Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Effect of bed pressure drop on performance of a CFB boiler

The effect of bed pressure drop and bed inventory on the performances of a circulating fluidized bed (CFB) boiler was studied. By using the state specification design theory, the fluidization state of the gas-solids flow in the furnace of conventional CFB boilers was reconstructed to operate at a much lower bed pressure drop by reducing bed inventory and control bed quality. Through theoretical analysis, it was suggested that there would exist a theoretical optimal value of bed pressure drop, around which the boiler operation can achieve the maximal combustion efficiency and with significant reduction of the wear of the heating surface and fan energy consumption. The analysis was validated by field tests carried out in a 75 t/h CFB boiler. At full boiler load, when bed pressure drop was reduced from 7.3 to 3.2 kPa, the height of the dense zone in the lower furnace decreased, but the solid suspension density profile in the upper furnace and solid flow rate were barely influenced. Consequently, the average heat transfer coefficient in the furnace was kept nearly the same and the furnace temperature increment was less than 17{sup o}C. It was also found that the carbon content in the fly ash decreased first with decreasing bed pressure drop and then increased with further increasing bed pressure drop. The turning point with minimal carbon content was referred to as the point with optimal bed pressure drop. For this boiler, at the optimum point the bed pressure was around 5.7 kPa with the overall excess air ratio of 1.06. When the boiler was operated around this optimal point, not only the combustion efficiency was improved, but also fan energy consumption and wear of heating surface were reduced. 23 refs., 6 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

Storage Conditions of Human Kidney Tissue Sections Affect Spatial Lipidomics Analysis Reproducibility

Lipids often are labile, unstable, and tend to degrade overtime, so it is of the upmost importance to study these molecules in their most native state. In this study, we sought to understand the optimal storage conditions for spatial lipidomic analysis of human kidney tissue sections. Specifically, we evaluated human kidney tissue sections on several different days throughout the span of a week using our established protocol for elucidating lipids using high mass resolution matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). We studied kidney tissue sections stored under five different conditions: open stored at –80 °C, vacuumed sealed and stored at –80 °C, with matrix preapplied before storage at –80 °C, under a nitrogen atmosphere and stored at –80 °C, and at room temperature in a desiccator. Results were compared to data obtained from kidney tissue sections that were prepared and analyzed immediately after cryosectioning. Data was processed using METASPACE. After a week of storage, the sections stored at room temperature showed the largest amount of lipid degradation, while sections stored under nitrogen and at –80 °C retained the greatest number of overlapping annotations in relation to freshly cut tissue. Overall, we found that molecular degradation of the tissue sections was unavoidable over time, regardless of storage conditions, but storing tissue sections in an inert gas at low temperatures can curtail molecular degradation within tissue sections.

60 APPLIED LIFE SCIENCES↗

fluxfinder: An R Package for Reproducible Calculation and Initial Processing of Greenhouse Gas Fluxes From Static Chamber Measurements

Fluxes of greenhouse gases are a critical component of the earth's natural climate, but anthropogenic emissions have created an imbalance and resulted in global climate change. Quantifying the emission of these gases is vital to our understanding of their sources and sinks, both natural and anthropogenic. The static chamber method, in which a system of interest is enclosed, and gas concentrations are measured over time, is widely used to estimate fluxes of greenhouse gases. With the development of instruments such as infrared gas analyzers (IRGAs) supporting high-frequency concentration data, there is a growing need for open-source workflows to calculate fluxes. Here we present fluxfinder, an R package designed to support reproducible calculations and processing of greenhouse gas fluxes measured with the static chamber method. The package includes raw data file parsing from widely used IRGAs, metadata matching, unit conversion, flux estimations, and initial quality assurance/quality control (QA/QC). Diagnostic graphical plots provide a transparent way to differentiate between measurement issues and nonlinear behavior. The package is also designed to be easily integrated with the gasfluxes package for further fitting of nonlinear concentration-time models, allowing alternative or additional flux QA/QC. The fluxfinder package offers a flexible workflow that is easily adaptable to promote open and reproducible greenhouse gas flux estimations.

