Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS

The inner tracker of the ATLAS detector is scheduled to be replaced by a completely new silicon-based inner tracker (ITk) for the Phase-II of the CERN LHC (HL-LHC). The silicon strip detector covers the volume 40 < R < 100 cm in the radial and | z | < 300 cm in the longitudinal directions. The silicon sensors for the detector will be fabricated using the n + -on-p 6-inch wafer technology, for a total of 22,000 wafers. Here, intensive studies were carried out on the final prototype sensors ATLAS17LS fabricated by Hamamatsu Photonics (HPK). The charge collection properties were examined using penetrating 90 Sr β -rays and the ALIBAVA fast readout system for the miniature sensors of 1 cm × 1 cm in area. The samples were irradiated by protons in the 27 MeV Birmingham Cyclotron, the 70 MeV CYRIC at Tohoku University, and the 24 GeV CERN-PS, and by neutrons at Ljubljana TRIGA reactor for fluence values up to 2 × 10 15 n eq /cm 2 . The change in the charge collection with fluence was found to be similar to the previous prototype ATLAS12, and acceptable for the ITk. Sensors with two active thicknesses, 300 μ m (standard) and 240 μ m (thin), were compared and the difference in the charge collection was observed to be small for bias voltages up to 500 V. Some samples were also irradiated with gamma radiation up to 2 MGy, and the full depletion voltage was found to decrease with the dose. This was caused by the Compton electrons due to the 60 Co gamma radiation. To summarize, the design of the ATLAS17LS and technology for its fabrication have been verified for implementation in the ITk. We are in the stage of sensor pre-production with the first sensors already delivered in January of 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. Here, the total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplicity trigger detector for the S π RIT experiment

A multiplicity trigger detector (MTD) was developed for the SπRIT experiment that aims to probe the high- density symmetry energy via heavy-ion collisions (HICs). The MTD is designed to measure the charged-particle multiplicity in HICs to provide a trigger signal that can be used to select high-multiplicity events induced by central collisions. The MTD consists of two side-walls segmented into 30 plastic scintillation paddles, each equipped with a multi-pixel photon counter. A custom board with EASIROC front-end ASIC is used as readout electronics. A multiplicity logic signal is generated by an on-board FPGA that processes the discriminated signals from EASIROCs. The overall latency of the whole detector system for outputting the trigger is less than 100 ns, including 52 ns of electronics latency for processing the signals. During the measurement of 112 Sn + 124 Sn reactions at an incident energy of 270 MeV/nucleon, the minimum multiplicity threshold of the MTD was set to 4, where the overall trigger efficiency was obtained to be about 39 % for inclusive nuclear reactions. Furthermore, a simulation study with a numerical calculation of HICs found that the central collisions of impact parameters of less than 4 fm can be triggered with a high efficiency of more than 95 % by the experimental trigger condition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Reduction of ion backflow using a quadruple GEM detector with various gas mixtures

In gaseous tracking detectors with a large gaseous volume, like Time Projection Chambers (TPC), multiple layers of Gas Electron Multipliers (GEM) can be used to block positive ions from flowing back into the active volume, which is detrimental to the tracking performance. TPCs with multilayer GEM readout are used in the recently upgraded ALICE experiment, and in the upcoming sPHENIX experiment. In both cases, suppression of ion backflow (IBF) is important for achieving the desired detector performance. Here, we report on studies of effective gain, IBF, and energy resolution in quadruple GEM detectors, and on strategies for minimizing IBF by optimizing the operating voltages of the individual GEM layers and the potential differences between different layers. These studies are performed as baseline measurements intended to aid in the optimization of the operating conditions of the GEMs of the sPHENIX TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital pulse analysis for fast neutron recoil spectroscopy with a 4 He scintillation detector

