Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Imaging of multiple fluorescent proteins in canopies enables synthetic biology in plants

Reverse genetics approaches have revolutionized plant biology and agriculture. Phenomics has the prospect of bridging plant phenotypes with genes, including transgenes, to transform agricultural fields. Genetically encoded fluorescent proteins (FPs) have revolutionized plant biology paradigms in gene expression, protein trafficking and plant physiology. While the first instance of plant canopy imaging of green fluorescent protein (GFP) was performed over 25 years ago, modern phenomics has largely ignored fluorescence as a transgene expression device despite the burgeoning FP colour palette available to plant biologists. Here, we show a new platform for stand-off imaging of plant canopies expressing a wide variety of FP genes. The platform-the fluorescence-inducing laser projector (FILP)-uses an ultra-low-noise camera to image a scene illuminated by compact diode lasers of various colours, coupled with emission filters to resolve individual FPs, to phenotype transgenic plants expressing FP genes. Each of the 20 FPs screened in plants were imaged at >3 m using FILP in a laboratory-based laser range. We also show that pairs of co-expressed fluorescence proteins can be imaged in canopies. The FILP system enabled a rapid synthetic promoter screen: starting from 2000 synthetic promoters transfected into protoplasts to FILP-imaged agroinfiltrated Nicotiana benthamiana plants in a matter of weeks, which was useful to characterize a water stress-inducible synthetic promoter. FILP canopy imaging was also accomplished for stably transformed GFP potato and in a split-GFP assay, which illustrates the flexibility of the instrument for analysing fluorescence signals in plant canopies.

abiotic stress↗

Investigation of Acoustic Fields for the Cassini Spacecraft: Reverberant Versus Launch Environments

The characterization and understanding of the acoustic field within a launch vehicle's payload fairing (PLF) is critical to the qualification of a spacecraft and ultimately to the success of its mission. Acoustic measurements taken recently for the Cassini mission have allowed unique opportunities to advance the aerospace industry's knowledge in this field. Prior to its launch, the expected liftoff acoustic environment of the spacecraft was investigated in a full-scale acoustic test of a Titan IV PLF and Cassini simulator in a reverberant test chamber. A major goal of this acoustic ground test was to quantify and verify the noise reduction performance of special barrier blankets that were designed especially to reduce the Cassirii acoustic environment. This paper will describe both the ground test and flight measurements, and compare the Cassini acoustic environment measured during launch with that measured earlier in the ground test. Special emphasis will be given to the noise reduction performance of the barrier blankets and to the acoustic coherence measured within the PLF.

Hughes, William O.↗

Characterizing the Sensitivity of 40 GHz TES Bolometers for BICEP Array

The BICEP/Keck (BK) experiment aims to detect the imprint of primordial gravitational waves in the cosmic microwave background polarization, which would be direct evidence of the inflation theory. While the tensor-to-scalar ratio has been constrained to be $r_{0.05}<0.06$ at 95% c.l., further improvements on this upper limit are hindered by polarized galactic foreground emissions and removal of gravitational lensing polarization. The 30/40 GHz receiver of the BICEP Array (BA) will deploy at the end of 2019 and will constrain the synchrotron foreground with unprecedented accuracy within the BK sky patch. We will show the design of the 30/40 GHz detectors and test results summarizing its performance. The low optical and atmospheric loading at these frequencies requires our TES detectors to have low saturation power in order to be photon noise dominated. To realize the low thermal conductivity required from a 250 mK base temperature, we developed new bolometer leg designs. We will present the relevant measured detector parameters: $G, T_c, R_n, P_{sat}$, and spectral bands, and noise spectra. We achieved a per bolometer NEP including all noise components of 2.07×10 -17 W/$\sqrt{Hz}$, including an anticipated photon noise level 1.54×10 -17 W/$\sqrt{Hz}$.

