Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Ultrafast infrared plasmon switching in aligned carbon-nanotube optical resonators

Reconfigurable plasmonic materials are crucial components in active photonic devices for optical communication, signal processing, and sensing applications. Certain candidates including transparent conducting oxides, small-bandgap semiconductors (i.e. Ge, InSb), and conducting polymers can exhibit switchable free carrier concentrations triggered by optical, electrical or thermal excitations. Here, we show that aligned films of single-walled carbon nanotubes (SWCNTs) can serve as all-optically tunable plasmonic material in the mid-infrared range, thereby adding them to the library of switchable plasmonic materials. Interband optical pumping with femtosecond laser pulses results in the photoexcitation of free charge carriers, which transiently blueshifts the plasmon resonances of patterned, periodic SWCNT nano-resonators spanning the mid-infrared spectral range from 1700 to 2700 cm -1 . Furthermore. the ultrafast plasmon modulation exhibits a nearly single-picosecond decay time, attributed to interband carrier relaxation and inter-tube charge transfer. Given that aligned films of SWCNTs have high thermal stability, excellent photostability, epsilon-near-zero property, and extremely large optical anisotropy, their dynamic tunability represents a promising pathway towards active optical devices in the technologically important mid-infrared range.

single-walled carbon nanotubes↗

Selective electron-phonon coupling strength from nonequilibrium optical spectroscopy: The case of MgB 2

The coupling between quasiparticles and bosonic excitations rules the energy transfer pathways in condensed matter systems. The possibility of inferring the strength of specific coupling channels from their characteristic timescales measured in nonequilibrium experiments is still an open question. Here, in this study, we investigate MgB 2 , in which conventional superconductivity at temperatures as high as 39 K is mediated by the strong coupling between the conduction electrons and the 𝐸 2⁢𝑔 phonon mode. By means of broadband time-resolved optical spectroscopy, we show that this selective electron-phonon coupling dictates the nonequilibrium optical response of MgB 2 at early times (<100 fs) after photoexcitation. Furthermore, based on an effective temperature model analysis, we estimate its contribution to the total electron-boson coupling function extracted from complementary equilibrium spectroscopy approaches, namely, optical reflectivity and angle-resolved photoemission spectroscopy. The coupling strength with the 𝐸 2⁢𝑔 phonon modes is thus estimated to be 𝜆 ≃ 0.56, which is approximately half of the total coupling constant, in agreement with 𝑎𝑏 initio calculations from the literature. As a benchmark, broadband time-resolved optical spectroscopy is performed also on the isostructural and nonsuperconducting compound AlB 2 , showing that the nonequilibrium optical response relaxes on a slower timescale due to the lack of strongly coupled phonon modes. Our findings demonstrate the possibility to resolve and quantify selective electron-phonon coupling from nonequilibrium optical spectroscopy.

Mor, Selene [Università Cattolica del Sacro Cuore,↗

Quantum interference between the optical Stark effect and resonant harmonic generation in WS 2

An applied field can modulate optical signals by resonance shifting via the Stark effect. The optical Stark effect uses ultrafast light in the transparency region of a material to shift resonances with speeds limited by the pulse duration or system coherence. In this Rapid Communication, we investigate the optical Stark effect in resonant optical harmonic generation using the A exciton transition of WS 2 . Multidimensional pump-harmonic-probe measurements, in which the probe is second- or third-harmonic emission, reveal not only large Stark shifts that are commensurate with the large optical susceptibilities common to WS 2 excitons, but also behaviors more complex than simple optical Stark effect treatments predict. We show how another manifestation of the Stark effect, brought forth by coherent photon exchange between the pump and harmonic generation fundamental fields, can strongly enhance or suppress harmonic generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical phonon dominated heat transport: A first-principles thermal conductivity study of BaSn 2

