Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Muon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Towards the construction of the Mu2e electromagnetic calorimeter at Fermilab

Mu2e will search for the Charge Lepton Flavor Violating (CLFV) conversion of a muon into an electron in the field of a nucleus. A clean discovery signature is provided by the mono-energetic conversion electron (E e = 104.96 MeV). If no events are observed, Mu2e will set a limit on the ratio between the conversion and the nuclear capture rate below 3 × 10$^{-17}$ (at 90% C.L.). In order to confirm that the observed candidate is an electron, the calorimeter resolution requirements are to provide E res < 10%, T res < 500 ps for 100 MeV electrons while working in vacuum and in a high radiation environment and high magnetic field. The calorimeter is made of two annular aluminum disks, each one filled with 674 pure CsI crystals read out by SiPMs. A sophisticated mechanics and cooling system has been developed to support the crystals and cool the sensors. Radiation hard analog and fast digital electronics have been developed. In this paper the QC tests performed on the produced components and the construction status are reported, as well as the results obtained on the large size prototype with test beam data and at a cosmic ray test stand.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation light detection in the long-drift ProtoDUNE-DP liquid argon TPC

ProtoDUNE-DP is a 6 × 6 × 6m$^{3}$ liquid argon time-projection-chamber (LArTPC) operated at the Neutrino Platform at CERN in 2019-2020 as a prototype of the DUNE Far Detector. DUNE is a dual-site experiment for long-baseline neutrino oscillation studies, neutrino astrophysics and nucleon decay searches. The light signal in these detectors is crucial to provide precise timing capabilities. In ProtoDUNE-DP, scintillation light produced by cosmic muons in the LArTPC is collected by the photomultiplier tubes (PMTs) placed up to 7 m away from the point of interaction. The scintillation light production and propagation processes are analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement of superconductivity at a quantum critical point in (Ca x Sr 1- x ) 3 Rh 4 Sn 13

We report microscopic studies by muon spin spectroscopy of the superconducting properties as a function of chemical and hydrostatic pressure in the cubic ternary intermetallic (Ca x Sr 1-x ) 3 Rh 4 Sn 13 compounds. We find evidence of a quantum critical point at a critical pressure pc in the superconducting phase, where the superfluid density increases by a factor of two and the superconducting pairing strength displays a pronounced maximum. The enhancement of superconductivity is related to the structural phase transition at p c , which is accompanied by profound changes of the Fermi surface associated to the suppression of a charge density wave (CDW). The quantum critical point separates a superconducting phase coexisting with CDW from a pure superconducting phase, while in both phases superconductivity has a strong-coupling phonon-mediated BCS-like s-wave character. Together with the related isoelectronic compound (Ca x Sr 1-x ) 3 Ir 4 Sn 13 , this system shows that conventional BCS superconductors in the presence of competing orders may display behaviour and characteristics of unconventional superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibrated particle identification for Belle II

We present several efforts aimed at improving charged particle identification at the Belle II experiment. We define an ablation test to quantify and evaluate the impact of each sub-detector on the global particle identification performance. We demonstrate that the performance of the identification scheme can be improved via a simple calibration of the sub-detector likelihoods through a set of per hypothesis, per sub-detector weights. Finally, we present preliminary results on an improved definition of the likelihoods contributed by the electromagnetic calorimeter. A set of multiclass boosted decision trees is trained to exploit the shape of energy depositions of different particle species. In simulated $B\bar{B}$ events, the pion-to-electron and muon fake rates are reduced by 55% and 31% respectively at low-medium momentum.