47 OTHER INSTRUMENTATION↗

In-Situ NDE Characterization of Kevlar and Carbon Composite Micromechanics for Improved COPV Health Monitoring

This project is a subtask of a multi-center project to advance the state-of-the-art by developing NDE techniques that are capable of evaluating stress rupture (SR) degradation in Kevlar/epoxy (K/Ep) composite overwrapped pressure vessels (COPVs), and damage progression in carbon/epoxy (C/Ep) COPVs. In this subtask, acoustic emission (AE) data acquired during intermittent load hold tensile testing of K/Ep and C/Ep composite tow materials-of-construction used in COPV fabrication were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of composite tow was gained by monitoring AE event rate, energy, source location, and frequency. Source location based on arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to background and grip noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation.

Waller, Jess M.↗

Multimodal Bayesian registration of noisy functions using Hamiltonian Monte Carlo

Functional data registration is a necessary processing step for many applications. The observed data can be inherently noisy, often due to measurement error or natural process uncertainty; which most functional alignment methods cannot handle. A pair of functions can also have multiple optimal alignment solutions, which is not addressed in current literature. In this paper, a flexible Bayesian approach to functional alignment is presented, which appropriately accounts for noise in the data without any pre-smoothing required. Additionally, by running parallel MCMC chains, the method can account for multiple optimal alignments via the multi-modal posterior distribution of the warping functions. To most efficiently sample the warping functions, the approach relies on a modification of the standard Hamiltonian Monte Carlo to be well-defined on the infinite-dimensional Hilbert space. In this work, this flexible Bayesian alignment method is applied to both simulated data and real data sets to show its efficiency in handling noisy functions and successfully accounting for multiple optimal alignments in the posterior; characterizing the uncertainty surrounding the warping functions.

97 MATHEMATICS AND COMPUTING↗

Sources of error and methods to improve accuracy in interface state density analysis using quasi-static capacitance–voltage measurements in wide bandgap semiconductors

Characterizing interface trap states in commercial wide bandgap devices using frequency-based measurements requires unconventionally high probing frequencies to account for both fast and slow traps associated with wide bandgap materials. The C - ψs technique has been suggested as a viable quasi-static method for determining the interface trap state densities in wide bandgap systems, but the results are shown to be susceptible to errors in the analysis procedure. Here this work explores the primary sources of errors present in the C - ψs technique using an analytical model that describes the apparent response for wide bandgap MOS capacitor devices. Measurement noise is shown to greatly impact the linear fitting routine of the 1/C$^{*2}_s$ vs Ψ s plot to calibrate the additive constant in the surface potential/gate voltage relationship, and an inexact knowledge of the oxide capacitance is also shown to impede interface trap state analysis near the band edge. In addition, a slight nonlinearity that is typically present throughout the 1/C$^{*2}_s$ vs Ψ s plot hinders the accurate estimation of interface trap densities, which is demonstrated for a fabricated n-SiC MOS capacitor device. Methods are suggested to improve quasi-static analysis, including a novel method to determine an approximate integration constant without relying on a linear fitting routine.

42 ENGINEERING↗

Attention to quantum complexity

The imminent era of error-corrected quantum computing demands robust methods to characterize quantum state complexity from limited, noisy measurements. We introduce the Quantum Attention Network (QuAN), a classical artificial intelligence (AI) framework leveraging attention mechanisms tailored for learning quantum complexity. Inspired by large language models, QuAN treats measurement snapshots as tokens while respecting permutation invariance. Combined with our parameter-efficient miniset self-attention block, this enables QuAN to access high-order moments of bit-string distributions and preferentially attend to less noisy snapshots. We test QuAN across three quantum simulation settings: driven hard-core Bose-Hubbard model, random quantum circuits, and toric code under coherent and incoherent noise. QuAN directly learns entanglement and state complexity growth from experimental computational basis measurements, including complexity growth in random circuits from noisy data. In regimes inaccessible to existing theory, QuAN unveils the complete phase diagram for noisy toric code data as a function of both noise types, highlighting AI’s transformative potential for assisting quantum hardware.

