Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Just-in-Time Compilation and Link-Time Optimization for OpenMP Target Offloading

Following the mass adoption of external accelerators for high performance computing, the overall performance of many applications has become increasingly dependent on relatively small accelerated kernels. As static analysis is fundamentally limited by dynamic values and external definitions, standard ahead-of-time compilation is not always sufficient to achieve the best performance. Furthermore, many users looking to port an existing application to run on an external accelerator will not want to fundamentally restructure their programs. These and other problems can be addressed through both link-time optimization (LTO) and just-in-time (JIT) compilation, but until now had sparse and inconsistent support from the compiler. In this work, we present a new compilation method that enables device-side LTO as well as a transparent JIT compilation tool-chain for OpenMP target offloading. Our contributions include an entirely new device linking and embedding scheme to enable LTO as well as a novel JIT engine to efficiently optimize OpenMP offloading regions at run-time. We also introduce a persistent caching system to improve end-to-end runtime using the JIT engine and minimize kernel launching overheads. We measure the performance of our LTO and JIT implementation via several real-world scientific applications. With our optimizations we observe significant improvements through LTO on large applications as well as significant end-to-end execution time improvement using JIT.

Tian, Shilei↗

Ready for the Frontier: Preparing Applications for the World’s First Exascale System

Frontier, a supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), debuted atop the Top500 list of the world’s most powerful supercomputers in June 2022 as the very first computer to produce exascale performance. Making sure scientific applications are optimized on this architecture is the critical link necessary to translate the newly available computational power into scientific insight and solutions. To that goal, the OLCF developed the Center for Accelerated Application Readiness (CAAR) program to ensure that a suite of highly optimized applications is ready for scientific runs at the onset of production operations for Frontier. This paper describes our experience in porting and optimizing such suite of applications in the OLCF’s CAAR program.

Budiardja, Reuben↗

Developing Ultrahigh-Resolution E3SM Land Model for GPU Systems

Designing and refactoring complex scientific code, such as the E3SM land model (ELM), for new computing architectures is challenging. This paper presents design strategies and technical approaches to develop a data-oriented, GPU-ready ELM model using compiler directives (OpenACC/OpenMP). We first analyze the datatypes and processes in the original ELM code. Then we present design considerations for ultrahigh-resolution ELM (uELM) development for massive GPU systems. These techniques include the global data-oriented simulation workflow, domain partition, code porting and data copy, memory reduction, parallel loop restructure and flattening, and race condition detection. We implemented the first version of uELM using OpenACC targeting the NVidia GPUs in the Summit supercomputer at Oak Ridge National Laboratory. During the implementation, we developed a software tool (named SPEL) to facilitate code generation, verification, and performance tuning using these techniques. The first uELM implementation for Nvidia GPUs on Summit delivered promising results: 1) over 98% of the ELM code was automatically generated and tuned by scripts. Most ELM modules had better computational performances than the original ELM code for CPUs. The GPU-ready uELM is more scalable than the CPU code on fully-loaded Summit nodes. Example profiling results from several modules are also presented to illustrate the performance improvements and race condition detection. The lessons learned and toolkit developed in the study are also suitable for further uELM deployment using OpenMP on the first US exascale computer, Frontier, equipped with AMD CPUs and GPUs.

Schwartz, Peter↗

Making Uintah Performance Portable for Department of Energy Exascale Testbeds

To help ease ports to forthcoming Department of Energy (DOE) exascale systems, testbeds have been made available to select users. These testbeds are helpful for preparing codes to run on the same hardware and similar software as in their respective exascale systems. This paper describes how the Uintah Computational Framework, an open-source asynchronous many-task (AMT) runtime system, has been modified to be performance portable across the DOE Crusher, DOE Polaris, and DOE Sunspot testbeds in preparation for portable simulations across the exascale DOE Frontier and DOE Aurora systems. The Crusher, Polaris, and Sunspot testbeds feature the AMD MI250X, NVIDIA A100, and Intel PVC GPUs, respectively. This performance portability has been made possible by extending Uintah’s intermediate portability layer [18] to additionally support the Kokkos::HIP, Kokkos::OpenMPTarget, and Kokkos::SYCL back-ends. This paper also describes notable updates to Uintah’s support for Kokkos, which were required to make this extension possible. Results are shown for a challenging radiative heat transfer calculation, central to the University of Utah’s predictive boiler simulations. These results demonstrate single-source portability across AMD-, NVIDIA-, and Intel-based GPUs using various Kokkos back-ends.

