Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIVER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Heavy Metal Accumulation in the Intestinal Tapeworm Proteocephalus macrophallus Infecting the Butterfly Peacock Bass (Cichla ocellaris), from Southeastern Brazil

Here we evaluate the potential of heavy metal accumulation of Proteocephalus macrophallus parasitizing the Butterfly Peacock Bass (Cichla ocellaris). A total of 19 fish specimens were collected. From the hosts, samples of intestine, liver, muscle, and parasites were taken. Heavy metal concentrations (Al, As, Ba, Cd, Cr, Fe, Hg, Mg, Mn, Ni, Pb, Ti, and Zn) were obtained using Atomic Absorption Spectrometry. All analyzed elements was found in higher concentrations in the parasites comparing to its host tissues. The bioconcentration factors were higher in the intestine, varying between 5.91 (Ti) to 8.00 (Ba), followed by the muscle, 1.88 (Mg) to 6.39 (Zn), and liver, 1.67 (Al) to 2.02 (Ba). These results show that at the infection site heavy metal concentrations are reduced, since the elements are absorbed directly from the intestinal wall by the parasites. In general, P. macrophallus presents a reasonable capacity of metal accumulation comparing to its hosts.

54 ENVIRONMENTAL SCIENCES↗

Tissue sampling in the era of precision medicine: comparison of percutaneous biopsies performed for clinical trials or tumor genomics versus routine clinical care

Purpose: The purpose of the study was to determine if patients undergoing percutaneous biopsy for genetic profiling are undergoing more biopsies (procedures, passes per procedure), or experiencing more procedure-related complications. Methods: 60 patients undergoing biopsy procedures for genetic profiling were retrospectively compared with 60 consecutive control patients undergoing routine biopsies. Procedural details and related complications were collected. Results were analyzed using t-tests and logistic regression. Results: Biopsied organs included mainly lung (n = 31), liver (n = 50), and lymph nodes (n = 18). The average number of core biopsy passes was 3.45 in the study group and 2.18 in the control group (0.73, 1.81; p = 0.0001). The average study patient underwent 1.44 biopsy procedures by radiology from 2016 to 2017, whereas the average control patient underwent 1.08 (0.1657, 0.5010, p = 0.0002). Results were similar when looking at the subset of patients undergoing liver biopsies. In our cohort of 120 patients total, only 6 complications were noted. There were 4 complications in the control patients and 2 complications in the study patients, all of which were pneumothoraces in patients undergoing lung biopsy; only 2 of these required treatment. The odds ratio for a complication occurring from an increase in one core biopsy is 1.07 (0.601, 1.573; p = 0.775), suggesting no significant relationship among the number of biopsies taken and the probability of complication in this cohort. Conclusions: Patients being biopsied for genetic profiling or clinical study enrollment are undergoing more biopsy procedures and more biopsy passes per procedure, but are not experiencing a detectable increased rate of complications in this small cohort, single-center study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter-reader agreement of magnetic resonance imaging proton density fat fraction and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis

Purpose: To determine the inter-reader agreement of magnetic resonance imaging proton density fat fraction (PDFF) and its longitudinal change in a clinical trial of adults with nonalcoholic steatohepatitis (NASH). Study type: We performed a secondary analysis of a placebo-controlled randomized clinical trial of a bile acid sequestrant in 45 adults with NASH. A six-echo spoiled gradient-recalled-echo magnitude-based fat quantification technique was performed at 3 T. Three independent readers measured MRI-PDFF by placing one primary and two additional regions of interest (ROIs) in each segment at both time points. Cross-sectional agreement between the three readers was evaluated using intra-class correlation coefficients (ICCs) and coefficients of variation (CV). Additionally, we used Bland–Altman analyses to examine pairwise agreement between the three readers at baseline, end of treatment (EOT), and for longitudinal change. Results: Using all ROIs by all readers, mean PDFF at baseline, at EOT, and mean change in PDFF was 16.1%, 16.0%, and 0.07%, respectively. The 27-ROI PDFF measurements had 0.998 ICC and 1.8% CV at baseline, 0.998 ICC and 1.8% CV at EOT, and 0.997 ICC for longitudinal change. The 9-ROI PDFF measurements had corresponding values of 0.997 and 2.6%, 0.996 and 2.4%, and 0.994. Using 27 ROIs, the magnitude of the bias between readers for whole-liver PDFF measurement ranged from 0.03% to 0.06% points at baseline, 0.01% to 0.07% points at EOT, and 0.01% to 0.02% points for longitudinal change. Conclusion: Inter-reader agreement for measuring whole-liver PDFF and its longitudinal change is high. 9-ROI measurements have only slightly lower agreement than 27-ROI measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-energy CT in the obese: a preliminary retrospective review to evaluate quality and feasibility of the single-source dual-detector implementation