Wilson, Stephanie J.↗

Mountainous Floodplain Connectivity in Response to Hydrological Transitions

In mountainous watersheds, floodplain sediments are typically characterized by gravel bed layers capped by an overlying soil unit that serves as a hotspot for biogeochemical reactivity. However, the influence of soil biogeochemistry on gravel bed underflow composition remains unclear, especially during hydrological transitions that alter the vertical connectivity between overlaying soils and the underlying gravel bed. This study investigates these dynamics by measuring hydraulic gradients and water compositions over three hydrological years in a typical mountainous, low-order stream floodplain in the Upper Colorado River Basin. Results indicate that the timing of hydrological conditions strongly influences the vertical exchanges that control water quality. Specifically, during flooding events such as beaver ponding, that induce downward flushing of the soil, anoxic conditions prevalent in the biogeochemically active soil are transferred downstream via gravel bed underflow. Conversely, snowmelt and drought conditions increase oxic conditions in the gravel bed due to diminished hydrological connectivity with the overlying soil. To compare water quality response to hydrological transitions across similar floodplain environments, we propose a conceptual model that quantifies the inundation-induced flushing of soil porewater to measure solute exchange efficiency with the gravel bed solute convergence efficiency (SCE). This model provides a framework for quantifying biogeochemical processes in hydrological underflow systems, which is critical for water and elemental budgets in these globally important mountainous ecosystems.

58 GEOSCIENCES↗

A Performant, Scalable Processing Pipeline for High‐Quality and FAIR Environmental Sensor Data

High-resolution environmental monitoring is necessary to record, understand, and predict biogeochemical and ecological changes particularly in coastal systems but brings significant challenges in processing and making rapidly available the resulting data. The COMPASS-FME project established a network of coastal observational sites across the Chesapeake Bay and western Lake Erie regions extensively instrumented with soil, vegetation, and weather sensors logging data every 15 min. Our data processing framework, written in R and completely open source, prioritizes rapid model-experiment iteration and makes biogeochemical data rapidly available for quality assurance/quality control, analysis, and model ingestion. This pipeline is distinguished by a standardized and modular approach to data curation, extensive metadata and documentation, and its high performance. These attributes combine to make biogeochemical data rapidly accessible across COMPASS-FME and the broader community. Flexible, powerful, and reproducible approaches to handling high-volume environmental data are crucial for accelerating biogeosciences research.

Pennington, Stephanie C. [Pacific Northwest Nation↗

Beaver dams overshadow climate extremes in controlling riparian hydrology and water quality

Abstract Hydrologic extremes dominate chemical exports from riparian zones and dictate water quality in major river systems. Yet, changes in land use and ecosystem services alongside growing climate variability are altering hydrologic extremes and their coupled impacts on riverine water quality. In the western U.S., warming temperatures and intensified aridification are increasingly paired with the expanding range of the American beaver—and their dams, which transform hydrologic and biogeochemical cycles in riparian systems. Here, we show that beaver dams overshadow climatic hydrologic extremes in their effects on water residence time and oxygen and nitrogen fluxes in the riparian subsurface. In a mountainous watershed in Colorado, U.S.A., we find that the increase in riparian hydraulic gradients imposed by a beaver dam is 10.7–13.3 times greater than seasonal hydrologic extremes. The massive hydraulic gradient increases hyporheic nitrate removal by 44.2% relative to seasonal extremes alone. A drier, hotter climate in the western U.S. will further expand the range of beavers and magnify their impacts on watershed hydrology and biogeochemistry, illustrating that ecosystem feedbacks to climate change will alter water quality in river systems.

