Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 - Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the APR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. To protect workers at Hanford Tank Farms, WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at the tank farms. The tests were conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs when workers are exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on a vapor slipstream from the Hanford AX tank farm exhauster. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing on AX exhauster slipstream vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

42 ENGINEERING↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hazard and Operability Study for the Ammonia Fuel Systems at the National Transportation Research Center

Oak Ridge National Laboratory’s (ORNL’s) Buildings and Transportation Science Division (BTSD) plans to operate research engines fueled by ammonia in two engine test cells at the National Transportation Research Center (NTRC). A scientific need has recently emerged to evaluate the suitability of liquid anhydrous ammonia as a low-lifecycle-carbon fuel source for difficult-to-electrify transportation sectors, including the marine sector. Therefore, BTSD plans to install an ammonia storage and delivery system to 2360 HVC engine research labs L125 (Cell 3) and L111 (Cell 7) capable of delivering 35 and 75 lb/h, respectively. These laboratories are specifically designed to allow for engine and fuels research and development, and they have existing safety systems for mitigating risks associated with toxics and flammables. Anhydrous ammonia is toxic and flammable, and the system will use relatively large quantities compared with standard gas bottles. Ammonia is one of the most widely produced chemicals in the world, and the hazards associated with toxicity and flammability are well understood. Ammonia storage for use in engine research at NTRC is anticipated to take the form of an ammonia tank with capacity of 1,000 water gallons; this quantity will remain below the threshold quantity of 10,000 lb (~2,000 gal) used both by the US Environmental Protection Agency for reporting under the Emergency Planning and Community Right to Know Act and for Risk Management Program requirements, and also by the US Occupational Safety and Health Administration for Process Safety Management requirements. ORNL’s Environmental Protection Services Division was also consulted to verify that the quantities of ammonia anticipated to be used would be in compliance with environmental regulations. The Environmental Protection Services Division staff confirmed that the anticipated quantities fall below ORNL’s permit thresholds. However, because of the hazards associated with anhydrous ammonia, the quantities to be used, and the limited experience with similar quantities of ammonia at ORNL, BTSD decided to perform a hazard and operability (HazOp) study on the ammonia storage and delivery system.

33 ADVANCED PROPULSION SYSTEMS↗

TA-03-0016 Ion Beam Facility D&D: Sphere of Influence [Slides]

TA-03-0016 Ion Beam Facility: This structure is 70 years old and has been vacant since 1994 and was excessed in 1999. The Ion Beam Facility (IBF) was built in 1953 to support essential post-World War II scientific research and houses LANL's original vertical and tandem Van de Graaff accelerators. The vertical Van de Graaff accelerator was built under the direction of Joseph McKibben from 1948 to 1952 and was used for applied nuclear physics experiments. The Ion Beam facility is considered by NNSA as one of its highest risk process contaminated facilities within the complex. Ion Beam is a radiological facility adjacent to the LANL Occupational Medicine Facility on the south side of TA-3, the most populated technical area at LANL. It poses an undesirable fire risk, especially given its close location to a rugged wooded canyon and difficulties in fighting a wildland fire in such a location. Demolition of this structure will provide a constructable site for critical mission radiological laboratory spaces.

99 GENERAL AND MISCELLANEOUS↗

Automatic Receptacle Controls: Evaluating the clarity of receptacle markings

Plug loads and the electric loads of devices plugged into receptacles in commercial buildings play a significant and growing role in commercial buildings. Because plug loads are portable and are often placed in the building by the occupants, they are a challenging load to manage. This report summarizes an analysis of commercially available automatic receptacle controls (ARCs). As a part of this study, generic versions of ARCs were presented to a general user audience via an online survey, wherein survey respondents indicated which markings more clearly indicated that the receptacle was controlled. A total of 210 responses were collected and included in the analysis presented in this report. The results showed that receptacles with high-contrast markings were consistently clearer and more evident to the users than low-contrast markings. The survey responses also revealed that receptacles with a border drawn around each controlled receptacle were clearer and distinct to the users compared to other markings. These results led to the conclusion that for energy saving technology to be effective, consistent and easy to understand markings are necessary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformative Manufacturing of Adaptive Wire Feedstocks with Atomic Layer Deposition of Nb 2 O 5 onto Depleted Uranium [Slides]

Project Motivation: Uranium corrosion susceptible and highly catalytic; Exposure thickens oxide impacting material performance. This worsens with time; Sigma is uniquely positioned to tackle R&D challenges with Uranium processing. Possible Solutions: 1) Make new material for each weld. Occupational exposure, difficult to align resources ; 2) Coatings? Coating adds foreign material: can this be minimized?

36 MATERIALS SCIENCE↗

Development of Large Area µRWELL Detectors for CLAS12 High Luminosity Upgrade at Jefferson Lab

The high-luminosity upgrade of the CEBAF Large Acceptance Spectrometer (CLAS12) will significantly enhance the physics reach of experiments in Hall B at JLab. However, at the current luminosity of L = 1 × 1035 cm-2 s-1, the reconstruction efficiency of charged particles in the forward region of the CEBAF Large Acceptance Spectrometer (CLAS12) is at the level of 85% and limited in part by the drift chambers inability to handle high occupancy, in the first tracking region (DC-R1) of the Forward Detector. The reconstruction efficiency is expected to drop even lower at higher luminosities with the current tracking technology. Various options under consideration to achieve the desired performance at a higher luminosity of L = 2 × 1035 cm-2 s-1 include the addition of fast tracking layers to complement DC-R1 or the replacement of DC-R1 with a different tracking detector technology altogether. In either case, a novel generation of compact, simple and robust Micro-Pattern Gaseous Detector (MPGD) known as the Resistive Micro-Well detector (µRWELL) is the ideal candidate to satisfy the requirements in terms of timing O (10 ns) and position O (100 µm) resolutions. A large µRWELL prototype, combined with a two-dimensional U-V strip readout layer based on the novel concept of capacitive-sharing approach has been developed as a proof of principle for fast tracking capabilities in the forward region of CLAS12 high-luminosity upgrade. In this talk, we will present the technical aspects of the design choices of the large µRWELL prototype under development and report on the detector assembly process and preliminary performance characteristic tests. We will also discuss the plans for the test and characterization of the prototype in beam during spring 2023 CEBAF run. Finally, we will report on ongoing R&D efforts on small prototypes with the goal to improve rate capability, spatial resolution performance and minimize material thickness.

Gnanvo, Kondo↗