Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parameter Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

End-to-end orientation estimation from 2D cryo-EM1images

Cryo-electron microscopy (cryo-EM) is a Nobel Prize-winning technique for deter-mining high-resolution 3D structures of biological macromolecules. A 3D structure is reconstructed from hundreds of thousands of noisy 2D projection images. However, existing 3D reconstruction methods are still time-consuming, and one of the major computational bottlenecks is to recover the unknown orientation of the particle in16each 2D image. The dominant methods typically exploit expensive global search on each image to estimate the missing orientations. Here, a novel end-to-end supervised learning method is introduced to directly recover the missing orientations from 2D cryo-EM images. A neural network is used to approximate the mapping from images to orientations. Furthermore, a robust loss function is proposed for optimizing the parameters of the network, which can handle both asymmetric and symmetric 3D structures. Experiments on synthetic datasets with various symmetry types confirm that the neural network is capable of recovering orientations from 2D cryo-EM images, and the results on one real cryo-EM dataset further demonstrate its potential in more challenging imaging conditions.

3D reconstruction↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

A Novel Machine Learning Algorithm for Planetary Boundary Layer Height Estimation Using AERI Measurement Data

Accurately determining the height of the planetary boundary layer (PBL) is important since it can affect the climate, weather, and air quality. Ground-based infrared hyperspectral remote sensing is an effective way to obtain this parameter. Compared with radiosonde measurements, its temporal resolution is much higher. In this study, a method to retrieve the PBL height (PBLH) from the ground-based infrared hyperspectral radiance data is proposed based on machine learning. In this method, the channels that are sensitive to temperature and humidity profiles are selected as the feature vectors, and the PBLHs derived from radiosonde are taken as the true values. The support vector machine (SVM) is applied to train and test the data set, and the parameters are optimized in the process. The data set collected at the Atmospheric Radiation Measurement (ARM) program Southern Great Plains (SGP) from 2012 to 2015 is analyzed. The instruments used in this letter include Atmospheric Emitted Radiance Interferometer (AERI), Vaisala CL31 ceilometer, and radiosonde. It shows that the root mean square error (RMSE) between the PBLHs calculated by the proposed method using AERI data and those from radiosonde data can be within 370 m, and the square correlation coefficient (SCC) is greater than 0.7. Compared with the PBLHs derived from the ceilometer, it can be found that the new method is more stable and less affected by clouds.

54 ENVIRONMENTAL SCIENCES↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Automatic Detection and Evaluation of Solar Cell Micro-Cracks in Electroluminescence Images Using Matched Filters

A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potential for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.

14 SOLAR ENERGY↗

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Spark plasma sintering of structure-tailored ultrahigh-temperature components: First step to complex net shaping

The net-shaping capability in spark plasma sintering (SPS) of ultrahigh-temperature ceramics has been explored in this study. The annular or ring-like shape is considered here as the first step to a more complex geometry compared to a solid cylinder or disk. ZrC powders have been SPS processed in specially designed graphite tooling to achieve the annular shape geometry. Experimental runs have been carried out to determine the optimal processing parameters for producing highly dense ZrC specimens in this geometry. Finite-element modeling framework has been constructed to determine the internal stress evolution, as well as densification, during the SPS of the annular-shaped ZrC. The formulated processing schemes for ZrC have been adapted to process SiC/ZrB2 composite powder with the purpose of making tooling components for SPS applications. The applicability of the obtained composite SPS tooling has been evaluated at high temperature and high pressure associated with SPS regimes.