Purpose: To determine the feasibility of performing dual-energy CT with a single-source spectral detector system in obese patients. Materials and methods: Retrospective, IRB-approved review of 28 patients weighing ≥ 270 lbs (122 kg) who underwent CT of the abdomen on a single-source spectral detector system was performed. Two blinded, independent radiologists rated relative preference between conventional CT images taken at 120 kVp (CCT120) and monoenergetic 70 keV equivalent (MonoE70) as well as iodine map image quality in the spleen, pancreas, kidneys, and liver. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between conventional CT and MonoE70 images and correlated with body habitus markers of weight, height, and abdominal diameter. Results: MonoE70 images were preferred by radiologists 100% of the time (1-sample t test, p < 0.0001) over conventional CCT120 images. Noise was significantly lower; SNR and CNR were significantly higher in MonoE70 images than in CCT120 images (paired t tests, p < 0.0001). Mean iodine map rating (scale 1–5) was 4.54 ± 0.58, denoting near homogenous and complete iodine mapping through the spleen, pancreas, kidneys, and liver for the majority of patients. Body habitus markers were not significantly correlated with image preference score; noise; MonoE70 SNR; MonoE70 CNR; change in noise, SNR, or CNR from CCT120 to MonoE70, or iodine map quality; ordinal and linear regression, p = 0.2547, p = 0.6837, p = 0.1888, p = 0.5489, p = 0.9830, p = 0.8849, p = 0.8741, p = 0.1522, respectively. Conclusion: The single-source spectral detector implementation of dual-energy CT provides viable, high-quality imaging for obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shear wave elastography prior to transjugular intrahepatic portosystemic shunt may predict the decrease in hepatic vein pressure gradient

Background: Transjugular intrahepatic portosystemic shunt (TIPS) is a procedure used to treat portal hypertension complications. Our aim was to evaluate liver and spleen stiffness measurement (LSM and SSM, respectively) changes using acoustic radiation force impulse imaging (ARFI) in comparison to Child–Pugh scores for predicting hepatic venous pressure gradient (HVPG) decreases after TIPS implantation. Methods: This prospective study included 31 consecutive clinically significant portal hypertension patients with TIPS indication. All patients received LSM and SSM before TIPS, at baseline, 2 days (follow-up 1) and 6 weeks (follow-up 2) post-implantation. HVPG was performed during the TIPS procedure. Results: The mean decrease in HVPG after TIPS was 63%. LSM and SSM decreased significantly between baseline and follow-up 2 (p < 0.001 and p < 0.001, respectively). At baseline, follow-up 1 and follow-up 2, significant correlations were detected between mean SSM and mean HVPG (p = 0.026; p = 0.018; p = 0.002, respectively). HVPG decreased to ≤ 10 mmHg in 61% of patients for which LSM, SSM, and Child–Pugh score were predictors (p = 0.033, p = 0.002 and p = 0.030, respectively). The area under the curve (AUC) for LSM, SSM, and Child–Pugh was 0.88, 0.90, and 0.84, respectively, with close sensitivity and specificity. SSM had the highest diagnostic accuracy for predicting an HVPG decrease to ≤ 10 mmHg in comparison to LSM and Child–Pugh score. Conclusion: Spleen stiffness is superior to liver stiffness and Child–Pugh score as a non-invasive surveillance tool for evaluating patients with clinically significant portal hypertension (HVPG ≥ 10 mmHg) prior to TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Association of advanced hepatic fibrosis and sonographic visualization score: a dual-center study using ACR US LI-RADS

