TID, SEE and radiation induced failures in advanced flash memories

We report on TID and SEE tests of multi-level and higher density flash memories. Stand-by currents and functionality tests were used to characterize the response of radiation-induced failures. The radiation-induced failures can be categorized as followings: SEU read errors during irradiation, stuck-bit read errors verified post-irradiation, write errors, erase failures, multiple upsets, and single-event latch up.

Scheick, Leif Z.↗

Expedited Model Building Method for Rocket Nozzle Side Loading

Statistical analysis of test data is currently the preferred method of creating models for uncharacterized side loading in rocket nozzles. However, statistical analysis requires multiple data sets to be reliable; getting these sets requires building and testing multiple rocket motors, which is not feasible given the incredible time and cost required to do so. By using a combination of geometry, simplified finite element analysis (FEA) analogs, and algebra we can create a limited predictive model from only one test data set. Once created, the model requires only the input from one strain gauge located at each yaw and pitch attachment bracket for the actuation system. This process is not computationally intensive, therefore saving an abundance of time and budget over using full 3D FEA models to develop a similar predictive model. To develop the model, conversion factors between the strain at the gauge locations and corresponding actuator load is derived from the data. These conversion factors are used to create a “conversion ellipse” that bounds the constitutive properties of the nozzle as one lumped factor. Using a 2D cross-sectional analog of the nozzle exit plane, we create a function that allows us to determine the azimuthal location of the unexpected load based on the ratio between yaw and pitch strain readings. Combining this with the “conversion ellipse” yields a function that given the strain reading outputs an induced actuator load, regardless of the azimuthal location of the unexpected load. As previously mentioned, this predictive model is limited in its application as there is inaccuracy introduced by the use of data by only one test as well as simplifying assumptions. This approach makes a useful tool to quickly determine whether uncharacterized actuator loading events can damage actuation systems or induce loading that exceeds design limits.

Seetha A Kolli↗

Unsteady Pressure-Sensitive-Paint Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

Unsteady Pressure-Sensitive Paint (UPSP) Shot Noise Reduction

In the study of unsteady Pressure-Sensitive Paint (uPSP) image data sets, pixel intensity values collected by Phantom cameras from multiple perspectives are used to calculate the surface pressure of an experimental model. This paper focuses on mitigation of shot noise which is introduced into the image data set by the cameras. Shot noise impacts the quality of data collected, increasing the system error in its pressure value calculations. This paper characterises statistical methods to reduce shot noise within experimental data by taking an average or weighted average across an area of pixels of their respective counts. Each combined-pixel has a higher total effective intensity value and therefore exhibits reduced noise throughout its time history. This is demonstrated by calculating the standard deviations of the combined pixel values through time, which decrease as the combined pixel area increases. Finally, these methods are compared across experimental wind tunnel conditions to examine their effectiveness at different Mach numbers. Ultimately, the results are used to recommend a blur filter type and size which will be applied to the raw image data prior to processing, as well as a minimum camera resolution for future experiments. Downstream of the filter application, the software to convert the 2D image data sets into surface pressure readings on a 3D grid use a ratio of decimation that assigns multiple pixels to each 3D grid node. This decimation ratio will also be aligned with the size of the blur filter, resulting in a more manageable data set size and compromised spatial resolution. Combined with the effect of the blur filter, the resulting pixel intensity readings will exhibit significantly reduced shot noise, reducing the magnitude of uncertainty and error in the final calculated pressure. For future tests, the camera spatial resolution must be sufficient to capture small flow and model features even after the recommended blur filter is applied. The image data set is taken from a uPSP experiment of the Space Launch System Block 1 cargo vehicle model in September 2019.

Lucy Tang↗

Method Development for In-situ Detection of Latent Herpesvirus DNA from Saliva using Nanopore Sequencing