36 MATERIALS SCIENCE↗

Hydrokinetic Energy Conversion by Flow-Induced Oscillation of Two Tandem Cylinders of Different Stiffness

Abstract The vortex-induced vibration for aquatic clean energy (VIVACE) converter harnesses hydrokinetic energy by enhancing flow-induced oscillations (FIOs) of elastically supported rigid cylinders in a river, tide, or ocean current. The harnessing power depends on the intensity of the oscillation, which is a consequence of the flow–structure interaction. The inflow condition for the downstream (second) cylinder is slowed down and perturbed by the upstream (first) cylinder, due to the shielding effect. Therefore, the optimal structural parameters, i.e., stiffness and damping ratio, for the second cylinder may be different from the first cylinder, in terms of energy harnessing. To improve the performance of the VIVACE converter, a series of experiments are conducted in a recirculating water channel, with various stiffness combinations of two cylinders in tandem. Results show that the stiffness of the second cylinder, K2, does not affect the energy harnessing power in vortex-induced vibration (VIV) occurring at low speeds, because the oscillation of the downstream cylinder in this velocity range is completely dominated by the wake of the upstream cylinder. K2 has a great influence on the harnessing power at higher velocities in the transition region from VIV to galloping and in galloping. Changing K2 onsets and enhances galloping at lower flow velocity and harnesses up to 110% more energy than the case of K1 = K2.

Engineering↗

Additive Manufacturing of Porous Ceramics With Foaming Agent

The macro-porous ceramics has promising durability and thermal insulation performance. As porous ceramics find more and more applications across many industries, a cost-effective and scalable additive manufacturing technique for fabricating macro-porous ceramics is highly desirable. Herein, we reported a facile additive manufacturing approach to fabricate porous ceramics and control the printed porosity. Several printable ceramic inks were prepared, and the foaming agent was added to generate gaseous bubbles in the ink, followed by the direct ink writing and the ambient-pressure and room-temperature drying to create the three-dimensional geometries. In this work, a set of experimental studies were performed to optimize the printing quality. The results revealed the optimal process parameters for printing the foamed ceramic ink with a high spatial resolution and fine surface quality. Varying the concentration of the foaming agent enables the controllability of the structural porosity. The maximum porosity can reach 85%, with a crack-free internal porous structure. The tensile tests showed that the printed macro-porous ceramics possessed enhanced durability with the addition of fiber. With a high-fidelity three-dimensional (3D) printing process and the precise controllability of the porosity, we showed that the printed samples exhibited a remarkably low thermal conductivity and durable mechanical strength.

36 MATERIALS SCIENCE↗

ASSESSING THE EFFECTIVENESS OF ULTRASONIC IMPACT TREATMENT ON RESIDUAL STRESS PROFILES IN DISSIMILAR WELDED JOINTS

Residual stresses (RS) induced during welding processes are a critical concern in materials engineering, as they can significantly impair the mechanical performance of components by reducing fatigue strength and tensile load capacity. This challenge is especially pronounced in dissimilar metal welds (DMWs), where variations in thermal expansion properties between the joined alloys exacerbate the formation of tensile RS. Conventional post-weld heat treatments, though effective for homogeneous materials, often require substantial energy, specialized equipment, and extensive processing time, making them less practical for DMW applications. Thus, there is a clear need for innovative, energy-efficient techniques to mitigate these detrimental stresses. This study investigates ultrasonic impact treatment (UIT) as a possible alternative for mitigating tensile RS in both similar and dissimilar metal welds. To evaluate UIT’s effectiveness, neutron diffraction (ND) was employed as a nondestructive technique to quantify RS in three orthogonal directions—longitudinal, transverse, and normal. The results showed that UIT significantly reduced peak tensile RS, particularly in the longitudinal direction, by up to 180 MPa in similar welds and up to 150 MPa in dissimilar welds. Given the limited literature on UIT application in DMWs, this work contributes valuable data on stress redistribution mechanisms and highlights UIT’s potential as a practical stress-relief method. The findings lay the groundwork for further investigations aimed at optimizing process parameters and understanding long-term performance in welded joints.

