Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minimum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Minimum Spectral Bandwidth in Echo Seeded Free Electron Lasers

This paper examines the impact of non-linear longitudinal phase distortions on the spectral bandwidth in echo seeded free electron lasers (FELs). It extends the existing theory developed in Ref.~\cite{HemsingBunchingPhase} for echo-enabled harmonic generation (EEHG) to include finite laser pulse durations. An analytic expression for the shape of the optimized longitudinal bunching envelope is derived, and is used to determine the laser and electron beam pulse durations that minimize the seeded bandwidth in the presence of arbitrary phase distortions. The time-bandwidth product (TBP) is also derived, and is shown that the TBP and the bandwidth increase by no more than $\sqrt{2}$ from their transform-limited values when the bandwidth is minimized.

Hemsing, Erik↗

Production of Neutrons by Transport of a GCR Solar Minimum Spectrum through Shielding - Paper 112

The requirements for radiation instrumentation in space can be quite different from those used for terrestrial applications. For example, most neutron instruments used for dosimetry applications used on Earth are sensitive to fission neutron energies and lower, and as such are only useful for neutron energies below 20 to 50 MeV. In space, neutrons are created by galactic cosmic ray (GCR) and solar energetic particle (SEP) interactions in materials, and as such can attain TeV energies and higher. The purpose of this study is to determine the significance of the flux of high energy neutrons in space, and to what degree neutron instruments in space must be sensitive to those high energy neutrons. PHITS transport code calculations of secondary neutron production through various thicknesses of aluminum and water shielding indicate that a significant fraction of the neutron flux and neutron effective dose comes from neutrons above 20 MeV. Measurement of high energy neutrons in space is a difficult task, especially given that the measurement will take place in a mixed radiation field where any signal from an incident neutron must be separated from signals generated by gamma rays, electrons and charged hadrons. Conventional neutron detection methodology dictates that the ability to detect high energy neutrons with a sufficient efficiency depends on the mass of the neutron detector, to first order. The more mass a neutron detector has, the higher the probability of detecting a high energy neutron. However, adding mass comes at a premium in space, often adding costs that prohibit the implementation of a new design with more mass. Thus, to accurately measure the effective dose to humans in space from secondary neutron irradiation, it requires novel methodologies that can stretch the limits of low-mass neutrons detectors, such as developing versatile response functions that are well characterized and can function over a wide range of very different neutron energy spectra. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Shielding Design For Minimum Materials Cost or Mass - Paper 128

Material costs dominate some shielding design problems. This is certainly the case for manned nuclear power space applications for which shielding is essential and the cost of launching by rocket from Earth is high. In such situations or in those where shielding volume or mass is constrained, it is important to optimize the design. Although trial and error synthesis methods may succeed, a more systematic approach is warranted. Design automation may also potentially reduce engineering costs. The objective is to automate the design of optimal radiation shielding to meet specified attenuation requirements given a menu of allowed shielding materials, their properties and their delivered costs per unit volume. The cost-optimal design is one which, at each location in the shield, chooses the menu material minimizing a particular functional of forward and adjoint angular fluxes plus material cost. Thus a Boltzmann forward and adjoint angular flux solver with additional calculations can evaluate whether a shield design is optimal or whether improvements are possible. An iterative algorithm based on approximated optimality is proposed to solve for the optimal shield design and numerical experiments with it are discussed. The future use of 3D Boltzmann solvers will allow extending results to shaped shield designs in which material is not wasted to maintain unneeded spherical symmetry. The largest cost savings of automated optimal design of shielding is expected to be for applications involving nuclear powered manned space missions where the required shielding attenuation of radiation and costs are both large. However, less exotic applications such as the shielding of radiation facilities on Earth could also benefit from optimal shielding design, and automation of the design process may reduce engineering costs. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

A study of IMRT planning parameters on planning efficiency, delivery efficiency, and plan quality

Purpose: To improve planning and delivery efficiency of head and neck IMRT without compromising planning quality through the evaluation of inverse planning parameters.Methods: Eleven head and neck patients with pre-existing IMRT treatment plans were selected for this retrospective study. The Pinnacle treatment planning system (TPS) was used to compute new treatment plans for each patient by varying the individual or the combined parameters of dose/fluence grid resolution, minimum MU per segment, and minimum segment area. Forty-five plans per patient were generated with the following variations: 4 dose/fluence grid resolution plans, 12 minimum segment area plans, 9 minimum MU plans, and 20 combined minimum segment area/minimum MU plans. Each plan was evaluated and compared to others based on dose volume histograms (DVHs) (i.e., plan quality), planning time, and delivery time. To evaluate delivery efficiency, a model was developed that estimated the delivery time of a treatment plan, and validated through measurements on an Elekta Synergy linear accelerator. Results: The uncertainty (i.e., variation) of the dose-volume index due to dose calculation grid variation was as high as 8.2% (5.5 Gy in absolute dose) for planning target volumes (PTVs) and 13.3% (2.1 Gy in absolute dose) for planning at risk volumes (PRVs). Comparison results of dose distributions indicated that smaller volumes were more susceptible to uncertainties. The grid resolution of a 4 mm dose grid with a 2 mm fluence grid was recommended, since it can reduce the final dose calculation time by 63% compared to the accepted standard (2 mm dose grid with a 2 mm fluence grid resolution) while maintaining a similar level of dose-volume index variation. Threshold values that maintained adequate plan quality (DVH results of the PTVs and PRVs remained satisfied for their dose objectives) were 5 cm{sup 2} for minimum segment area and 5 MU for minimum MU. As the minimum MU parameter was increased, the number of segments and delivery time were decreased. Increasing the minimum segment area parameter decreased the plan MU, but had less of an effect on the number of segments and delivery time. Our delivery time model predicted delivery time to within 1.8%. Conclusions: Increasing the dose grid while maintaining a small fluence grid allows for improved planning efficiency without compromising plan quality. Delivery efficiency can be improved by increasing the minimum MU, but not the minimum segment area. However, increasing the respective minimum MU and/or the minimum segment area to any value greater than 5 MU and 5 cm{sup 2} is not recommended because it degrades plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