Kim, Hyejin [Cornell Univ., Ithaca, NY (United Sta↗

On-orbit frequency stability analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks

An on-orbit frequency stability performance analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks is presented. The clock offsets were obtained from measurements taken at the GPS monitor stations which use high performance cesium standards as a reference. Clock performance is characterized through the use of the Allan variance, which is evaluated for sample times of 15 minutes to two hours, and from one day to 10 days. The quartz and rubidium clocks' offsets were corrected for aging rate before computing the frequency stability. The effect of small errors in aging rate is presented for the NAVSTAR-8 rubidium clock's stability analysis. The analysis includes presentation of time and frequency residuals with respect to linear and quadratic models, which aid in obtaining aging rate values and identifying systematic and random effects. The frequency stability values were further processed with a time domain noise process analysis, which is used to classify random noise process and modulation type.

Mccaskill, T. B.↗

A Three-Frequency Feed for Millimeter-Wave Radiometry

A three-frequency millimeter-wave feed horn was developed as part of an advanced component technology task that provides components necessary for higher-frequency radiometers to meet the needs of the Surface Water and Ocean Topography (SWOT) mission. The primary objectives of SWOT are to characterize ocean sub-mesoscale processes on 10-km and larger scales in the global oceans, and to measure the global water storage in inland surface water bodies, including rivers, lakes, reservoirs, and wetlands. In this innovation, the feed provides three separate output ports in the 87-to- 97-GHz, 125-to-135-GHz, and 161-to-183- GHz bands; WR10 for the 90-GHz channel, WR8 for the 130-GHz channel, and WR5 for the 170-GHz channel. These ports are in turn connected to individual radiometer channels that will also demonstrate component technology including new PIN-diode switches and noise diodes for internal calibration integrated into each radiometer front end. For this application, a prime focus feed is required with an edge taper of approximately 20 dB at an illumination angle of 40 deg. A single polarization is provided in each band. Preliminary requirements called for a return loss of better than 15 dB, which is achieved across all three bands. Good pattern symmetry is also obtained throughout all three-frequency bands. This three-frequency broadband millimeter-wave feed also minimizes mass and provides a common focal point for all three millimeter-wave bands.