Research toward latent herpesvirus reactivation has been intensively addressed through Space Shuttle and International Space Station (ISS) investigations. This work has provided the understanding that persistent reactivation of herpesviruses from asymptomatic crew can be detected through viral shedding in saliva, urine, and blood. Occasionally, viral reactivation from the latency stage can pose a threat to crew health (clinical manifestation) before, during, and after flight missions. Furthermore, previous work detailing correlations with immunity indicate that monitoring viral reactivation could be implemented to assess potential immune dysfunction. While in-flight monitoring is desirable, there is no well-established procedure or method for real-time evaluations, and research to date has relied on postflight, ground-based analysis. The development of portable molecular technologies like the miniPCR™ (miniPCR Bio) thermal cycler and the MinION™ sequencer (Oxford Nanopore Technologies) have confirmed that real-time monitoring is possible in extreme and low resource environments. These devices, combined with simple sample preparation methods, have been used to demonstrate bacterial identification onboard the ISS, as well as rapid viral detection in remote locations on Earth. The work here builds upon previous molecular advancements onboard the ISS toward the development and validation of a spaceflight-compatible method for viral detection from crew samples. Several herpesviruses can be detected in saliva, which provides a non-invasive means to collect samples for monitoring. While the basis for this method lies in previous spaceflight investigations, key points for method optimization include DNA extraction from saliva, viral primer selection, and bioinformatic processes for data analysis. To increase viral yield, numerous DNA extraction methods have been evaluated and will be discussed in detail. For initial development and testing, varicella-zoster virus (VZV) is being targeted though open reading frame 51 and 63 (ORF51, ORF63), as the replication origin-binding protein is highly expressed during latency. Optimization of the thermal cycling parameters has resulted in the ability to test the entire process. The full method has been tested with both viral VZV DNA standards and saliva spiked with varying concentrations of VZV. Viral sequence data were mapped to the reference sequence using minimap2. Prior to mapping, DNA sequencing reads were filtered for length and quality, barcodes were removed, and alignment identity calculated. Following further assessments, statistics were compared across multiple sequencing experiments and are being used to determine the success of the protocols. Forward work will include the incorporation of herpes simplex virus 1 (HSV-1) and Epstein-Barr virus (EBV) primers as well as the validation of results to the terrestrial qPCR standard assay. Upon full validation of the developed method, saliva will be collected from 20 healthy subjects and spiked with viral DNA. These samples will be split and assayed with the MinION and standard qPCR assay.

Hang N Nguyen↗

New Features of the NEQAIR Radiation Code

The longest-lived code for predicting shock layer radiation, NEQAIR, is now in its 5th decade of service. Substantial changes to the code have been made over the previous decade, the most recent report of which was at the 5th Workshop on Radiation in High Temperature Gases in 2014, for the version referred to as NEQAIR14. This paper will review some of the improvements made to the NEQAIR code since then, which is now at v15.2. Some of these features are discussed briefly below. NEQAIR15 and subsequent versions have enabled parallel evaluation of multiple lines of sight. This is accomplished by utilizing the HDF5 file format and placing multiple lines into a single file, LOS.h5, which is used for both input and output. This approach enables straightforward parallel execution both over the number of lines of sight and the number of points per line. For large problems, runtime reduces linearly with the number of nodes deployed since each line is processed independently by a subset of MPI ranks. Three applications of the multi-line solver are discussed. The first has to do with performing loosely coupled radiation-flowfield solutions. In this case the computed absorption and emission coefficients are used to evaluate the total energy absorbed or emitted at each point, allowing evaluation of the volumetric source term in the flowfield. The second computation is for obtaining heat flux from nonuniform flows, which require integration over spherical co-ordinates. These are of particular interest for evaluating radiation on the vehicle backshell. This 3D option improves the angular integration scheme and allows adaptive line selection that together reduce the number of lines required by about an order of magnitude. The final application is for remote observation, which is essentially the 3D integration problem over a small solid angle. For all three of these computations, data can be stored in the HDF5 file which allows a NEQAIR run to be restarted when it times out, or to add atmospheric absorption or instrument scan functions. An additional level of parallelism is enabled in NEQAIR15.2 using GPU routines. The GPU parallelism has realized up to 8x speed-up when running on a single core but diminishes as CPU parallelism is increased. For running multi-line simulations, it may be easier to reserve a large number of CPU nodes than to obtain the number of GPU nodes required for similar performance. A GUI, known as NEQTPY, allows for reading and creating input files, running NEQAIR, and displaying results. A significant feature of NEQTPY is the ability to perform spectral fits to data. The fits can operate on a single line spectrum (radiance vs. wavelength) or a 3D input file with multiple columns of data. Other new features include improved constants, additional species, more detailed non-Boltzmann modelling, advanced user controls, the ability to read and calculate spectra from HITRAN datafiles, photodissociation and photoionization cross-sections. A “fast” automatic grid option may reduce the size and time of spectral calculations while still maintaining good accuracy for total heat flux.