Acoustic phonons with long mean free paths have long been believed to control the lattice thermal conductivity κ L in solids dominantly. In this study, however, we demonstrate an optical phonon dominated κ L in BaSnS 2 . By solving the Peierls-Boltzmann transport equation, we predict a low diagonal lattice thermal conductivity κ L (D) of 0.34 W m -1 K -1 at 850 K, which is less than half the κ L (D) of SnS at the same temperature. Further calculations following the Allen-Feldman model suggest the additional off-diagonal lattice thermal conductivity κ L (OD) contributed by wavelike tunneling phonons. The κ L (OD) becomes pronounced at the high temperature ( 0.17 W m -1 K -1 at 850 K) and leads to a deviation of the temperature dependence of κ L from T -1 to T -0.76 , suggesting the potential lattice anharmonicity in BaSnS 2 . Further analyses indicate BaSnS 2 has over 68% of κ L contributed by optical phonons. We show this uncommon optical phonon dominated κ L is due to the relatively high group velocities of optical phonons in BaSnS 2 . The phonon mode visualization suggests these relatively high-velocity optical phonons correspond to the antiphase vibrations in BaSnS 2 monolayers, which is originated from the unique permutation of SnS 3 tetrahedra. Finally, by investigating the mode-resolved group velocity, relaxation time, and Grüneisen parameter, we attribute the intrinsic low κ L of BaSnS 2 to the soft lattice and the relatively high lattice anharmonicity induced by the Ba-S weak bonding and Sn(II) lone-pair electrons. Our study explicitly analyzes the microscopic mechanism of optical phonon dominated heat transport in BaSnS 2 and suggests it worthy of further experimental studies as an intrinsic low-κ L material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of infrared refractive indices of organic and organophosphorous compounds for optical modeling

The complex optical refractive index contains the optical constants, n($\tilde{u}$)and k($\tilde{u}$), which correspond to the dispersion and absorption of light within a medium, respectively. By obtaining the optical constants one can in principle model most optical phenomena in media and at interfaces including reflection, refraction and dispersion. We have developed improved protocols based on the use of multiple path lengths to determine the optical constants for dozens of liquids, including organic and organophosphorous compounds. Detailed description of the protocols to determine the infrared indices will be presented, along with preliminary results using the constants with their applications to optical modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE{sup Registered-Sign} radiochromic plastic

Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE{sup Registered-Sign} with optical-CT readout. Methods: Ge-doped SiO{sub 2} fibers with 6 {mu}m active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 {mu}m active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE{sup Registered-Sign }, 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE{sup Registered-Sign }, and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE{sup Registered-Sign }. Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE{sup Registered-Sign} gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. Conclusions: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE{sup Registered-Sign} with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical delay encoding for fast timing and detector signal multiplexing in PET

Purpose: The large number of detector channels in modern positron emission tomography (PET) scanners poses a challenge in terms of readout electronics complexity. Multiplexing schemes are typically implemented to reduce the number of physical readout channels, but often result in performance degradation. Novel methods of multiplexing in PET must be developed to avoid this data degradation. The preservation of fast timing information is especially important for time-of-flight PET. Methods: A new multiplexing scheme based on encoding detector interaction events with a series of extremely fast overlapping optical pulses with precise delays is demonstrated in this work. Encoding events in this way potentially allows many detector channels to be simultaneously encoded onto a single optical fiber that is then read out by a single digitizer. A two channel silicon photomultiplier-based prototype utilizing this optical delay encoding technique along with dual threshold time-over-threshold is demonstrated. Results: The optical encoding and multiplexing prototype achieves a coincidence time resolution of 160 ps full width at half maximum (FWHM) and an energy resolution of 13.1% FWHM at 511 keV with 3 × 3 × 5 mm{sup 3} LYSO crystals. All interaction information for both detectors, including timing, energy, and channel identification, is encoded onto a single optical fiber with little degradation. Conclusions: Optical delay encoding and multiplexing technology could lead to time-of-flight PET scanners with fewer readout channels and simplified data acquisition systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-EF-BRA-01: A Dual-Use Optical Tomography System for Small Animal Radiation Research Platform (SARRP)