Hoppe, Daniel J.↗

VERNE: Revealing the Mysteries and Histories of Venus

Introduction: The three Venus missions that were recently selected for upcoming flight (VERITAS, DAVINCI+, and EnVision) will be incredibly valuable to our understanding of Venus’ history, geology, and atmosphere. However, even once completed, key gaps in our knowledge of Venus, and more generally the formation and active processes on rocky, Earth-like planets, will still persist. Remaining questions include 1) how global intrinsic magnetic fields might be maintained on rocky worlds, and how they could then go extinct, and 2) what role atmospheric sulfur chemistry plays in climates of Earth-like planets, which is an increasingly timely subject as Earth’s own atmospheric sulfur content is climbing due to human activity. These questions require in-situ observations from Venus’ cloud deck, at the altitudes at which the UV absorber exists. The Venus Environment Research and Novel Exploration (VERNE) mission will address these questions with an aerial platform that will drift around the equatorial region of the planet for 9 days. VERNE will collect data to determine the identity of the mysterious UV absorber, while also taking magnetic field measurements over the tesserae, the regions on Venus that are most likely to retain remanent crustal magnetization, in order to understand the potential role of a past intrinsically-generated global magnetic field on Venus. Mission Objectives: The two major science objectives that drive the VERNE mission are: 1) Determine the identity of the Venusian unknown ultraviolet absorber(s). First observed approximately a century ago [1], the composition of Venus’ ultraviolet (UV) absorber is one of the oldest mysteries in Venus atmospheric chemistry [2,3]. While several candidate UV absorbers (mostly sulfur species) have been proposed, no consensus has been reached on its composition and its specific interactions with the atmosphere. Determining the identity of the UV absorber will aid climate models by showing how and where incident solar energy is absorbed by the atmosphere and make progress towards understanding the chemical and energetic processes taking place above Venus’ upper cloud deck [4]. 2) Determine if Venus retains evidence of a past, internally-generated magnetic field. While Venus does not currently have an intrinsically-generated magnetic field, evidence for the existence of a past field on Venus and a timeline of its decay will fill in a more holistic picture of the evolution of Venus’ geological record and atmosphere. As the oldest geologic units on the surface, Venus’ tesserae may still have remanent crustal magnetization signatures within the rocky composition [5]. In any case, the signatures detected will provide insight into Venus’ past geological and core dynamo activity. Mission Summary: VERNE includes a 3-part flight system made up of 1) an entry system with a HEEET (Heatshield for Extreme Entry Environment Technology) aeroshell, 2) an orbiter for data relay, and 3) an in-situ balloon and gondola. After entry into Venus’ atmosphere, the balloon will be deployed within the upper cloud deck, at an altitude of 62 km, over a tesserae region. The in-situ data collection will last for the duration of 2 full circumnavigations of the planet, which will take ~9 days. Instrumentation Suite: The four instruments that comprise VERNE’s instrument payload will enable the identification of the unknown UV absorber and the detection of remanent crustal magnetization if it exists in the tesserae. The proposed instrument suite cycle during mission operations is shown in Fig. 1. The four instruments are described below: 1) Adams (ion neutral mass spectrometer) has a range of 18-257 AMU and will detect and distinguish the mixing ratios of O₂, H₂O, H₂SO₄, S, S₂, S₃, S₄, S₅, S₆, S₇, S₈, SO, SO₂, OSSO, SO₃, Cl₂, FeCl₃ and other trace sulfur and organic species. The spatial (longitudinal) and temporal (day/night) variations will be observed throughout 2 circumnavigations with a sample cadence of 12 minutes. 2) Shelley (nephelometer) will determine the size distribution of the aerosols (0.4 to 36 um) in the atmosphere. With a size resolution of <0.7 um, it can determine which mode of H2SO4 is present and characterize the large (>30 um) organic particles previously detected by the Venera and Galileo missions [6,7]. 3) Herbert (UV imager) will measure UV radiance at 283 nm (the wavelength of SO2 absorption) and 365 nm (the unknown part of the absorber). UV images will be taken concurrently with the INMS and nephelometer to correlate UV absorption with abundances of the UV absorber species. 4) Vonnegut (magnetometer) has a range of >600 nT and a precision and accuracy of 1 nT. If magnetized by a past field, the crust may have retained a magnetization of up to 3 A/m2 [5]. With a noise floor of 10 nT, the magnetometer will be able to detect RCM from an altitude of 62 km, even if the thickness of the magnetized crust is just 1 km (Fig. 2). Mission Concept Design: VERNE will be launched with a mass of 3300 kg in an intermediate-high performance class vehicle with a 4-m fairing. The 475-day mission includes 466 days for the cruise, coasting, and orbit initialization phases before entry, descent, and balloon deployment. During the 9-day science phase, the aerial platform will make 2 circumnavigations of the planet at an altitude of 62 km. The INMS and the nephelometer will acquire data for 2 hours during the daytime and nighttime during each circumnavigation, while the UV imager will be on for the duration of the daytime, and the magnetometer will be operational throughout the entirety of the science phase. Data will be stored and processed with the JPL-designed Sphinx command and data handling system. Data will be sent from the balloon to the orbiter using an S-band relay link, stored on the orbiter, and then forwarded to Earth where it will be received by the DSN. Conclusion: VERNE will fill key gaps in our understanding of the history and ongoing processes related to the geology and atmosphere of Venus and rocky worlds in general. Even with adequate flight system contingencies and expected costs below the $900M New Frontiers cost cap, VERNE is not without its risks and challenges. Further trade spaces to explore include 1) using solely battery power vs. including solar panels to increase the mission duration and 2) investigating the use of lightweight materials and 3D-printed structures to reduce the gondola mass, among others. Acknowledgments: We would like to thank the JPL Planetary Science Summer School, especially our mentors Troy Hudson, Karl Mitchell, and Leslie Lowes, as well as our Team-X study lead Al Nash and the members of Team-X. We’d additionally like to thank our review panel for asking insightful questions and providing valuable feedback. References: [1] Ross, F. E. (1928) Astrophysical J., 68, 57-92. [2] Rossow, W. B. et al. (1980) J. Geophysical Research, 85, 8107-8128. [3] Pinto, J. P. et al. (2021) Nature Communications, 12, 175. [4] Titov, D. V. et al. (2007) Cosmic Research, 21, 401. [5] O’Rourke, J. et al. (2019) Geophysical Research Lett., 46, 5768–5777. [6] Limaye, S. S. et al. (2018) Astrobiology, 18(9), 1181-1198. [7] Grinspoon, D. H. et al. (2013) Planetary and Space Sci., 41(7), 515-542. [8] Parker, R. L. (2003) J. Geophysical Research, 108, 5006. *The cost information contained in this document is of a budgetary and planning nature and is intended for informational purposes only. It does not constitute a commitment on the part of JPL and/or Caltech.