Holmen, John↗

Computational Nuclear Physics and Post Hartree-Fock Methods

We present a computational approach to infinite nuclear matter employing Hartree-Fock theory, many-body perturbation theory and coupled cluster theory. These lectures are closely linked with those of chapters 9, 10 and 11 and serve as input for the correlation functions employed in Monte Carlo calculations in chapter 9, the in-medium similarity renormalization group theory of dense fermionic systems of chapter 10 and the Green's function approach in chapter 11. We provide extensive code examples and benchmark calculations, allowing thereby an eventual reader to start writing her/his own codes. We start with an object-oriented serial code and end with discussions on strategies for porting the code to present and planned high-performance computing facilities.

Lietz, Justin↗

A Performance Study of Quantum ESPRESSO’s PWscf Code on Multi-core and GPU Systems

We describe the porting of PWscf (Plane-Wave Self Consistent Field), a key component of the Quantum ESPRESSO open-source suite of codes for materials modeling, to GPU systems using CUDA Fortran. Kernel loop directives (CUF kernels) have been extensively used in order to have a single source code for both CPU and GPU implementations. The results of the GPU version have been carefully validated and the performance of the code on several GPU systems (both x86 and POWER8 based) has been compared with traditional Intel multi-core (CPU only) systems. This current GPU version can reduce the time-to-solution by an average factor of 2–3 running two different input cases widely used as benchmarks on small and large high performance computing systems.

CUDA Fortran↗

OpenMP 4.5 Validation and Verification Suite for Device Offload

OpenMP has been widely adopted for shared memory systems for over a decade. With the heterogeneity trend in architectures rapidly growing, the programming model needed to evolve such that applications could not only be ported to traditional CPUs but also to accelerators often acting as discrete or integrated devices to CPUs. To that end, OpenMP started to provide support for heterogeneous systems since 2013 when the version 4.0 of the specification was ratified. OpenMP 4.5 is being enhanced to cover major requirements of Exascale Computing Project (ECP) applications. As a result it is time-critical to ensure that the implementations of the 4.5 features are correct and conforming to the specification. This paper focuses on building a Validation and Verification testsuite that will test and present results for several offloading features implemented in compilers such as Clang, IBM XL C/C++, CCE, and GCC. We have results for our testsuite on TITAN, Summitdev and Summit at the Oak Ridge National Lab. We will highlight some of the ambiguities we encountered in the process of validating and verifying feature implementations. We also make the testsuite available for anyone to use and will walk the readers through the infrastructure and the workflow of the testsuite. A website has been built to capture our efforts narrated in this paper https://crpl.cis.udel.edu/ompvvsollve.

99 GENERAL AND MISCELLANEOUS↗

A simple, pipelined algorithm for large, irregular all-gather problems.

We present and evaluate a new, simple, pipelined algorithm for large, irregular all-gather problems, useful for the implementation of the MPI-Allgatherv collective operation of MPI. The algorithm can be viewed as an adaptation of a linear ring algorithm for regular all-gather problems for single-ported, clustered multiprocessors to the irregular problem. Compared to the standard ring algorithm, whose performance is dominated by the largest data size broadcast by a process (times the number of processes), the performance of the new algorithm depends only on the total amount of data over all processes. The new algorithm has been implemented within different MPI libraries. Benchmark results on NEC SX-8, Linux clusters with InfiniBand and Gigabit Ethernet, Blue Gene/P, and SiCortex systems show huge performance gains in accordance with the expected behavior.

