Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Using Cross-Section Uncertainty Data to Estimate Biases

Ideally, computational method validation is performed by modeling critical experiments that are very similar, neutronically, to the model used in the safety analysis. Similar, in this context, means that the neutron multiplication factors (k eff ) of the safety analysis model and critical experiment model are affected in the same way to the same degree by variations (or errors) in the same nuclear data. Where similarity is demonstrated, the computational bias calculated using the critical experiment model results is 'applicable' to the safety analysis model. Unfortunately, criticality safety analysts occasionally find that the safety analysis models include some feature or material for which adequately similar well-defined critical experiments do not exist to support validation. For example, the analyst may want to take credit for the presence of fission products in spent nuclear fuel. In such cases, analysts sometimes rely on 'expert judgment' to assign an additional administrative margin to compensate for the validation weakness or to conclude that the impact on the calculated bias and bias uncertainty is negligible. Due to advances in computer programs and the evolution of cross-section uncertainty data, analysts can use the sensitivity and uncertainty analyses tools implemented in the SCALE TSUNAMI codes to estimate the potential impact on the application-specific bias and bias uncertainty resulting from nuclides that are under-represented or not present in the critical experiments. This paper discusses the method, computer codes, and data used to estimate the potential contribution toward the computational bias of individual nuclides. The results from application of the method to fission products in a burnup credit model are presented.

97 MATHEMATICS AND COMPUTING↗

Version 2.0.0 of ACE Tables Header Format

The ACE (A Compact ENDF) data format has been around for several decades. The ACE table format is a compact version of the Evaluated Nuclear Data File (ENDF) format. ACE tables contain data that are used in continuous-energy calculations such as those performed by MCNP.

Nuclear Physics & Radiation Physics(73)↗

NJOY2016

NJOY2016 is used to convert evaluations in the Evaluated Nuclear Data Files (ENDF) format into forms useful for practical applications such as fission and fusion reactor analysis, criticality safety, radiation shielding, nuclear waste management, nuclear medicine procedures, and more. It begins with the generation of pointwise libraries, including reaction and resonance reconstruction, Doppler broadening, radiation heating and damage, thermal scattering data, unresolved resonance data, and gas production. It reviews the production of libraries for the continuous-energy Monte Carlo code MCNP, multigroup neutron, photon, and particle cross sections and matrices, and photon interaction data. Uncertainty information for ENDF data is processed, including the capability for calculating covariances of resonance data, angular distributions, energy distributions, and radioactive nuclide production. NJOY can prepare and process thermal scattering data evaluations into application libraries. It can also plot cross sections, angular distributions and secondary emission spectra.

Kahler III, A. C. (Skip)↗

NJOY2016

NJOY2016 is used to convert evaluations in the Evaluated Nuclear Data Files (ENDF) format into forms useful for practical applications such as fission and fusion reactor analysis, criticality safety, radiation shielding, nuclear waste management, nuclear medicine procedures, and more. It begins with the generation of pointwise libraries, including reaction and resonance reconstruction, Doppler broadening, radiation heating and damage, thermal scattering data, unresolved resonance data, and gas production. It reviews the production of libraries for the continuous-energy Monte Carlo code MCNP, multigroup neutron, photon, and particle cross sections and matrices, and photon interaction data. Uncertainty information for ENDF data is processed, including the capability for calculating covariances of resonance data, angular distributions, energy distributions, and radioactive nuclide production. NJOY can prepare and process thermal scattering data evaluations into application libraries. It can also plot cross sections, angular distributions and secondary emission spectra.