EisaZadeh, Hamid [Western Carolina University, Cul↗

Nb 3 Sn coating of SRF cavity by cosputtering from a composite target

Here, we deposited an Nb 3 Sn film on the inner surface of a 2.6 GHz Nb superconducting radio frequency cavity by cosputtering using a composite of Nb and Sn tube targets in a DC cylindrical magnetron sputtering system, followed by the thermal annealing of the coated cavity. An aluminum mockup cavity, replicating a 2.6 GHz Nb SRF cavity geometry, was utilized to optimize deposition parameters, resulting in cosputtered Nb–Sn films with an Sn content of 32–42 at. % on the beam tubes and equator positions. Several annealing conditions were investigated to improve the surface homogeneity of the Nb 3 Sn film. The best cosputtered Nb–Sn film was achieved after annealing at 600 °C for 6 h, followed by annealing at 950 °C for 1 h. The best process was applied to a Nb cavity, which was RF tested in a cryogenic dewar. RF testing of the Nb 3 Sn-coated cavity demonstrated a superconducting transition temperature of 17.78 K. The Nb 3 Sn cavity underwent light Sn recoating, followed by additional RF testing, resulting in the enhancement of the RF performance, primarily due to the improved surface homogeneity of the Nb 3 Sn coating.

Nb3Sn film↗

Optimized illumination for high-throughput ptychography

As a scanning version of coherent diffraction imaging (CDI), X-ray ptychography has become a popular and very successful method for high-resolution quantitative imaging of extended specimens. The requirements of mostly coherent illumination and the scanning mechanism limit the throughput of ptychographic imaging. In this paper, we will introduce the methods we use at the Advanced Photon Source (APS) to achieve high-throughput ptychography by optimizing the parameters of the illumination beam. One work we have done is increasing the illumination flux by using a double-multilayer monochromator (DMM) optics with about 0.8% bandwidth. Compared with our double-crystal monochromator (DCM) optics with 0.01% bandwidth, this DMM optics provides around 20 times more flux. A multi-wavelength reconstruction method has been implemented to deal with the consequential degraded temporal coherence from such an illumination to ensure high-quality reconstruction. In the other work, we adopt a novel use of flat-top focusing optics to generate a flat-top beam with the diameter of about 1.5 µm on the focal plane. The better uniformity of the probe and the large beam size allow one to significantly increase the step size in ptychography scans and thereby the imaging efficiency.

Broad bandwidth↗

Machine learning-driven design and self-sensing capabilities of automotive bumper lattices for adaptive impact response

We present a novel approach to design an automotive bumper energy absorber using carbon fiber reinforced polymer composites, optimized to meet conflicting performance requirements for two distinct impact scenarios. The design must satisfy both a low-speed (2.5 mph) pendulum intrusion test, simulating vehicle-to-vehicle collisions, and a high-speed (25 mph) leg flexion test, replicating pedestrian impacts. These tests demand opposing deformation characteristics: high flexibility (deformation < 85 mm) for the former and high stiffness (deformation < 22 mm) for the latter. To address these contradictory requirements, we developed a machine learning (ML) framework for inverse optimization of lattice designs and material selection. Unlike traditional iterative design processes, our ML model directly outputs optimal design parameters and material choices based on target performance inputs. The energy absorber was fabricated using advanced additive manufacturing techniques, including extrusion deposition and digital light processing. The integration of carbon fibers provides multifunctionality to the bumper structure, enabling self-sensing capabilities through changes in electrical resistivity under compression. This electrical response demonstrates high repeatability under multiple cycles at 2% compression and exhibits distinct signatures during crack formation under high deformation. This research offers adaptive performance through innovative design methodologies and smart material integration. The approach has potential applications in various fields requiring adaptive energy absorption and real-time structural health monitoring.