Helium-4-based fast neutron scintillation detectors are an attractive alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, as the response of the detectors to gamma rays is intrinsically limited to low energy deposition. Consequently, the neutron recoil distribution can be measured with these detectors without the need for pulse shape analysis. In this work, the response of an Arktis S670 4 He scintillation detector to D-D, D-T, and 252 Cf neutrons was measured. The detector has a unique construction and readout mechanism, with multiple output channels observing the same scintillation event, and an analysis method was developed to aggregate the outputs from all channels into a single list. The D-D and D-T neutron responses were used to perform a two-point energy calibration, which yielded a near-zero intercept, suggesting that the 4 He scintillation medium behaves linearly to a higher energy than previously reported, and that a two-point calibration is sufficient for nuclear recoil energies below 9 MeV. As a result, the detector was measured to have 16.7-ns FWHM time resolution when using the developed custom analysis, a reduction of 4.9 ns when compared to the conventional pulse analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalized method for the optimization of pulse shape discrimination parameters

Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and discriminated. In neutron measurements for nuclear security and non proliferation effective PSD is crucial, because a weak neutron signature needs to be detected in the presence of a strong gamma-ray background. Here, the most commonly used deterministic PSD technique is charge integration (CI). This method requires the optimization of specific parameters to obtain the best gamma-neutron separation. These parameters depend on the scintillating material and light readout device and typically require a lengthy optimization process and a calibration reference measurement with a mixed source. In this paper, we propose a new method based on the scintillation fluorescence physics that enables to find the optimum PSD integration gates using only a gamma-ray emitter. We demonstrate our method using three organic scintillation detectors: deuterated trans-stilbene, small-molecule organic glass, and EJ-309. In all the investigated cases, our method allowed finding the optimum PSD CI parameters without the need of iterative optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-pixel AI for lossy data compression at source for X-ray detectors

Integrating neural networks for data compression directly in the Read-Out Integrated Circuits (ROICs), i.e. the pixelated front-end, would result in a significant reduction in off-chip data transfer, overcoming the I/O bottleneck. Our ROIC test chip (AI-In-Pixel-65) is designed in a 65 nm Low Power CMOS process for the readout of pixelated X-ray detectors. Each pixel consists of an analog front-end for signal processing and a 10b analog-to-digital converter operating at 100KSPS. Here, we compare two non-reconfigurable techniques, Principal Component Analysis (PCA) and an AutoEncoder (AE) as lossy data compression engines implemented within the pixelated area. The PCA algorithm achieves 50$×$ compression, adds one clock cycle latency, and results in a 21% increase in the pixel area. The AE achieves 70$×$ compression, adds 30 clock cycle latency, and results in a similar area increase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of LAPPD timing at CERN PS testbeam

Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of EJ-270 and Ce-doped LiCAF scintillators for the development of high-rate neutron reflectometer detectors

The Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory is anticipated to provide a neutron source with ∼20 times increase in peak brightness than the First Target Station. The neutron reflectometers currently in operation at the First Target Station need to be upgraded due to the increased neutron flux. A prototype neutron detector module based upon a pixelated scintillator array readout by silicon photomultipliers is being developed to address the high-rate challenge faced with future neutron reflectometer instruments at the Second Target Station. Two types of scintillator materials were considered for this detector development, i.e., 6 Li-loaded EJ-270 plastic scintillator and Ce-doped LiCAF single crystal. This paper reports the scintillator characterization results, including light yield, pulse shape discrimination performance, capability to detect thermal neutrons in a high γ-ray field, and γ-ray sensitivity. The number of photons produced per neutron capture by EJ-270 and LiCAF:Ce was measured to be 2176 ± 91 and 2651 ± 108, respectively. EJ-270 demonstrated a good capability to discriminate between neutrons and γ-rays by employing the commonly used charge comparison method (figure-of-merit: 1.13 ± 0.01 for an energy cut of 292–426 keVee) and a reasonable performance when using the time-over-threshold techniques; however, no discrimination was observed from LiCAF:Ce regardless of the pulse shape discrimination approaches utilized, making pulse height discrimination necessary for LiCAF:Ce to differentiate between neutrons and γ-rays. Both EJ-270 and LiCAF:Ce exhibited an acceptable capacity to detect thermal neutrons at high exposure rates up to approximately 584 mR/h. Furthermore, the γ-ray sensitivities measured with a 60 Co source at an exposure rate of around 1145 mR/h were determined to be (6.11 ± 0.87) × 10 −6 and (7.64 ± 1.08) × 10 −7 for EJ-270 and LiCAF:Ce, respectively.

EJ-270↗