54 ENVIRONMENTAL SCIENCES↗

High frequency beam oscillation keyhole dynamics in laser melting revealed by in-situ x-ray imaging

The metal additive manufacturing industry is actively developing instruments and strategies to enable higher productivity, optimal build quality, and controllable as-built microstructure. A beam controlling technique, laser oscillation has shown potential in all these aspects in laser welding; however, few attempts have been made to understand the underlying physics of the oscillating keyholes/melt pools which are the prerequisites for these strategies to become a useful tool for laser-based additive manufacturing processes. Here, to address this gap, we utilized a synchrotron-based X-ray operando technique to image the dynamic keyhole oscillation in Ti-6Al-4V using a miniature powder bed fusion setup. We found good agreement between the experimental observations and simulations performed with a validated Lattice Boltzmann multiphysics model. The study revealed the continuous and periodic fluctuations in the characteristic keyhole parameters that are unique to the oscillating laser beam processing and responsible for the chevron pattern formation at solidification. In particular, despite the intrinsic longer-range fluctuation, the oscillating technique displayed potential for reducing keyhole instability, mitigating porosity formation, and altering surface topology. These insights on the oscillating keyhole dynamics can be useful for the future development and application of this technique.

36 MATERIALS SCIENCE↗

Functional metal–organic frameworks as effective sensors of gases and volatile compounds

Developing efficient sensor materials with superior performance for selective, fast and sensitive detection of gases and volatile organic compounds (VOCs) is essential for human health and environmental protection, through monitoring indoor and outdoor air pollutions, managing industrial processes, controlling food quality and assisting early diagnosis of diseases. Metal–organic frameworks (MOFs) are a unique type of crystalline and porous solid material constructed from metal nodes (metal ions or clusters) and functional organic ligands. They have been investigated extensively for possible use as high performance sensors for the detection of many different gases and VOCs in recent years, due to their large surface area, tunable pore size, functionalizable sites and intriguing properties, such as electrical conductivity, magnetism, ferroelectricity, luminescence and chromism. The high porosity of MOFs allows them to interact strongly with various analytes, including gases and VOCs, thus resulting in easily measurable responses to different physicochemical parameters. Although much of the recent work on MOF-based luminescent sensors have been summarized in several excellent reviews (up to 2018), a comprehensive overview of these materials for sensing gases and VOCs based on chemiresistive, magnetic, ferroelectric, and colorimertic mechanisms is missing. In this review, we highlight the most recent progress in developing MOF sensing and switching materials with an emphasis on sensing mechanisms based on electricity, magnetism, ferroelectricity and chromism. We provide a comprehensive analysis on the MOF–analyte interactions in these processes, which play a key role in the sensing performance of the MOF-based sensors and switches. We discuss in detail possible applications of MOF-based sensing and switching materials in detecting oxygen, water vapor, toxic industrial gases (such as hydrogen sulfide, ammonia, sulfur dioxide, nitrous oxide, carbon oxides and carbon disulfide) and VOCs (such as aromatic and aliphatic hydrocarbons, ketones, alcohols, aldehydes, chlorinated hydrocarbons and N,N'-dimethylformamide). Altogether, this review serves as a timely source of information and provides insight for the future development of advanced MOF materials as next-generation gas and VOC sensors.

36 MATERIALS SCIENCE↗

Weld Spot Detection by Color Segmentation and Template Convolution

There is a need of non-destructive evaluation of the quality of steel spot welds. A computer-vision based solution is presented performing the analysis of the weld spot imprints left by the electrode on the protection bands. In this paper we propose two different methods to locate the position of the weld spot imprint as a first step in order to verify the quality of the welding process; both methods consist of two stages: (i) the use of the X channel of the XYZ color space as a proper representation, and (ii) the analysis of this image channel by employing specific algorithms.

42 ENGINEERING↗

The theory of variances in equilibrium reconstruction

The theory of variances of equilibrium reconstruction is presented. It complements existing practices with information regarding what kind of plasma characteristics can be reconstructed, how accurately, and what remains beyond the abilities of diagnostic systems. The {sigma}-curves, introduced by the present theory, give a quantitative assessment of quality of effectiveness of diagnostic systems in constraining equilibrium reconstructions. The theory also suggests a method for aligning the accuracy of measurements of different physical nature and for improvements of numerical algorithms used in reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratory Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.