H Alpert↗

SPLENDAQ: A Detector-Agnostic Data Acquisition System for Small-Scale Physics Experiments

Many scientific applications from rare-event searches to condensed matter system characterization to high-rate nuclear experiments require time-domain triggering on a raw stream of data, where the triggering is generally threshold-based or randomly acquired. When carrying out detector R &D, there is a need for a general data acquisition (DAQ) system to quickly and efficiently process such data. In the SPLENDOR collaboration, we are developing the Python-based SPLENDAQ package for this exact purpose—it offers two main features for offline analysis of continuous data: a threshold triggering algorithm based on the time-domain optimal filter formalism and an algorithm for randomly choosing nonoverlapping segments for noise measurements. Further, combined with the commercially available Moku platform, developed by Liquid Instruments, we have a full pipeline of event building off raw data with minimal setup. Here, we review the underlying principles of this detector-agnostic DAQ package and give concrete examples of its utility in various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A quantum eigenvalue solver based on tensor networks

Electronic ground states are of central importance in chemical simulations, but have remained beyond the reach of efficient classical algorithms except in cases of weak electron correlation or one-dimensional spatial geometry. We introduce a hybrid quantum-classical eigenvalue solver that constructs a wavefunction ansatz from a linear combination of matrix product states in rotated orbital bases, enabling the characterization of strongly correlated ground states with arbitrary spatial geometry. The energy is converged via a gradient-free generalized sweep algorithm based on quantum subspace diagonalization, with a potentially exponential speedup in the off-diagonal matrix element contractions upon translation into compact quantum circuits of linear depth in the number of qubits. Chemical accuracy is attained in numerical experiments for both a stretched water molecule and an octahedral arrangement of hydrogen atoms, achieving substantially better correlation energies compared to a unitary coupled-cluster benchmark, with orders of magnitude reductions in quantum resource estimates and a surprisingly high tolerance to shot noise. This proof-of-concept study suggests a promising new avenue for scaling up simulations of strongly correlated chemical systems on near-term quantum hardware.

chemistry↗

Coexistent Quantum Channel Characterization Using Spectrally Resolved Bayesian Quantum Process Tomography

The coexistence of quantum and classical signals over the same optical fiber with minimal degradation of the transmitted quantum information is critical for operating large-scale quantum networks over the existing communications infrastructure. In this work, we systematically characterize the quantum channel that results from simultaneously distributing approximate single-photon polarization-encoded qubits and classical light of varying intensities through fiber-optic channels of up to 15 km. Using spectrally resolved quantum process tomography with a Bayesian reconstruction method that we develop, we estimate the full quantum channel from experimental photon counting data, both with and without classical background. Furthermore, although we find the exact channel description to be a weak function of the pump polarization, we nevertheless show that the coexistent fiber-based quantum channel has high process fidelity with an ideal depolarizing channel when the noise is dominated by Raman scattering. These results provide a basis for the future development of quantum repeater designs and quantum error-correcting codes for real-world channels and inform models used in the analysis and simulation of quantum networks.