Purpose: To evaluate the association between imaging and clinical features and visualization scores, as specified by American College of Radiology (ACR) Ultrasound Liver Imaging Reporting and Data System (LI-RADS), on hepatocellular carcinoma (HCC) screening ultrasound examinations. Methods: In this dual-center retrospective study, HCC screening ultrasound reports containing ultrasound elastography measurements (January to September, 2017) were reviewed. Ultrasound point shear wave elastography and 2-dimensional shear wave elastography were used to assess liver stiffness; median shear wave velocity was translated to METAVIR fibrosis scoring, per previously published data. Reports were analyzed for subject age, sex, reason for HCC screening, spleen size, fibrosis scores, and assigned ultrasound visualization scores. Jonckheere–Terpstra trend and Kendall’s tau-b coefficient analyses were performed. Results: 714 subjects (mean age 55; 51% male, 49% female) were included. 308 (43%) subjects had clinically declared cirrhosis; 406 (57%) did not. Majority (535, 75%) of exams were adequate (Visualization Score A), 156 (22%) moderately limited (Visualization Score B), and 23 (3%) severely limited (Visualization Score C). Increasing spleen size and patient age were associated with worsening visualization scores (p < 0.001). Suboptimal visualization was also associated with clinically significant fibrosis (≥ F2) by elastography (Kendall’s tau-b = 0.181, p < 0.001) and clinically declared cirrhosis (Kendall’s tau-b = 0.433, p < 0.001). There was no association with patient sex. Conclusion: Using ACR Ultrasound LI-RADS visualization score assessment, majority (75%) of HCC screening exams were diagnostically adequate, and only 3% were severely limited. Sonoelastographic diagnosis of clinically significant fibrosis, as well as clinical cirrhosis, increased patient age, and spleen size, were associated with greater diagnostic limitations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Chemoembolization of Unresectable Hepatocellular Carcinoma with Drug Eluting Beads: Results of an Open-Label Study of 62 Patients

The purpose of this study was to assess the safety and efficacy of doxorubicin-loaded beads (DC Beads) delivered by transarterial embolization for the treatment of unresectable hepatocellular carcinoma (HCC). This open-label, single-center, single-arm study included 62 cirrhotic patients with documented single unresectable HCC. Mean tumor diameter was 5.6 cm (range, 3-9 cm) classified as Okuda stages 1 (n = 53) and 2 (n = 9). Patients received repeat embolizations with doxorubicin-loaded beads every 3 months (maximum of three). The maximum doxorubicin dose was 150 mg per embolization, loaded in DC Beads of 100-300 or 300-500 {mu}m. Regarding efficacy, overall, an objective response according to the European Association for the Study of the Liver criteria was observed in 59.6%, 81.8%, and 70.8% across three treatments. A complete response was observed in 4.8% after the first procedure and 3.6% and 8.3% after the second and third procedures, respectively. At 9 months a complete response was seen in 12.2%, an objective response in 80.7%, progressive disease in 6.8%, and 12.2% showed stable disease. Mean tumor necrosis ranged from 77.4% to 83.9% (range, 28.6%-100%) across three treatments. {alpha}-Fetoprotein levels showed a mean decrease of 1123 ng/ml (95% CI = 846-1399; p = 3 x 10{sup -11}) after the first session and remained stable after the second and third embolizations (42 and 70 ng/ml decrease, respectively). Regarding safety, bilirubin, {gamma}-glutamyl transferase, aspartate aminotransferase, alanine aminotransferase, and alkaline phosphatase showed only transient increases during the study period. Severe procedure-related complications were seen in 3.2% (cholecystitis, n 1; liver abscess, n = 1). Postembolization syndrome was observed in all patients. We conclude that hemoembolization using doxorubicin-loaded DC Beads is a safe and effective treatment of HCC as demonstrated by the low complication rate, increased tumor response, and sustained reduction of {alpha}-fetoprotein levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Thermal Ablation Using Ferrofluids: Influence of Administration Mode on Biological Effect in Different Porcine Tissues

