy confinement times, during which the edge electron temperature slowly evolves towards an H-mode-like profile, while maintaining a typical L-mode edge density profile. During these periods, referred to as I-mode phases, the radial electric field at the edge also gradually reaches values typically observed in H-mode. Density fluctuations measured with the phase contrast imaging diagnostic during I-mode phases exhibit three features typically observed in H-mode on DIII-D, although they develop progressively with time and without a sharp transition: the intensity of the fluctuations is reduced; the frequency spectrum is broadened and becomes non-monotonic; two dimensional space-time spectra appear to approach those in H-mode, showing phase velocities of density fluctuations at the edge increasing to about 10 km s -1 . However, in DIII-D there is no clear evidence of the WCM. Preliminary linear gyro-kinetic simulations are performed in the pedestal region with the GS2 code and its recently upgraded model collision operator that conserves particles, energy and momentum. The increased bootstrap current and flow shear generated by the temperature pedestal are shown to decrease growth rates, thus possibly generating a feedback mechanism that progressively stabilizes fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of non-diffuse characteristics of the seismic noise field in southern California based on correlations of neighbouring frequencies

Non-diffuse characteristics of the ambient seismic noise wavefield recorded at 154 broad-band stations in southern California are analysed by computing the correlation matrix of power spectral values at neighbouring frequencies. The similarities of the derived correlation matrices are compared by choosing a different reference station at a time. The data recorded by the different stations are classified into five groups using a hierarchical clustering algorithm based on the similarity of the correlation matrices. Stations belonging to different groups are clustered spatially in the Los Angeles basin, mountains and regions farther from the coast. The deviations from diffuse wavefield in the correlation matrices of representative stations from the five groups are inverted for dominant cross-frequency components. These are used to derive power spectral ratios of non-diffuse noise and fully diffuse noise. The similarity maps for different reference stations and the inverted cross-frequency components provide information on properties of the noise sources and propagation/scattering characteristics in the different regions.

58 GEOSCIENCES↗

SU-E-T-494: Influence of Proton Track-Cell Nucleus Incidence Angle On Relative Biological Effectiveness

Purpose: To explain a Monte Carlo (MC) simulation artifact whereby differences in relative biological effectiveness (RBE) in the induction of initial double strand breaks are observed as a function of the proton track incidence angles in a geometric cell nucleus model. Secondly, to offer an alternative isotropic irradiation procedure to mitigate this effect. Methods: MC tracks of 1 MeV protons were generated in an event-by-event mode. They were overlaid on a cylindrical model of a cell nucleus containing 6×109 nucleotide base pairs. The tracks incidence angle θ with respect to the cell nucleus’s axis was varied in 10 degrees intervals, each time generating one hundred fractions of ∼2 Gy. Strand breaks were scored in the modeled DNA sugar-phosphate groups and further sub-classified into single or double strand breaks (ssbs or dsbs). For each angle, an RBE for the induction of initial dsbs with reference to Co-60 was calculated. Results: Our results show significant angular dependencies of RBE, with maximum values for incidence angles parallel to the nucleus central axis. Further examination shows that the higher cross-sections for the creation of dsbs is due to the preferential alignment of tracks with geometrical sub-parts of the cell nucleus model, especially the nucleosomes containing the sugar-phosphate groups. To alleviate the impact of this simulation artifact, an average RBE was calculated with a procedure based on a weighted sampling of the angular data. Conclusion: This work demonstrates a possible numerical artifact in estimated RBE if the influence of the particle incidence angle is not correctly taken into account. A correction procedure is presented to better conform the simulations to real-life experimental conditions. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from the CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

60 APPLIED LIFE SCIENCES↗

SU-F-T-593: Technical Treatment Accuracy in a Clinic of Fractionated Stereotactic Radiosurgery

Purpose: The purpose of this study is to estimate technical treatment accuracy in fractionated stereotactic radiosurgery (fSRS) using extend system (ES) of Gamma Knife (GK). Methods: The fSRS with GK relies on a patient specific re-locatable immobilization system. The reference treatment position is estimated using a digital probe and a repositioning check tool (RCT). The “calibration values” of RCT apertures were compared with measured values on RCT-QA tool to evaluate the standard error (SE) associated with RCT measurements. A treatment plan with single “4 mm collimator shot” was created to deliver a radiation dose of 5 Gy at the predefined plane of a newly designed in-house head-neck phantom. The plan was investigated using radiochromic EBT3 films. The stereotactic CT imaging of a designed mini CT phantom and distortion study of MR imaging, were combined to calculate imaging SE. The focal precision check for GK machine tolerance was performed using a central diode test tool. Results: Twenty observations of RCT and digital probe, shown the SE of +/−0.0186mm and +/−0.0002mm respectively. A mean positional shift of 0.2752mm (σ=0.0696mm) was observed for twenty similar treatment settings of head-neck phantom. The difference between radiological and predefined exposure point was 0.4650mm and 0.4270mm; for two independent experiments. The imaging studies showed a combined SE of +/− 0.1055mm. Twenty frequent runs of a diode test tool showed the tolerance SE of +/−0.0096mm. If, the measurements are considered to be at 95% of confidence level, an expanded uncertainty was evaluated as +/− 0.2371mm with our system. The positional shift, when combined with an expanded uncertainty, a trivial variation of 0.07mm (max) was observed in comparing resultant radiological precision through film investigations. Conclusion: The study proposes an expression of “technical treatment accuracy” within “known uncertainties” is rational in the estimation of routine fSRS quality. The research work is supported by the research section of “All India Institute of Medical Sciences” - New Delhi, India under project no A-247.