97 MATHEMATICS AND COMPUTING↗

Universal CMB 𝐵-mode spectrum from early causal tensor sources

Many early Universe scenarios predict postinflationary tensor perturbations from causality-limited, subhorizon sources. While the microphysical details may be different, as long as these sources are bounded in duration and correlation length, their tensor power spectra exhibit a universal scaling behavior at small wave number: 𝒫 ℎ ⁡(𝑘)∝𝑘 3 , corresponding to white noise on superhorizon scales at the time of production. If these early causal tensor sources (ECTs) exclusively produce gravitational waves before redshift 𝑧 ∼10 5 , this scaling is realized on all of the scales observed in the CMB, and thus yields a universal multipole distribution for the 𝐵-mode angular power spectrum. Unlike the scale-invariant distributions of inflationary 𝐵 modes, ECTs generically predict enhanced power on small scales and suppressed power on large scales, which allows these source classes to be distinguished given measurements over a sufficient range of angular scales. In this paper, we introduce a unified framework for characterizing ECTs and demonstrate how their universal infrared scaling manifests in low-frequency observables, including CMB 𝐵 modes and stochastic gravitational wave spectral densities. We illustrate this mapping with representative case studies of this universality class involving first-order phase transitions, topological defects, and enhanced scalar perturbations, which source tensor modes at second order in perturbation theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Progress of Multicolor Single Detector to Detector Array Development for Remote Sensing

Knowledge of the spatial and temporal distribution of atmospheric species such as CO2, O3, H2O, and CH4 is important for understanding the chemistry and physical cycles involving Earth s atmosphere. Although several remote sensing techniques are suitable for such measurements they are considered high cost techniques involving complicated instrumentation. Therefore, simultaneous measurement of atmospheric species using a single remote sensing instrument is significant for minimizing cost, size and complexity. While maintaining the instrument sensitivity and range, quality of multicolor detector, in terms of high quantum efficiency and low noise are vital for these missions. As the first step for developing multicolor focal plan array, the structure of a single element multicolor detector is presented in this paper. The detector consists of three p-n junction layers of Si, GaSb and InAs wafer bonded to cover the spectral range UV to 900 nm, 800 nm to 1.7 m, and 1.5 m to 3.4 m, respectively. Modeling of the absorption coefficient for each material was carried out for optimizing the layers thicknesses for maximum absorption. The resulted quantum efficiency of each layer has been determined except InAs layer. The optical and electrical characterization of each layer structure is reported including dark current and spectral response measurements of Si pin structure and of GaSb and InAs p-n junctions. The effect of the material processing is discussed.

Abedin, M. Nurul↗

A tailored fast thioacidolysis method incorporating multi-reaction monitoring mode of GC-MS for higher sensitivity on lignin monomer quantification

Abstract Thioacidolysis is widely used for lignin structural characterization by cleaving β-aryl ethers to release syringyl (S), guaiacyl (G), and p -hydroxyphenyl (H) monomers followed by GC analysis. However, the traditional thioacidolysis method requires tedious extraction steps with chlorinated solvent underlying harmful to health, limiting its efficiency and application. Herein, an improved thioacidolysis method with high sensitivity for the quantitation of lignin-derived monomers was developed. The improved protocol used a quick, streamlined procedure to recover the monomeric products using ethyl acetate as extracting solvent and MS detector in multi-reaction monitoring mode to enhance its ability to detect extremely low concentration (0.1 ppb with signal-to-noise higher than 2) of monomeric products. Additionally, a fast GC program was established to speed up the GC quantitation. Several representative lignocellulose samples, including gymnosperm, angiosperm, and poaceae, were used to test this tailored method. The results demonstrated that the ratios of lignin monomer compositions determined by this method were consistent with that of traditional procedure despite the slightly higher monomer yields measured. More importantly, this method uses non-chlorinated solvent for microscale extraction and requires no evaporation step for workup, which is a green and efficient way for the quantification of lignin monomer compositions.