99 GENERAL AND MISCELLANEOUS↗

Strategies for obtaining long constant-pressure test times in shock tubes

Several techniques have been developed for obtaining long, constant-pressure test times in reflected shock wave experiments in a shock tube, including the use of driver inserts, driver gas tailoring, helium gas diaphragm interfaces, driver extensions, and staged driver gas filling. Here, we detail these techniques, including discussion on the most recent strategy, staged driver gas filling. Experiments indicate that this staged filling strategy increases available test time by roughly 20 % relative to single-stage filling of tailored driver gas mixtures, while simultaneously reducing the helium required per shock by up to 85 %. This filling scheme involves firstly mixing a tailored helium–nitrogen mixture in the driver section as in conventional driver filling and, secondly, backfilling a low-speed-of-sound gas such as nitrogen or carbon dioxide from a port close to the end cap of the driver section. Using this staged driver gas filling, in addition to the other techniques listed above, post-reflected shock test times of up to 0.102 s (102 ms) at 524 K and 1.6 atm have been obtained. Spectroscopically based temperature measurements in non-reactive mixtures have confirmed that temperature and pressure conditions remain constant throughout the length of these long test duration trials. Finally, these strategies have been used to measure low-temperature n-heptane ignition delay times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scheme for Creating a Subcutaneous Tunnel to Place an Indwelling Implantable Central Venous Access System in the Forearm

We report a method that we have devised in which a secure subcutaneous tunnel is prepared during the placement of an indwelling central venous reservoir in the forearm. Subjects included 69 cases in which a procedure for implanting an indwelling reservoir in the forearm was performed between June 2006 and May 2007. For the subcutaneous tunnel, a 22-G Cathelin needle was advanced from the puncture site, turning toward the subcutaneous pocket side to the deep subcutaneous area. A 14-G Surflo IV catheter was then advanced along the 22-G Cathelin needle from the subcutaneous pocket. With the tip of the 14-G Surflo IV catheter emerging above the skin at the puncture site, the inner needle of the 14-G Surflo IV catheter and the 22-G Cathelin needle were removed. The catheter was passed through the outer 14-G Surflo IV catheter to emerge on the subcutaneous pocket site, then the outer needle of the Surflo catheter was also removed, and a connection to the port was made to create the subcutaneous tunnel. In all 69 cases, the subcutaneous tunnel in the forearm of the nondominant arm was successfully created within a short period of time (100% success rate). No problems were observed due to slack in the catheter until removal of the sutures 1 week later and for 3 months after treatment. With this method, we believe that a subcutaneous tunnel can be prepared in which the contained catheter has minimal freedom of movement, and which minimizes any damage induced by slack in the catheter within the subcutaneous tunnel.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Feasibility Study on the Combination of Two Different Regional Treatment Approaches in Patients with Colorectal 'Liver-Only' Metastases: Hepatic Interstitial Brachytherapy Plus Regional Chemotherapy

The aim of this study was to evaluate the feasibility, safety, and efficacy of combined treatment with hepatic interstitial brachytherapy (HIB) and hepatic arterial infusion (HAI) of chemotherapy after interventional implantation of port catheter systems. Thirty-three patients with unresectable 'liver-only' metastases of colorectal cancer were treated with both HIB and HAI during the course of their disease. All 33 patients had recurrent disease and 27 had received previous chemotherapy. Of these, 15 received HAI first and were then consolidated with HIB, 9 started with HIB and were continued with HAI, and 9 received first HIB and subsequently HAI after hepatic disease progression. Patients were evaluated for treatment characteristics, side effects, and efficacy. Comparisons between treatment groups were also performed. The median tumor diameter of metastases treated with brachytherapy was 4.6 cm (range: 1-12 cm). The median minimal irradiation dose inside the tumor margin was 18 Gy administered to a mean of two metastases in 69 interventions. Minor (n = 4) and major (n = 3) complications occurred in 10% of interventions. WHO grade III adverse events of the regional chemotherapy were observed in seven patients; grade IV, in one patient. At a median follow-up of 28 months (range: 7-74 months), the median time to disease progression after first treatment was 10.5 months (range: 1-35 months). Of 138 metastases treated by brachytherapy, 16 local recurrences were seen (mean, 12.3 months; range, 3-45 months). No signs of hepatic failure were observed in any of our patients. In conclusion, combinations of two minimally invasive therapeutic methods are feasible, with acceptable complication rates, and provide promising results in colorectal cancer patients with unresectable hepatic metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters

Catheter coatings have the potential to decrease infection and thrombosis in patients with chronic dialysis catheters. We report our midterm experience with a heparin-coated dialysis catheter. This retrospective, case-control study was approved by our Institutional Review Board. A total of 88 tunneled dialysis catheters were inserted over a 13-month period via the internal jugular vein. Thirty-eight uncoated split-tip catheters and 50 heparin-coated catheters were inserted. Primary catheter patency was compared between the two groups using the log rank test, with infection and/or thrombosis considered as catheter failures. Dialysis parameters during the first and last dialysis sessions, including pump speed, actual blood flow, and arterial port pressures, were compared using unpaired t-tests. Primary patency of the uncoated catheters was 86.0 {+-} 6.5% at 30 days and 76.1 {+-} 8.9% at 90 days. Primary patency of heparin-coated catheters was 92.0 {+-} 6.2% at 30 days and 81.6 {+-} 8.0% at 90 days (p = 0.87, log rank test). Infection requiring catheter removal occurred in four patients with uncoated catheters and two patients with heparin-coated catheters (p = 0.23). Catheter thrombosis requiring catheter replacement or thrombolysis occurred in one patient with an uncoated catheter and two patients with heparin-coated catheters (p = 0.9). No differences in catheter function during hemodialysis were seen between the two groups. In conclusion, the heparin-coated catheter did not show a significantly longer patency compared to the uncoated catheter. The flow characteristics of this device were comparable to those of the conventional uncoated catheter. A demonstrable benefit of the heparin-coated catheter in randomized trials is needed before a recommendation for routine implementation can be made.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a Peripherally Inserted Central Catheter as a Conduit for Central Venous Access Across Thrombosed Great Veins

This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Application of a New Indwelling Catheter with a Side-Hole and Spirally Arranged Shape-Memory Alloy for Hepatic Arterial Infusion Chemotherapy

A new indwelling catheter, G-spiral (GSP), was developed for hepatic arterial infusion chemotherapy (HAIC) by way of an implanted catheter-port system (CPS). Here we evaluated its physical properties and the outcomes of its clinical use. The GSP vessel-fixing power and its ability to follow a guidewire were determined with a vascular in vitro model, and Student t test was used to determine statistical significance (P < 0.05). A retrospective analysis was performed to evaluate the technical success rate and to identify the clinical complications associated with radiologic CPS implantation with GSP in 65 patients with unresectable hepatic tumors. The mean vessel-fixing power of the GSP (14.4 g) significantly differed from that of a GSP with a cut shape-memory alloy (3.3 g). The mean resistance to following the guidewire displayed by the GSP (88.5 g) was significantly less than that for a 5F W-spiral (106.3 g) or 4F Cobra-type angiographic catheter (117.8 g). The CPS was placed successfully in 64 of 65 cases (98.5%). Hepatic artery occlusion was observed in one case. Occlusion, cracking, and infection of CPS were observed in one, two, and one case, respectively. The GSP is a highly useful indwelling catheter that can be used for HAIC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical response and microprocesses of reconsolidating crushed salt at elevated temperature

Design, analysis and performance assessment of potential salt repositories for heat-generating nuclear waste require knowledge of thermal, mechanical, and fluid transport properties of reconsolidating granular salt. So, to inform salt repository evaluations, we have undertaken an experimental program to determine Bulk and Young’s moduli and Poisson’s ratio of reconsolidated granular salt as a function of porosity and temperature and to establish the deformational processes by which the salt reconsolidates. Our tests were conducted at 100, 175, and 250 °C. In hydrostatic tests, confining pressure is increased to 20 MPa with periodic unload/reload loops to determine K. Volume strain increases with increasing temperature. In shear tests at 2.5 and 5 MPa confining pressure, after confining pressure is applied, the crushed salt is subjected to a differential stress, with periodic unload/reload loops to determine E and ν. At predetermined differential stress levels the stress is held constant and the salt consolidates. Displacement gages mounted on the samples show little lateral deformation until the samples reach a porosity of ~10 %. Interestingly, vapor is vented only for 250 °C tests and condenses at the vent port. It is hypothesized that the brine originates from fluid inclusions, which were made accessible by heating and intragranular deformational processes including decrepitation. Furthermore, identification and documentation of consolidation processes are inferred from optical and scanning electron microstructural observations. As a result, densification at low porosity is enhanced by water film on grain boundaries that enables solution-precipitation phenomena.