Kahler III, A. C. (Skip)↗

Angular Correlation Date Measurements with the GeRMAC system

Advanced modeling and simulation efforts have improved at Idaho National Laboratory in recent years with a solid foundation of experimental results. Current computational methods represent significant modeling capabilities but are limited by the accuracy and availability of nuclear data. The creation of pre- and post-processing software tools to address these limitations is fundamental to the improvement of nuclear science modeling capacities. One aspect of predictive modeling tools deals with gamma-rays emitted from radionuclides, including fissile or fissionable material, fission products, or activation products, produced in reactor experiments or other neutron environments. The resulting radionuclides decay in unique ways, providing complications upon measurement as a result of random and cascade, or true, coincidence summing. These effects are not easily quantified during modeling efforts of gamma-ray source terms., The germanium rotational measurements for angular correlation (GeRMAC) system was built to quantify the relative angles for gamma rays emitted by radionuclides of interest to investigate true coincidence, or cascade, summing as well as the nuclear energy levels of decay schemes of interest. Proof of concept studies utilize a series of laboratory check sources to provide validity, and it will soon be used to perform the same measurements for fission products of interest. The resulting data can be used to implement into a Monte Carlo code, such as Geant4, to provide more precise gamma-ray source terms following irradiations of materials.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission neutron activations of stainless steel and its corresponding elemental components

Characterizing neutron activation of stainless steel is a critical task for many applications, and yet little activation data is available for this alloy. To address the need, a series of neutron activation experiments have been performed using the Flattop critical assembly at the National Criticality Experiments Research Center. Several experimental conditions were probed for complete understanding of the neutron environment, including foil composition and position within the assembly. The experimental results reported here will aid in the production of stainless steel benchmarks for a range of nuclear data applications including those used in nuclear forensics analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Magnetic Microcalorimeter Gamma Detectors with Ultra-High Energy Resolution. Final Report

The goal of this project was to build a commercially viable metallic microcalorimeter (MMC) g-spectrometer with an ultra-high energy resolution <50 eV for accurate non-destructive assay (NDA) of nuclear materials. Improved NDA simplifies and accelerates safeguards analyses in the nuclear fuel cycle and enhances capabilities to detect the diversion of nuclear materials for illicit purposes. High-resolution MMC g-spectrometers can also improve the accuracy of nuclear data that NDA is based on.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Release of the NDI 2.2.0

The Nuclear Data Interface 2.2.0 has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of the NDI 2.2.0alpha

The Nuclear Data Interface 2.2.0alpha has been released. It includes the addition of charged particle dE/dx (stopping power) data, the ability to read in NDI-formatted binary data, corrections to TN data, CP 2011 and CP 2020 data, and other minor changes and bug fixes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutronic Characteristics of ENDF/B-VIII.0 Compared to ENDF/B-VII.1 for Light-Water Reactor Analysis

The Evaluated Nuclear Data File (ENDF)/B-VIII.0 data library was released in 2018. To assess the new data during development and shortly after release, many validation calculations were performed with static, room-temperature benchmarks. Recently, when performing validation of ENDF/B-VIII.0 for pressurized water reactor depletion calculations, a regression in performance compared to ENDF/B-VII.1 was observed. This paper documents extensive benchmark calculations for light-water reactors performed using continuous energy Monte Carlo code with ENDF/B-VII.1 and -VIII.0 and neutronic characteristics of ENDF/B-VIII.0 are discussed and compared to those of ENDF/B-VII.1. It is our recommendation that ENDF/B data library assessment should include reactor-specific benchmark assessments, including depletion cases, such that these types of regressions may be caught earlier in the data development cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evolving landscape of low-energy nuclear physics publications

Evolution of low-energy nuclear physics publications over the last 120 years has been analyzed using nuclear physics databases. An extensive study of Nuclear Science References, Experimental Nuclear Reaction Data (EXFOR), and Evaluated Nuclear Structure Data File (ENSDF) contents provides a unique picture of refereed and non-refereed nuclear physics references. Significant fractional contributions of non-refereed reports, private communications and conference proceedings in EXFOR and ENSDF databases in the 1970’s reflect extensive experimental campaigns and an insufficient number of research journals. This trend has been reversed in recent years because the number of measurements is much lower, while number of journals is higher. In addition, nuclear physics results are mainly published in a limited number of journals, such as Physical Review C and Nuclear Physics A. In the present work, historic publication trends and averages have been extracted and analyzed using nuclear data mining techniques. Lastly, the results of this study and implications are discussed and conclusions presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The 2016 Edition of the ICSBEP Handbook