The purpose of this study was to compare the effects of magnetic thermal ablation in different porcine tissues using either a singular injection or a continuous infusion of superparamagnetic iron oxide nanoparticles. In the first setting samples of three ferrofluids containing different amounts of iron (1:171, 2:192, and 3:214 mg/ml) were singularly interstitially injected into specimens of porcine liver, kidney, and muscle (n = 5). Then the specimens were exposed to an alternating magnetic field (2.86 kA/m, 190 kHz) generated by a circular coil for 5 min. In the second experimental setup ferrofluid samples were continuously interstitially infused into the tissue specimens during the exposure to the magnetic field. To measure the temperature increase two fiber-optic temperature probes with a fixed distance of 0.5 cm were inserted into the specimens along the puncture tract of the injection needle and the temperature was measured every 15 s. Finally, the specimens were dissected, the diameters of the created thermal lesions were measured, and the volumes were calculated and compared. Compared to continuous infusion, a single injection of ferrofluids resulted in smaller coagulation volumes in all tissues. Significant differences regarding coagulation volume were found in kidney and muscle specimens. The continuous infusion technique led to more elliptically shaped coagulation volumes due to larger diameters along the puncture tract. Our data show the feasibility of magnetic thermal ablation using either a single interstitial injection or continuous infusion for therapy of lesions in muscle, kidney, and liver. Continuous infusion of ferrofluids results in larger zones of necrosis compared to a single injection technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Follow-Up After Successful Transjugular Intrahepatic Portosystemic Shunt Placement in a Pediatric Patient with Budd-Chiari Syndrome

Orthotopic liver transplantation is the standard of care in patients with Budd-Chiari syndrome (BCS), and transjugular intrahepatic portosystemic shunt (TIPS) has become an important adjunct procedure while the patient is waiting for a liver. No long-term follow up of TIPS in BCS patients has been published in children. We report successful 10-year follow-up of a child with BCS and iatrogenic TIPS dysfunction caused by oral contraceptive use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unusual Severe Complication Following Transarterial Chemoembolization for Metastatic Malignant Melanoma: Giant Intrahepatic Cyst and Fatal Hepatic Failure

We describe a 45-year-old male patient with malignant melanoma who underwent hepatic arterial chemoembolization due to liver metastases. Four months after the procedure, the patient developed a giant cystic cavity in the liver. Cytologic examination of the cystic fluid retention revealed necrotic tumor material. The fluid was drained by percutaneous catheter, but the patient developed hepatic failure. This case represents another rare complication of transarterial chemoembolization and shows that transarterial chemoembolization may have rare fatal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Circumflex Iliac Artery-Related Hemoperitoneum Formation After Surgical Drain Placement: Successful Transcatheter Embolization

A 53-year-old woman with liver cirrhosis and hepatocellular carcinoma underwent living donor liver transplantation. After transplantation, her hemoglobin and hematocrit levels decreased to 6.3 g/dl and 18.5%, respectively, during the course of 3 days. A contrast-enhanced abdominal computed axial tomography (CAT) scan showed a hemoperitoneum in the right perihepatic space with no evidence of abdominal wall hematoma or pseudoaneurysm formation. An angiogram of the deep circumflex iliac artery (DCIA) showed extravasation of contrast media along the surgical drain, which had been inserted during the transplantation procedure. Transcatheter embolization of the branches of the DCIA was successfully performed using N-butyl cyanoacrylate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transcholecystic Placement of an ePTFE/FEP-Covered Stent in the Common Bile Duct

We report the case of a 78-year-old male patient with obstructive jaundice due to a pancreatic head neoplasm. The patient's general condition did not permit an endoscopic approach and the presence of diffuse liver metastases prohibited hepatic puncture for percutaneous biliary drainage, therefore the transcolecystic transperitoneal approach was decided to be the safest decompression route. Through a gallbladder access, a Viabil-covered stent with a mesh extension was placed in the distal common bile duct, without complications. The patient died 8 months later without signs of stent dysfunction or necessity of reintervention. Transcholecystic transperitoneal access is a safe option when diffuse liver metastases prohibit the transhepatic approach, even in cases where placement of a covered stent is considered necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologic-Pathologic Correlation of Hepatocellular Carcinoma Treated with Chemoembolization