Brett A Cruden↗

Firmware Architecture of the ARMADAS Bolting Robot

The Automated Reconfigurable Mission Adaptive Digital Assembly Systems (ARMADAS) project, under development at NASA Ames Research Center, has demonstrated on-ground autonomous robotic assembly of extensive digital structures, and it is now moving forward towards in-space demonstration. The ARMADAS system comprises of the operation software, the operation user interface (opsUI), and a swarm of robots. The robotic system consists of a multitude of collaborative agents specifically designed to transport, place and bolt the building blocks, called voxels (volumetric pixels). This paper focuses on the bolting robot, referred to as Mobile Metamaterial Internal Co-Integrator (MMIC-I). MMIC-I is a battery-powered crawling robot. It navigates the structure through extension, contraction and gripping. Two distinct controller boards operate the robot's two symmetric modules, referred to as module A and B. Board A is the master board: it coordinates motion planning and motion primitives execution, hosts the WiFi client, performs periodic self-assessment and system idle check and triggers faults if anomalies are detected. Board B periodically sends a heartbeat to board A, through a wired communication channel that uses the Serial protocol. Additionally, board A's WiFi client receives heartbeat packet requests or motion/bolting commands from a dedicated server board, and acknowledges reception sending back a response heartbeat packet containing information about the overall robot status, e. g. electrical current and voltage values, target and actual angles, operating mode, fault status. Whenever a motion command is sent, the motion planning section of the firmware determines the current robot configuration, using Inertial Measurement Unit readings and the motors Pulse Width Modulation values. Afterwards, it calculates the list of primitives needed to reach the target state, and controls their execution in the proper order. MMIC-I can receive and execute motion and bolting commands only when it is in operational mode. MMIC-I has three operating modes: standby, operational and safed. Standby mode is automatically entered upon startup. While in standby mode, all motors are powered off, and the only accepted commands are the ones relative to a change of mode and heartbeat packet request. Fault detection causes the robot to automatically enter safed or standby mode. Whenever the detected fault occurs within a motion and requires immediate intervention, e. g. an over-current situation, the robot enters safed mode. Safed mode powers off all motors except for the locomotion module, thus preventing the robot from collapsing. Conversely, when the detected fault doesn't require immediate intervention (low battery warning, for instance), the robot enters standby mode after completing the ongoing motion. This paper provides a detailed discussion of MMIC-I's firmware architecture. It accurately describes the implementation approach for each module: sensor data reading, motor control and actuation, WiFi server-client communication, intra-boards Serial communication, operating modes and autonomous fault detection, motion planning, coordination and execution, etc. Moreover, in support of the software description, this paper includes a thorough characterization of MMIC-I's hardware and avionics.

In-space assembly↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Status on the Recovery of Voyager Plasma Electron Observations at Jupiter

We give status report on the recovery of Voyager 1 and 2 plasma electron observations during their Jupiter flybys. The plan is to complete this analysis including new results never published before. The original summary data tapes and later datafiles were evidently permanently lost along with our past analysis results of the plasma electron observations except for that shown in previous publications. These summary data tapes included the plasma ion and electron raw datafiles, status words needed to convert data numbers to currents, SEDR data with trajectory and attitude information and magnetic field measurements. In addition to recovering the plasma electron plasma observations (electron intensities and fluid parameters of the thermal and suprathermal electron populations, respectively), the SEDR trajectory information during the out bound passes were lost but fortunately in the past the SEDR files were converted to Spice Kernals, so this unexpected problem was solved. In addition, we had to rewrite our read routines it looked like the previous read routines so the rest of the Fortran code could be used; the Fortran- code had to be modified to work with the latest compilers and computer platforms. We will report on the- status of our work- originally funded under the Planetary Data Archiving, Restoration, and Tools (PDART)program but now being funded by the Internal Scientist Funding Model (ISFM) Exosphere Ionosphere Magnetospheres Modeling (EIMM)program at NASA Goddard Space Flight Center.

E C Sittler Jr.↗

The Influence of Viability, Independence, and Self-Governance on Trust and Public Acceptance of Uncrewed Air Vehicle Operations

Trust is expected to be a critical construct that drives successful use of advanced air mobility (AAM) technologies. As yet, though, the role of trust in human-autonomy interaction is underexplored. Kaber (2018) argues that autonomy requires the highest level of three independent dimensions -- viability, independence, and self-governance. The present study examined whether trust varies across the three dimensions of autonomy under varying levels of risk. Participants in the high-risk group read a series of vignettes on a drone that delivers medical supplies over a city where the current study was conducted. Participants in the low-risk group read a series of vignettes on a drone that delivers fast food over a fictitious city. Each vignette described a drone that is either autonomous (i.e., possesses all dimensions) or automated (i.e., one of the dimensions is compromised). Results imply that the three dimensions of autonomy do not equally influence human-technology trust and behavior.