Chawla, Komal [ORNL] (ORCID:0000000190327565)↗

A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections

Purpose: To develop a technique to estimate onboard 4D-CBCT using prior information and limited-angle projections for potential 4D target verification of lung radiotherapy.Methods: Each phase of onboard 4D-CBCT is considered as a deformation from one selected phase (prior volume) of the planning 4D-CT. The deformation field maps (DFMs) are solved using a motion modeling and free-form deformation (MM-FD) technique. In the MM-FD technique, the DFMs are estimated using a motion model which is extracted from planning 4D-CT based on principal component analysis (PCA). The motion model parameters are optimized by matching the digitally reconstructed radiographs of the deformed volumes to the limited-angle onboard projections (data fidelity constraint). Afterward, the estimated DFMs are fine-tuned using a FD model based on data fidelity constraint and deformation energy minimization. The 4D digital extended-cardiac-torso phantom was used to evaluate the MM-FD technique. A lung patient with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume, including changes of respiration amplitude, lesion size and lesion average-position, and phase shift between lesion and body respiratory cycle. The lesions were contoured in both the estimated and “ground-truth” onboard 4D-CBCT for comparison. 3D volume percentage-difference (VPD) and center-of-mass shift (COMS) were calculated to evaluate the estimation accuracy of three techniques: MM-FD, MM-only, and FD-only. Different onboard projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy.Results: For all simulated patient and projection acquisition scenarios, the mean VPD (±S.D.)/COMS (±S.D.) between lesions in prior images and “ground-truth” onboard images were 136.11% (±42.76%)/15.5 mm (±3.9 mm). Using orthogonal-view 15°-each scan angle, the mean VPD/COMS between the lesion in estimated and “ground-truth” onboard images for MM-only, FD-only, and MM-FD techniques were 60.10% (±27.17%)/4.9 mm (±3.0 mm), 96.07% (±31.48%)/12.1 mm (±3.9 mm) and 11.45% (±9.37%)/1.3 mm (±1.3 mm), respectively. For orthogonal-view 30°-each scan angle, the corresponding results were 59.16% (±26.66%)/4.9 mm (±3.0 mm), 75.98% (±27.21%)/9.9 mm (±4.0 mm), and 5.22% (±2.12%)/0.5 mm (±0.4 mm). For single-view scan angles of 3°, 30°, and 60°, the results for MM-FD technique were 32.77% (±17.87%)/3.2 mm (±2.2 mm), 24.57% (±18.18%)/2.9 mm (±2.0 mm), and 10.48% (±9.50%)/1.1 mm (±1.3 mm), respectively. For projection angular-sampling-intervals of 0.6°, 1.2°, and 2.5° with the orthogonal-view 30°-each scan angle, the MM-FD technique generated similar VPD (maximum deviation 2.91%) and COMS (maximum deviation 0.6 mm), while sparser sampling yielded larger VPD/COMS. With equal number of projections, the estimation results using scattered 360° scan angle were slightly better than those using orthogonal-view 30°-each scan angle. The estimation accuracy of MM-FD technique declined as noise level increased.Conclusions: The MM-FD technique substantially improves the estimation accuracy for onboard 4D-CBCT using prior planning 4D-CT and limited-angle projections, compared to the MM-only and FD-only techniques. It can potentially be used for the inter/intrafractional 4D-localization verification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-247: Multi-Leaf Collimator Model Adjustments Improve Small Field Dosimetry in VMAT Plans

Purpose: The Elekta beam modulator linac employs a 4-mm micro multileaf collimator (MLC) backed by a fixed jaw. Out-of-field dose discrepancies between treatment planning system (TPS) calculations and output water phantom measurements are caused by the 1-mm leaf gap required for all moving MLCs in a VMAT arc. In this study, MLC parameters are optimized to improve TPS out-of-field dose approximations. Methods: Static 2.4 cm square fields were created with a 1-mm leaf gap for MLCs that would normally park behind the jaw. Doses in the open field and leaf gap were measured with an A16 micro ion chamber and EDR2 film for comparison with corresponding point doses in the Pinnacle TPS. The MLC offset table and tip radius were adjusted until TPS point doses agreed with photon measurements. Improvements to the beam models were tested using static arcs consisting of square fields ranging from 1.6 to 14.0 cm, with 45° collimator rotation, and 1-mm leaf gap to replicate VMAT conditions. Gamma values for the 3-mm distance, 3% dose difference criteria were evaluated using standard QA procedures with a cylindrical detector array. Results: The best agreement in point doses within the leaf gap and open field was achieved by offsetting the default rounded leaf end table by 0.1 cm and adjusting the leaf tip radius to 13 cm. Improvements in TPS models for 6 and 10 MV photon beams were more significant for smaller field sizes 3.6 cm or less where the initial gamma factors progressively increased as field size decreased, i.e. for a 1.6cm field size, the Gamma increased from 56.1% to 98.8%. Conclusion: The MLC optimization techniques developed will achieve greater dosimetric accuracy in small field VMAT treatment plans for fixed jaw linear accelerators. Accurate predictions of dose to organs at risk may reduce adverse effects of radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T{sub 1}-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results: The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. Conclusions: We showed that a patch-based method could generate an accurate pCT based on conventional T{sub 1}-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.