To correlate posttreatment radiologic and pathologic findings in patients who underwent transarterial chemoembolization before transplantation or resection. Thirty-five patients with postchemoembolization follow-up imaging underwent liver transplantation/resection. Pre- and posttreatment contrast-enhanced magnetic resonance imaging were used to evaluate radiologic findings. Imaging characteristics using World Health Organization (WHO) and European Association for the Study of the Liver (EASL) criteria after treatment were evaluated. Treated lesions were examined by pathology (gold standard) for the assessment of necrosis. Radiologic findings on magnetic resonance imaging were correlated to pathologic findings to assess the predictability by imaging of actual necrosis. Kappa ({kappa}) statistics were used to determine intermethod agreement between WHO and EASL criteria. Fourteen (40%) of 35 lesions had biopsy-proven hepatocellular carcinoma. Thirteen (37%) of 35 target lesions showed complete pathologic necrosis. Complete pathologic necrosis was seen in 35% of lesions with pretreatment size <3 cm. Complete pathologic necrosis was seen in 1 (100%) of 1, 6 (67%) of 9, 6 (33%) of 18, and 0 (0%) of 7 of the lesions that exhibited complete response (CR), partial response (PR), stable disease (SD), or progressive disease (PD) by WHO criteria, respectively. Complete pathologic necrosis was seen in 9 (82%) of 11, 4 (36%) of 11, 0 (0%) of 8, and 0 (0%) of 5 of the lesions that showed CR, PR, SD, or PD by EASL criteria, respectively. EASL CR and WHO response were shown to have {>=}85% specificity for predicting complete pathologic necrosis. The {kappa} coefficient for agreement between WHO and EASL was 0.29. EASL and WHO criteria had minimal intermethod agreement. EASL CR and WHO response were able to predict pathologic necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of Direct Current-Enhanced Radiofrequency Ablation: An Ex Vivo Study

The purpose of this study was to investigate the optimal setting for radiofrequency (RF) ablation combined with direct electrical current (DC) ablation in ex vivo bovine liver. An electrical circuit combining a commercially available RF ablation system with DC was developed. The negative electrode of a rectifier that provides DC was connected to a 3-cm multitined expandable RF probe. A 100-mH inductor was used to prevent electrical leakage from the RF generator. DC was applied for 15 min and followed by RF ablation in freshly excised bovine livers. Electric current was measured by an ammeter. Coagulation volume, ablation duration, and mean amperage were assessed for various DC voltages (no DC, 2.2, 4.5, and 9.0 V) and different RF ablation protocols (stepwise increase from 40 to 80 W, 40 W fixed, and 80 W fixed). Results were compared using Kruskal-Wallis and Mann-Whitney U test. Applying DC with 4.5 or 9.0 V, in combination with 40 W fixed or a stepwise increase of RF energy, resulted in significantly increased zone of ablation size compared with 2.2 V or no DC (P = 0.009). At 4.5 V DC, the stepwise increase of RF energy resulted in the same necrosis size as a 40 W fixed protocol (26.6 {+-} 3.9 vs. 26.5 {+-} 4.0 ml), but ablation duration was significantly decreased (296 {+-} 85 s vs. 423 {+-} 104 s; P = 0.028). Mean amperage was significantly lower at 4.5 V compared with 9.0 V (P = 0.028). Combining a stepwise increase of RF energy with a DC voltage of 4.5 V is most appropriate to increase coagulation volume and to minimize procedure time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cutaneous Bronchobiliary Fistula Treated with Tissucol Sealant

Bronchobiliary fistula is a rare and is an uncommon but severe complication of hydatid disease of the liver. Treatment has traditionally been surgical resection, but embolization and stent placement have been described. The invasive method seems to be a key component of patient treatment. We describe a case of a 58-year-old woman who, 25 years before, had undergone surgery for a hydatid cyst. A total cystectomy without previous puncture or parasite extraction was carried out. The lower aspect of the cyst was found to be completely perforated over the biliary duct. During the postoperative course, the patient had subphrenic right-sided pleural effusion and biliary fistula that subsided with medical treatment. Afterward, the patient came to the outpatient area of our hospital complaining of leakage of purulent exudate through the cutaneous opening, pain located on the right hypochondrium radiating to the right hemithorax, malaise, fever, chronic cough, and occasional vomiting of bile. Fistulography revealed an anfractuous cavity communicating with a residual cystic cavity on the right hepatic lobe. We observed communication with the intrahepatic canaliculi. Computed tomographic scan revealed a fistulous tract on the anterior liver border through the abdominal wall. There were no posttreatment complications. The patient is asymptomatic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Bleeding Stomal Varices by Direct Percutaneous Approach

Stomal varices can occur in patients with stoma in the presence of portal hypertension. Suture ligation, sclerotherapy, angiographic embolization, stoma revision, beta blockade, portosystemic shunt, and liver transplantation have been described as therapeutic options for bleeding stomal varices. We report the case of a 21-year-old patient with primary sclerosing cholangitis and colectomy with ileostomy for ulcerative colitis, where stomal variceal bleeding was successfully treated by direct percutaneous embolization. We consider percutaneous embolization to be an effective way of treating acute stomal bleeding in decompensated patients while awaiting decisions regarding shunt procedures or liver transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