Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Landsat-4 on-board ephemeris determination utilizing the Global Positioning System

The Global Positioning System (GPS) is a worldwide system of navigation data satellites currently being deployed by the United States for land, sea, air and space-borne users. Currently several development satellites have been launched for system evaluation. Eventually the system will include 18 operational satellites. The GPS system utilizes precision clocks to allow users to measure the one-way propagation delay of navigational signals from the satellites, so that users can infer their position by decoding the navigation signal and observing the delay from several satellites. Landsat-4 is the first spacecraft to carry a GPS navigation system into orbit. This paper describes the Landsat-4 GPS experiment, Landsat-4 requirements for ephemeris data and the in-flight performance of the system.

Korenstein, D. A.↗

A model of the polarization position-angle swings in BL Lacertae objects

The polarization position-angle swings that have been measured in a number of BL Lacertae objects and highly variable quasars are interpreted in terms of shock waves which illuminate (by enhanced synchrotron radiation) successive transverse cross sections of a magnetized, relativistic jet. The jet is assumed to have a nonaxisymmetric magnetic field configuration of the type discussed in the companion paper on the equilibria of force-free jets. For a jet that is viewed at a small angle to the axis, the passage of a shock will give rise to an apparent rotation of the polarization position angle whose amplitude can be substantially larger than 180 deg. The effects of freely propagating shocks are compared with those of bow shocks which form in front of dense obstacles in the jet, and specific applications to 0727 - 115 and BL Lacertae are considered. In the case of 0727 - 115, it is pointed out that the nonuniformity of the swing rate and the apparent oscillations of the degree of polarization could be a consequence of relativistic aberration.

Konigl, A.↗

Positive ion composition and derived particle heating in the lower auroral ionosphere

Two E11a rocket flights in salvo B (launched on November 16, 1980) and A2 (launched on November 30, 1980), which provide positive ion composition, total and partial ion density, and electron density in the altitude range 60-170 km above Kiruna under conditions of moderate and strong magnetic disturbance, are examined. It is shown that the ionization sources are predominantly precipitating electrons in salvo B and precipitating protons in salvo A2. Under winter-time auroral conditions the characteristics of the positive ion composition are large NO(+)/O2(+) density ratios, with maximum values of 20 at 118 km in salvo B and 100 at 100 km in salvo A2, respectively. The transition from NO(+) to proton hydrates is found at an altitude of 79 km in salvo B and 76 km in salvo A2. The calculated O(+) and N(+) densities are in good agreement with model calculations and from these calculations it is concluded that 28(+) is mainly N2(+) above 110 km in salvo B and above 105 km in salvo A2, and Si(+) below these altitudes. By altitude integration of the ion-electron pair production, the energy flux of precipitating particles is found to have values of 0.85 mW/sq m and 1.0 mW/sq m in salvoes B and A2, respectively.

Kopp, E.↗

Position-dependent effective masses in semiconductor theory. II

A compound semiconductor possessing a slowly varying position-dependent chemical composition is considered. An effective-mass equation governing the dynamics of electron (or hole) motion using the Kohn-Luttinger representation and canonical transformations is derived. It is shown that, as long as the variation in chemical composition may be treated as a perturbation, the effective masses become constant, position-independent quantities. The effective-mass equation derived here is identical to the effective-mass equation derived previously by von Roos (1983), using a Wannier representation.

Von Roos, O.↗

High dynamic global positioning system receiver

A Global Positioning System (GPS) receiver having a number of channels, receives an aggregate of pseudorange code time division modulated signals. The aggregate is converted to baseband and then to digital form for separate processing in the separate channels. A fast fourier transform processor computes the signal energy as a function of Doppler frequency for each correlation lag, and a range and frequency estimator computes estimates of pseudorange, and frequency. Raw estimates from all channels are used to estimate receiver position, velocity, clock offset and clock rate offset in a conventional navigation and control unit, and based on the unit that computes smoothed estimates for the next measurement interval.

Hurd, W. J.↗

Specification of a NAVSTAR Global Positioning System (GPS) receiver for a differential GPS ground system

One step towards the successful completion of a functional ground unit for the Differential Global Positioning System (DGPS) will be in choosing a currently available GPS receiver that will accurately measure the propagation times of the satellite signals and have the capability to be electrically interfaced with and controlled by a Digital Equipment Corporation (DEC) PDP-11/34A computer. The minimum requirements and characteristics of a NAVSTAR Global Positioning System (GPS) receiver are described. The specific technical specifications addressed include data accuracies and resolutions, receiver interface/external control, enclosure dimensions and mounting requirements, receiver operation, and environmental specifications.

Mccall, D. L.↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 8000 rpm (838 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗

Wavelength-division multiplexed digital optical position transducer

A novel concept for a digital optical position tranducer is presented. This compact and rugged device is electrically passive and requires only a dual-fiber optical link. Wavelength division of a broad-spectrum semiconductor light source is employed to multiplex the channels of a 10-bit digital position encoder. A preliminary design was evaluated and found to have a 10-dB on-off contrast ratio and a 12-dB insertion loss.