58 GEOSCIENCES↗

An Interaction-Free Quantum Measurement-Driven Engine

Recently highly-efficient quantum engines were devised by exploiting the stochastic energy changes induced by quantum measurement. Here we show that such an engine can be based on an interaction-free measurement, in which the meter seemingly does not interact with the measured object. We use a modified version of the Elitzur–Vaidman bomb tester, an interferometric setup able to detect the presence of a bomb triggered by a single photon without exploding it. In our case, a quantum bomb subject to a gravitational force is initially in a superposition of being inside and outside one of the interferometer arms. We show that the bomb can be lifted without blowing up. This occurs when a photon traversing the interferometer is detected at a port that is always dark when the bomb is located outside the arm. The required potential energy is provided by the photon (which plays the role of the meter) even though it was not absorbed by the bomb. A natural interpretation is that the photon traveled through the arm which does not contain the bomb—otherwise the bomb would have exploded—but it implies the surprising conclusion that the energy exchange occurred at a distance despite a local interaction Hamiltonian. We use the weak value formalism to support this interpretation and find evidence of contextuality. Regardless of interpretation, this interaction-free quantum measurement engine is able to lift the most sensitive bomb without setting it off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of the ITER Electron Cyclotron Heating and Current Drive System

We present that the electron cyclotron (EC) heating and current drive (H&CD) system developed for the ITER is made of 12 sets of high-voltage power supplies feeding 24 gyrotrons connected through 24 transmission lines (TL), to five launchers, four located in upper ports and one at the equatorial level. Nearly all procurements are in-kind, following general ITER philosophy, and will come from Europe, India, Japan, Russia and the USA. The full system is designed to couple to the plasma 20 MW among the 24 MW generated power, at the frequency of 170 GHz, for various physics applications such as plasma start-up, central H&CD and magnetohydrodynamic (MHD) activity control. The design takes present day technology and extends toward high-power continuous operation, which represents a large step forward as compared to the present state of the art. The ITER EC system will be a stepping stone to future EC systems for DEMO and beyond.The development of the EC system is facing significant challenges, which includes not only an advanced microwave system but also compliance with stringent requirements associated with nuclear safety as ITER became the first fusion device licensed as basic nuclear installations as of 9 November 2012. Finally, since the conceptual design of the EC system was established in 2007, the EC system has progressed to a preliminary design stage in 2012 and is now moving forward toward a final design.

42 ENGINEERING↗

Portable C++ Code that can Look and Feel Like Fortran Code with Yet Another Kernel Launcher (YAKL)

This paper introduces the Yet Another Kernel Launcher (YAKL) C++ portability library, which strives to enable user-level code with the look and feel of Fortran code. The intended audience includes both C++ developers and Fortran developers unfamiliar with C++. The C++ portability approach is briefly explained, YAKL’s main features are described, and code examples are given that demonstrate YAKL’s usage. YAKL fills a niche capability important particularly to scientific applications seeking to port Fortran code quickly to a portable C++ library. YAKL places heavy emphasis on simplicity, readability, and productivity with performance mainly emphasizing Graphics Processing Units (GPUs). Central to YAKL’s ability to allow Fortran-like user-level code are three features: (1) a multi-dimensional Array class that allows Fortran behavior; (2) a limited library of Fortran intrinsic functions; and (3) an efficient pool allocator that transparently enables cheap frequent allocations and deallocations of YAKL Arrays. While YAKL allows Fortran-style code, it also allows Arrays that exhibit C-like behavior as well, including row-major index ordering and lower bounds of “0”. YAKL currently supports CPUs, CPU threading, and Nvidia, AMD, and Intel GPUs.

97 MATHEMATICS AND COMPUTING↗