Forestry↗

Aura OMI Observations of Global SO2 and NO2 Pollution from 2005 to 2013

The Ozone Monitoring Instrument (OMI), a NASA partnership with the Netherlands and Finland, flies on the NASA Aura satellite and uses reflected sunlight to measure the two critical atmospheric trace gases: nitrogen dioxide (NO2) and sulfur dioxide (SO2) characterizing daily air quality. Both gases and the secondary pollutants they produce (particulate matter, PM2.5, and tropospheric ozone) are USEPA designated criteria pollutants, posing serious threats to human health and the environment (e.g., acid rain, plant damage and reduced visibility). Our group at NASA GSFC has developed and maintained OMI standard SO2 and NO2 data products. We have recently released an updated version of the standard NO2 L2 and L3 products (SP v2.1) and continue improving the algorithm. We are currently in the process of releasing next generation pollution SO2 product, based on an innovative Principal Component Analysis (PCA) algorithm, which greatly reduces the noise and biases. These new standard products provide valuable datasets for studying anthropogenic pollution on local to global scales. Here we highlight some of the OMI observed changes in air quality over several regions. Over the US average NO2 and SO2 pollution levels had decreased dramatically as a result of both technological improvements (e.g., catalytic converters on cars) and stricter regulations of emissions. We see continued decline in pollution over Europe. Over China OMI observed an increase of about 60 percent in NO2 pollution between 2005 and 2013, despite a temporal reversal of the growing trend due to both 2008 Olympic Games and the economic recession in 2009. Chinese SO2 pollution seems to have stabilized since peaking in 2007, probably due to government efforts to curb SO2 emissions from the power sector. We have also observed large increases in both SO2 and NO2 pollution particularly in Eastern India where a number of large new coal power plants had been built in recent years. We expect that further improvements in the OMI NO2 and SO2 products will allow more robust quantification of long-term trends in global air quality.

SO2↗

Resolving Faint Structures in the Debris Disk Around TWA 7* Tentative Detections of an Outer Belt, a Spiral Arm, and a Dusty Cloud

Context. Debris disks are the intrinsic by-products of the star and planet formation processes. Most likely due to instrumental limitations and their natural faintness, little is known about debris disks around low mass stars, especially when it comes to spatially resolved observations. Aims. We present new VLT/SPHERE IRDIS dual-polarization imaging (DPI) observations in which we detect the dust ring around the M2 spectral type star TWA 7. Combined with additional angular differential imaging observations we aim at a fine characterization of the debris disk and setting constraints on the presence of low-mass planets. Methods. We modeled the SPHERE DPI observations and constrain the location of the small dust grains, as well as the spectral energy distribution of the debris disk, using the results inferred from the observations, and performed simple N-body simulations. Results. We find that the dust density distribution peaks at ~0.72′′ (25 au), with a very shallow outer power-law slope, and that the disk has an inclination of ~13° with a position angle of ~91° east of north. We also report low signal-to-noise ratio detections of an outer belt at a distance of ~1.5′′ (~52 au) from the star, of a spiral arm in the southern side of the star, and of a possible dusty clump at 0.11′′. These findings seem to persist over timescales of at least a year. Using the intensity images, we do not detect any planets in the close vicinity of the star, but the sensitivity reaches Jovian planet mass upper limits. We find that the SED is best reproduced with an inner disk at ~0.2′′ (~7 au) and another belt at 0.72′′ (25 au). Conclusions. We report the detections of several unexpected features in the disk around TWA 7. A yet undetected 100 Solar Mass planet with a semi-major axis at 20−30 au could possibly explain the outer belt as well as the spiral arm. We conclude that stellar winds are unlikely to be responsible for the spiral arm.

VLT/SPHERE IRDIS↗