Over the past several decades, numerous experiments have been performed worldwide to support criticality safety. These experiments represent a significant investment in infrastructure, expertise, and cost, and are valuable resources of data for present and future research. These valuable assets provide the basis for recording, development, and validation of methods and nuclear data. If the experimental data are lost, the high cost to repeat many of these measurements may be prohibitive. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was established to: 1. Identify a comprehensive set of critical benchmark data and, to the extent possible, verify the data; 2. Evaluate the data and quantify overall uncertainties through various types of sensitivity analyses; 3. Compile the data into a standardized format; 4. Perform calculations of each experiment with standard criticality safety codes; and 5. Formally document the work into a single source of verified benchmark critical data. Annually, contributors from around the world continue to collaborate in the evaluation and review of select benchmark experiments for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook). Further information regarding the ICSBEP, including highlighted criticality safety benchmark evaluations, can be found in the September and October 2003 editions of Nuclear Science and Engineering. Several new evaluations have been prepared for inclusion in the September 2016 edition of the ICSBEP Handbook. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The 2019 Edition of the ICSBEP Handbook

Over the past several decades, innumerable experiments have been performed worldwide to support criticality safety. These experiments represent significant investment in infrastructure, expertise, and cost, and are valuable resources of data for present and future research. These valuable assets provide the basis for recording, development, and validation of methods and nuclear data [1]. If the experimental data are lost, the high cost to repeat many of these measurements would likely be prohibitive. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) was established to: 1. Identify a comprehensive set of critical benchmark data and, to the extent possible, verify the data; 2. Evaluate the data and quantify overall uncertainties through various types of sensitivity analyses; 3. Compile the data into a standardized format; 4. Perform calculations of each experiment with standard criticality safety codes; and 5. Formally document the work into a single source of verified benchmark critical data. Annually, contributors from around the world continue to collaborate in the evaluation and review of select benchmark experiments for inclusion in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) [2]. Further information regarding the ICSBEP, including highlighted criticality safety benchmark evaluations, can be found in the September and October 2003 editions of Nuclear Science and Engineering [3]. New and recently revised evaluations have been prepared for inclusion in the 2019 edition of the ICSBEP Handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Completing the nuclear reaction puzzle of the nucleosynthesis of Mo 92

One of the greatest questions for modern physics to address is how elements heavier than iron are created in extreme astrophysical environments. A particularly challenging part of that question is the creation of the so-called p-nuclei, which are believed to be mainly produced in some types of supernovae. Here, the lack of needed nuclear data presents an obstacle in nailing down the precise site and astrophysical conditions. In this work, we present for the first time measurements on the nuclear level density and average γ strength function of 92 Mo. State-of-the-art p-process calculations systematically underestimate the observed solar abundance of this isotope. Our data provide stringent constraints on the 91 Nb(p,γ) 92 Mo reaction rate, which is the last unmeasured reaction in the nucleosynthesis puzzle of 92 Mo. Based on our results, we conclude that the 92 Mo abundance anomaly is not due to the nuclear physics input to astrophysical model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recommended Nuclear Structure and Decay Data for A = 200 Isobars

