Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Addressing the spin question in gravitational-wave searches: Waveform templates for inspiralling compact binaries with nonprecessing spins

This paper presents a post-Newtonian (PN) template family of gravitational waveforms from inspiralling compact binaries with nonprecessing spins, where the spin effects are described by a single 'reduced-spin' parameter. This template family, which reparametrizes all the spin-dependent PN terms in terms of the leading-order (1.5PN) spin-orbit coupling term in an approximate way, has very high overlaps (fitting factor >0.99) with nonprecessing binaries with arbitrary mass ratios and spins. We also show that this template family is 'effectual' for the detection of a significant fraction of generic spinning binaries in the comparable-mass regime (m{sub 2}/m{sub 1} < or approx. 10), providing an attractive and feasible way of searching for gravitational waves from spinning low-mass binaries. We also show that the secular (nonoscillatory) spin-dependent effects in the phase evolution (which are taken into account by the nonprecessing templates) are more important than the oscillatory effects of precession in the comparable-mass (m{sub 1}{approx_equal}m{sub 2}) regime. Hence the effectualness of nonspinning templates is particularly poor in this case, as compared to non-precessing-spin templates. For the case of binary neutron stars observable by Advanced LIGO, even moderate spins (L-circumflex{sub N}{center_dot}S/m{sup 2}{approx_equal}0.015-0.1) will cause considerable mismatches ({approx}3%-25%) with nonspinning templates. This is contrary to the expectation that neutron-star spins may not be relevant for gravitational wave detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Superconducting source for tunable coherent terahertz radiation

A system includes a solid state source of THz radiation and a detector. The source of THz radiation may be based on a superconducting material, such as materials containing one or more Josephson junctions (e.g. BSCCO). The source may include a crystal of superconducting material on which a mesa of superconducting material is formed. The resonant coupling between the Josephson oscillations and the fundamental cavity mode of the mesa may lead to synchronization of the Josephson junctions and emission of powerful THz radiation. The mesa may be formed and/or handled such that THz radiation can be emitted by the material without requiring application of an external magnetic field (e.g. the mesa may include a non-uniform compositional gradient, a non-uniform shape, may have radiation non-uniformly applied to the mesa, etc.).

Koshelev, Alexei E.↗

Biology and Medicine, Spring 1965 Semiannual report

Reports on radiobiology studies, pion studies with silicon detectors, immunology, ultracentrifuge rotor temperature and speed measurement by radio telemetry, and radiosensitivity investigations

RADIOBIOLOGY↗

R and D towards huge liquid argon detectors for nucleon decay, neutrino astrophysics and CP-violation in the lepton sector

There are several R and D efforts around the world working toward huge liquid argon detectors for nucleon decay, neutrino astrophysics and CP-violation in the lepton sector. In this proceedings, we describe several R and D tasks. Some of the differences between those techniques will be covered, as well as the current status of those efforts. We will describe a recently developed technique called the double phase detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exotic Nuclei

Current experimental developments on the study of exotic nuclei far from the valley of stability are discussed. I start with general aspects related to the production of radioactive beams followed by the description of some of the experimental tools and specialized techniques for studies in reaction spectroscopy, nuclear structure research and nuclear applications with examples from selected topical areas with which I have been involved. I discuss some of the common challenges faced in Accelerator Mass Spectrometry (AMS) and Radioactive Ion Beam (RIB) science.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental observation of ion beams in the Madison Helicon eXperiment

Argon ion beams up to E{sub b} = 165 eV at P{sub rf} = 500 W are observed in the Madison Helicon eXperiment (MadHeX) helicon source with a magnetic nozzle. A two-grid retarding potential analyzer (RPA) is used to measure the ion energy distribution, and emissive and rf-filtered Langmuir probes measure the plasma potential, electron density, and temperature. The supersonic ion beam (M = v{sub i}/c{sub s} up to 5) forms over tens of Debye lengths and extends spatially for a few ion-neutral charge-exchange mean free paths. The parametric variation of the ion beam energy is explored, including flow rate, rf power, and magnetic field dependence. The beam energy is equal to the difference in plasma potentials in the Pyrex chamber and the grounded expansion chamber. The plasma potential in the expansion chamber remains near the predicted eV{sub p} {approx} 5kT{sub e} for argon, but the upstream potential is much higher, likely due to wall charging, resulting in accelerated ion beam energies E{sub b} = e[V{sub beam} - V{sub plasma}] > 10kT{sub e}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tracing the redshift evolution of Hubble parameter with gravitational-wave standard sirens

Proposed space-based gravitational-wave detectors such as BBO and DECIGO can detect {approx}10{sup 6} neutron star (NS) binaries and determine the luminosity distance to the binaries with high precision. Combining the luminosity distance and electromagnetically derived redshift, one would be able to probe cosmological expansion out to high redshift. In this paper, we show that the Hubble parameter as a function of redshift can be directly measured with monopole and dipole components of the luminosity distance on the sky. As a result, the measurement accuracies of the Hubble parameter in each redshift bin up to z=1 are 3-14%, 1.5-8%, and 0.8-4% for the observation time 1 yr, 3 yr, and 10 yr, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Polarization and Search for CP Violation in B{sub s}{sup 0}{yields}{phi}{phi} Decays