60 APPLIED LIFE SCIENCES↗

Treatment planning for radiotherapy with very high-energy electron beams and comparison of VHEE and VMAT plans

Purpose: The aim of this work was to develop a treatment planning workflow for rapid radiotherapy delivered with very high-energy electron (VHEE) scanning pencil beams of 60–120 MeV and to study VHEE plans as a function of VHEE treatment parameters. Additionally, VHEE plans were compared to clinical state-of-the-art volumetric modulated arc therapy (VMAT) photon plans for three cases. Methods: VHEE radiotherapy treatment planning was performed by linking EGSnrc Monte Carlo (MC) dose calculations with inverse treatment planning in a research version of RayStation. In order to study the effect of VHEE treatment parameters on VHEE dose distributions, a MATLAB graphical user interface (GUI) for calculation of VHEE MC pencil beam doses was developed. Through the GUI, pediatric case MC simulations were run for a number of beam energies (60, 80, 100, and 120 MeV), number of beams (13, 17, and 36), pencil beam spot (0.1, 1.0, and 3.0 mm) and grid (2.0, 2.5, and 3.5 mm) sizes, and source-to-axis distance, SAD (40 and 50 cm). VHEE plans for the pediatric case calculated with the different treatment parameters were optimized and compared. Furthermore, 100 MeV VHEE plans for the pediatric case, a lung, and a prostate case were calculated and compared to the clinically delivered VMAT plans. All plans were normalized such that the 100% isodose line covered 95% of the target volume. Results: VHEE beam energy had the largest effect on the quality of dose distributions of the pediatric case. For the same target dose, the mean doses to organs at risk (OARs) decreased by 5%–16% when planned with 100 MeV compared to 60 MeV, but there was no further improvement in the 120 MeV plan. VHEE plans calculated with 36 beams outperformed plans calculated with 13 and 17 beams, but to a more modest degree (<8%). While pencil beam spacing and SAD had a small effect on VHEE dose distributions, 0.1–3 mm pencil beam sizes resulted in identical dose distributions. For the 100 MeV VHEE pediatric plan, OAR doses were up to 70% lower and the integral dose was 33% lower for VHEE compared to 6 MV VMAT. Additionally, VHEE conformity indices (CI{sub 100} = 1.09 and CI{sub 50} = 4.07) were better than VMAT conformity indices (CI{sub 100} = 1.30 and CI{sub 50} = 6.81). The 100 MeV VHEE lung plan resulted in mean dose decrease to all OARs by up to 27% for the same target coverage compared to the clinical 6 MV flattening filter-free (FFF) VMAT plan. The 100 MeV prostate plan resulted in 3% mean dose increase to the penile bulb and the urethra, but all other OAR mean doses were lower compared to the 15 MV VMAT plan. The lung case CI{sub 100} and CI{sub 50} conformity indices were 3% and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. The prostate case CI{sub 100} and CI{sub 50} conformity indices were 1% higher and 8% lower, respectively, in the VHEE plan compared to the VMAT plan. Conclusions: The authors have developed a treatment planning workflow for MC dose calculation of pencil beams and optimization for treatment planning of VHEE radiotherapy. The authors have demonstrated that VHEE plans resulted in similar or superior dose distributions for pediatric, lung, and prostate cases compared to clinical VMAT plans.

60 APPLIED LIFE SCIENCES↗