Evaluated nuclear structure and decay data for all nuclei with mass number A = 200 ( 200 Os, 200 Ir, 200 Pt, 200 Au, 200 Hg, 200 Tl, 200 Pb, 200 Bi, 200 Po, 200 At, 200 Rn, and 200 Fr), are presented. All available experimental data are compiled and evaluated, and best values for level and gamma-ray energies, quantum numbers, lifetimes, gamma-ray intensities and transition probabilities, as well as other nuclear properties, are recommended. Inconsistencies and discrepancies that exist in the literature are discussed. A number of computer codes (https://www-nds.iaea.org/public/ensdf pgm/) developed by members of the NSDD network were used during the evaluation process. In conclusion, this work supersedes the earlier evaluation by F.G. Kondev and S. Lalkovski (2007Ko42), published in Nuclear Data Sheets 108, 1471 (2007).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of SCALE Continuous-Energy Monte Carlo Tools for Eigenvalue Sensitivity Coefficient Calculations

The TSUNAMI code within the SCALE code system makes use of eigenvalue sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different critical systems, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved fidelity and the desire to extend TSUNAMI analysis to advanced applications has motivated the development of a methodology for calculating sensitivity coefficients in continuous-energy (CE) Monte Carlo applications. The CLUTCH and Iterated Fission Probability (IFP) eigenvalue sensitivity methods were recently implemented in the CE KENO framework to generate the capability for TSUNAMI-3D to perform eigenvalue sensitivity calculations in continuous-energy applications. This work explores the improvements in accuracy that can be gained in eigenvalue and eigenvalue sensitivity calculations through the use of the SCALE CE KENO and CE TSUNAMI continuous-energy Monte Carlo tools as compared to multigroup tools. The CE KENO and CE TSUNAMI tools were used to analyze two difficult models of critical benchmarks, and produced eigenvalue and eigenvalue sensitivity coefficient results that showed a marked improvement in accuracy. The CLUTCH sensitivity method in particular excelled in terms of efficiency and computational memory requirements.

97 MATHEMATICS AND COMPUTING↗

Plutonium Critical Mass Curve Comparison to Mass at Upper Subcritical Limit (USL) Using Whisper

Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the MCNP ® Monte Carlo radiation transport package. Standard approaches to validation rely on the selection of benchmarks based upon expert judgment. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application or set of applications being analyzed. Using these benchmarks, Whisper computes a calculational margin. Whisper attempts to quantify the margin of subcriticality (MOS) from errors in software and uncertainties in nuclear data. The combination of the Whisper-derived calculational margin and MOS comprise the baseline upper subcritical limit (USL), to which an additional margin may be applied by the nuclear criticality safety analyst as appropriate to ensure subcriticality. A series of critical mass curves for plutonium, similar to those found in Figure 31 of LA-10860-MS, have been generated using MCNP6.1.1 and the iterative parameter study software, WORM_Solver. The baseline USL for each of the data points of the curves was then computed using Whisper 1.1. The USL was then used to determine the equivalent mass for plutonium metal-water system. ANSI/ANS-8.1 states that it is acceptable to use handbook data, such as the data directly from the LA-10860-MS, as it is already considered validated (Section 4.3 4) “Use of subcritical limit data provided in ANSI/ANS standards or accepted reference publications does not require further validation.”). This paper attempts to take a novel approach to visualize traditional critical mass curves and allows comparison with the amount of mass for which the k eff is equal to the USL (calculational margin + margin of subcriticality). However, the intent is to plot the critical mass data along with USL, not to suggest that already accepted handbook data should have new and more rigorous requirements for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIA and REWIND: Two New Methodologies for Cross Section Adjustment

This paper presents two new cross section adjustment methodologies intended for coping with the problem of compensations. The first one PIA, Progressive Incremental Adjustment, gives priority to the utilization of experiments of elemental type (those sensitive to a specific cross section), following a definite hierarchy on which type of experiment to use. Once the adjustment is performed, both the new adjusted data and the new covariance matrix are kept. The second methodology is called REWIND (Ranking Experiments by Weighting for Improved Nuclear Data). This new proposed approach tries to establish a methodology for ranking experiments by looking at the potential gain they can produce in an adjustment. Practical applications for different adjustments illustrate the results of the two methodologies against the current one and show the potential improvement for reducing uncertainties in target reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