We present the first measurement of polarization and CP-violating asymmetries in a B{sub s}{sup 0} decay into two light vector mesons, B{sub s}{sup 0}{yields}{phi}{phi}, and an improved determination of its branching ratio using 295 decays reconstructed in a data sample corresponding to 2.9 fb{sup -1} of integrated luminosity collected by the CDF experiment at the Fermilab Tevatron collider. The fraction of longitudinal polarization is determined to be f{sub L}=0.348{+-}0.041(stat){+-}0.021(syst), and the branching ratio B(B{sub s}{sup 0}{yields}{phi}{phi})=[2.32{+-}0.18(stat){+-}0.82(syst)]x10{sup -5}. Asymmetries of decay angle distributions sensitive to CP violation are measured to be A{sub u}=-0.007{+-}0.064(stat){+-}0.018(syst) and A{sub v}=-0.120{+-}0.064(stat){+-}0.016(syst).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the matrix element for the decay {eta}' {yields} {eta}{pi}0{pi}0 with the GAMS-4{pi} spectrometer

The parameters of the Dalitz diagram for the decay {eta}' {yields} {eta}{pi}0{pi}0 in a generalized and a linear representation were determined by using a statistical sample of 15 x 10{sup 3} events. A charge-exchange reaction at a momentum of 32 GeV/c was a source of monoenergetic {eta}' mesons. The experiment was performed with the aid of the GAMS-4{pi} spectrometer.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formation of a narrow baryon resonance with positive strangeness in K{sup +} collisions with Xe nuclei

The data on the charge-exchange reaction K{sup +}Xe {sup {yields}}K{sup 0}pXe', obtained with the bubble chamber DIANA, are reanalyzed using increased statistics and updated selections. Our previous evidence for formation of a narrow pK{sup 0} resonance with mass near 1538 MeV is confirmed. The statistical significance of the signal reaches some 8{sigma} (6{sigma}) standard deviations when estimated as S/{radical}B (S/{radical}B + S. The mass and intrinsic width of the {Theta}{sup +} baryon are measured as m = 1538 {+-} 2 MeV and {Gamma} = 0.39 {+-} 0.10 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects

Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed tomography (CT) scanners. These PCXDs have great potential to improve the quality of CT images due to the absence of electronic noise and weights applied to the counts and the additional spectral information. With high count rates encountered in clinical CT, however, coincident photons are recorded as one event with a higher or lower energy due to the finite speed of the PCXD. This phenomenon is called a ''pulse pileup event'' and results in both a loss of counts (called ''deadtime losses'') and distortion of the recorded energy spectrum. Even though the performance of PCXDs is being improved, it is essential to develop algorithmic methods based on accurate models of the properties of detectors to compensate for these effects. To date, only one PCXD (model DXMCT-1, DxRay, Inc., Northridge, CA) has been used for clinical CT studies. The aim of that study was to evaluate the agreement between data measured by DXMCT-1 and those predicted by analytical models for the energy response, the deadtime losses, and the distorted recorded spectrum caused by pulse pileup effects. Methods: An energy calibration was performed using {sup 99m}Tc (140 keV), {sup 57}Co (122 keV), and an x-ray beam obtained with four x-ray tube voltages (35, 50, 65, and 80 kVp). The DXMCT-1 was placed 150 mm from the x-ray focal spot; the count rates and the spectra were recorded at various tube current values from 10 to 500 {mu}A for a tube voltage of 80 kVp. Using these measurements, for each pulse height comparator we estimated three parameters describing the photon energy-pulse height curve, the detector deadtime {tau}, a coefficient k that relates the x-ray tube current I to an incident count rate a by a=kxI, and the incident spectrum. The mean pulse shape of all comparators was acquired in a separate study and was used in the model to estimate the distorted recorded spectrum. The agreement between data measured by the DXMCT-1 and those predicted by the models was quantified by the coefficient of variation (COV), i.e., the root mean square difference divided by the mean of the measurement. Results: Photon energy versus pulse height curves calculated with an analytical model and those measured using the DXMCT-1 were in agreement within 0.2% in terms of the COV. The COV between the output count rates measured and those predicted by analytical models was 2.5% for deadtime losses of up to 60%. The COVs between spectra measured and those predicted by the detector model were within 3.7%-7.2% with deadtime losses of 19%-46%. Conclusions: It has been demonstrated that the performance of the DXMCT-1 agreed exceptionally well with the analytical models regarding the energy response, the count rate, and the recorded spectrum with pulse pileup effects. These models will be useful in developing methods to compensate for these effects in PCXD-based clinical CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A review of advances in pixel detectors for experiments with high rate and radiation

The large Hadron collider (LHC) experiments ATLAS and CMS have established hybrid pixel detectors as the instrument of choice for particle tracking and vertexing in high rate and radiation environments, as they operate close to the LHC interaction points. With the high luminosity-LHC upgrade now in sight, for which the tracking detectors will be completely replaced, new generations of pixel detectors are being devised. They have to address enormous challenges in terms of data throughput and radiation levels, ionizing and non-ionizing, that harm the sensing and readout parts of pixel detectors alike. Advances in microelectronics and microprocessing technologies now enable large scale detector designs with unprecedented performance in measurement precision (space and time), radiation hard sensors and readout chips, hybridization techniques, lightweight supports, and fully monolithic approaches to meet these challenges. In conclusion, this paper reviews the world-wide effort on these developments.

47 OTHER INSTRUMENTATION↗

Active Correlation Technique: Status and Development

During the recent years, at the FLNR (JINR) a successful cycle of experiments has been accomplished on the synthesis of the superheavy elements with Z = 112-118 with {sup 48}Ca beam. From the viewpoint of the detection of rare decays and background suppression, this success was achieved due to the application of a new radical technique--the method of active correlations. The method employs search in a real-time mode for a pointer to a probable correlation like recoil-alpha for switching the beam off. In the case of detection in the same detector strip an additional alpha-decay event, of 'beam OFF' time interval is prolonged automatically.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