60 APPLIED LIFE SCIENCES↗

SEFOR Core I-E

This repository contains the VTB model developed for the Southwest Experimental Fast Oxide Reactor (SEFOR) core configuration I-E using the NEAMS tools. The MOOSE Reactor Module was employed to set up the geometry mesh, MC2-3 was applied to generate multigroup cross sections at various temperatures, and Griffin was used to calculate the k-eff values of Core I-E across these temperature conditions. To validate the deterministic results from Griffin, reference solutions were obtained with the Monte Carlo code Shift. The reactivity feedback was then derived and compared against SEFOR experimental data from isothermal tests in order to assess the performance of Griffin. Reproducing these results requires licensed access to several code systems, including Shift, Griffin, and MC2-3. Instructions for obtaining and accessing these codes can be found at the following locations: https://www.ornl.gov/scale/releases for SCALE/Shift, https://mooseframework.inl.gov/ncrc/applications/ncrc_root_griffin.html for Griffin, and https://www.anl.gov/nse/mc23 for MC2-3.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of two-dimensional zero reference codes with cross-entropy method

We present a cross-entropy (CE)-based method for the design of optimum two-dimensional (2D) zero reference codes (ZRCs) in order to generate a zero reference signal for a grating measurement system and achieve absolute position, a coordinate origin, or a machine home position. In the absence of diffraction effects, the 2D ZRC design problem is known as the autocorrelation approximation. Based on the properties of the autocorrelation function, the design of the 2D ZRC is first formulated as a particular combination optimization problem. The CE method is then applied to search for an optimal 2D ZRC and thus obtain the desirable zero reference signal. Computer simulation results indicate that there are 15.38% and 14.29% reductions in the second maxima value for the 16x16 grating system with n1=64 and the 100x100 grating system with n1=300, respectively, where n1 is the number of transparent pixels, compared with those of the conventional genetic algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global Ocean Surface Water Partial Pressure of CO 2 Database: Measurements Performed During 1968-2007 (Version 2007)

More than 4.1 million measurements of surface water partial pressure of CO 2 obtained over the global oceans during 1968-2007 are listed in the Lamont-Doherty Earth Observatory (LDEO) database, which includes open ocean and coastal water measurements. The data assembled include only those measured by equilibrator-CO 2 analyzer systems and have been quality-controlled based on the stability of the system performance, the reliability of calibrations for CO 2 analysis, and the internal consistency of data. To allow re-examination of the data in the future, a number of measured parameters relevant to pCO 2 measurements are listed. The overall uncertainty for the pCO 2 values listed is estimated to be ± 2.5 µatm on the average. For simplicity and for ease of reference, this version is referred to as 2007, meaning that data collected through 31 December 2007 has been included. It is our intention to update this database annually. There are 37 new cruise/ship files in this update. In addition, some editing has been performed on existing files so this should be considered a V2007 file. Also we have added a column reporting the partial pressure of CO 2 in seawater in units of Pascals. The data presented in this database include the analyses of partial pressure of CO 2 (pCO 2 ), sea surface temperature (SST), sea surface salinity (SSS), pressure of the equilibration, and barometric pressure in the outside air from the ship’s observation system. The global pCO 2 data set is available free of charge as a numeric data package (NDP) from the Carbon Dioxide Information Analysis Center (CDIAC). The NDP consists of the oceanographic data files and this printed documentation, which describes the procedures and methods used to obtain the data.

54 ENVIRONMENTAL SCIENCES↗

Precision voltage regulator

Balanced positive and negative voltage output circuit, in which error voltage for control is developed from difference in absolute value of positive and negative voltages referenced to a common point, regulates voltage for use with inertial reference unit. Fast-acting, temperature-compensated, high-gain operational amplifier circuits maintain common point.

Hand, P. J.↗

Experiment S005: Synoptic terrain photography

Several tentative conclusions can be derived from the results of the synoptic terrain photography experiment, with particular reference to the results from the Gemini mission. The photographs are additional confirmation of the feasibility and value of orbital photographs for geology, geography, and oceanography. The photographs have proven to be of value in the study of the tectonic problems. Although vertical or near-vertical photography is superior to oblique photography, photographs from the Gemini 12 mission have proven that low oblique photographs, and even high oblique photographs, may be of value for certain situations. The oblique views of the Makran Range were useful substitutes for vertical photographs. Equivalent aerial coverage by vertical photographs would have necessitated a camera altitude of several hundred miles. The oblique views of the Sierra Madre Oriental have been used in the search for structures that are approximately normal to the horizon and are enhanced by the foreshortening because of the photograph.

Lowman, P. D., Jr.↗