Purpose: We develop a novel dual-use configuration for a tri-modality, CBCT/bioluminescence tomography(BLT)/fluorescence tomography(FT), imaging system with the SARRP that can function as a standalone system for longitudinal imaging research and on-board the SARRP to guide irradiation. BLT provides radiation guidance for soft tissue target, while FT offers functional information allowing mechanistic investigations. Methods: The optical assembly includes CCD camera, lens, filter wheel, 3-way mirrors, scanning fiber system and light-tight enclosure. The rotating mirror system directs the optical signal from the animal surface to the camera at multiple projection over 180 degree. The fiber-laser system serves as the external light source for the FT application. Multiple filters are used for multispectral imaging to enhance localization accuracy using BLT. SARRP CBCT provides anatomical information and geometric mesh for BLT/FT reconstruction. To facilitate dual use, the 3-way mirror system is cantilevered in front of the camera. The entire optical assembly is driven by a 1D linear stage to dock onto an independent mouse support bed for standalone application. After completion of on-board optical imaging, the system is retracted from the SARRP to allow irradiation of the mouse. Results: A tissue-simulating phantom and a mouse model with a luminescence light source are used to demonstrate the function of the dual-use optical system. Feasibility data have been obtained based on a manual-docking prototype. The center of mass of light source determined in living mouse with on-board BLT is within 1±0.2mm of that with CBCT. The performance of the motorized system is expected to be the same and will be presented. Conclusion: We anticipate the motorized dual use system provide significant efficiency gain over our manual docking and off-line system. By also supporting off-line longitudinal studies independent of the SARRP, the dual-use system is a highly efficient and cost-effective platform to facilitate optical imaging for pre-clinical radiation research. The work is supported by NIH R01CA158100 and Xstrahl Ltd. Drs. John Wong and Iulian Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University. John Wong also has a consultant agreement with Xstrahl Ltd.

60 APPLIED LIFE SCIENCES↗

Effect of Oxygen Flow Rate on Structural, Electrical and Optical Properties of Zinc Aluminum Oxide Thin Films Deposited by DC Magnetron Sputtering

Zinc Aluminum Oxide thin films were deposited on glass substrates by reactive DC magnetron sputtering method by varying oxygen flow rates from 1 to 4 sccm. Glancing angle X-ray diffraction patterns ofzinc aluminum oxide thin films exhibits (0 0 2) peak with c-plane preferentially oriented parallel to the substrate. The surface morphology and elemental analysis of the films was observed by field emission scanning electron microscopy attached with energy dispersive X-ray analysis spectroscopy. An average optical transmittance of 83–90% is obtained for the films deposited at various oxygen flow rates. The optical band gap of the films increases from 3.41 to 3.53 eV with the increase of oxygen flow rate due to Burstein–Moss effect. The optical dispersion parameters such as dispersion energy (E{sub d}), oscillator energy (E{sub o}) and static refractive index (n{sub o}) were determined using the Wemple-DiDomenico (W-D) single oscillator model. The nonlinear optical parameters such as optical susceptibility (χ{sup (1)}), third order nonlinear optical susceptibility (χ{sup (3)}) and nonlinear refractive index (n{sub 2}) were also determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chapter 3: Solar Optics and Principles

Solar irradiation originating from a finite-sized sun disc, as well as its various interactions with the atmosphere and reflective elements, results in the distribution of concentrated light at the receiver. The study of these interactions and the computation of the resulting flux distribution constitute the field of CSP optics. CSP optics is subdivided into two categories, namely, path-independent optics and geometric optics. This chapter deals primarily with the technology agnostic path-independent optics and attempts to convey some fundamental principles and to guide researchers. The path-independent optics introduced here includes sun shapes, the impact of surface microscopic and macroscopic structure, and atmospheric attenuation.

concentrating solar power↗

Particle damage sources for fused silica optics and their mitigation on high energy laser systems

High energy laser systems are ultimately limited by laser-induced damage to their critical components. This is especially true of damage to critical fused silica optics, which grows rapidly upon exposure to additional laser pulses. Much progress has been made in eliminating damage precursors in as-processed fused silica optics (the advanced mitigation process, AMP3), and very high damage resistance has been demonstrated in laboratory studies. However, the full potential of these improvements has not yet been realized in actual laser systems. In this work, we explore the importance of additional damage sources–in particular, particle contamination–for fused silica optics fielded in a high-performance laser environment, the National Ignition Facility (NIF) laser system. We demonstrate that the most dangerous sources of particle contamination in a system-level environment are laser-driven particle sources. In the specific case of the NIF laser, we have identified the two important particle sources which account for nearly all the damage observed on AMP3 optics during full laser operation and present mitigations for these particle sources. Finally, with the elimination of these laser-driven particle sources, we demonstrate essentially damage free operation of AMP3 fused silica for ten large optics (a total of 12,000 cm 2 of beam area) for shots from 8.6 J/cm 2 to 9.5 J/cm 2 of 351 nm light (3 ns Gaussian pulse shapes). Potentially many other pulsed high energy laser systems have similar particle sources, and given the insight provided by this study, their identification and elimination should be possible. The mitigations demonstrated here are currently being employed for all large UV silica optics on the National Ignition Facility