Hohmann, Marcel [Univ. of Melbourne, Parkville, VI↗

Design and performance of the first IceAct demonstrator at the South Pole

Here in this paper we describe the first results of IceAct, a compact imaging air-Cherenkov telescope operating in coincidence with the IceCube Neutrino Observatory (IceCube) at the geographic South Pole. An array of IceAct telescopes (referred to as the IceAct project) is under consideration as part of the IceCube-Gen2 extension to IceCube. Surface detectors in general will be a powerful tool in IceCube-Gen2 for distinguishing astrophysical neutrinos from the dominant backgrounds of cosmic-ray induced atmospheric muons and neutrinos: the IceTop array is already in place as part of IceCube, but has a high energy threshold. Although the duty cycle will be lower for the IceAct telescopes than the present IceTop tanks, the IceAct telescopes may prove to be more effective at lowering the detection threshold for air showers. Additionally, small imaging air-Cherenkov telescopes in combination with IceTop, the deep IceCube detector or other future detector systems might improve measurements of the composition of the cosmic ray energy spectrum. In this paper we present measurements of a first 7-pixel imaging air Cherenkov telescope demonstrator, proving the capability of this technology to measure air showers at the South Pole in coincidence with IceTop and the deep IceCube detector.

47 OTHER INSTRUMENTATION↗

First Calorimetric Energy Reconstruction of Beam Events with ARAPUCA Light Detector in ProtoDUNE-SP

ProtoDUNE Single Phase at CERN is the large scale prototype for the far detector of the future DUNE experiment. ProtoDUNE is in stable operation since Oct. 2018 at the CERN Neutrino Platform. Test beam data in the energy range of sub-GeV to a few GeV were collected in fall 2018 providing a set of key measurements. Particles (electrons, protons, pions, muons and kaons) are identified combining information from a set of beam-line detectors (Time of Flight, Cherenkov) and TPC reconstruction. Three different technologies are implemented in the protoDUNE photon detector system (PDS). Results from the ARAPUCA response, one of the PDS components, are presented providing first calorimetric energy measurements and particle ID of beam events from LAr scintillation light signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Liquid Argon In A Testbeam (LArIAT) Experiment

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, electrons, protons, and kaons in the momentum range 0∼30–0140 MeV/c. This paper describes the main aspects of the detector and beamline, and also reports on calibrations performed for the detector and beamline components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated detector simulation and reconstruction parametrization using machine learning

Rapidly applying the effects of detector response to physics objects (e.g. electrons, muons, showers of particles) is essential in high energy physics. Presently available tools for the transformation from truth-level physics objects to reconstructed detector-level physics objects involve manually defining resolution functions. These resolution functions are typically derived in bins of variables that are correlated with the resolution (e.g. pseudorapidity and transverse momentum). This process is time consuming, requires manual updates when detector conditions change, and can miss important correlations. Machine learning offers a way to automate the process of building these truth-to-reconstructed object transformations and can capture complex correlation for any given set of input variables. Such machine learning algorithms, with sufficient optimization, could have a wide range of applications: improving phenomenological studies by using a better detector representation, allowing for more efficient production of Geant4 simulation by only simulating events within an interesting part of phase space, and studies on future experimental sensitivity to new physics.

47 OTHER INSTRUMENTATION↗

Fast inference of Boosted Decision Trees in FPGAs for particle physics

We describe the implementation of Boosted Decision Trees in the hls4ml library, which allows the translation of a trained model into FPGA firmware through an automated conversion process. Thanks to its fully on-chip implementation, hls4ml performs inference of Boosted Decision Tree models with extremely low latency. With a typical latency less than 100 ns, this solution is suitable for FPGA-based real-time processing, such as in the Level-1 Trigger system of a collider experiment. These developments open up prospects for physicists to deploy BDTs in FPGAs for identifying the origin of jets, better reconstructing the energies of muons, and enabling better selection of rare signal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An approach to light distribution for the calibration of high energy physics calorimeters

In high energy physics experiments, calorimeters are calibrated to produce precise and accurate results. Laser light can be used for calibration when the detectors are sensitive to photons in that particular energy range, which is often the case. Moreover, it is not unusual that detection systems consist of hundreds of channels that have to be calibrated independently, which produce stringent requirements on the light distribution system in terms of temporal and spatial stability, energy distribution and timing. Furthermore, the economic factor and the ease of production have to be taken into account. Overall, we present a prototype light distribution system, based on a series of optical beamsplitters, developed for the Muon g-2 experiment at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the CMS Level-1 trigger in proton-proton collisions at $\sqrt{s} =$ 13 TeV