Advanced Air Mobility↗

Computational Icing Analysis on NASA’s SIDRM Geometry to Investigate Collection Efficiency

Computational icing analysis results were compared to experimental icing tunnel data including aerothermal (e.g. dry air) and supercooled water droplet rime-ice conditions from tests conducted in early 2022 at the NASA Icing Research Tunnel (IRT). The Simulated Intercompressor Duct Research Model (SIDRM) test article was used in this study, and its geometry represents the inter-compressor duct region of a turbofan engine. The test article’s purpose is to study the physics of supercooled water icing and ice crystal icing. This study compared three different icing codes: FENSAP-ICE (Eulerian approach), LEWICE3D (Lagrangian approach), and GlennICE (Lagrangian approach). All three icing codes were conducted on SIDRM’s complex body flow-field and compared to different experimental supercooled water rime runs. The test article instrumentation (pressure taps, thermocouples, etc.) and 3D laser scans of final ice shapes were used to compare against the different icing code simulations. The overall objectives are to understand how the icing codes handle capturing collection efficiency on the complex test article’s unheated surfaces. In the aerothermal cases, pressure tap readings matched the CFD results, but dry air CFD underpredicted thermocouple readings. Collection efficiency results from all three icing codes matched well together on the main body leading edge, main body slope, and the strut leading edges. All three icing codes underpredicted the final ice shape using a single-shot constant ice density approach, with more difficulty coming from the strut leading edge ice shape due to the swept wing like flow field. NASA’s overall goal for this effort is to develop computational icing tools to assist in the design and certification of engines for flight in icing conditions.

Supercooled icing, SIDRM, aerodynamics, computatio↗

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

An Optically Stimulated Luminescence Uranium Enrichment Monitor

The Pacific Northwest National Laboratory (PNNL) has pioneered the use of Optically Stimulated Luminescence (OSL) technology for use in personnel dosimetry and high dose radiation processing dosimetry. PNNL has developed and patented an alumina-based OSL dosimeter that is being used by the majority of medical X-ray and imaging technicians worldwide. PNNL has conceived of using OSL technology to passively measure the level of UF6 enrichment by attaching the prototype OSL monitor to pipes containing UF6 gas within an enrichment facility. The prototype OSL UF6 monitor utilizes a two-element approach with the first element open and unfiltered to measure both the low energy and high energy gammas from the UF6, while the second element utilizes a 3-mm thick tungsten filter to eliminate the low energy gammas and pass only the high energy gammas from the UF6. By placing a control monitor in the room away from the UF6 pipes and other ionizing radiation sources, the control readings can be subtracted from the UF6 pipe monitor measurements. The ratio of the shielded to the unshielded net measurements provides a means to estimate the level of uranium enrichment. PNNL has replaced the commercially available MicroStar alumina-based dosimeter elements with a composite of polyethylene plastic, high-Z glass powder, and BaFBr:Eu OSL phosphor powder at various concentrations. The high-Z glass was added in an attempt to raise the average “Z” of the composite dosimeter and increase the response. Additionally, since BaFBr:Eu OSL phosphor is optimally excited and emits light at different wavelengths compared to alumina, the commercially available MicroStar reader was modified for reading BaFBr:Eu in a parallel effort to increase reader sensitivity. PNNL will present the design and performance of our novel OSL uranium enrichment monitor based on a combination of laboratory and UF6 test loop measurements. PNNL will also report on the optimization effort to achieve the highest possible performance from both the OSL enrichment monitor and the new custom OSL reader modified for this application. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monte Carlo Assessments of Absorbed Doses to the Hands of Radiopharmaceutical Workers Due to Photon Emitters

This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters that are used to show compliance with applicable regulations may overestimate or underestimate radiation doses to the skin depending on the nature of the particular procedure and the radionuclide being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations of realistic configurations typical for workers handling radiopharmaceuticals were performedfor a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from dosimeter readings when dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High speed preamplifier circuit, detection electronics, and radiation detection systems therefrom

A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.