36 MATERIALS SCIENCE↗

Molecular and Cellular Characterization of a Zebrafish Optic Pathway Tumor Line Implicates Glia-Derived Progenitors in Tumorigenesis

In this study we describe the molecular and cellular characterization of a zebrafish mutant that develops tumors in the optic pathway. Heterozygous Tg(flk1:RFP)is18 transgenic adults develop tumors of the retina, optic nerve and optic tract. Molecular and genetic mapping demonstrate the tumor phenotype is linked to a high copy number transgene array integrated in the lincRNA gene lincRNAis18/ Zv9_00007276 on chromosome 3. TALENs were used to isolate a 147kb deletion allele that removes exons 2–5 of the lincRNAis18 gene. Deletion allele homozygotes are viable and do not develop tumors, indicating loss of function of the lincRNAis18 locus is not the trigger for tumor onset. Optic pathway tumors in the Tg(flk1:RFP)is18 mutant occur with a penetrance of 80–100% by 1 year of age. The retinal tumors are highly vascularized and composed of rosettes of various sizes embedded in a fibrous matrix. Immunohistochemical analysis showed increased expression of the glial markers GFAP and BLBP throughout retinal tumors and in dysplastic optic nerve. We performed transcriptome analysis of pre-tumorous retina and retinal tumor tissue and found changes in gene expression signatures of radial glia and astrocytes (slc1a3), activated glia (atf3, blbp, apoeb), proliferating neural progenitors (foxd3, nestin, cdh2, her9/hes1), and glioma markers (S100b, vim). The transcriptome also revealed activation of cAMP, Stat3 and Wnt signal transduction pathways. qRT-PCR confirmed .10-fold overexpression of the Wnt pathway components hbegfa, ascl1a, and insm1a. Together the data indicate Mu¨ ller glia and/or astrocyte-derived progenitors could contribute to the zebrafish Tg(flk1:RFP)is18 optic pathway tumors.

59 BASIC BIOLOGICAL SCIENCES↗

Accuracy optimized neural networks do not effectively model optic flow tuning in brain area MSTd

Accuracy-optimized convolutional neural networks (CNNs) have emerged as highly effective models at predicting neural responses in brain areas along the primate ventral stream, but it is largely unknown whether they effectively model neurons in the complementary primate dorsal stream. We explored how well CNNs model the optic flow tuning properties of neurons in dorsal area MSTd and we compared our results with the Non-Negative Matrix Factorization (NNMF) model, which successfully models many tuning properties of MSTd neurons. To better understand the role of computational properties in the NNMF model that give rise to optic flow tuning that resembles that of MSTd neurons, we created additional CNN model variants that implement key NNMF constraints – non-negative weights and sparse coding of optic flow. While the CNNs and NNMF models both accurately estimate the observer's self-motion from purely translational or rotational optic flow, NNMF and the CNNs with nonnegative weights yield substantially less accurate estimates than the other CNNs when tested on more complex optic flow that combines observer translation and rotation. Despite its poor accuracy, NNMF gives rise to tuning properties that align more closely with those observed in primate MSTd than any of the accuracy-optimized CNNs. This work offers a step toward a deeper understanding of the computational properties and constraints that describe the optic flow tuning of primate area MSTd.

60 APPLIED LIFE SCIENCES↗

Prompt Detection of Fast Optical Bursts with the Vera C. Rubin Observatory

Abstract The transient optical sky has remained largely unexplored on very short timescales. While there have been some experiments searching for optical transients from minutes to years, none have had the capability to distinguish millisecond fast optical bursts (FOBs). Such very fast transients could be the optical counterparts of fast radio bursts, the prompt emission from γ -ray bursts, or other previously unknown phenomena. Here, we investigate a novel approach to the serendipitous detection of FOBs, which relies on searching for anomalous spatial images. In particular, due to their short duration, the seeing-distorted images of FOBs should look characteristically different than those of steady sources in a standard optical exposure of finite duration. We apply this idea to simulated observations with the Vera C. Rubin Observatory, produced by tracing individual photons through a turbulent atmosphere, and down through the optics and camera of the Rubin telescope. We compare these simulated images to steady-source star simulations in 15 s integrations, the nominal Rubin exposure time. We report the classification accuracy results of a neural network classifier for distinguishing FOBs from steady sources. From this classifier, we derive constraints in duration–intensity parameter space for unambiguously identifying FOBs in Rubin observations. We conclude with estimates of the total number of detections of FOB counterparts to FRBs expected during the 10 yr Rubin Legacy Survey of Space and Time.