At the start of Run 2 in 2015, the LHC delivered proton-proton collisions at a center-of-mass energy of 13\TeV. During Run 2 (years 2015–2018) the LHC eventually reached a luminosity of 2.1× 1034 cm-2s-1, almost three times that reached during Run 1 (2009–2013) and a factor of two larger than the LHC design value, leading to events with up to a mean of about 50 simultaneous inelastic proton-proton collisions per bunch crossing (pileup). The CMS Level-1 trigger was upgraded prior to 2016 to improve the selection of physics events in the challenging conditions posed by the second run of the LHC. This paper describes the performance of the CMS Level-1 trigger upgrade during the data taking period of 2016–2018. The upgraded trigger implements pattern recognition and boosted decision tree regression techniques for muon reconstruction, includes pileup subtraction for jets and energy sums, and incorporates pileup-dependent isolation requirements for electrons and tau leptons. In addition, the new trigger calculates high-level quantities such as the invariant mass of pairs of reconstructed particles. The upgrade reduces the trigger rate from background processes and improves the trigger efficiency for a wide variety of physics signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The continuous readout stream of the MicroBooNE liquid argon time projection chamber for detection of supernova burst neutrinos

The MicroBooNE continuous readout stream is a parallel readout of the MicroBooNE liquid argon time projection chamber (LArTPC) which enables detection of non-beam events such as those from a supernova neutrino burst. The low energies of the supernova neutrinos and the intense cosmic-ray background flux due to the near-surface detector location makes triggering on these events very challenging. Instead, MicroBooNE relies on a delayed trigger generated by SNEWS (the Supernova Early Warning System) for detecting supernova neutrinos. The continuous readout of the LArTPC generates large data volumes, and requires the use of real-time compression algorithms (zero suppression and Huffman compression) implemented in an FPGA (field-programmable gate array) in the readout electronics. In this paper we present the results of the optimization of the data reduction algorithms, and their operational performance. To demonstrate the capability of the continuous stream to detect low-energy electrons, a sample of Michel electrons from stopping cosmic-ray muons is reconstructed and compared to a similar sample from the lossless triggered readout stream.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production and tests of the ADDC for the Micromegas detector of the ATLAS New Small Wheel

The Large Hadron Collider (LHC) at CERN will perform a series of upgrades to allow luminosity increases during the next physics runs expected from 2022 on. These will also significantly increase the trigger rates of all the detectors. As part of the ATLAS Phase-I upgrade, the current Small Wheel muon detectors will be replaced with state-of-the-art New Small Wheel (NSW) detectors to cope with the increased luminosity of the LHC. The Address in Real Time Data Driver Card (ADDC) is designed to transmit the trigger data from the resistive Micro-Mesh Gaseous Structure (Micromegas) detectors of the NSW. The ART ASIC on the ADDC is a customdesigned chip to receive theAddress in Real Time (ART) signals from theVMMfront-end ASIC and perform hit-selection processing. The processed trigger data is then sent to the Trigger Processor (TP) through optical links. A total of 512 ADDCs will be installed on the detector close to the front-end boards. Therefore, those cards must be able to work properly in a high radiation and magnetic field environment. Furthermore, after four rounds of prototyping, the ADDC production was launched in January of 2019. 600 ADDC boards have been produced and tested with an automated test stand. This test setup can simulate the front-end signals and provide "Level-1 Data Driver Card" (L1DDC) functions as well as part of the TP functions. Thus, the ADDC functionality and stability can be verified without the remaining NSW electronics. This paper describes the ADDC hardware prototype development, radiation and integration testing, and the ADDC automated production test procedure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