Fritsch, K.↗

Improving the absolute positioning accuracy of robot manipulators

The absolute positioning accuracy of robot manipulator can be increased substantially by updating the nominal link parameters in the control software. This paper presents a general method to estimate the link parameter errors for any serial link manipulator (i.e., n links, and any combination of revolute and prismatic joints). The parameters are estimated through a linear kinematic model which relates the link bias errors to the end-effector positioning error. Only end-effector measurements are required instead of individual link measurements to implement this method.

Hayati, S.↗

Optical identifications of radio sources with accurate positions using the United Kingdom Schmidt Telescope (UKST) IIIa-J plates

Several programs are making use of UKST Sky Survey plates to identify southern radio sources. The fine-grain modern plates and accurate radio positions give a much improved identification rate. It seems that it will very soon be possible to determine whether or not there is a quasar redshift cut-off at z of about 4. There is an urgent need for more accurate fundamental reference star positions in the South.

Savage, A.↗

Probing the magnetic field of radio pulsars - A reexamination of polarization position angle swings

A vacuum magnetic field is assumed in the present calculation of the polarization position angle as a function of pulse longitude and polarization-limiting radius in radio pulsars. The polarization-limiting radius is estimated on the basis of results of Cheng and Ruderman (1980) and Stinebring (1982). The average change in position angle is also calculated, and this is found to be consistent with observations studied by Narayan and Vivekanand (1983); an alternative interpretation of the data is given, however, which is further supported by the frequency dependence of polarization angle swing in the Crab pulsar.

Barnard, J. J.↗

Qualification Testing of General Electric 50 Ah Nickel-Cadmium Cells with New Separator and New Positive Plate Processing

Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

Morrow, G. W.↗

Stability characteristics of a supersonic boundary layer and their relation to the position of the laminar-turbulent transition point

By comparing the calculated results with experimental data, it is demonstrated that the position of the laminar-boundary transition point of a boundary layer can be estimated by using the e-exp-n method. The effect of the Mach number, pressure gradient, and heat transfer on the laminar-turbulent transition is discussed. It is found that under conditions of strong cooling, the effect of the pressure gradient on the position of the transition point is less pronounced than in the absence of heat transfer.

Lysenko, V. I.↗

A new linear quadratic optimal controller for the 34-meter high efficiency antenna position loop

The design of a new position loop controller for the 34-meter High Efficiency Deep Space antennas using linear quadratic (LQ) optimal control techniques is discussed. The LQ optimal control theory is reviewed, and model development and verification are discussed. Families of optimal gain vectors are generated by varying weight parameters. Performance specifications were used to select a final gain vector. Estimator dynamics were selected and the corresponding gain vectors were computed. Final estimator selection was based on position, commanded rate, and estimator error responses.

Nickerson, J. A.↗

Wavelength dependence of position angle in polarization standards

Eleven of the 15 stars on Serkowski's (1974) list of 'Standard Stars with Large Interstellar Polarization' were investigated to determine whether the orientation of the plane of their linear polarization showed any dependence on wavelength. Nine of the eleven stars exhibited a statistically significant wavelength dependence of position angle when measured with an accuracy of about 0.1 deg standard deviation. For the majority of these stars, the effect is caused primarily by intrinsic polarization. The calibration of polarimeter position angles in a celestial coordinate frame must evidently be done at the 0.1 deg level of accuracy by using only carefully selected standard stars or by using other astronomical or laboratory methods.

Dolan, J. F.↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 9000 rpm (938 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗

Radio-source positions from VLBI

Positions of 85 compact extragalactic radio sources and the Galactic object Beta Persei (Algol) have been determined in the J2000.0 coordinate system for analysis of VLBI observations made with the bandwidth-synthesis technique. Twenty-four of these sources were observed with the Mark I VLBI system in 37 sessions distributed between April 1972 and May 1978, and 82 of the sources were observed with the Mark III system in 85 sessions distributed between August 1979 and December 1982. Each session spanned at least 24 hr. Standard errors for the estimated positions on the sky of the about 10 sources frequently observed with the Mark I system are about 1 mas, except for the declinations of nearly equatorial sources, where these errors approach 5 mas. Corresponding uncertainties for the about 20 sources frequently observed with the Mark III system are 0.3 and 2 mas, respectively.

Ma, C.↗

Precision of vertical position estimates from very long baseline interferometry

It is found that the precision of VLBI measurements of vertical crustal motions is limited by errors in the modeling of the propagation delay through the earth's neutral atmosphere, and by errors in finding the orientation of a fixed crust coordinate system in the VLBI reference frame. The repeatability of baseline length measurements study indicates a vertical position precision of about 8 cm, averaged over 13 sites and 4.5 years of data, while the repeatability of vertical position estimates for a Richmond, FL site is found to yield a precision of about 7 cm for 42 observations made over an 11-month period. An overall precision of 8 cm for a 24-hour VLBI observing session is obtained, and the effects of earth orientation parameter errors is contingent on the distances between the VLBI sites.

Herring, T. A.↗