54 ENVIRONMENTAL SCIENCES↗

The National Dissemination of International Measurements

The paper presents the most significant actions which a primary Radionuclide Metrology Laboratory must accomplish, in order to disseminate the international equivalence to the entire national traceability chain: absolute standardization methods and demonstration of international equivalence, construction and calibration of a consistent set of secondary standardization equipment, preparation of radioactive standards. Delivery of radioactive standards to the end users and carrying out metrological services. Organization of national proficiency tests with the users. International validation of secondary standards by proficiency tests and establishment of a Quality System Assurance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new Role of Proficiency Testing in Nuclear Analytical Work

The most recent definition of measurement result requires a statement of uncertainty whenever results obtained by nuclear or other quantitative methods of analysis are reported. Proficiency testing (PT) therefore must include the ability of laboratories to present not only unbiased quantity values, but reliable estimates of their uncertainty. Hence, a reference value with the smallest possible uncertainty is needed to ascertain the proficiency of laboratories reporting results with lower than average uncertainty. A strategy based on the T-statistic is proposed leading to an accepted reference value that fully reflects the uncertainties reported by participants in a PT-scheme and permits calculation of En numbers to distinguish whether or not measurement results are consistent with the accepted definition of the measurand. The strategy is applied to PT-data from a recent international laboratory intercomparison of uranium isotopic ratios with very low reported uncertainties. In the paper this example is used to present the situation in the nuclear field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of IAEA /1/INT/054 Project in Nuclear Analytical Techniques Group of Argentina: Current State

This paper presents the implementation of the training received through the IAEA Project 'Preparation of Reference Materials and Organization of Proficiency Tests Rounds' in the Nuclear Analytical (NAT) Group of CNEA. Special emphasis is done on those activities related to the first Proficiency Test being carried out by the NAT Group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dosimetric Verification and Validation of Conformal and IMRT Treatments Fields with an Ionization Chamber 2D-Array

A three-dimensional treatment planning system requires comparisons of calculated and measured dose distributions. It is necessary to confirm by means of patient specific QA that the dose distributions are correctly calculated, and that the patient data is correctly transferred to and delivered by the treatment machine. We used an analysis software for bi-dimensional dosimetric verification of conformal treatment and IMRT fields using as objective criterion the gamma index. An ionization chamber bi-dimensional array was used for absolute dose measurement in the complete field area.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning Procedures for Mechanical Precision and Accuracy in a Dedicated LINAC

Mechanical precision measurements are fundamental procedures for the commissioning of a dedicated LINAC. At our Radioneurosurgery Unit, these procedures can be suitable as quality assurance routines that allow the verification of the equipment geometrical accuracy and precision. In this work mechanical tests were performed for gantry and table rotation, obtaining mean associated uncertainties of 0.3 mm and 0.71 mm, respectively. Using an anthropomorphic phantom and a series of localized surface markers, isocenter accuracy showed to be smaller than 0.86 mm for radiosurgery procedures and 0.95 mm for fractionated treatments with mask. All uncertainties were below tolerances. The highest contribution to mechanical variations is due to table rotation, so it is important to correct variations using a localization frame with printed overlays. Mechanical precision knowledge would allow to consider the statistical errors in the treatment planning volume margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Radiation Energy Response for Thermoluminescent Dosimeter TLD-100: Determination of Organ Dose in Diagnostic Radiology

TLD-100 (thermoluminescent dosimeter) cards (chips) were calibrated using X-rays with energies of 25-250 kV produced by a Cs-137 source. The energy responses of lithium fluoride crystals for different energies of X-rays were studied. QA/QC was then performed in the Albanian Ionizing Radiation Metrology Laboratory. Based on the QA/QC results, the chips were used to study the doses to different organs in diagnostic radiology. Organ dose was evaluated after calculation of e dose in air (Kair), using an ionizing chamber.

61 RADIATION PROTECTION AND DOSIMETRY↗