79 ASTRONOMY AND ASTROPHYSICS↗

Distributed optical fibre sensing in physical oceanography: emergence and future prospects

Distributed optical fibre sensing (DOFS) is a technology that enables continuous, real-time measurements of a range of environmental parameters along the length of a fibre optic cable. In this article, we review the recently emerged applications of DOFS techniques in physical oceanography and offer a perspective on the technology's potential for future growth within the field. The introduction of DOFS to physical oceanography is contextualised with a brief history of the technology, which spun off primarily from the use of seafloor-laid optical fibres for telecommunications purposes. The key components and underpinning physics of a DOFS system are outlined and, on their basis, the suite of variables that are observable with DOFS are discussed. The implementation factors of DOFS, which include trade-offs between measurement accuracy and spatio-temporal resolutions and ranges, are also examined. The physical oceanographic applications of DOFS to date are then illustrated with case examples of four distinct DOFS techniques: distributed temperature sensing (DTS), which can provide ocean temperature observations; distributed static strain sensing (DSS) and distributed acoustic sensing (DAS), which are sensitive to temperature, cable strain and strain-associated variables, such as pressure and ocean velocity; and ultra-long-range observations of ocean currents with optical interferometry. The forthcoming prospects of DOFS in physical oceanography are considered, and are proposed to include new fibre optic-based approaches to sense ocean salinity and measure through the water column. We conclude with reflections on the future role of DOFS within the Global Ocean Observing System, and highlight the opportunities provided by the existing world-wide network of seafloor-laid optical fibres.

Naveira Garabato, Alberto C. [Univ. of Southampton↗

Terrestrial Planet Finder Coronagraph Optical Modeling

The Terrestrial Planet Finder Coronagraph will rely heavily on modeling and analysis throughout its mission lifecycle. Optical modeling is especially important, since the tolerances on the optics as well as scattered light suppression are critical for the mission's success. The high contrast imaging necessary to observe a planet orbiting a distant star requires new and innovative technologies to be developed and tested, and detailed optical modeling provides predictions for evaluating design decisions. It also provides a means to develop and test algorithms designed to actively suppress scattered light via deformable mirrors and other techniques. The optical models are used in conjunction with structural and thermal models to create fully integrated optical/structural/thermal models that are used to evaluate dynamic effects of disturbances on the overall performance of the coronagraph. The optical models we have developed have been verified on the High Contrast Imaging Testbed. Results of the optical modeling verification and the methods used to perform full three-dimensional near-field diffraction analysis are presented.

space telescopes↗

Differential Deposition for Surface Figure Corrections in Grazing Incidence X-Ray Optics

Differential deposition corrects the low- and mid- spatial-frequency deviations in the axial figure of Wolter-type grazing incidence X-ray optics. Figure deviations is one of the major contributors to the achievable angular resolution. Minimizing figure errors can significantly improve the imaging quality of X-ray optics. Material of varying thickness is selectively deposited, using DC magnetron sputtering, along the length of optic to minimize figure deviations. Custom vacuum chambers are built that can incorporate full-shell and segmented Xray optics. Metrology data of preliminary corrections on a single meridian of full-shell x-ray optics show an improvement of mid-spatial frequencies from 6.7 to 1.8 arc secs HPD. Efforts are in progress to correct a full-shell and segmented optics and to verify angular-resolution improvement with X-ray testing.

X-Ray Optics↗

Simultaneous Water Vapor and Dry Air Optical Path Length Measurements and Compensation with the Large Binocular Telescope Interferometer

The Large Binocular Telescope Interferometer uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI/MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller uses a near-infrared camera to measure the optical path length variations between the two AO-corrected apertures and provide high-angular resolution observations for all its science channels (1.5-13 microns). There is however a wavelength dependent component to the atmospheric turbulence, which can introduce optical path length errors when observing at a wavelength different from that of the fringe sensing camera. Water vapor in particular is highly dispersive and its effect must be taken into account for high-precision infrared interferometric observations as described previously for VLTI MIDI or the Keck Interferometer Nuller. In this paper, we describe the new sensing approach that has been developed at the LBT to measure and monitor the optical path length fluctuations due to dry air and water vapor separately. After reviewing the current performance of the system for dry air seeing compensation, we present simultaneous H-, K-, and N-band observations that illustrate the feasibility of our feed forward approach to stabilize the path length fluctuations seen by the LBTI nuller.